ESSAYONS

ESSAYONS is a 1983 industrial vessel. The Coast Guard has recorded 172 inspections since 1985, most recently in June 2026, along with 186 deficiencies and 12 casualty investigations between 2005 and 2026.

Records from 1985 to 2026. Most recent: inspection, 21 June 2026.

Built
1983
Last inspected
21 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7923495 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
240799
Flag
UNITED STATES
—
Maury page id
psix-240799

Inspections, by type

…with no type recorded38
Years with a record 40 calendar years (1985–2026)
The 172 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it7409 - Dead Weight, Ton
14000 - Displacement, Ton
7248 - Regulatory (Subpart C or D), Gross Ton
4699 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DELPHINUS C Freight Ship · MISLE 936380 · 26 July 2023 · activity 7764384YAQUINA Industrial Vessel · MISLE 52557 · 4 November 2019 · activity 6848824OCEAN UNITY Freight Ship · MISLE 248448 · 14 March 1992 · activity 113864

Inspection history · 172

21 June 2026 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8416533
5 March 2026 In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8321329
4 December 2025 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8277806
31 March 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8103296
24 July 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7966354
1 July 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7946757
16 April 2024 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7897007
15 December 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7839649
23 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7775491
2 August 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7758908
26 July 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7764384
3 July 2023 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7736122
31 May 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7702322
22 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7655700
1 November 2022 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7587827
1 November 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7590586
2 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7466299
2 May 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7444787
3 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362168
9 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7290555
9 July 2021 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7251068
22 March 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7160950
16 December 2020 In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7112950
27 July 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7025629
18 May 2020 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6955433
4 May 2020 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6948049
23 December 2019 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6883554
8 November 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6852367
4 November 2019 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6848824
10 July 2019 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6748266
2 July 2019 In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6734055
15 June 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6717738
30 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6709822
15 March 2019 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6641220
4 December 2018 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6592409
27 August 2018 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6524311
19 July 2018 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6484980
20 June 2018 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6450966
24 May 2018 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6422861
20 April 2018 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6397925
6 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6386234
3 December 2017 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6315766
12 October 2017 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6287354
8 September 2017 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6276273
3 May 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6138448
10 April 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6129762
20 December 2016 Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6060719
12 August 2016 Plan Review (Other than "T")
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6042619
19 July 2016 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5946384
22 June 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 5916580
2 May 2016 Deficiency Check · In-Service Inspection · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5867707
1 December 2015 Examination of Repairs · Periodic Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5792900
12 August 2015 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5108910
2 October 2014 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4997822
6 July 2012 Examination of Repairs · Damage Survey
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4344888
5 June 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4343776
5 July 2011 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4079105
5 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4088720
3 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4088682
18 March 2010 Administrative Inspection · In-Service Inspection · Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3651434
4 March 2010 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3730201
28 July 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3548422
20 February 2009 Deficiency Check · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3345837
11 September 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3057032
10 April 2007 Internal Structural Exam · Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2861720
11 May 2006 Deficiency Check · Damage Survey
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2644820
7 April 2006 Damage Survey
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2617802
9 March 2006 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2557206
3 January 2006 Examination of Repairs · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2565765
5 August 2005 Damage Survey · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2447862
21 June 2005 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2397916
4 April 2005 Damage Survey
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2327762
3 April 2005 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2456068
25 February 2005 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2261295
14 January 2005 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2277380
2 March 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2016526
21 January 2004 Periodic Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1996036
8 December 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1948084
17 October 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1930788
13 August 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928880
28 April 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1901892
25 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1727535
12 November 2002 Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1704182
30 August 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1668785
30 May 2002 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1623777
22 February 2002 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1475544
11 July 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1068891
5 June 2001 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1066141
15 May 2001 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1063383
7 February 2001 Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410456
3 August 2000 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412153
29 July 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 143380
1 June 2000 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1050778
21 March 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1397347
1 February 2000 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1361275
21 July 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 773311
13 July 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1097380
28 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 100167
15 March 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 806939
9 March 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 804243
14 January 1999 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1397064
18 December 1998 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1378500
7 July 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453502
2 June 1998 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394979
17 May 1998 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790528
9 March 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372192
23 February 1998 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372137
22 October 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1113058
31 July 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1116898
3 June 1997 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 774064
21 May 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1102119
26 February 1997 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398631
1 February 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388217
28 June 1996 Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1353997
3 June 1996 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1185948
21 April 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 73590
7 March 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 90246
4 March 1996 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1422657
15 February 1996 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1377614
28 August 1995 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1186275
14 March 1995 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 863526
9 March 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1456248
16 December 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 841565
16 December 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1380131
17 November 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1178311
31 October 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 39743
25 August 1994 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1448576
23 August 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 45061
17 July 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 133310
6 June 1994 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1014553
16 May 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1170184
28 March 1994 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 858890
23 February 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1359695
29 December 1993 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 850554
9 December 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1358219
16 September 1993 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1471096
23 July 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 37883
7 June 1993 Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1152440
30 March 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1146620
4 March 1993 Examination of Repairs · COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1463752
3 February 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 652671
30 January 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 107487
22 September 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 38363
13 April 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 951173
9 April 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 949344
14 March 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 113864
10 February 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267313
8 January 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403515
