Records from 2000 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 81
16 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8350506
25 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8316396
9 April 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8108596
3 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8014053
13 June 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7934389
4 April 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7869475
7 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861634
19 January 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602480
20 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434433
2 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7389767
25 October 2021
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7339326
20 April 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179208
21 February 2020
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6913302
14 January 2020
Administrative Inspection · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6889478
9 January 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6886059
23 November 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861937
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
15 August 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6783935
17 October 2018
Deficiency Check · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6563525
29 June 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459128
28 June 2018
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459112
30 May 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429072
16 January 2018
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6338195
7 July 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6200706
9 March 2017
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102037
21 November 2016
In-Service Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6044994
16 February 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5815502
20 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5800156
5 March 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4810219
21 February 2012
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4248310
25 January 2012
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4231236
10 February 2011
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3947427
25 February 2010
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3684839
27 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3670744
21 January 2010
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3666899
25 February 2009
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3423790
13 February 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3417288
9 January 2009
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3391197
17 June 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3246311
6 June 2008
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3229016
6 June 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3254546
24 January 2008
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135900
22 January 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3134751
14 January 2008
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3130313
3 July 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2981788
7 June 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975819
14 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2888107
5 March 2007
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2882531
12 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2870833
6 February 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867932
26 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2808675
16 June 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2681869
27 April 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2635265
21 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2607011
14 March 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2602504
7 March 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2598181
18 January 2006
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2568609
4 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2560948
11 October 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2511834
11 August 2005
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2459474
5 August 2005
Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2452436
20 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2433318
7 July 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2418372
4 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2326445
7 March 2005
Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2305392
5 March 2004
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2016969
28 January 2004
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1995071
31 May 2003
Deficiency Check · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1806343
31 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1808578
19 February 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1746333
26 June 2002
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637214
18 June 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1636787
25 February 2002
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1489233
2 January 2002
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476211
1 May 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063292
20 February 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436514
18 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 35343
7 June 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050885
2 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 116987
28 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406689
7 February 2000
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination · Plan Review "T" Boat · Deadweight Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1399339
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2024
Resolved
"Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors." All four engine block heaters must be removed from vessel due to electrical shock hazard, poor workmanship and installation. MI was presented with a shock hazard while inspecting engine shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: The block heaters were removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 April 2024
Resolved
MI's observed a cracked weld in the starboard #2 void above the waterline. Vessel needs repair and perform NDT in the presence of an MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: NDT LDP on the weld was completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 April 2024
Resolved
"Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations." MI's observed water leaking around hull connection of the inboard starboard jet drive. epair and conduct functional test in presence of MI's
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: The Jet steering cylinder that was leaking in water was replaced, ran an operational test with no leaks
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2024
Resolved
"A duct must be of rigid permanent construction, which does not allow any appreciable vapor flow except through normal openings, and made of the same material as the hull or of noncombustible material. The duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported." MI's observed gasket material around opening leading to port engine compartment in poor condition and partially removed from closure to compartment. Restore to like new condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: Port ER hatch gasket was removed and replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2024
Resolved
"Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The marking is not required on a life jacket carried to meet a temporary need for additional life jackets, if the life jacket has the name of another vessel or company marked on it. For an immersion suit, the name of the person to whom the immersion suit is assigned is an acceptable alternative to the name of the vessel." MI's observed starboard forward and port aft life rings missing letters for name of vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2024
Resolution: All life ring lettering was redone.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2024
Resolved
"A duct must be of rigid permanent construction, which does not allow any appreciable vapor flow except through normal openings, and made of the same material as the hull or of noncombustible material. The duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported." MI's observed forward starboard ventilation damper not fully closing after conducting test of CO2 shutdown. Vessel's crew rectified deficiency while inspection was being conducted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
Resolution: Def was rectified on during the inspection and tested sat.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 4 April 2024
Resolved
"At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. (b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes." MI's observed mold in overhead and ceiling tiles, oil in both engine compartment bilges and soaked into insulation. Must clean passenger spaces ,both engine rooms, lazarette and remove all debris, insulation, oil, hydraulic fluid from all surfaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: Insulation at bilge level was removed to not soak up any fluids
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2020
Resolved
Install placarding on E/R hatches to keep closed during operation.
