Records from 2008 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 28
16 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8350506
25 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8316396
9 April 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8108596
3 October 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8014053
13 June 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7934389
4 April 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7869475
7 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861634
19 January 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602480
20 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434433
2 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7389767
25 October 2021
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7339326
20 April 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179208
21 February 2020
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6913302
14 January 2020
Administrative Inspection · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6889478
9 January 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6886059
23 November 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861937
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
15 August 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6783935
17 October 2018
Deficiency Check · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6563525
29 June 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459128
28 June 2018
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459112
30 May 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429072
16 January 2018
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6338195
7 July 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6200706
9 March 2017
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102037
21 November 2016
In-Service Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6044994
16 February 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5815502
20 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5800156
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2024
Resolved
"Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors." All four engine block heaters must be removed from vessel due to electrical shock hazard, poor workmanship and installation. MI was presented with a shock hazard while inspecting engine shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: The block heaters were removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 April 2024
Resolved
MI's observed a cracked weld in the starboard #2 void above the waterline. Vessel needs repair and perform NDT in the presence of an MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: NDT LDP on the weld was completed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 April 2024
Resolved
"Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations." MI's observed water leaking around hull connection of the inboard starboard jet drive. epair and conduct functional test in presence of MI's
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: The Jet steering cylinder that was leaking in water was replaced, ran an operational test with no leaks
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2024
Resolved
"A duct must be of rigid permanent construction, which does not allow any appreciable vapor flow except through normal openings, and made of the same material as the hull or of noncombustible material. The duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported." MI's observed gasket material around opening leading to port engine compartment in poor condition and partially removed from closure to compartment. Restore to like new condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: Port ER hatch gasket was removed and replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2024
Resolved
"Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The marking is not required on a life jacket carried to meet a temporary need for additional life jackets, if the life jacket has the name of another vessel or company marked on it. For an immersion suit, the name of the person to whom the immersion suit is assigned is an acceptable alternative to the name of the vessel." MI's observed starboard forward and port aft life rings missing letters for name of vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 April 2024
Resolution: All life ring lettering was redone.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2024
Resolved
"A duct must be of rigid permanent construction, which does not allow any appreciable vapor flow except through normal openings, and made of the same material as the hull or of noncombustible material. The duct must lead as directly as possible from its intake opening to its terminus and be securely fastened and supported." MI's observed forward starboard ventilation damper not fully closing after conducting test of CO2 shutdown. Vessel's crew rectified deficiency while inspection was being conducted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2024
Resolution: Def was rectified on during the inspection and tested sat.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 4 April 2024
Resolved
"At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. (b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes." MI's observed mold in overhead and ceiling tiles, oil in both engine compartment bilges and soaked into insulation. Must clean passenger spaces ,both engine rooms, lazarette and remove all debris, insulation, oil, hydraulic fluid from all surfaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2024
Resolution: Insulation at bilge level was removed to not soak up any fluids
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 February 2020
Resolved
Install placarding on E/R hatches to keep closed during operation.
Action required: 705 - Other - as specified
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 February 2020
Resolved
Remove all plastic piping from bilge system.
Action required: 705 - Other - as specified
Resolved 2 March 2020
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 21 February 2020
Resolved
Forward door in cabin area does not open. Fix.
Action required: 705 - Other - as specified
Resolved 2 March 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 February 2020
Resolved
Port Laz
-Finish stitch welds.
-Straighten bent longitudinal and weld.
-Weld pipe bracket into place.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Observed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020
Resolved
Port aft top deck
-Multiple cracked stanchions. Repair.
-Broken deck. Crop and renew. Fitup authorized.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Observed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020
Resolved
Vessel did not have fire resistant sight glasses.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2020
Resolved 16 January 2020
Resolution: Operator installed proper sight glass for fuel tank.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 November 2019
Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant and meet the system requirements of 46CFR181.410. Attending Marine Inspector (MI) found the port side engine room pressure switch inoperable and the starboard side engine room system required maintenance to operate. Vessel is not operating in compliance with the COI.
