Inspection history · 18
20 March 2025
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8096229
19 February 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8081256
4 March 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874053
4 January 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845365
24 April 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7674355
3 January 2023
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609093
11 February 2022
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7394699
20 January 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126786
19 February 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6911734
3 February 2020
In-Service Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6901445
12 February 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6635060
18 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6339686
17 January 2018
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6338937
3 January 2018
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6331632
12 September 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6271166
24 January 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6075878
26 January 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5819579
5 January 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5790966
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 20 March 2025
No resolution recorded
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 122.510, when applicable, the duties listed in the station bill required by § 122.514. Did not conduct drills during annual exam. Perform crew drills in the presence of attending MI prior to the carriage of passengers.
46 CFR 122.420(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 March 2025
Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements:
(1) A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead"
MI observed fire door between machinery and engine room not meeting fire control boundary with 1/2 inch gap under fire door. Submit repair plan.
46 CFR 116.435(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2025
No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Nothing in this subpart limits the marine inspector from conducting such tests or inspections necessary to be assured of the vessel's seaworthiness. Vessel does not normally operate and was not prepared to carry passengers. Prior to carrying passengers notify the OCMI for an in service inspection.
46 CFR 115.500(b)(1)(iv)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 March 2025
Resolved
All inlets and discharges led through the vessel's side shell shall be fitted with efficient and accessible means...for preventing the accidental admission of water into the vessel either through such pipes or in the event of fracture of such pipes. Inspectors found drain pipe near galley preparation station port side wasted and missing section to the through hull fitting. Through hull fitting had no valve or means to stop water ingress from sea. Pipe drain led directly into ships void space/galley preparation area. Submit repair proposal prior to repair to local OCMI.
46 CFR 56.50-95 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2025
Resolution: Recvd picture of valve install on ovbd discharge piping, sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 February 2025
Resolved
Flaking and scaling of hull steel next to the Keel was observed in Void 4 (Freshwater Void), and under the Galley in the bilge two frames forward of access hatches. descale and take pictures of cleaned steel.
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Recieved pictures from representative showing descale and repainting of void.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 February 2025
Resolved
Deck railing on the 02 deck both port and starboard side were found with rusted stanchions. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2025
Resolution: Vessel fixed starboard side witnessed 05MAR, and Operator submitted photographs of the port side stanchion repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 February 2025
Resolved
Aft port lazarette to port fuel tank approx 10ft by 10ft steel hull plate was identified by vsl rep to be below threshold and will be cropped and renewed. Call outs for crop, fit up, back gouge, final and NDT required.
Action required: 705 - Other - as specified
Resolved 5 March 2025
Resolution: Attended vessel w/ representative. Conducted dye pen NDT and welds tested sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2024
No resolution recorded
"A vessel that is exposed to salt water more than three months in any 12 month period... must undergo a dry dock examination and internal structural at least once every two years..." Vessel lapsed its DDX/ISE inspection. Complete Credit DDX and ISE prior to carrying passengers.
46 CFR 115.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 January 2024
No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Nothing in this subpart limits the marine inspector from conducting such tests or inspections necessary to be assured of the vessel's seaworthiness. Vessel does not normally operate and was not prepared to carry passengers. Prior to carrying passengers notify the OCMI for an in service inspection. 46 CFR 115.500(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 January 2024
No resolution recorded
"Exercises must be conducted at least once each calendar year, with no more than 18 months between exercises." Vessel has not conducted a security drill or exercise since 2019. Prior to carrying passengers conduct security drills and exercise. 33 CFR 104.230(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 January 2024
No resolution recorded
The intent of this part is to insure that each vessel is provided with safe,readily available and sufficient firefighting equipment of the type necessary to extinguish any fires which are likely to be encountered in normal operation. Galley appliances did not shut down while sea safety was testing galley range hood Ansul system. Prior to using galley demonstrate proper operation of system shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 January 2024
No resolution recorded
Before getting underway, the master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided in a manner which affords all passengers the opportunity to become acquainted Vessel does not have a public announcement on board. Rectify prior to carrying passengers. 46 CFR 185.25-1(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 January 2024
No resolution recorded
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of
the boat. Battery in engine room on the port side was found not to be properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 January 2024
No resolution recorded
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of
the boat. Battery in the bridge under the operating station was found to not be mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 January 2024
No resolution recorded
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck. Emergency lighting in galley was not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 January 2024
No resolution recorded
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI found unauthorized power strip connected to the surge protector, overloading the power strip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2024 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 April 2023
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following:(1) The location of emergency exits, survival craft embarkation areas, and ring life buoys;(2) The stowage location(s) of life jackets;(3) Either:(i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or(ii) That passengers may contact a crew member for a demonstration as appropriate,(4) The location of the instruction placards for life jackets and other lifesaving devices;(5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and(6) If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter.
