Records from 2013 to 2026. Most recent: inspection, 23 July 2026.
Inspection history · 26
23 July 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8443544
5 August 2025
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8202957
4 June 2025
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8152271
30 October 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8026870
2 July 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7946926
25 September 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7797965
13 September 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790264
11 May 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685956
17 August 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7536378
31 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464357
29 September 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7322431
7 May 2021
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7193226
16 November 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7096460
19 August 2020
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7023695
24 June 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6990288
20 June 2020
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7014189
27 January 2020
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896639
9 January 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6886096
22 November 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6860917
18 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896988
5 August 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6773206
20 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584316
20 August 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6518044
14 August 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6240042
2 August 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5960651
19 July 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6134738
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 August 2025
No resolution recorded
(e)(2)" Each vessel certified to operate on a limited coastwise route within three miles of land in warm water must either: meet either... The standards for subdivison and damage stabilty... And not be required to carry survival craft." Vessel's survival craft has not been serviced. Service survival craft prior to operating beyong 3 miles from land in warm water.
46CFR180.205(a)(2)
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 June 2025
Resolved
"The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull" Barge allided with vessel that resulted in damage to port aft quarter. Affect repairs in accorance with the approved repair proposal prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2025
Resolution: crop and renew complete
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2023
Resolved
A vessel certificated to operate on a rivers route within one mile of land is not required to carry survival craft.
Vessel has sent IBAs out for servicing. While IBAs are out for service vessel route is limited to rivers, less than 1 mile from shore.
46 CFR 180.208 (c)
Action required: 705 - Other - as specified
Resolved 25 September 2023
Resolution: Vessel submitted inspection report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 January 2020
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Diesel fuel tank sight glasses do not have required devices that will automatically close in the event of a rupture.
46 CFR 182.440(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Received photos attesting to repairs. Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2020
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Several bilge suction pickups were missing strainers. Vessel rep. stated they would replace all strainers with metal type.
46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Received photos attesting to repairs. Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2020
Resolved
Exhaust gas must not leak from the piping or any connections. Identify exhaust leak in STB lazarette space and replace gasket material at exhaust flange connections.
46 CFR 182.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Received photos attesting to repairs. Def cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2020
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Several bilge suction lines have non approved hose.
46 CFR 182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 16 February 2020
Resolution: Received photos and documentation clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety
under normal and emergency conditions. Replace 02 missing selector switches/knobs on the main AC panel.
46 CFR 183.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Received photos attesting to repairs. Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2020
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type. Ground detection button on main AC panel is inoperable.
46 CFR 183.324
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Received photos attesting to repairs. Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 November 2019
Resolved
Extension cord on bridge plugging in several items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
Resolution: Extension cord was removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 November 2019
Resolved
On a vessel of at least 26', bilge high level alarms shall be provided in a lazarette bilge that is subject to flooding. Attending Marine Inspectors discovered the bilge high level alarm in the lazarette was not mounted and would not provide the alarms if water intrusion occurred.
46CFR182.530(a)(1)
Action required: 30 - Ship detained
Resolved 25 November 2019
Resolution: Alarm operational.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 November 2019
Resolved
Inflatable liferafts must be serviced at an approved facility and in accordance with the manufacturer's instructions no later than the month and year listed on the servicing sticker. Attending Marine Inspectors found that the inflatable buoyant apparatus had not been serviced and had been due since April 2018.
46CFR185.730(a)(1)
Action required: 30 - Ship detained
Resolved 26 November 2019
Resolution: IBA's on board were within servicing window.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 November 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to provide service under normal operating conditions, protect crew from electrical hazards and minimize accidental personnel contact with energized parts. Attending Marine Inspector found the lighting in the engine room to be connected via a temporary repair using a zip tie.
46CFR183.200(a)and (b)
46CFR183.410(b)(2)
Action required: 705 - Other - as specified
Due 29 November 2019
Resolved 26 November 2019
Resolution: Light properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2019
Resolved
HVAC temperature control on bridge hanging from panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2019
Resolution: COntrol remounted into panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 November 2019
Resolved
Port laz. bilge alarm not operable audio/visual.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2019
Resolution: Port laz bilge alarm audio/visual oerationally tested and functionined.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2019
Resolved
The vessel YORK is a "T-boat", therefore not required a safety management system (SMS) per regulation. Sector NY has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel.
