05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 18 February 2025
Resolved
Vessel must comply with applicable requirements for any radio as set forth in 47 CFR part 80. Vessel must have a DSC-capable radiotelephone (VHF) at the operating station. Vessel VHF is not connected to position indicating device (GPS)to fulfill DSC requirement.
46 CFR 184.502
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2025
Resolved 19 February 2025
Resolution: Received a satisfactory third-party technician’s report attesting that the VHF radio at the forward operating had been integrated into GPS and that the MMSI number was input properly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 February 2025
Resolved
Protection from mechanical damage shall be considered, with shields installed to the satisfaction of the [name withheld] filter on #01 Port MDE had bowl other than steel construction, and was not protected with flame bowl/shield.
46 CFR 182.40-1 (a)(ii) (2)('Old' T)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2025
Resolved 19 February 2025
Resolution: #01 Port MDE had flame bowl/shield installed.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 18 February 2025
Resolved
Owners and operators of applicable vessels must establish a master key control system and related provisions for use of master keys, and record keeping. Vessel does not currently have a master key control system.
46 USC 3106(a)(1)
CVC Policy Letter 23
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2025
Resolved 19 February 2025
Resolution: Vessel's policy is that it will utilize keyless locks for compliance. Vessel changed locks to keyless.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 February 2025
Resolved
Gauges to indicate lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. The oil pressure gage for the starboard outboard MDE gave incorrect readings.
46 CFR 182.20-5
('Old' T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2025
Resolved 19 February 2025
Resolution: The sending unit for the gauge was changed, and the gauge is now working satisfactorily.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 18 February 2025
Resolved
A manned, oceangoing ship of 40 feet or more must have a garbage management plan that describes procedures for minimizing, collecting, processing, storing and discharging garbage, and designates a person in charge to carry out the plan. Vessel could not produce a garbage management plan.
33 CFR 151.51(d)
33 CFR 151.57
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2025
Resolved 6 March 2025
Resolution: A waste management plan for the vessel that was satisfactory to the requirements was provided and placed within the deficiency documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 February 2025
Resolved
Owner/operator shall be prepared to conduct tests of its fire protection equipment, to include fire detection systems. Last proof of test of fire detection system was from 2023. Service tech attended, tested, and attested to satisfactory operation of the fire detection system.
46 CFR 176.810 (a)
Action required: 10 - Deficiency Rectified
Due 18 February 2025
Resolved 18 February 2025
Resolution: Service tech attended, tested, and attested to satisfactory operation of the fire detection system. Report attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2025
Resolved
At all inspections the marine inspector shall pay special attention that no fire hazards exist. The port outboard MDE (#01) was found to have an active fuel leak. A third-party technician attended rectified the source of the leak, and the hazard corrected prior to inspector departure.
46 CFR 176.25-10(b)
('Old' T)
Action required: 10 - Deficiency Rectified
Due 18 February 2025
Resolved 18 February 2025
Resolution: Third-party technician attended rectified the source of the leak, and the hazard corrected prior to inspector departure.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 February 2025
Resolved
Adequate emergency lighting shall be installed along the line of escape. The emergency light located above the switchboard was extinguished. The bulb was replaced and the hazard was corrected prior to the inspectors departing the vessel.
46 CFR 184.30-5
('Old' T )
Action required: 10 - Deficiency Rectified
Due 18 February 2025
Resolved 18 February 2025
Resolution: The bulb was replaced and the hazard was corrected prior to the inspectors departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 February 2025
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Support bracket for the exhaust for the port generator was missing hardware and not supported. Missing hardware was replaced and the support bracket was fastened in place prior to inspectors departing the vessel.
46 CFR 182.10-1
('Old' T)
Action required: 10 - Deficiency Rectified
Due 18 February 2025
Resolved 18 February 2025
Resolution: Missing hardware was replaced and the support bracket was fastened in place prior to inspectors departing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 29 February 2024
Resolved
EACH WINDOW, PORT HOLE, AND ITS MEANS OF ATTACHMENT TO THE HULL OF DECK HOUSE, MUST BE CAPABLE OF WITHSTANDING THE MAXIMUM LOAD FROM WAVE AND WIND CONDITIONS EXPECTED DUE TO ITS LOCATION ON THE VESSEL AND THE AUTHORIZED ROUTE OF THE VESSEL. WINDOW AFT OF PILOT HOUSE ON THE STARBOARD SIDE HAS A CRACK EXTENDING FROM ONE TOP CORNER TO THE ADJACENT LOWER CORNER.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2024
Resolved 10 May 2024
Resolution: Marine Inspectors determined that the crack in the window does not pose any stability, watertight, or safety concerns to the vessel's operation. Deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Facilities for reception of marine safety inform.