Action required: 705 - Other - as specified
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 February 2020
Resolved
Remove all plastic piping from bilge system.
Action required: 705 - Other - as specified
Resolved 2 March 2020
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 21 February 2020
Resolved
Forward door in cabin area does not open. Fix.
Action required: 705 - Other - as specified
Resolved 2 March 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 February 2020
Resolved
Port Laz
-Finish stitch welds.
-Straighten bent longitudinal and weld.
-Weld pipe bracket into place.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Observed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020
Resolved
Port aft top deck
-Multiple cracked stanchions. Repair.
-Broken deck. Crop and renew. Fitup authorized.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Observed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020
Resolved
Vessel did not have fire resistant sight glasses.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2020
Resolved 16 January 2020
Resolution: Operator installed proper sight glass for fuel tank.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 November 2019
Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant and meet the system requirements of 46CFR181.410. Attending Marine Inspector (MI) found the port side engine room pressure switch inoperable and the starboard side engine room system required maintenance to operate. Vessel is not operating in compliance with the COI.
46 CFR 181.410(a)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 26 November 2019
Resolution: The system had maintenance performed by SEA SAFETY and performed as required during an operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 November 2019
Resolved
Each ring life buoy on a vessel must be in compliance with 46CFR160.050. Attending MI determined the grab lines on the after life ring buoy to be deteriorated.
46CFR180.70(b)(1)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Life ring was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 November 2019
Resolved
Each hatch exposed to the weather must be watertight. Attending MI found the both lazarette hatch covers not watertight (bad gasket and seized dogging mechanism).
46CFR179.360(a)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Port o-ring was replaced and the starboard hatch cover was replaced with an operational unit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
A vessel is inspected for compliance with the standards required by this subchapter; arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Attending MI found there was insulation missing in the port engine room, aft and inboard which was part of the original installation and arrangement of the space.
46CFR176.800(a)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Insulation had been replaced.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 November 2019
Resolved
Fixed gas fire extinguishing systems shall be inspected and tested in accordance with 46CFR147.60, 147.65 and 176.810(b). Attending MI found the fixed gas fire fighting system alarm horns excessively deteriorated and evidenced a of lack of maintenance.
46CFR176.810(b)(2)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Both alarm horn covers were replaced with new covers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.830
Action required: 30 - Ship detained
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 August 2019
Resolved
Provide technician report for fixed fire extinguishing servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Fixed fire extinguishing system serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 15 August 2019
Resolved
Observed corroded pad eyes on main deck compromising watertight integrity of voids underneath the main deck. Replace corroded pad eyes to maintain watertight integrity of main deck and spaces below.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Pad eyes replaced to maintain watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2019
Resolved
Observed multiple areas on port and starboard sides where rub rails are missing. Replace all missing rub rails around the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2019
Resolution: Missing rub rails are replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2019
Resolved
Replace missing starboard aft cleat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2019
Resolution: Installed new aft cleat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 August 2019
Resolved
Repair leak in starboard shaft packing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Leak from starboard shaft packing fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2019
Resolved
Replace gaskets on bridge doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Gasket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2019
Resolved
Remove dead end wires located inside the bridge cabinet, starboard aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2019
Resolved
Reposition and secure loose hanging electrical wire in the bilge located in starboard lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Loose electrical wire secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2019
Resolved
Label life jacket stowage location with type and number of life jackets (port side main cabin, leading into engine room).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Life jacket stowage properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2019
Resolved
Provide proof LED navigational lights meet UL 1104.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Provide proof of nav lights meeting UL1104
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2019
Resolved
Replace 2 corroded fire extinguisher brackets located at the port and starboard aft deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Fire extinguisher brackets replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2018
Resolved
Each vessel that relies on electricity to power vital systems, interior lighting, communication systems, and vanigations systems must be arranged so that the loads can be energized from two sources of electricity. Vessel's #1 generator completely shut down and the vessels #2 generator was reading power loss errors with no working guages.