22 November 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 943140
5 August 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 943139
23 July 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 941604
4 June 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1004165
28 May 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 921940
26 March 1991 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 928727
18 January 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213223
24 March 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1340191
16 February 1989 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 894867
22 November 1988 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213607
9 September 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1040608
3 March 1988 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1336486
17 February 1988 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 994847
25 August 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031205
5 May 1987 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1020295
27 April 1987 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1333023
18 March 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334376
4 March 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1005751
30 January 1987 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1006068
22 December 1986 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1001838
7 March 1986 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1298735
16 December 1985 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1294282
22 July 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 983445
19 February 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 980336

Deficiency record · 186

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 December 2025 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of the subchapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. Significant wastage identified in Aft Peak Ballast Tank and addressed by ABS Finding No. 234.1 with a due date of 04 April 2026. Vessel owner operator may: 1) repair excessive wastage (25% or greater) by ABS deadline of 04 April 2026 as per ABS Finding 234.1; repair excessive wastage (25% or greater) this availability; or engage with ABS for limited scope scantling assessment by ABS Engineering to ensure the overall wastage does not impair the vessel's structure (less than minimum required section modulus) due to the corrosion to defer ABS Finding 234.1 to December of 2026. 46 CFR 92.01-10(a)
Action required: 10 - Deficiency Rectified
Resolved 1 April 2026
Resolution: ABS Does not have an open or closed finding number for this deficiency. See activity 8334423
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 31 March 2025 Resolved
All cargo vessels are required to carry on each side of the vessel, lifeboats with an aggregate capacity sufficient to accomodate the total number of persons on board. At the time of our inspection, the starboard side life board was at a shoreside facility awaiting repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2025
Resolution: Repairs were made to the lifeboat's stern tube seal and hydraulic starter to the satisfaction of the attending OEM technician. Lifeboat was operationally tested and restowed aboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 March 2025 Resolved
The applicable standards established by the ABS Marine Vessel Rules may be used as the standard for testing of main and auxiliary machinery. At the time of our inspection the starboard SSDG was not operational, and the generator windings had been removed for repairs at a shore-side facility.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2025
Resolution: Generator windings have been replaced on the starboard SSDG and the generator has been fully tested, both singled-up and synchronized with the other SSDGS.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 July 2024 Resolved
Each cargo vessel must carry at least one rescue boat. The rescue boat davit's motor was removed for repairs, which are tentatively scheduled to be completed within the next 7-8 days. The ESSAYONS may use the launch/workboat located on the starboard side of the vessel as a temporary rescue boat IAW 46 CFR 199.640(g). The following restrictions are also required to be met: 1. The ESSAYONS is restricted to a coastwise route. 2. The launch/workboat shall not operate beyond the line of site of the vessel. 3. The launch/workboat shall carry the necessary rescue boat equipment outlined under 46 CFR 199.175 (Survival Craft Equipment). *** Permanent repairs to rescue boat must be made to the satisfaction of attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2024
Resolution: The Rescue Boat's jack-shaft bearing on the input shaft to the outdrive was replaced and the vessel was operationally tested to the satisfaction of the attending Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 March 2024 Resolved
Each vessel subject to load line requirements shall carry on board a valid certificate attesting to compliance with such requirements. Vessel's ABS issued load line certificate is expired. Vessel is not permitted to operate beyond the Mamala Bay, Hawaii boundary line, which is a line drawn from Barbers Point Light to Diamond Head Light until a valid ABS load line certificate is issued by ABS and a copy of the certificate is provided to the CG attending Marine Inspector. 46 CFR 92.01-5/ 46 CFR 42.09(b)
Action required: 705 - Other - as specified
Resolved 21 March 2024
Resolution: ABS issued a twelve (12) month Conditional International Load Line certificate valid from the original anniversary date with expiration 04 Jan 2025 with the current below remaining Statutory Conditions.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 March 2024 Resolved
Means shall be provided for closing all other openings to the space protected from outside such space. In this respect, relatively tight doors, shutters, or dampers shall be provided for openings in the lower portion of the space. The construction shall be such that openings in the upper portion of the space can be closed off either by permanently installed means or by the use of canvas or other material which is normally carried by the vessel. Bottom part of the machinery shop door frame and bulkhead is missing. Restore in-kind to meet the above regulation requirement for a CO2 protected space by December 13, 2024, to the satisfaction of the attending marine inspector. 46 CFR 91.15-35(c)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 29 January 2026
Resolution: Repaired to satisfaction of attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2024 Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter. Internal disc guides of the 18" cast steel overboard discharge gate sea valve for heat exchanger sea water, located in the forward heat exchanger room, port side directly above 1U Ballast tank top, were found generally corroded. Subject sea valve is to be repaired or replaced at the vessel's next dry dock on December 13, 2024, to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 90.20-1(a)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 31 March 2025
Resolution: Addressed during dry-docking at Vigor Shipyard and deemed acceptable by the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2024 Resolved
Nonmetallic expansion joints must conform to the standards listed in table 56.60–1(b) of this part. Provide objective evidence the two port and stbd 16” x 14” single sphere rubber expansion joints adjacent to the 16” Jetting Sea valve in the #2 Void and the two port and stbd 20” x 13” single sphere rubber expansion joints in the main saltwater header in the lower level Pump Room meet ASTM F 1123 standard by March 15, 2024, or replace with nonmetallic expansion joints that meet the adopted ASTM F 1123 standard at the vessel's next dry dock on December 13, 2024, to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 90.20-1(a) 46 CFR 56.35-10(b)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 11 March 2024
Resolution: Attended vessel to inspected the nonmetallic expansion joints Job 5.8.6 - Sea Valve Inspection for the ASTM F 1123 marks; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 28 February 2024 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. The #3S Wing Fuel Tank overflow piping located in the #12 U-void has a HYMAX 2 six inch coupling installed as a temporary repair. By the vessel's next dry dock on December 13, 2024: 1) Provide documentation the HYMAX 2 coupling is approved by the American Bureau of Shipping. 2) Provide documentation the HYMAX 2 coupling is approved for marine fuel oil system piping applications. 3) Return the #3S Wing Fuel Tank overflow piping back to its original design approval and installation at the vessel's next dry dock on December 13, 2024, to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 91.45-1(a)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 31 March 2025
Resolution: Addressed during dry-docking at Vigor Shipyard and deemed acceptable by the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 February 2024 Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. The #12 U-void fire main valve on stbd side leaking. Fix leak to the satisfaction of the attending Marine Inspector. 46 CFR 97.15-60(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 29 January 2026
Resolution: New valve and gaskets installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 February 2024 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making necessary test or inspections as deemed necessary.Descale and make available for re-inspection the #11 U-void port side deck forward under decommissioned hopper piping at vessel's next dry dock on December 13, 2024, for inspection. 46 CFR 91.25-50
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 31 March 2025
Resolution: Addressed during dry-docking at Vigor Shipyard and deemed acceptable by the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 6 February 2024 Resolved
a) Vessels in ocean, coastwise, or Great Lakes service, except unmanned barges, must be fitted with anchors. chains, and hawsers in general agreement with the Standards established by the American Bureau of Shipping. In addition to the provisions of paragraph (a) of this section, the following requirements and alternatives also apply: (1) The American Bureau of Shipping rules relating to anchor equipment are mandatory, not a guide. Both the port and stbd anchor chain have two chain links that are missing studs in the vicinity of the chain swivel IWO the anchor shank. Repair at vessel's next dry dock on December 13, 2024, to the satisfaction of the CG atending Marine Inspector. 46 CFR 96.07-5(a)(b)(1)
Action required: 705 - Other - as specified
Due 13 December 2024
Resolved 31 March 2025
Resolution: Addressed during dry-docking at Vigor Shipyard and deemed acceptable by the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 February 2024 Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. The #10 U-void stbd aft fire main ancillary line pipe nipple is wasted and leaking. Replace to the satisfaction of the attending Marine Inspector. 46 CFR 97.15-60(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 29 January 2026
Resolution: Repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 December 2023 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Each control valve to branch lines must be marked to indicate the related space served. CO2 system cylinders are not within the spaces protected. Provide a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate to the satisfaction of the attending Marine Inspector. 46 CFR 95.15-10(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 31 March 2025
Resolution: Verified during dry-docking at Vigor Shipyard and deemed acceptable by the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2023 Resolved