Issued 29 February 2024
Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO INSTALLATIONS , INCLUDING THE REQUIREMENTS FOR A STATION LICENSE AND INSTALLATION CERTIFICATE TO BE ISSUES BY THE FEDERAL COMMUNICATIONS COMMISSION.
WHEN USING DSC TECHNIQUES, COAST STATIONS AND SHIP STATIONS MUST USE MARITIME MOBILE SERVICE IDENTITIES (MMSI) ASSIGNED BY THE COMMISSION OR IT DESIGNEES.
SHIP STATION DID NOT HAVE MMSI PROGRAMMED.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2024
Resolved 29 February 2024
Resolution: MMSI was programmed into VHF radio prior to inspectors departing vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 February 2024
Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS. MULTIPLE APPLANCES WERE PLUGGED INTO SURGE PROTECTOR ON BILGE. CIRCUIT BREAKER IN ENGINE ROOM MISSING BLANKS. DEAD END WIRING ON STARBOARD GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2024
Resolved 29 February 2024
Resolution: Blanks were installed in distribution panel, and surge protector was removed after inspector's vessel departure. Vessel rep sent pictures.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 February 2024
Resolved
THE CERTIFICATE OF INSPECTION MUST BE POSTED UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL, SUCH THAT ALL PAGES ARE VISIBLE, IN A CONSPICUOUS PLACE ON THE VESSEL WHERE OBSERVATION BY PASSENGERS IS LIKELY. VALID COI WAS NOT POSTED UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 March 2024
Resolved 29 February 2024
Resolution: Vessel rep posted COI on bridge under glass after vessel inspection was completed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 January 2023
Resolved
Exposed hazards must be properly protected by a cover, rail, or guard. Air compressor needs guard over fan. – 46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2023
Resolved 18 January 2023
Resolution: An appropriate cover was put into pace to the satisfaction of the attending Coast Guard Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023
Resolved
Watertight penetrations must be made watertight. Numerous penetrations in FWD E/R not watertight.– 46 CFR 179.320
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2023
Resolved 18 January 2023
Resolution: Through bulkhead penetrations were made/repaired satisfactory to the attending Coast Guard Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 January 2023
Resolved
Vessel must be provided with life floats to accommodate at least 100% of the persons on board. Vessel has inadequate amount of lifesaving equipment, reduce passengers o 46 until addt. equipment installed. -– 46 CFR 180.202(b)(2)
Action required: 705 - Other - as specified
Due 17 January 2023
Resolved 29 February 2024
Resolution: Vessel is equipped with life floats to accomodate 100% of persons on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 January 2023
Resolved
The materials and construction of fuel lines must comply with the requirements of this paragraph. Fuel line on starboard generator was worn and contained an improper fitting (hose clamp). Replace. - 46 CFR 182.455
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: Fuel line/fittings were renewed satisfactory to the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2023
Resolved
Irrespective of build date, vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with Part 181.450 that is installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel currently has modular detectors and will required an interconnected system as described. - 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 14 July 2023
Resolution: Vessel Rep. provided sufficient documentation to MSU Houma in the form of a technician’s report to clear the outstanding requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 January 2023
Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil shall be provided for all propulsion engines and located in view of the operator. The starboard outboard (M/E #4) jacket water temperature sensor was inoperable and needs repair.
An RPM gauge for the same M/E was at the operating station and inoperable. The RPM gauge is not required and should either be repaired or removed.- 46 CFR 182.20-5(b)(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: An electrician attended the vessel and repaired the issue with the gauge. Operation witnessed/ satisfactory to the attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023
Resolved
Electrical equipment on a vessel must be installed to protect passengers/crew from electrical hazards to include electrical shock. A breaker panel in the forward engine room is missing two blanks.
A motor controller for the fuel pump has an opening where the start button is pushed in.