Vessel must prove two sources of power for the systems listed above to an attending MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Resolution: Vessel proved proper operation of both generators to attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 June 2018
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passenger and crew. Equivalent protection may include, lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Bulwarks on the port quarter, passenger upper deck, are heavily damaged. Replace or make proper repairs to identified bulwarks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 14 August 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 June 2018
Resolved
Following a grounding, vessel must be assessed for a return to commercial service. The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel must be attended by CG Marine Inspector and deemed fit for service intended.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2018
Resolution: Attended vessel, inspected satisfactory
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
Stern light wiring is exposed to weather
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
wiring located above port ansd starboard engines are supported using zipties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
Wiring located above generator in engine room is covered with rubber and clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 May 2018
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside scope of annual inspection window and shall complete required annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2018
Resolution: 3rd annual inspection was conducted
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 May 2018
Resolved
Upon testing the fixed CO2 system, the automatic shutdowns of ventiliation and engines were inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2018
Construction/Loadline › Hull › Weld
Issued 21 February 2012
Resolved
V/W Crack IWO fwd superstructure and fwd main deck P/S.
Due 1 March 2012
Resolved 1 March 2012
Resolution: Attended vessel, repair was made satisfactory.
Construction/Loadline › Structures › Superstructure
Issued 21 February 2012
Resolved
C/R damaged section of port side rub rail amidship.
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 1 March 2012
Resolution: Visually inspected, repair was made satisfactory.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 February 2012
Resolved
Remount electronic control unit for the inboard port side jet drive steering control
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 1 March 2012
Resolution: Visually inspected, repair made satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 21 February 2012
Resolved
Replace damaged rub rail on the stbd side.
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 1 March 2012
Resolution: Visually inspected, repairs made satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 21 February 2012
Resolved
V/W rub rail portside aft.
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 1 March 2012
Resolution: Visually inspected, repair made satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 February 2012
Resolved
Replace hand hold leading into the portside steering gear space.
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 1 March 2012
Resolution: Visually inspected, repair made satisfactory.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 February 2011
Resolved
Vessel must provide proof of current FCC Vessel Bridge-to-Bridge Radiotelephony Certificate
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2011
Resolved 17 February 2011
Resolution: Rcvd copy of up-to date certificate.
Engineering › Fuel Oil Service System › Piping
Issued 17 February 2011
Resolved
Vessel must remove all absorbent pads from engine room and do not put them back as discussed with vessel rep. Make an repairs needed to avoid utilizing pads in the future
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 17 February 2011
Resolved
Make permanent repairs to mounting brackets for electrical control units in jet space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 February 2011
Resolved
All battery banks must be mounted to protect against shifting in the engine room and jet spaces
Condition: Improper/Lack of Maintenance
Due 17 February 2011
Resolved 17 February 2011
Engineering › Bilge Water Management System › Piping
Issued 21 January 2010
Resolved
Replace non-metallic through-hull fitting for electronic submersible bilge pump with metallic through-hull fittings in kind. 46 CFR 182.720
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 31 January 2012
Resolution: Visually inspected metallic through hull fitting for submersible bilge pump in the steering gear space, all other voids still have non-metallic through hull fittings on the secondary (non fixed piping bilge system / submersible pumps). See Narrative.
Engineering › Steering Gear System › Feedback Unit
Issued 9 January 2009
Resolved
Prove proper operation of both port and starboard Jet Control Systems to the satisfaction of attending MI. **PTCP**
Action required: 705 - Other - as specified
Resolved 14 January 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 June 2008
Resolved
Service all fire extinguishers prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Service reports received.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 June 2008
Resolved
Properly secure bilge alarm.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Installed new screws.