46 CFR 181.410(a)
46 CFR 176.100(b)
Action required: 30 - Ship detained
Resolved 26 November 2019
Resolution: The system had maintenance performed by SEA SAFETY and performed as required during an operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 November 2019
Resolved
Each ring life buoy on a vessel must be in compliance with 46CFR160.050. Attending MI determined the grab lines on the after life ring buoy to be deteriorated.
46CFR180.70(b)(1)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Life ring was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 November 2019
Resolved
Each hatch exposed to the weather must be watertight. Attending MI found the both lazarette hatch covers not watertight (bad gasket and seized dogging mechanism).
46CFR179.360(a)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Port o-ring was replaced and the starboard hatch cover was replaced with an operational unit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
A vessel is inspected for compliance with the standards required by this subchapter; arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Attending MI found there was insulation missing in the port engine room, aft and inboard which was part of the original installation and arrangement of the space.
46CFR176.800(a)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Insulation had been replaced.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 November 2019
Resolved
Fixed gas fire extinguishing systems shall be inspected and tested in accordance with 46CFR147.60, 147.65 and 176.810(b). Attending MI found the fixed gas fire fighting system alarm horns excessively deteriorated and evidenced a of lack of maintenance.
46CFR176.810(b)(2)
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 26 November 2019
Resolution: Both alarm horn covers were replaced with new covers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
This vessel is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.830
Action required: 30 - Ship detained
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 August 2019
Resolved
Provide technician report for fixed fire extinguishing servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Fixed fire extinguishing system serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 15 August 2019
Resolved
Observed corroded pad eyes on main deck compromising watertight integrity of voids underneath the main deck. Replace corroded pad eyes to maintain watertight integrity of main deck and spaces below.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Pad eyes replaced to maintain watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2019
Resolved
Observed multiple areas on port and starboard sides where rub rails are missing. Replace all missing rub rails around the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2019
Resolution: Missing rub rails are replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2019
Resolved
Replace missing starboard aft cleat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2019
Resolution: Installed new aft cleat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 August 2019
Resolved
Repair leak in starboard shaft packing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Leak from starboard shaft packing fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2019
Resolved
Replace gaskets on bridge doors.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Gasket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2019
Resolved
Remove dead end wires located inside the bridge cabinet, starboard aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Dead end wires removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2019
Resolved
Reposition and secure loose hanging electrical wire in the bilge located in starboard lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Loose electrical wire secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2019
Resolved
Label life jacket stowage location with type and number of life jackets (port side main cabin, leading into engine room).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Life jacket stowage properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2019
Resolved
Provide proof LED navigational lights meet UL 1104.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Provide proof of nav lights meeting UL1104
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2019
Resolved
Replace 2 corroded fire extinguisher brackets located at the port and starboard aft deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2019
Resolution: Fire extinguisher brackets replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 October 2018
Resolved
Each vessel that relies on electricity to power vital systems, interior lighting, communication systems, and vanigations systems must be arranged so that the loads can be energized from two sources of electricity. Vessel's #1 generator completely shut down and the vessels #2 generator was reading power loss errors with no working guages.
Vessel must prove two sources of power for the systems listed above to an attending MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2018
Resolution: Vessel proved proper operation of both generators to attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 June 2018
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passenger and crew. Equivalent protection may include, lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Bulwarks on the port quarter, passenger upper deck, are heavily damaged. Replace or make proper repairs to identified bulwarks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2018
Resolved 14 August 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 June 2018
Resolved
Following a grounding, vessel must be assessed for a return to commercial service. The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel must be attended by CG Marine Inspector and deemed fit for service intended.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2018
Resolution: Attended vessel, inspected satisfactory
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
Stern light wiring is exposed to weather
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
wiring located above port ansd starboard engines are supported using zipties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2018
Resolved
Wiring located above generator in engine room is covered with rubber and clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 4 June 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 May 2018
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside scope of annual inspection window and shall complete required annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2018
Resolution: 3rd annual inspection was conducted
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 May 2018
Resolved
Upon testing the fixed CO2 system, the automatic shutdowns of ventiliation and engines were inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2018