A motor controller from a removed oily water separator remains on board. Remove or ensure that it is de-energized.- 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: An electrician attended the vessel and disconnected the OWS motor controller from the breaker panel. Blanks were added to the breaker panel, and missing buttons on the fuel pump were renewed satisfactory to the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 January 2023
Resolved
At each inspection for certification of a vessel the Owner/Operator shall be prepared to conduct tests of its fire protection equipment to include the fire main system. The fire main has a leak at a union on the discharge outlet near the fire pump in the engine room. - 46 CFR 176.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: The fire pump was energized/pressurized and no leaks on the outlet were detected. Satisfactory to the attending USCG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023
Resolved
Ground detection must be provided for or an alternating current system. Ground detection located on switchboard is inoperable.- 46 CFR 183.324
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: An electrician attended the vessel and the ground detection was made satisfactory to the attending USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 January 2023
Resolved
Each lighting fixture globe must have a guard. Two emergency lights in the have engine room were missing protective guards. - 46 CFR 183.410(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 18 January 2023
Resolution: Guards were put into place to the satisfaction of the attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 January 2023
Resolved
At each inspection for certification of a vessel the Owner/Operator shall be prepared to conduct tests of machinery to include generators. The independent overspeed device installed on the starboard generator was inoperable. - 46 CFR 176.804
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: The independent overspeed device installed on the starboard generator was replaced to the satisfaction of the attending USCG Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2023
Resolved
A Vessel must carry a first aid kid that meets the requirements of 46 CFR 199.175(b)(10). On board first aid kits are either expired or contain expired items. Replace. - 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 17 February 2023
Resolution: Attending USCG Marine Inspector verified a new First Aid kit was onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 January 2023
Resolved
Each ring life buoy with a floating water light must have a lanyard of at least 3 feet but not more than 6 feet. The port side ring life buoy on the main deck has a 9-10ft. lanyard and needs to be shortened to meet the required length. - 46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 18 January 2023
Resolution: The floating water light lanyard was made to the correct length, and to the satisfaction of the attending USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 January 2023
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck. Forward engine room emergency light was inoperable. An incorrect bulb was installed and was replaced with the correct type. - 46 CFR 183.432
Action required: 10 - Deficiency Rectified
Due 17 January 2023
Resolved 17 January 2023
Resolution: An incorrect bulb was installed and was replaced with the correct type to the satisfaction of the attending USCG Marine Inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 August 2022
Resolved
NO vessel may be navigated unless it has in its service and onboard the crew complement requried. Master has a revoked license and expired TWIC. One (01) deckhand has an expired TWIC without proof of renewal.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 August 2022
Resolution: Vessel had a licensed Credentialed Master.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2022
Resolved
On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in 182.530: on a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station.
46 CFR 182.115
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2022
Resolution: Verified working audible/visual high level bilge alarms.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 April 2022
Resolved
Vessels operating between 100-200 from shore must have an SSB and NAVTEX. Vessel had inopperable SSB and NAVTEX.
47 CFR 80.905
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
Resolution: Electrician came to fix wiring. Verified working condition of equipment
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 April 2022
Resolved
Vessel did not have chart correction kits on board.
46 CFR 176.05-10 OLD T
Action required: 10 - Deficiency Rectified
Resolved 29 April 2022
Resolution: Vessel agreed to take notes in notebook, while waiting for out of stock chart correction kit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2022
Resolved
Each EPIRB must be tested monthly and shall be logged. Vessel was not logging EPIRB tests.
46 CFR 185.728
46 CFR 185.25-20 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
Resolution: Vessel logged and tested EPIRB tests monthly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2022
Resolved
Electrical equipment on a vessel must be installed a maintained to... Minimize accidental peronnel contact with energized parts and prevent electrical ignition of flammable vapors. Vessel had open junction box above switchboard in engine room.
46 CFR 183.200
46 CFR 183.01-5 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
Resolution: Junction box was properly covered.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2022
Resolved
Electrical equipment on a vessel must be installed a maintained to... Minimize accidental peronnel contact with energized parts and prevent electrical ignition of flammable vapors. Vessel had deadend wires in pilot house.
46 CFR 183.200
46 CFR 183.01-5 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
Resolution: Deadend wires were removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2022
Resolved
All life preserver must be marked with the vessel's name. A life preserver was not marked appropriately.
46CFR185.30-5 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2022
Resolution: Stenciled vessel name on life preserver
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2022
Resolved
Shutoff valves, shall be fitted in the fuel supply lines with one at the engine end of the fuel line to stop fuel flow. None of the engines had shutoff valves.