13199- Other (Machinery) - All marine engineering details, such as boilers, pressure vessels, main and auxiliary machinery, piping, valves, and fittings, shall be designed, constructed, and installed in accordance with the provisions of this subchapter. Vessel self-reported a hydraulic fluid leak on Port Shaft. Vessel is prohibited from operating the port propulsion system. Vessel shall submit repair proposal to our office and prior to the port system's return to service rectify the deficiency to the satisfaction of the attending Marine Inspector. If the vessel is required to move in the river system all transits within the river system shall have tug(s) assist to the satisfaction of the attending pilot. 46 CFR 50.01
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 August 2023
Resolution: Received the OEM servicing report from the attending technician for the repairs completed to the o-ring seal (replacement) at the CPP propeller flange; all sat. Completed a satisfactory pressure test of the CPP system for 48-hours; all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 31 May 2023 Resolved
When within 12 nautical miles of the nearest land, any discharge of oil or oily mixtures into the sea from a ship other than an oil tanker...is prohibited. Vessel has found an active oil leak from from shaft seal or propeller hub. Provide repair proposal and make repairs to control discharge of oil prior to movement. 33 CFR 151.10
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2023
Resolution: Replaced the port tailshaft with a spare. The source of the oil leak was determined to be a fracture in the tailshaft, which allowed hydraulic oil from the bore to leak into the stern tube.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
In the event of an accident to a boiler unfired pressure vessel, or machinery tending to render the further use of the item unsafe until repairs are made, or if by ordinary wear such items become unsafe, a report shall be made, by the chief engineer immediately to the OCMI, or if at sea immediately upon arrival at port. Vessel experienced loss of bow thruster during operations while in Port of San Francisco and did not notify OCMI. Provide report of accident from Chief Engineer to San Francisco OCMI and make repairs as required to the satisfaction of the attending Marine Inspetor during emergency drydock in Portlans, OR. 46 CFR 97.30-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2023
Resolved 6 July 2023
Resolution: Replaced the 5000 TT ZF Marine bow thruster with a spare owned by the USACE. Subsequent test of the bow thruster were satisfactory.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 March 2022 Resolved
At each inspection for certification, on all fire-extinguishing systems all controls, valves, and alarms shall be checked to ascertain the system is in operating condition. The required, provided time-delay for the Forward Void is listed as a 61 second delay; however, when tested it activated at 79 seconds. Prove proper operation of the time delay. 46 CFR 91.25-20(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2022
Resolved 2 June 2022
Resolution: Received a servicing report from A-GOW for the installation and subsequent testing of the time delay installed in Void 11. The new time delay tested satisfactorily at 68 seconds.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 15 February 2022 Resolved
The required audible alarm must sound automatically and audibly for at least 20 seconds prior to CO2 discharge into the protected space. The provided audible alarms failed to sound during the test. Prove proper operation of the audible alarms. 46 CFR 95.15-30(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2022
Resolved 10 March 2022
Resolution: Video evidence of sirens bench testing provided by AGOW rep; all sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 July 2021 Resolved
Compliance with the standards established by the American Bureau of Shipping will be considered as satisfactory evidence of the structural efficiency of the vessel. Vessel reported water ingress in #1 centerline sea water ballast tank. Vessel is required to assess & identify cause of the water ingress, submit a repair proposal, and conduct permanent repairs prior to 01AUG21 to the satisfaction of the attending marine inspector. Vessel operations is limited to a rivers route and soundings of the #1 centerline sea water ballast tank and the adjacent tanks are required every 12 hours until repairs are conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2021
Resolved 27 July 2021
Resolution: It was determined that either the vessels crew inadvertently moved water into that ballast tank or the cascade scupper valve for the #1 ballast tank malfunctioned and allowed water to enter space in adverse weather conditions.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 22 March 2021 Resolved
The scope of the annual inspection is the same as the inspection for certification as specified in §91.25-10 but in less detail unless the cognizant marine inspector finds deficiencies or determines that a major change has occurred since the last inspection. The vessel's water systems used for the storage and distribution of water, including potable water tank system was contaminated and causing illness to the ship's crew. Vessel operation is restricted to no more than 12 hours in a 24 hour period from 01Apr21 to 05Apr21. Adequate potable water must be provided while the vessel is manned. After 05Apr21, the vessel is restricted from operation until permanent repairs to the potable water system have been completed to the satisfaction of the attending marine inspector. Vessel must also provide documentation attesting that the potable water tank system has been decontaminated and is safe for human use.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 6 July 2021
Resolution: Temporary bladders have been installed inside the existing tanks, in addition to the installment of a certified ISO frame water tank on the helo deck. Permanent repairs due at next DD.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 March 2021 Resolved
Each cargo vessel must carry at least one rescue boat. The rescue boat was removed from the vessel and not available for inspection due to undergoing repairs to the engine and damaged sponson. As an alternate, your vessel may carry a motor-propelled workboat IAW 46 CFR 199.640(g). Additionally, the following restrictions are imposed: 1)The ESSAYONS is restricted to a Coastwise route; 2)the workboat shall not operate beyond the line of site of the vessel; and 3)shall carry the necessary rescue boat equipment IAW 46 CFR 199.175 table at all times. Make permanent repairs to rescue boat to satisfaction of attending Marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 16 April 2021
Resolution: Rescue boat was repaired and operationally tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 22 March 2021 Resolved
Each open lifeboat must carry a protection cover as listed in table 199.175. Equip port and starboard side lifeboats with protection cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 18 February 2022
Resolution: Vessel provided photos of installed lifeboat covers which are uploaded into documents; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 22 March 2021 Resolved
Operating instructions: Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that Illustrate the purpose of controls; Illustrate the procedures for operating the launching device; give relevant instructions or warnings; can be easily seen under emergency lighting conditions; and display symbols in accordance with IMO Resolution A.760(18). The operating instructions for launching the port and starboard side lifeboats were not posted IAW 46 CFR 199.90. Install operating instructions in the vicinity of each survival craft.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2021
Resolved 16 April 2021
Resolution: Operating instrcutions were installed near each survival craft.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2020 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by §91.45-1. Vessel to submit necessary drawings and required amplifying analysis to the Marine Safety Center (MSC) and provide resulting MSC approval correspondence to the OCMI for the replacement of the mid-body crane utilized to support dredging operations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2020
Resolved 21 May 2020
Resolution: Required documentation, the "Pedestal Crane Structural Mods" and "Pedestal Crane Installation Analysis" drawings, were submitted and reviewed by MSC on 21 MAY 2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2019 Resolved
Vessel reported that they were experiencing a one to three second lag in steering while using the STB controller with the STB steering pump. No issues noted after extensive testing on other modes. Vessel is to rectify issue within 30 days to the satisfaction of USCG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 20 February 2020
Resolution: Jastram technician attended vessel to renew potentiometers and conduct a full system calibration. Wheel console and port and starboard RFU potentiometers were renewed IAW Tech report. All calibrations and test following renewal were satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2019 Resolved
Vessel is restricted to no dredging operations until satisfactory repairs to the starboard controllable pitch propeller have been completed. 46 CFR 58.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2019
Resolved 18 June 2019
Resolution: control unit was greased and tested satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 1 May 2019 Resolved
A vessel equipped with controllable pitch propellers must have on the navigating bridge and at the engineroom control station a propeller speed and pitch position indicator. Shaft tachometers on bridge and CCS are not indicating speed. Make permanent repairs and demonstrate proper operation to the attending marine inspector. 46 CFR 113.37-5; 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2019
Resolved 9 May 2019
Resolution: Updated GSD file for PROSET was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2019 Resolved
Requirements for minimally attended machinery space: The ECC must include monitoring of all vital engineering systems, including the propulsion plant. The remote monitoring system for both propulsion engines is not operating. Make permanent repairs, provide tech report and demonstrate proper operation to attending marine inspector. Vessel must maintain full manning (manned engine room) until deficiency is cleared. 46 CFR 62.50-20(a)(3)(i); 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 9 May 2019
Resolution: Updated GSD file for PROSET was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 24 April 2019 Resolved
The proper condition and operation of the survival craft and rescue boat launching appliance at loads ranging from light load to 10% overload shall be demonstrated. Vessel replaced rescue boat davit and overhauled lifeboat davits. Conduct a lightweight, overload, and dynamic brake test for the rescue boat davit and an overload and dynamic brake test for the lifeboat davits. 46 CFR 199.45(a) & (c); 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2019
Resolved 7 May 2019
Resolution: Witnessed satisfactory port side lifeboat davit weight test and rescue boat davit weight test. OCMI approved shipyard's report and associated pictures/video of starboard lifeboat davit weight test.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 5 February 2019 Resolved
Localized pitting found in the #1 centerline double bottom ballast tank bottom plate. The two largest pit depths recorded were 1/4" in depth. Reviewed mid ship scantling, the majority of the heavy pitting is in the center 7'4" section or 5/8" plate. Calculations indicate this is 40% wastage on the bottom shell plate, however, the measurements for the total area of pitting did not indicate this is an extensive area of corrosion but more so localized. The pitting intensity was estimated to be 5% or less scattered over a 33 1/2" long by 21 1/2" wide area. Noted several lone pits throughout the tank. Submit repair plan.