Vessel's passenger safety orientation script did not include all of the required information.
46 CFR 185.506(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 2 May 2023
Resolution: Resolved via pictures.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2023
Resolved
All portable fire extinguishers installed on vessels shall be of an approved type.
Portable fire extinguisher on the bridge lacked appropriate bracket to qualify it as a type approved marine fire extinguisher.
46 CFR 181.30-5, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 2 May 2023
Resolution: Resolved via pictures.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 April 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
No portable extinguishers are being subjected to monthly inspection.
46 CFR 176.810(b), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 2 May 2023
Resolution: Resolved via pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2021
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Terminal end of conductor in the pump area of the engine room bare and not in enclosure. Provide enclosure or remove conductor, located in pump area below engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 30 March 2021
Resolution: Dead end wire was placed into an enclosure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2021
Resolved
Door frames shall be of rigid construction, and shall provide at least a 1/2 inch door stop at the sides and top. Gap spacing in excess of allowance and does not provide a 1/2 inch stop. Replace in accordance with 46CFR 72-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 30 March 2021
Resolution: New fire door and door frame was installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 February 2020
Resolved
The discharge valve on the fire main is leaking and needs to be repaired.
Cite: 46CFR181.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 10 February 2022
Resolution: valve and surrounding piping were replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 February 2020
Resolved
Flexible fuel hose on stbd main engine is chafed and needs to be replaced. Chafing material needs to be removed from fuel hose on both main engines.
Cite: 46CFR182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 10 February 2022
Resolution: chafing material removed and replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2020
Resolved
Galley hood suppression system needs to shut off power to appliance. Pressure system is not wired.
Cite: 46CFR
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 11 February 2022
Resolution: new supression system was installed and wired to turn off appliance in the event of a fire
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2020
Resolved
A vessel's hull must not carry current as a conductor, ensure ground found on port heater is rectified.
Cite: 16CFR183.370(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 10 February 2022
Resolution: ground on port heater was rectified
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 February 2020
Resolved
C/R to good metal, bottom plate and frame in stbd side of galley bilge crawl space approximately at the midsection of the space as discussed and marked.
Action required: 705 - Other - as specified
Resolved 14 February 2020
Resolution: Witnessed satisafactory repair process.
Electrical › Electric Generation Source (service) › Generator
Issued 24 January 2017
Resolved
Permanently repair the generator drainage pipe in engine room space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 4 April 2017
Resolution: A marine inspector attended the vessel and verified the drainage pipe repair in the engine room.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 January 2017
Resolved
Replace float light battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2017
Resolution: The vessel's owner provided the proper battery for the light during the inspection.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 24 January 2017
Resolved
Submit repair proposal for proper installation of shore tide connection.
Due 24 February 2017
Resolved 4 April 2017
Resolution: A CG Marine Inspector went to verify that proper installation of shore tide connection was completed.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 5 January 2016
Resolved
Install relief valve on air receiver in pilot house.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 29 January 2016
Resolution: Attended vessel, verified installation of pressure relief valve
Communications › Radio Communications › Emergency Source of Power
Issued 5 January 2016
Resolved
Radios do not work on back up power prove proper operation on back up power.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 12 January 2016
Resolution: Operator provided official statement attesting to the replacement of battery and operational test.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 January 2016
Resolved
Emergency lights in E/R inop. prover proper operation.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 29 January 2016
Resolution: Attended vessel, verified emergency lighting is operational.