46CFR182.20-40 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2022
Resolution: Shut off valves were installed at the engine.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2022
Resolved
Flexible hose may be used provide it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils, and vibrations. Fuel hose did not have a suitable connection.
46 CFR 182.20-40 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 May 2022
Resolution: Made proper connection with double clamps
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 17 June 2021
Resolved
Vessel is being detained due to repeated non-conformity to regulations and consecutive violations of observed unsafe practices, fire hazards, and other hazardous situations. 46 CFR 176.830(a)
Action required: 30 - Ship detained
Resolved 30 June 2021
Resolution: MI's attended vessel to conduct def check at the request of vsl rep. Vsl was found in good material condition with knowledgable crew.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 June 2021
Resolved
Self-priming, power driven fire pump must show a pressure of not less than 60 psi at the fire pump outlet. Fire pump failed to reach sufficient pressure and a leak was discovered at the fire pump. The pump was not self priming and required the introduction of water to prime during first start. 46 CFR 181.300(b); 46 CFR 181.120(a)
Action required: 30 - Ship detained
Resolved 30 June 2021
Resolution: Vsl replaced fire pump and portions of fire main piping. Function test conducted in conjunction with fire drill. Pressure gauge satisfactorily reached 62 psi.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 June 2021
Resolved
Master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with his or her duties in case of fire. Master and crew failed to take initial response actions, maintain proper communications, advise and direct potential passengers of emergency, successfully secure fuel and ventilation, or successfully combat the fire. The drill was not conducted to reflect expected response to an actual emergency. 46 CFR 185.524(a)
Action required: 30 - Ship detained
Resolved 30 June 2021
Resolution: Conducted satisfactory fire drill with vsl crew.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 17 June 2021
Resolved
Master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate the recovery of persons who have fallen overboard. Master and crew failed to don proper lifesaving equipment, including rescue swimmer harness and securing the swimmer to vessel, and master would frequently leave operating station unattended to issue commands to crew on back deck while vessel was simulated to be underway. The drill was not conducted to reflect expected response to an actual emergency. 46 CFR 185.520(a)
Action required: 30 - Ship detained
Resolved 30 June 2021
Resolution: Conducted satisfactory MOB drill.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 17 June 2021
Resolved
The minimum number of mariners holding a license or MMC officer endorsement as mate required to be carried on every inspected, self-propelled, seagoing, and Great Lakes vessel, and every inspected, seagoing, passenger vessel must be not less than the following, except when reductions are authorized under paragraph (e.) of this section: All vessels of less than 100 GRT-one mate (except when vessels on voyages not exceeding 12 hours in duration may, if the OCMI determines it to be safe, be operated without mates; Vessel operated in excess of 12 hours, on 6 separate days as reflected in vessel logs, with only a master and 2 deckhands.
46 CFR 15.810(b)(4)
Action required: 30 - Ship detained
Resolved 30 June 2021
Resolution: Vsl has remained at pier since annual inspection on 17Jun. MI will create special note for attention of future inspectors.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 June 2021
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drills were not being properly logged on the vessel since vessel obtained log book following previous September Annual inspection. 46 CFR 185.520(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2021
Resolution: Drill have been conducted and logged daily since detention on 17Jun. Special note created for attention of future inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2021
Resolved
Each life float must be fitted with a light IAW 46 CFR 161.010. The light was inoperable at the time of inspection and testing. Light was replaced by crew.
46 CFR 180.175(d); 46 CFR 180.175(f)(4)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Vessel rep acquired functional life float life from nearby marine supply store. Installed and secured light to life float to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 June 2021
Resolved
Each life float must be stowed with the float-free link being secured to the painter at one end and to the vessel on the other end. The top port side life float (15 man) painter line was not attached to the weak link or the life float below it (22 man). 46 CFR 180.137(b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2021
Resolution: Lifefloats were attached to each other with a line around each body, and bottom most lifefloat tied off to the weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 June 2021
Resolved
Each life float must be attached around the body of the life float. No life float lights were not attached around the body at the time of inspection. The life float lights were secured around the body of the life float prior to the MIs departure. 46 CFR 180.175(f)(4)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Life float lights were secured around the body of all life floats to the satisfaction of the MI prior to team departure.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 June 2021
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float. Both port life floats and the bottom starboard life float were not properly stenciled. 46 CFR 185.604(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Vessel crew stenciled the name of the vessel on all three new lifefloats to satisfaction of MI.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 June 2021
Resolved
Master of the vessel shall ensure each EPIRB is tested monthly and the EPIRB tests are logged or documented. Vessel master could not produce any record of monthly tests and had no documented tests in vessel’s Log Book.