Action required: 705 - Other - as specified
Due 6 March 2019
Resolved 14 March 2019
Resolution: More than a .25 inch of plate remains based on scantlings. ABS recommended clad weld repair IAW IACS procedures. Plate ground flush at clad welds and re-inspected. Repair found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 February 2019 Resolved
Vertical fracture at frame 88 port side in #3 Centerline ballast tank. Approx 1.5 inch from deck. Fracture is 2 feet in length. Crop and renew.
Action required: 705 - Other - as specified
Due 6 March 2019
Resolved 14 March 2019
Resolution: Fracture repaired by vee and weld. New coating applied to ballast tank. Repair found to be satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 August 2018 Resolved
Make permanent repairs to the vertical plate at the bottom of the hopper just above the doors in 12 Stbd Void during December 2018 drydocking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 14 March 2019
Resolution: All vertical plates for all lower hoppers cropped and renewed. NDT tested by vac box and mag particle.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 July 2018 Resolved
Structural Standards: In general, compliance with standards established by the American Bureau of Shipping will be considered as satisfactory evidence of the structural efficiency of the vessel. Temporary repairs made to the bow thruster tunnel, to secure a leak, must be made permanent by next drydock. 46 CFR 92.01-10
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2018
Resolved 14 March 2019
Resolution: Bow thruster tunnel replaced. FY19 work item 5.17.6 in Honolulu dry dock.
Engineering › Bilge Water Management System › Piping
Issued 20 June 2018 Resolved
Permanently repair bilge/ballast piping in fwd pump room that is currenlty patched with a fiberglass temporary repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 25 June 2018
Construction/Loadline › Hull › Bottom Plating
Issued 20 April 2018 Resolved
Make temporary repairs to three leaks in the #10 and #11 void. Make permanent repairs at the next scheduled dry dock in Dec. 2018.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 14 March 2019
Resolution: Vertical plates cropped and renewed for all lower hoppers at voids #10 and #11.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 March 2018 Resolved
Replace securing springs/mechanisms on 6 hatch opens on the focsle. Complete at next scheduled dry docking.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 14 March 2019
Resolution: Hatch repairs completed by PSI shipyard at Honolulu dry dock. FY19 work item 5.45.5.
Construction/Loadline › Hull › Bottom Plating
Issued 15 March 2018 Resolved
Make permanent repairs to damaged structure in #2 and #3 starboard double bottom. Complete repairs at next scheduled dry dock.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 14 March 2019
Resolution: Bottom plate and internals cropped and renewed at Honolulu dry dock. NDT shear wave, mag particle and vac box. FY19 work item 5.44.6.
Construction/Loadline › Structures › Deck Plating
Issued 15 March 2018 Resolved
Make permanent repairs to wasted plating on the main deck forward of the hopper. Complete at next scheduled dry dock.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 14 March 2019
Resolution: Main deck plating cropped and renewed by PSI shipyard in Honolulu dry dock. FY19 work item 5.44.2. See shipyard worklist in MISLE insp activity #6592409.
Construction/Loadline › Hull › Stiffener
Issued 15 March 2018 Resolved
Make permanent repairs to stanchions at frames 58 and 98. Complete at next scheduled dry dock.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 14 March 2019
Resolution: Stanchions at frames 58, 98 port, 98 stbd, and 98 centerline cropped and renewed. Lower 10 foot section at frame 68 and 88 replaced by PSI shipyard in Honolulu. FY19 work item 5.44.1.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 October 2017 Resolved
Make permanent repairs to seawater cooling piping. Until repairs are complete, vessel must operate within 3 NM of a harbor of safe refuge. 46 CFR 96.03-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 18 October 2017
Resolution: Vessel rewelded pipe. Attending Marine Inspector witnessed satisfactory NDT (Dye Pen).
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 8 September 2017 Resolved
Repair leak in starboard side CPP system prior to conducting dredging operations.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 26 September 2017
Resolution: Witnessed operational test of starboard side CPP.
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2017 Resolved
Make permanent repairs to all items identified on attached letter, dated 08 MAY 2017, at the next scheduled dry dock availability. 46 CFR 92.01-10
Due 31 December 2017
Resolved 15 March 2018
Construction/Loadline › Hull › Bracket
Issued 6 May 2017 Resolved
Temporary repairs for the #10 Hopper fracture, as proposed, will be accepted until permanent repairs can be made at the next scheduled drydock to the satisfaction of an attending Coast Guard Marine Inspector.
Due 1 November 2017
Resolved 15 March 2018
Resolution: Renewed plating in vicinity, air tested sat.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 May 2017 Resolved
Inoperable X-Band radar, vessel is restricted to 2 miles visibility until corrected.
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 5 May 2017
Construction/Loadline › Hull › Bracket
Issued 3 May 2017 Resolved
Fracture in No. 10 Hopper Void, submit repair proposal within 03 business days to MSU Portland for local review. 46 CFR 92.01-10
Action required: 705 - Other - as specified
Due 6 May 2017
Resolved 6 May 2017
Resolution: Repair proposal available in vessel file. Will repair at next drydocking.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 April 2017 Resolved
The employer needs a sufficient number of alcohol testing devices or must remain within 2 hours of obtaining testing. 46 CFR 4.06-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 6 May 2017
Resolution: Purchased alcohol test strips.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 12 April 2017 Resolved
Replace kick-out panel for pressure relief and remove CO2 system as it is not required in the space. 46 CFR 95.15-40(a)
Condition: Improper/Lack of Maintenance
Due 12 May 2017
Resolved 6 May 2017
Resolution: Kick out panel has been replaced and is operational. O/O will install either manual pull or install time delay with alarm in space at next drydocking, scheduled in December 2017.
Engineering › Steering Gear System › Piping
Issued 31 March 2017 Resolved
Make appropriate repairs to steering gear system so that there are no hyraulic oil leaks. Vessel must use sufficient tugs of adequate horsepower to maintain positive control of the vessel in all anticipated river conditions for all vessel movements. 46 CFR 58.25-20
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 12 April 2017
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 31 March 2017 Resolved
PROVIDE RUDDER ANGLE INDICATOR IN AFT STEERING. 46 CFR 58.25-25
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Engineering › Steering Gear System › Valve
Issued 31 March 2017 Resolved
PROVIDE INSTRUCTIONS FOR CHANGING TO EMERGENCY STEERING INCLUDING LABELING OF EACH CLUTCH, GEAR, WHEEL, LEVER,VALVE OR SWITCH USED DURING THE CHANGEOVER. 46 CFR 97.37-33
Due 1 May 2017
Resolved 12 April 2017
Engineering › Steering Gear System › Solenoid Valve
Issued 31 March 2017 Resolved
PROVIDE APPROVAL LETTER FROM MSC FOR LATEST REVISION OF THE DESIGN VERIFICATION TESTING PROCEDURES AND PERIODIC SAFETY TESTING PROCEDURES. 46 CFR 61.40
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 26 April 2017
Resolution: Received approved DVTPS.