Construction/Loadline › Hull › Side Shell
Issued 6 June 2008
Resolved
Prior to commercial operations, make proper repairs to side shell port side #2 void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 12 June 2008
Engineering › Gasoline Engine (propulsion) › Valve Cover (4 cycle)
Issued 14 January 2008
Resolved
Replace missing covers for generator intakes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 16 January 2008
Construction/Loadline › Hull › Weld
Issued 14 January 2008
Resolved
Repair cracked weld on port side forepeak. (#1 Void Space) A/M.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 16 January 2008
Engineering › Fuel Oil Service System › Hose
Issued 14 January 2008
Resolved
Hoses in fuel void space port and starboard need to be replaced as marked. (AC and Generators)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Engineering › Fuel Oil Service System › Hose
Issued 14 January 2008
Resolved
Fire Sleeves need to be refasten with metal or appoved materials as marked. (P/S fuel void /engine room)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Engineering › Compressed Air System (control) › Piping
Issued 14 January 2008
Resolved
AC discharge hose must be replaced as marked (P fuel void space)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Engineering › Bilge Water Management System › Pump
Issued 14 January 2008
Resolved
Bilge pump discharge hose (stbd fuel void space) needs 2 clamps.
Condition: Unknown
Due 30 January 2008
Resolved 16 January 2008
Engineering › Generator (propulsion/auxiliary-electric) › Cable
Issued 14 January 2008
Resolved
Generator oil drain hose needs replacement (stbd)
Condition: Unknown
Due 30 January 2008
Resolved 16 January 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 January 2008
Resolved
Sea suction hose IWO stbd A/C unit needs replacement.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2007
Resolved
Wiring for fuel pump in port side generator space has exposed splices at pump and IVO transverse frame overhead. Place wire splices in an enclosure.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 5 March 2007
Resolved
Replace missing wiring enclosure cover on port generator.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 March 2007
Resolved
Secure bateries from movement in starboard jet space.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 5 March 2007
Resolved
Replace cut/worn raw water supply hose on port side aft MDE.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Engineering › Fuel Oil Service System › Hose
Issued 5 March 2007
Resolved
Properly secure fire sleeve on fuel hoses throughout port engine room.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 5 March 2007
Resolved
Secure emergency exit ladder to bulkhead in port engine room.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 March 2007
Resolved
Properly secure batteries in way of starboard engine compartment.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Construction/Loadline › Hull › Weld
Issued 5 March 2007
Resolved
Make repairs to incomplete weld in way of 2nd web frame from forward bulkhead at side shell.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 March 2007
Resolved
Install lifejacket donning placards on main deck.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 March 2007
Resolved
Provide portable lighting (flashlights) at entrances to port and starboard engine rooms.
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 7 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 March 2005
Resolved
Provide servicing reports for fixed fire extinguishers and portable fire extinguishers. Expired in Feb. 2005.
Due 11 March 2005
Resolved 10 March 2005
Resolution: Received servicing certificates from SEA SAFETY INTERNATIONAL dated 3/9/05.
Communications › Radio Communications › EPIRB
Issued 7 March 2005
Resolved
Provide new battery for EPIRB. Route shall be reduced to within 3 NM of land, until requirement satisfied.
Due 11 March 2005
Resolved 10 March 2005
Resolution: Viewed EPIRB with new battery.
Construction/Loadline › Structures
Issued 31 May 2003
Resolved
Make permanent repairs to furnace stove pipe housing and latch mechanism. Do not operate unit until permanent repairs have been completed to the satisfaction of USCG marine inspector. LEGACY COMPONENT DESC: Heating furnace stove pipe housing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 June 2003
Resolved 10 June 2003
Resolution: Damaged area repaired to perform as intended as witnessed by attending MI.