46 CFR 185.728(a); 46 CFR 185.728(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2021
Resolution: EPIRB tests have been conducted weekly and logged since detention on 17Jun. Special note created for attention of future inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 June 2021
Resolved
The EPIRB NOAA registration sticker must be marked on the EPIRB. The sticker on the EPIRB was expired, vessel owner has updated registration forms and is expecting new sticker in the mail by 24JUN21. 47 CFR 80.1061(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: EPIRB sticker was received by vsl rep and attached to EPIRB body.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 June 2021
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in the view of the operator. Gauges at the operating station were inoperable.
46 CFR 182.15-5 (OLD T)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2021
Resolution: Gauges were installed and function tested satisfactory with engines.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 June 2021
Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. Diesel fuel was discovered pooled on the outboard starboard engine on the fuel filter housing. 46 CFR 182.01-5 (OLD T)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Vessel crew used sorbent pads to clean top of fuel filter housing and ensured fuel filter was properly installed. No leakage was detected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021
Resolved
The vessel shall be ready for inspections of machinery essential to the routine operation of the vessel including generators and cooling systems. A water leak was discovered over the outboard port engine exhaust. 46 CFR 176.804(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: Vsl replaced fitting and tightened gasket around piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021
Resolved
The vessel shall be ready for inspections of machinery essential to the routine operation of the vessel including generators and cooling systems. A coolant leak was discovered on the starboard generator. 46 CFR 176.804(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: Gasket on generator cooling water piping system was replaced satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 June 2021
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. A lighting fixture guard was missing over the starboard generator. 46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: Vsl replaced lighting fixture satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 June 2021
Resolved
Charts and publications must be appropriate for the intended voyage and must be adequate and up to date. The charts on board were not maintained and up to date in accordance with the recent notice to mariners. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: New charts which were received have been maintained up-to-date with LNM. Special note created for attention of future inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2021
Resolved
That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. Lagging between MDE #3 (starboard inboard engine) and point of water injection had a missing section of lagging. 46 CFR 182.20-15(OLD T)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Vessel crew properly applied and securing lagging over exposed section of exhaust piping before point of water injection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and other persons. Exposed electrical wiring was discovered in the vessel’s accommodation spaces head. 46 CFR 183.200(b)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Vsl rep properly capped dead end wires with wire nuts and taped wires using electrical tape.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 17 June 2021
Resolved
Sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range; sea rails were not installed on the stove at the time of the inspection. 46 CFR 184.220(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2021
Resolution: Sea rails were installed to the satisfaction of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2021
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date; Vessel scheduled their inspection beyond inspections window.
46 CFR 176.500(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 17 June 2021
Resolution: Had in-depth discussion with vessel rep. and master about anniversary date and properly scheduling annual inspection during +/- 3 months window of anniversary date. Vsl rep acknowledged clarity on the proper procedure and timing for annual inspection.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 September 2020
Resolved
Vessel shall ensure that all firefighting equipment shall be ready for use at all times. All fire stations (2) were disconnected with nozzles removed.
Action required: 10 - Deficiency Rectified
Due 10 September 2020
Resolved 10 September 2020
Resolution: Vessel connected both fire stations to be ready to use at all times.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 September 2020
Resolved
Vessel shall undergo an annual inspection within 3 month
before/after anniversary date of COI. Vessel exceeded
the 3 months window by 85 days.
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
Resolution: Vessel completed annual exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Starboard side generator has exposed junction box containing exposed electrical wires.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel removed the exposed junction box.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Grease/Oil build-up on starboard side generator winding poses a fire hazard.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel cleaned the grate and scraped off the worst of the oil and dust from the winding. Recommended, not required, to test (meg) the generator.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2020
Resolved
Vessel's machinery shall be installed and maintained in a manner to afford adequate protection against fire. Port aft engine room supply fan caked in oil.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel cleaned the fan of the accumilated oil to the satisfaction of the Coast Guard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Outlet cover plate missing in forward centerline of engine room.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Replaced cover that was missing.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. The four life floats on board are missing or has illegible name of the vessel on them.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessels name was clearly stensiled on all four (4) life floats
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. The four life floats on board are missing or has illegible markings for personnel capacity.