Engineering › Steering Gear System › Solenoid Valve
Issued 29 March 2017 Resolved
Complete design verification testing of newly installed steering system, per the approved procedures, with no alarms or faults. Vessel must use sufficient tugs of adequate horsepower to maintain positive control of the vessel in all anticipated river conditions, for all vessel movements. To satisfaction of attending MI. 46 CFR 61.40
Action required: 705 - Other - as specified
Due 29 March 2017
Resolved 31 March 2017
Resolution: Completed satisfactory design verification testing procedures.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 May 2016 Resolved
Provide documentation verifying the proper operation of the vessel's 3 CM (X-Band) radar to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 9 May 2016
Resolution: Verified operation and recieved documentation from tech rep attesting to repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 December 2015 Resolved
Vessel shall make permanent repairs to lower bulkhead between 11 and 12 centerline voids where temporary repairs were authorized 2/28/2016 at next drydocking.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 March 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 August 2015 Resolved
SG02 Install an odorizing unit to produce the scent of wintergreen to the existing CO2 system as per 46 CFR 95.15-60. The CO2 system E/R time delay was altered, see narrative.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 11 February 2016
Resolution: Vessel installed new pilot bottles, odorizers, and manifold shut-off valves in accordance with 46 CFR 108.444 and 46 CFR 108.446
Fire Fighting › Fire Hydrants › Material
Issued 5 August 2015 Resolved
SG01 Replace all plastic handles and plastic ball valves on y-gate fire hose stations with brass, bronze or equivalent metal.
Due 5 November 2015
Resolved 11 February 2016
Resolution: Verified that all y gates have been replaced with units having metallic corrosion resistant valves
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 5 August 2015 Resolved
CONDUCT PERMANENT REPAIRS TO THE PORT AND STBD CPP HUBS WHERE TEMPORARY OR EMERGENCY REPAIRS HAVE BEEN MADE IN THE PAST. REPAIRS TO THE CPP HUBS SHALL BE MADE IN ACCORDANCE WITH OEM SPECIFICATIONS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR AND TECHNICAL REPRESENTATIVE. 46 CFR 91.45
Due 5 November 2015
Resolved 16 February 2016
Resolution: propellor shaft and hubs have been machined and proven to be leak free
Construction/Loadline › Structures › Superstructure
Issued 5 August 2015 Resolved
CROP AND RENEW THE POOP DECK IN THE VICINITY OF BULKHEAD 108 WHERE TEMPORARY REPAIRS HAVE BEEN AUTHORIZED OR WHERE STEEL WAISTAGE LIMITS EXCEED MAXIMUM TOLERANCES AS DEFINED IN NVIC 7-68 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Due 5 November 2015
Resolved 16 February 2016
Resolution: Areas noted have been cropped and renewed to satisfaction of attending inspector.
Construction/Loadline › Hull › Hull Plating
Issued 18 June 2015 Resolved
PROVIDE A REPAIR PROPOSAL FOR THE WASTED AREAS OF STEEL IN THE VESSELS HOPPER SPACES IDENTIFIED IN THE GUAGING REPORT SUBMITTED TO THE USCG ON 16JUN2015 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CONDUCTING DREDGING OPERATIONS. 46 CFR 91.45
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 July 2015
Resolved 29 July 2015
Resolution: All repairs complete and tested satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 11 June 2015 Resolved
CONDUCT REPAIRS TO THE UPPERDECK BETWEEN FRAMES 108 TO 125 IN ACCORDANCE WITH THE VESSELS REPAIR PROPOSAL THAT WAS SUBMITTED ON 4JUN15 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CONDUCTING DREDGING OPERATIONS. 46 CFR 91.45
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2015
Resolved 3 August 2015
Resolution: Verified repairs complete and A-60 insulation properly installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 June 2015 Resolved
CONDUCT REPAIRS TO BULKHEAD 108 IN ACCORDANCE WITH THE VESSELS REPAIR PROPOSAL THAT WAS SUBMITTED ON 5JUN15 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CONDUCTION DREDGING OPERATIONS. 46 CFR 91.45
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2015
Resolved 29 July 2015
Resolution: All repairs have been completed and tested satisfactory.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 11 June 2015 Resolved
CONDUCT PERMANENT REPAIRS TO THE PORT AND STBD CPP SYSTEMS ENSURING THAT THE SYSTEMS ARE FULLY FUNCTIONAL IN ACCORDANCE WITH OEM SPECIFICATIONS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CONDUCTING DREDGING OPERATIONS. 46 CFR 91.45
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2015
Resolved 20 July 2015
Resolution: RECEIVED A TECH REPORT FROM PROPULSION SYSTEMS INCORPORTATED DATED 16JUL2015 STATING THAT THE TEMPORARY REPAIRS TO PORT AND STBD CPP SYSTEMS ARE IN NO WAY DETRIMENTAL TO THE NORMAL FUNCTIONAL OPERATION OF THE CPP SYSTEM ABOARD THE VESSEL.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 11 June 2015 Resolved
REPAIR THE PORT AND STBD CPP HUB OIL LEAKS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE VESSEL FEFLOATING FROM DRY-DOCK.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 July 2015
Resolved 14 June 2015
Resolution: Conducted a visual examination of the port and stbd cpp hubs to ensure the temporary repairs had stopped the hubs from leaking oil, all sat.
Stability › Unintentional Flooding › General
Issued 5 July 2011 Resolved
Make the #6 stbd void immdeiately available for internal exam (pumped down completely and gas freed with marine chemist certificate) for the purpose of examining the reported fracture.
Due 12 July 2011
Resolved 12 July 2011
Resolution: Internal exam did not provide any clues to the cause of the flooding. No fractures, broken piping, or any other causes could be determined.
Stability › Unintentional Flooding › General
Issued 5 July 2011 Resolved
Actively monitor #6s void for signs of water intrusion during the vessel's next cycle. Provide report to the local CG office and the completion of the cycle.
Due 20 July 2011
Resolved 18 July 2011
Resolution: Received soundings report for the request time frame. No additional water intrusion was noted.
Stability › Unintentional Flooding › General
Issued 5 July 2011 Resolved
Determine cause of reported water intrusion prior to leaving the San Francisco AOR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2011
Resolution: Stuck ball check valve determined to be the most likely cause of the water intrusion. Valve replaced in kind.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 20 February 2009 Resolved
Renew watertight door gasket for Weld Shop and adjust as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2009
Resolved 23 February 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 20 February 2009 Resolved
Make repairs or renew 90 degree exhaust duct for the #2 U-Void.
Action required: 705 - Other - as specified
Due 20 March 2009
Resolved 24 March 2009
Resolution: 90 degree exhaust ducting renewed.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 February 2009 Resolved
Make appropriate changes to the Fire Control Plan and submit to the local OCMI for review and approval.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 18 March 2010
Fire Fighting › Fire Main › Condition
Issued 20 February 2009 Resolved
Prep, prime, and paint fire main station riser in #10 Port Hopper Void.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2009
Resolved 28 July 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 20 February 2009 Resolved
Renew both stern tube bulkhead seals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 16 February 2010
Resolution: Both stern tube seal have been renewed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 April 2007 Resolved
Make door to incinerator room self-closing.
Due 10 May 2007
Resolved 11 September 2007
Resolution: Self-closing device attached.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 10 April 2007 Resolved
Make necessary changes "in kind' to repair hydraulic leak on rescue boat davit.
Due 31 July 2007
Resolved 11 September 2007
Resolution: Compete
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 24 January 2007 Resolved
Make necessary changes to the CO2 system to comply with the manufacture's instructions and 46 CFR 95.15 to the satisfaction of the attending CG marine inspector and no later than 01 JAN 2008.