Documentation › Certificates/Documents
Issued 19 February 2003
Resolved
Properly post COI and Stability ltr so all pages are visible.
Due 3 March 2003
Resolved 4 March 2003
Operations/Management › Drills/Instruction
Issued 19 February 2003
Resolved
Post emergency instructions IAW 46CFR185.510
Due 3 March 2003
Resolved 4 March 2003
Navigation › Piloting/Steering
Issued 19 February 2003
Resolved
Provide current copy of CG Light List and all appropriate charts for operating area. LEGACY COMPONENT DESC: Coast Guard Light List
Due 3 March 2003
Resolved 4 March 2003
Navigation › Piloting/Steering
Issued 19 February 2003
Resolved
Prove proper operation of mag compass and provide deviation table. LEGACY COMPONENT DESC: Magnetic Compass
Due 3 March 2003
Resolved 4 March 2003
Communications › Internal Communications System
Issued 19 February 2003
Resolved
Post legend of phone numbers for internal phone. LEGACY COMPONENT DESC: Internal Telephone
Due 3 March 2003
Resolved 4 March 2003
Construction/Loadline › Hull
Issued 25 February 2002
Resolved
Crop and renew stbd decking in way of second cleat from aft. Repair cleat. LEGACY COMPONENT DESC: Hull Plating
Due 14 March 2002
Resolved 18 June 2002
Resolution: Rubrail V/W and sacrificial deck straightened and V/W.
Fire Fighting
Issued 1 May 2001
Resolved
Renew the inoperable momentary contact switch #3 for the fire alarm/test panel.
Condition: Unknown
Due 11 May 2001
Resolved 11 May 2001
Fire Fighting
Issued 20 February 2001
Resolved
Prove proper operation of heat sensor for port generator set
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Electrical
Issued 20 February 2001
Resolved
Provide portable lighting at engine room P/S and pilot house IAW 46CFR 183.430
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Accommodation/Occupational Safety
Issued 20 February 2001
Resolved
Mark emergency exit for engine room IAW 46CFR185.606
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Engineering
Issued 20 February 2001
Resolved
Install 30X30 mesh flame screens on fuel tank vents.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Deck/Cargo
Issued 20 February 2001
Resolved
Prove proper/adequate length of anchor line for all routes
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Lifesaving
Issued 20 February 2001
Resolved
Provide 6 hand held, and 6 orange smoke flares
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Navigation
Issued 28 March 2000
Resolved
Either raise masthead light or lower radar, so that Anchor light is visiblefrom 360 degrees in accordance with NAV Rules.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Fire Fighting
Issued 28 March 2000
Resolved
Provide a fixed gas fire extinguishing system for the oil fired heater space. This space which was previously determined to be so open to the atmosphere that extinguishing would be ineffective has been enclosed.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Navigation
Issued 28 March 2000
Resolved
Provide a 12 inch bell in accordance with NAV Rules.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Lifesaving
Issued 7 February 2000
Resolved
Vessel shall not be placed into passenger carrying service until Fire, Person Overboard, and Abandon Ship drills are conducted to the satisfactionof an attending Coast Guard Marine Inspector.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Navigation
Issued 7 February 2000
Resolved
Post current compass deviation table.
Condition: Unknown
Due 7 March 2000
Resolved 27 March 2000
Documentation
Issued 7 February 2000
Resolved
Vessel shall not be placed into passenger carrying service until an approved stability letter is issued by the U.S. Coast Guard Marine Safety Center and posted on board the vessel.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Unknown
Issued 7 February 2000
Resolved
Vessel shall not be placed into passenger carrying service until a new to zone inspection is completed by a U.S. Coast Guard Activities New York Marine Inspector.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Documentation
Issued 7 February 2000
Resolved
Provide copies and/or post emergency instructions, training logs, lifesaving equipment maintenance logs, bridge logs, and crew licenses in accordance with 46 CFR part 185.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Documentation
Issued 7 February 2000
Resolved
Optain and post an FCC station license.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000