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2020
Resolved 10 September 2020
Resolution: Life float capacity was clearly stensilled on all life floats.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 September 2020
Resolved
An independent modular smoke detecting unit must: Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector—Also suitable for use in Recreational Vehicles,” or other standard specified by the Commandant; Contain an independent power source; and Alarm on low power. Modular smoke detector on bridge did not sound alarm when tested.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel installed new smoke detector on bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The light must be a floating water light approved under approval series 161.010 or other standard specified by the Commandant. The inboard starboard side water light attached to one of the life floats is painted over, reducing its effectiveness.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel installed new water light for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The pendants or "hanks" on the top most starboard side life float has deteriorated/frayed line.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel had all pendantes replaced on life floats.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 September 2020
Resolved
Visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. Bilge alarm for the lazarette did not produce an audible alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel attached a loose wire and both light and auditory alarm sounded for the lazarette bilge alarms.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 September 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date installed. Hydrostatic release for EPRIB was not marked with expiration date.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel installed new hydrostatic release and marked the new release with the exiration date.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020
Resolved
Vessel shall maintain the life buoys to be ready accessible. Port side ring bouy line is frayed and needs to be replaced. The line for the floating waterlight was tied into knots.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel replaced the lines for the port life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 September 2020
Resolved
Vessel shall maintain the batteries to the generators to ensure that the generators have the ability to start. The batteries on the port side generator were dead requiring the port generator to be jump-started.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 10 September 2020
Resolution: New batteries were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 8 September 2020
Resolved
Vessel is required to afford adequate precaution against hazards that might endanger the vessel and persons. The chest freezer and dryer need to be secured to prevent movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2020
Resolved 10 September 2020
Resolution: Freezer and dryer were secured to the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; #4 Diesel engine had 3 dead end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2020
Resolved 10 September 2020
Resolution: Vessel removed all dead end wire from all engines.
05 - Radio Communications › N/A - No Subsystem › Maintenance/duplication of equipment
Issued 8 September 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Vessel mast had three dead end wires and were supported by plastic ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2020
Resolved 10 September 2020
Resolution: Vessel removed the three dead end wires.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 September 2020
Resolved
Vessel shall carry adequate and up-to-date charts. Vessel purchased new charts dated 31AUG2020 and had not updated the charts. Master informed MI that they do not update the charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2020
Resolved 12 January 2021
Resolution: Vessel obtained updated charts.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 September 2020
Resolved
Vessel shall maintain a ships's log that includes: Training; drills; Monthly EPIRB tests; Pre-underway checks, including steering gear, control, and communication.
46 CFR 185.320
46 CFR 185.420
46 CFR 185.520
46 CFR 185.524
46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2020
Resolved 12 January 2021
Resolution: Vessel obtained Log book
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 September 2020
Resolved
Vessel shall ensure that the fire pump is readily available and sufficient to extinguish any fires. Vessel's fire pump was leaking, showed 58 PSI with signifcant leaks and needed to be primed to operate.
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
Resolution: Vessel secured the leaks to the fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 September 2020
Resolved
Vessel shall ensure the operation of covers to prevent the admission of air into the engine and/or generator spaces protected. Vessel engine and generator room vent covers were not able to be moved without mechanical means due to being stuck from paint.
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
Resolution: Vessel used a prybar to loosen the vent covers. Vent covers were able to operate freely.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2020
Resolved
Vessel shall ensure operation and maintenance of emergency lighting. Both emergency lights in engine room bulbs did not operate due to the bulbs being extinguished.
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
Resolution: Vessel changed the bulbs in the emergency lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Alcohol Test Strips expired. Replace with non expired test strips
46CFR 185.212/4.06-5
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: New test strips bought and onboard VSL
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 4 June 2019
Resolved
VSL is not maintaining VGP logs IAW CG-543 Policy Letter 11-01 VGP 5.2.2.1
[name withheld]
[phone withheld]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 4 June 2019
Resolution: The VSL was informed of the requirement to maintain ballast water records IAW the operative section of 33 CFR 151
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 June 2019
Resolved
Bilge Alarms are not operating properly. Ensure alarms have visual and audible indicator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 4 June 2019
Resolution: Alarms were improperly wired, VSL corrected and alarms are operational
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 June 2019
Resolved
Lifering Buoy and Life float reflective tape is worn and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: New reflective tape put on the life floats and life ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2019
Resolved
Fire axe is not properly mounted.46CFR 181.35-1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: Fire axe mounted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 June 2019
Resolved
Pressure VSL relief valves are not properly set. Have safety relief valves tested.