Due 1 January 2008
Resolved 1 February 2008
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 9 March 2006 Resolved
Provide copies of new crane certification documents. 46 CFR 91.25-25(a) (3) & (b)
Condition: Unknown
Due 9 April 2006
Resolved 11 May 2006
Resolution: Wire rope and crane testing and inspection certificates received.
Construction/Loadline › Hull › Hull Plating
Issued 1 August 2005 Resolved
Make permanent repairs to plate fracture in hopper at slope sheet, #12 port void, frame 98 where temp. weld repair was completed.
Due 1 December 2005
Resolved 3 January 2006
Construction/Loadline › Hull › Weld
Issued 1 August 2005 Resolved
Evaluate temp weld repair to plate fracture in hopper, frame 48 separating hopper from lower pump room.
Due 1 December 2005
Resolved 3 January 2006
Electrical › Electric Generation Source (service) › Generator
Issued 21 June 2005 Resolved
Prove proper operation of the stbd SSDG to the satisfaction of the attending CG marine inspector. Until this requirement is corrected, the vessel's operation is limited to conducting dredging operations within the vicinity of the Columbia River and the designated area for disposal of spoils.
Condition: Unknown
Due 21 August 2005
Resolved 5 August 2005
Resolution: Proper operation proven satisfactorily.
Engineering › Steering Gear System › Rudder
Issued 4 April 2005 Resolved
Conduct under water survey of both rudders, propellers and hull mid ship aft. Diver report to be submitted to attending Marine Inspector prior to departing port.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 5 April 2005
Resolution: Dive survey conducted rudders showed indication of being forced up during grounding and making contact with blocked attached to hull. No additional damage noted.
Engineering › Steering Gear System › Rudder Stock
Issued 4 April 2005 Resolved
At STBD post packing gland forward there is excessive leaking. Remove RTV and make permanant repairs. Leaking noted only at fully loaded condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2005
Resolved 5 August 2005
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 4 April 2005 Resolved
Provide copy of drug testing results to the attending marine inspector for 2 members of bridge crew.
Action required: 705 - Other - as specified
Due 8 May 2005
Resolved 5 August 2005
Documentation › Certificates/Documents
Issued 2 March 2004 Resolved
Provide Safety Radiotelephony Certificate & FCC Station license.
Due 2 March 2004
Resolved 2 March 2004
Resolution: Vsl not req''d as Public Vsl
Electrical › Electrical Distribution System (service) › Panelboard
Issued 2 March 2004 Resolved
Install blank where missing on 120V panel 01-152-2 on mess deck.
Due 2 March 2004
Resolved 2 March 2004
Fire Fighting › Means of Escape › Doorways
Issued 2 March 2004 Resolved
Install kickout panel or replace the incinerator room door so it opens out into cooridor to comply with requirements for Fixed Fire Extinguishing Systems installed within a compartment. LEGACY COMPONENT DESC: Doorways
Due 30 April 2004
Resolved 6 May 2004
Resolution: Cleared by PORMS per phone call w/ Hanko Sullivan (Act #1996036)
Accommodation/Occupational Safety
Issued 2 March 2004 Resolved
Restow flammables from 01-152-1-A util closet to the paint locker.
Due 2 March 2004
Resolved 2 March 2004
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 2 March 2004 Resolved
Demonstrate proper operation of fathometer.
Due 2 March 2004
Resolved 2 March 2004
Construction/Loadline › Structures › Door
Issued 2 March 2004 Resolved
Free up the position indicator microswitch for #3 WTD.
Due 2 March 2004
Resolved 2 March 2004
Documentation › Certificates/Documents
Issued 21 January 2004 Resolved
Provide safety radiotelephony certificate and FCC station license.
Due 21 February 2004
Resolved 2 March 2004
Resolution: Cleared by HONMS on this date (Activity #2016526)
Electrical
Issued 21 January 2004 Resolved
Install blank where missing on 120V panel on vessel mess deck.
Due 21 February 2004
Resolved 2 March 2004
Resolution: Cleared by HONMS on this date (Activity #2016526)
Fire Fighting › Means of Escape
Issued 21 January 2004 Resolved
Install kickout panel on incinerator door or replace the incinerator door so that it opens out into the passageway. LEGACY COMPONENT DESC: Doorways
Due 21 February 2004
Resolved 5 May 2004
Resolution: Kickout panel installed on incinerator door.
Fire Fighting › Combustible Materials
Issued 21 January 2004 Resolved
Restow flammables from 01-152-1-A to the paint locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Due 21 February 2004
Resolved 2 March 2004
Resolution: Cleared by HONMS on this date (Activity #2016526)
Operations/Management › Navigation Safety
Issued 21 January 2004 Resolved
Demonstrate proper operation of vessel fathometer.
Due 21 February 2004
Resolved 2 March 2004
Resolution: Cleared by HONMS on this date (Activity #2016526)
Construction/Loadline › Hull
Issued 21 January 2004 Resolved
Free up the open micro switch for the #3 watertight door.
Due 21 February 2004
Resolved 2 March 2004
Resolution: Cleared by HONMS on this date (Activity #2016526)
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 25 March 2003 Resolved
Renew and demonstrate operation of time delay for Bos'n Stores fixed CO2 system. This item must be completed prior to sailing. LEGACY COMPONENT DESC: Operating Controls
Due 4 April 2003
Resolved 25 March 2003
Electrical › Lighting (service)
Issued 25 March 2003 Resolved
Provide guard for light in paint locker. This item must be completed prior to sailing. LEGACY COMPONENT DESC: Lighting Fixture
Due 27 March 2003
Resolved 27 March 2003
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 25 March 2003 Resolved
Hydro-test all composite SCBA bottles that are over three years from their last hydro. This item must be completed prior to sailing.
Due 27 March 2003
Resolved 27 March 2003
Engineering › Generator (propulsion-electric)
Issued 10 May 2002 Resolved
Demonstrate proper operation of the ship's port service generator to include full load, alarms and shutdowns to the satisfaction of an attending marine inspector.
Due 24 May 2002
Resolved 7 June 2002
Engineering
Issued 21 February 2002 Resolved
Calibrate main steam preasure gauge in accordance with 46 CFR 61.05-10. LEGACY COMPONENT DESC: Main Steam Gauge Calibration
Condition: Improper/Lack of Maintenance
Due 4 May 2002
Resolved 10 May 2002
Electrical
Issued 21 February 2002 Resolved
Demonstrate the proper operation of the EOT to the satisfaction of the attending Coast Guard marine inspector. Starboard EOT unable to answer ahead bell. LEGACY COMPONENT DESC: EOT
Condition: Unknown
Due 4 May 2002
Resolved 10 May 2002
Communications › Alarms/Indicators
Issued 21 February 2002 Resolved
Indicator lights for water tight doors on bridge are reversed. LEGACY COMPONENT DESC: Water Tight Doors
Condition: Improper Installation
Due 21 March 2002
Resolved 22 March 2002
Lifesaving › Launching Appliances
Issued 21 February 2002 Resolved
Adjust brake on port life boat winch so that lever brake operates properly when release. (lever brake hits deck when released.) LEGACY COMPONENT DESC: Winch Brake
Condition: Unknown
Due 4 May 2002
Resolved 10 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 February 2002 Resolved
Install operation switches on WTD's #3 and #4 in accordance with ASTM standards. Persons passing through door should be able to hold door open by activating switches on both sides of door simultaneously. LEGACY COMPONENT DESC: Watertight Doors
Condition: Improper Installation
Due 31 December 2002
Resolved 12 November 2002
Lifesaving › Lifeboat
Issued 21 February 2002 Resolved
Fit all life boats and rescue boats with retro-reflective tape in accordance with 46 CFR 199.176 (IMO Res. A.658(16)). Retro-reflective tape needs to be fitted on the bottom of all life boats that are none self-righting. LEGACY COMPONENT DESC: Markings
Condition: Improper Installation
Due 4 May 2002
Resolved 7 June 2002
Engineering
Issued 7 February 2001 Resolved
Repair or replace leaking boiler fuel pressure switch diaphram. 46 CFR 63.15-1
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Fire Fighting
Issued 7 February 2001 Resolved
Update shipboard fire response plan and vessel fire control plan to reflectventilation closures. 46 CFR 91.55-5(d)
Condition: Unknown
Due 7 February 2001
Resolved 7 February 2001
Electrical
Issued 7 February 2001 Resolved
Provide proof that both over-side motor starter switchboard (2,300 volts) meet NEMA 250 Type 2 or IEC IP 22 degree of protection/or install approved drip-shields on switchboard tops. 46 CFR 111.01-9
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Fire Fighting
Issued 7 February 2001 Resolved
Provide dampers or covers for all machinery space supply and exhaust ventilation systems opening to the atmosphere. 46 CFR92.15-10 and 46 CFR 95.15-35(c).