46CFR176.25-50
Action required: 30 - Ship detained
Resolved 26 November 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 August 2019
Resolved
Repairs to machinery, and equipment that affect the safety of the vessel must not be made without the approval of the OCMI. Vessel had fire main piping leak in port engine room compartment. Temporary repairs were made by adding jubilee patch and permanent repairs will be made when vessel is pulled out for dry dock on 16AUG.
46 CFR 176.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 4 September 2019
Resolution: Recieved picture of permenent repairs of firemain piping
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2019
Resolved
A vessel must carry one floating waterlight with a ring buoy. Vessels waterlight on stbd side buoy needs replaced.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Bouy Light replaced
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 August 2019
Resolved
At each inspection for certification all observed fire hazards must be corrected. Remove oil from bilge in fwd stbd engine room.
46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Oil removed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 August 2019
Resolved
Each EPIRB must be tested monthly using the integrated test circuit and output indicator to determine that it is operative. Vessel could not provide monthly tests of EPIRB.
46 CFR 185.728(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Log book was created
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2019
Resolved
The number and identification of the items stowed inside and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel was missing labeling total amount of life jackets on main deck.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Life jackets were labled
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2019
Resolved
The operator of each self propelled vessel 12 meters or more in length shall carry on board and maintain ready for reference a copy of the Inland Navigations Rules. Provide a current updated copy of Navigation Rules.
33 CFR 88.05
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: New Nav Rulles was purchased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2019
Resolved
A bilge suction must be fitted with a suitable strainer. Vessel was missing strainer for bilge suction line in port fuel tank void.
46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Strainer installed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 August 2019
Resolved
Provision must be made for closing supply ducts for a space protected by fixed gas extinguishing system. Vessels powered louvers on stbd and port engine room doors did not close all the way when testing fixed firefighting system.
46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2019
Resolved 19 August 2019
Resolution: Louvers closed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 November 2018
Resolved
An Inflatable buoyant apparatus must be serviced at an approved facility no later than the month and year on the servicing sticker. Both IBAs on the vessel were beyond their inspection date. 46 CFR 185.730(a)(1) Route restricted to LBS
with-in 1 mile from shore.
Action required: 705 - Other - as specified
Due 27 November 2018
Resolved 28 November 2018
Resolution: Resolved via emailed pictures
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 November 2018
Resolved
Each item of lifesaving with an expiration date must be replaced if the expiration date has passed. The hydrostatic releases on both IBAs and on the EPIRB were all past their expiration dates. 46 CFR 176.808(b)
Action required: 705 - Other - as specified
Due 27 November 2018
Resolved 28 November 2018
Resolution: Resolved via emailed pictures.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 August 2018
Resolved
Replace lower sections of transom for both port and stbd hulls
Action required: 705 - Other - as specified
Due 31 August 2019
Resolved 3 August 2020
Resolution: Repaired to the satisfaction of attending marine inspectors.
Personnel › Training › Passenger Safety
Issued 14 August 2017
Resolved
Vessel and crew must complete satifactory fire & MOB drills in the presants of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2017
Resolution: Vessel conducted satisfactory drills
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 August 2017
Resolved
Vessel has an exhaust leak in the Laz space, this is a personel hazzard. Must find&replace/repair to new condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2017
Resolution: Vessel replaced all gaskets in all joints/flex couplings in the laz space.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 August 2017
Resolved
Vessel has not logged MOB, FF drills. Must maintain log as discussed and required per the regulation.
Due 14 September 2017
Resolved 19 September 2017
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 August 2017
Resolved
Vessel has no EPIRB testing log, must log monthly as discussed and per the regulation.
Due 14 September 2017
Resolved 19 September 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 August 2017
Resolved
Vessel's STBD MDE RPM, Oil, Coolant monitor/alarm panel on the bridge is broke, must repair/replace to new condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2017
Resolution: Vessel replaced burned out circut board.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 August 2016
Resolved
Provide valid Certificate of Documentation with coastwise endorsement. 46CFR67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2016
Resolved 4 August 2016
Resolution: Provided proof of COD.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 2 August 2016
Resolved
Vessel restricted to Rivers Route until IBA's and EPIRB properly installed. 46CFR180.200/46CFR180.640
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 21 November 2016
Electrical › Electric Generation Source (service) › Ground Detection
Issued 2 August 2016
Resolved
Prove proper operation of ground detection. 46CFR183.370
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 September 2016
Resolved 21 November 2016