46CFR54.15-10
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 5 June 2019
Resolution: Safety rellief valves tested and set to 150psi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 June 2019
Resolved
Starboard Pressure Vessel gauge is not sufficient for the Size of the PV. Replace with gauge of sufficient size.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 5 June 2019
Resolution: Pressure Vessel Gauge replaced with 200psi gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2019
Resolved
Exhaust lagging missing from MDE exhausts, replace lagging on exhausts.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: Exhaust lagging placed on exhausts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2019
Resolved
Rescue platform needs to be secured to the vessel and a length of line to be used for rescue swimmer.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: Chain placed on rescue platform to secure it to the VSL and a line made for the rescue swimmer.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 June 2019
Resolved
Smoke detectors are not operating in VSL spaces, ensure operation of all smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2019
Resolved 5 June 2019
Resolution: Smoke detectors operating
Documentation › Certificates/Documents › Permit, Other
Issued 7 March 2018
Resolved
Radio operator permit was not held by any of the crew members.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 7 March 2018
Resolved
Provide proper operation of VHF radios. Main VHF does not provide clear communication within a 3 mile radius, second VHF does not provide communication.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 March 2018
Resolved
Expired first aid kit.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 March 2018
Resolved
Repair hydraulic leak under pilot house control station.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 March 2018
Resolved
Provide updated charts, coast pilot, tides and currents.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 March 2018
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 March 2017
Resolved
Provide adequate and up-to-date charts and pubs to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 March 2017
Resolved
Post COI.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Documentation › Certificates/Documents › Stability Letter
Issued 22 March 2017
Resolved
Post stability letter.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 22 March 2017
Resolved
Provide day shapes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2017
Resolved 29 March 2017
Lifesaving › Lifefloat › Serviceable
Issued 22 March 2017
Resolved
Fix 15 pass. Inserviceable lifefloat on port side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 22 March 2017
Resolved
Label fwd emergency escape hatch "Emergency Exit, Keep Clear".
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Engineering › Fuel Oil Service System › Hose
Issued 22 March 2017
Resolved
Replace non-metallic piping/fuel hoses on port and stbd generators.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 29 March 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 March 2017
Resolved
Fix exhaust leak on port exhaust of port inboard main diesel engine. Replace nonmetallic piping on exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 March 2017
Resolved
Provide satisfactory operation of water tight door indicating light.
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 29 March 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 March 2017
Resolved
Complete Annual Inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2017
Resolved 22 March 2018
Electrical › Electric Generation Source (service) › Generator
Issued 1 March 2016
Resolved
DEMONSTRATE PROPER INSTALLATION AND OPERATION OF ALL GENERATORS, OVERSPEEDS, AND AND SAFETY INTERLOCK DEVICES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TO BE CORRECTED PRIOR TO MOVEMENT.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 4 March 2016
Resolution: Fuel line replaced, generator ran and tested SAT.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 March 2016
Resolved
DEMONSTRATE PROPER OPERATION OF ALL EMERGENCY LIGHTING ARRANGEMENTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TO BE CORRECTED PRIOR TO MOVEMENT.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 4 March 2016
Resolution: Battery replaced.
Engineering › Bilge Water Management System › Pump
Issued 1 March 2016
Resolved
PROVIDE PROOF OF PROPER INSTALLATION AND OPERATION OF BILGE PUMP TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR. TO BE CORRECTED PRIOR TO MOVEMENT.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 4 March 2016
Resolution: Bilge pump replaced.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 March 2016
Resolved
CONDUCT DRILLS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR. TO BE CORRECTED PRIOR TO MOVEMENT.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 4 March 2016
Resolution: Drills were conducted SAT.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 March 2016
Resolved
REPAIR OR REPLACE CONNECTIONS ON TERMINALS ON BATTERIES IN ENGINE ROOM TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 4 March 2016
Resolution: Wires were repaired.