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Lifesaving
Issued 7 February 2001 Resolved
Mark Port and Stbd lifeboats in accordance with 46 CFR 199.176
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Engineering
Issued 21 March 2000 Resolved
Demonstrate low lube oil trip on stbd generator.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Engineering
Issued 21 March 2000 Resolved
Renew vent louvers in the emergency generator room nlt 21JUN00
Condition: Unknown
Due 21 June 2000
Resolved 10 April 2000
Engineering
Issued 21 March 2000 Resolved
Demonstrate reverse power relay on stbd generator.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Engineering
Issued 21 March 2000 Resolved
Demonstrate overspeed trip on stbd generator.
Condition: Unknown
Due 27 March 2000
Resolved 27 March 2000
Lifesaving
Issued 14 January 1999 Resolved
Make proper repairs to fiberglass on keel of port and starboard lifeboats. Damaged areas include keel in way of gripe weardown plates on both boats and on the gunwale of the starboard boat. Remove gripe weardown plates on both boats for inspection after repairs are complete.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Engineering
Issued 14 January 1999 Resolved
Prior to use of deck steam pressure washer bring into compliance with 46 CFR 50, 52, 61, 63 and ASME CSD-1a or remove unit in its entirety.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Fire Fighting
Issued 14 January 1999 Resolved
Provide written instructions to crew and post that state the hatches between decks in the bosun's stores (weld shop), the bow thruster motor room, and the bow thruster room shall remain closed when the spaces are notmanned. If hatches are open, the CO2 system will not be effective.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Engineering
Issued 14 January 1999 Resolved
Provide audible alarm for forward oily water separator that sounds in manned location or remove all capability for automatic operation and provide written procedure that required unit to be manned during operation.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Fire Fighting
Issued 14 January 1999 Resolved
Provide fixed CO2 system for paint locker through-out machinery space or remove all flammables from lockers.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Electrical
Issued 14 January 1999 Resolved
Replace all ground fault interupter receptacles in machinery space with watertight receptacles. Provide approved plans for any other ground fault receptacles installed in other locations.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Lifesaving
Issued 7 July 1998 Resolved
MAKE REPAIRS TO LOWER AFT DAVIT ARM BRACKET ON PORT SIDE, WHERE WELD WAS PREVIOUSLY MISSED. BRACKET IS STARTING TO PULL AWAY FROM DECK, BOTH AFT ANDFWD CORNERS.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Construction/Loadline
Issued 7 July 1998 Resolved
MAKE PERMANENT REPAIRS TO VENTS FOR NUMBER 4 AND 5 DOUBLE BOTTOMS STARBOARDSIDE. TEMP REPAIRS HAVE BEEN AFFECTED.
Condition: Unknown
Due 7 July 1998
Resolved 7 July 1998
Lifesaving
Issued 9 March 1998 Resolved
INSTALL GENERAL ALARM BEACON IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 9 March 1998 Resolved
REPAIR WATERTIGHT DOOR NUMBER 5, MICROSWITCH FOR OPENING HAS HISTORY OF STICKING PREVENTING DOOR FROM OPENING.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Electrical
Issued 9 March 1998 Resolved
INSTALL BLOCKING AROUND GENERAL ALARM BATTERIES TO PREVENT MOVEMENT. CLEAN TERMINALS ON CENTER BANK OF BATTERIES.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 9 March 1998 Resolved
INSTALL EMERGENCY LIGHTS IN TECH LIBRARY.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 9 March 1998 Resolved
PROPERLY HARDWIRE OR INSTALL CORRECT WATERTIGHT RECEPTACLES AND PLUGS ON WASHERS AND DRYERS.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Fire Fighting
Issued 23 February 1998 Resolved
PRIOR TO VESSEL ATTEMPTING DOCK TRIALS, DEMONSTRATE PROPER OPERATION OF ALLCO2 60 SECOND TIME DELAYS, EXCEPT ENGINEROOM, TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Fire Fighting
Issued 23 February 1998 Resolved
DEMONSTRATE PROPER CLOSURE OF ALL AIR LOUVERS, LOCATED IN THE EMERGENCY GENERATOR ROOM, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Documentation
Issued 26 February 1997 Resolved
PROVIDE PROOF OF CREW PARTICIPATION IN VALID DRUG TESTING PROGRAM.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Electrical
Issued 26 February 1997 Resolved
PROVE OPERATION IN ACCORDANCE WITH AUTOMATION TEST PROCEDURES OR SUBMIT PROCEDURE REVISIONS FOR THE GENERATOR AUTOMATION CONTROL MODE FOR CCS DURING SERVICE GENERATOR TESTING (AUTOMATION PROCEDURE ITEM 9.A).
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Engineering
Issued 26 February 1997 Resolved
PROVE OPERATION IN ACCORDANCE WITH AUTOMATION TEST PROCEDURES OR SUBMIT TEST PROCEDURE REVISIONS FOR THE LOW VOLTAGE TEST METHOD FOR THE FUEL VALVECLOSURE ON THE LOW PRESSURE HEATING BOILER (AUTOMATION PROCEDURE ITEM 11.B.6).
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Navigation
Issued 26 February 1997 Resolved
PROVE OPERATION IN ACCORDANCE WITH AUTOMATION TEST PROCEDURES OR SUBMIT TEST PROCEDURE REVISIONS FOR THE "POWER SUPPLY BROKEN" ALARM TEST FOR THE STEERING GEAR CONTROLLERS (AUTOMATION PROCEDURE ITEM 14.D).
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Accommodation/Occupational Safety
Issued 26 February 1997 Resolved
PROVE PROPER OPERATION OF AUDIBLE ENGINEER ASSISTANCE NEEDED ALARM ON THE FOLLOWING MONITOR PANELS: ASSIST [name withheld], COMPUTER ROOM, AND PUMP ROOM.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Electrical
Issued 26 February 1997 Resolved
REMOVE DEAD END CABLES (2) IN OVERHEAD CABLE RUN JUST AFT OF STARBOARD REDUCTION GEAR.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Engineering
Issued 26 February 1997 Resolved
PROVE OPERATION IN ACCORDANCE WITH AUTOMATION TEST PROCEDURES OR SUBMIT TEST PROCEDURE REVISION FOR THE AUDIBLE AND VISUAL ALARM FOR FAILURE TO ACKNOWLEDGE PROPULSION TRANSFER (AUTOMATION PROCEDURE ITEM 7.E).
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Electrical
Issued 26 February 1997 Resolved
REMOVE DEAD END WIRE FROM BENEATH STARBOARD BRIDGE CRAWL SPACE.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Construction/Loadline
Issued 28 June 1996 Resolved
MAKE INSERT IN BULKHEAD FR 48 BETWEEN HOPPER & PUMPROOM, AROUND TUNNEL. UT(GAUGE) PLATE SURROUNDING TUNNEL. CROP & INSERT AS REQUIRED BACK TO GOOD METAL. THESE REPAIRS SHALL BE APPROVED & WITNESSED BY THE ATTENDING MARINEINSPECTOR PRIOR TO OR AT NEXT DRYDOCK BUT NO LATER THAN 31DEC97.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Engineering
Issued 4 March 1996 Resolved
PROVIDE REVISED APPROVED PROPULSION CONTROL AUTOMATION TEST PROCEDURES.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Engineering
Issued 4 March 1996 Resolved
PROVE PROPER OPERATION OF OVERSPEED DEVICE ON STARBOARD DREDGE ENGINE.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Unknown
Issued 4 March 1996 Resolved
PROVIDE COPY OF WASTE MANAGEMENT PLAN IAW 33CFR151.57.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Fire Fighting
Issued 4 March 1996 Resolved
SERVICE OR REMOVE SEMI-PORTABLE FIRE FIGHTING EQUIPMENT FOR HELO DECK.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 4 March 1996 Resolved
EITHER INSTALL A RELIEF VALVE FOR EACH FIRE PUMP IN ACCORDANCE WITH 46CFR108.417 OR DEMONSTRATE THE 2 PUMPS CANNOT DEVELOP THE PRESSURE DESCRIBED IN 46CFR108.415 PLUS 25 PSI.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Engineering
Issued 9 March 1995 Resolved
DEMONSTRATE EMERGENCY SHUTDOWNS ON PORT MAIN ENGINE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Construction/Loadline
Issued 9 March 1995 Resolved
DEMONSTRATE CONTROL/OPERATION OF EMERGENCY BILE SYSTEM.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 9 March 1995 Resolved
PROVIDE 100 PSI RELIEF VALVE FOR CONTROL AIR TANK IN MACHINERY SPACE.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Lifesaving
Issued 9 March 1995 Resolved
HOOK UP AUDIO ALARMS ON WATCH CALL SYSTEM IN C/E OFFICE AND GYM.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Engineering
Issued 25 August 1994 Resolved
Make proposal for permanent repairs to CPU unit. (Retaining pin, replacing link attached to clevis)_x001C_ _x001C_
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Unknown
Issued 25 August 1994 Resolved
Provide copy of CG-2692, Marine Casualty Report outlining grounding, damageand repairs.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Unknown
Issued 25 August 1994 Resolved
Proceed to Portland shipyard for damage survey and effect repairs.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Fire Fighting
Issued 23 February 1994 Resolved
PROVE PROPER OPERATION OF FWD FIRE PUMP. THIS ITEM SHALL BE COMPLETED PRIOR TO THE VESSEL GETTING UNDERWAY OR BY THE COMPLIANCE DATE, WHICH EVER OCCURS FIRST.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Construction/Loadline
Issued 29 December 1993 Resolved
MAKE PERMANENT REPAIRS TO SIDESHELL AND INTERNAL STIFFENER AT FRAME 68 STARBOARD WHERE INSET IN WAY OF DOUBLER PLATE.
Condition: Unknown
Due 29 December 1993
Resolved 29 December 1993
Construction/Loadline
Issued 16 September 1993 Resolved
MAKE PERCENT REPAIR TO THE DAMAGE TO THE HULL IN WAY OF VOID NO. 5.
Condition: Unknown
Due 16 September 1993
Resolved 16 September 1993
Electrical
Issued 10 February 1992 Resolved
REPAIR AND PROVE OPERATION OF THE LOWER VENT LOUVERS IN THE EMERGENCY DIESEL GENERATOR SPACE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Electrical
Issued 10 February 1992 Resolved
PROVE PROPER STAND-BY OPERATION OF SSDG'S AS PER TEST ITEM #5 IN THE AUTOMATION TEST PROCEDURE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Engineering
Issued 10 February 1992 Resolved
REPAIR PORT SHAFT RPM SENDING UNIT.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Navigation
Issued 10 February 1992 Resolved
SUBMIT PORT STEERING MOTOR WIRING SPEC'S TO MSC AS PER MSC LETTER DATED 28 JUNE 1991, FOR APPROVAL.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Electrical
Issued 28 May 1991 Resolved
REPAIR OR REPLACE REVERSE POWER RELAY ON THE STARBOARD GENERATOR AND_x001C_ PROVE THE PROPER OPERATION WITH A MARINE INSPECTOR PRESENT. GENERATOR_x001C_ SHALL NOT BE USED UNTIL THE REQUIREMENT IS CORRECTED.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Unknown
Issued 26 March 1991 Resolved
REPLACE HYDRAULIC TANK IN THE ELECTRICIAN SHOP AND INSTALL PROPER VENT. IN-STALL PROPER VENT ON HYDRAULIC TANK IN INCINERATOR ROOM TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 26 March 1991 Resolved
REWRITE AND SUBMIT AUTOMATION PROCEDURES WITH APPROPRIATE CHANGES AND UP- DATES AS TO OPERATION OF VESSEL.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Lifesaving
Issued 26 March 1991 Resolved
REMOVE OR REPAIR RESCUE BOAT DAVITS AND PROPERLY INSTALL BOAT CRADLE. TO BEDONE PRIOR TO USE OF RESCUE BOAT AND NO LATER THAN 26APR91 TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Electrical
Issued 26 March 1991 Resolved
REPAIR OR REPLACE REVERSE POWER RELAY FOR STBD GENERATOR AND PROVE PROPER OPERATION TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 26 March 1991 Resolved
SUBMIT PRINTS FOR APPROVAL OF ALL NEW SYSTEMS INSTALLED DURING THIS REPAIR PERIOD.(AIR SYSTEM, NEW REEFER & WALK-IN FREEZER AND CHANGES TO STEERING SHOWING INSTALLATION TO EMER. BOARD)
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Electrical
Issued 18 January 1990 Resolved
OBTAIN APPROVED PLANS & INSTALL A CIRCUIT FROM THE EMERGENCY POWER DISTRIBUTION PANAL TO SUPPLY EMERGENCY POWER TO ONE OF THE STEERING SYSTEMS& SFRVO PUMPS FOR THE CPP & CLUTCH FOR THE MAIN ENGINES. PLANS & SPEC. ARETO BE SUBMITTED TO USCG MSC FOR APPROVAL PRIOR TO 01APR90. (CONT.)
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Electrical
Issued 18 January 1990 Resolved
(CONT) INSTALLATION & TESTING SHOULD BE COMPLETED TO THE SATISFACTION OF A C.G. INSPECTOR PRIOR TO 18JAN91.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Engineering
Issued 18 January 1990 Resolved
REPAIR OR REPLACE RELIEF VALVE FOR #2 WASTE HEAT BOILER, SET RELIEF, LOG RESULTS & SUBMIT COPY TO [name withheld] PRIOR TO 07FEB90.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Electrical
Issued 16 February 1989 Resolved
PROVE PROPER OPERATION OF THE THREE (3) SHIPS SERVICE GENERATORS REVERSE POWER RELAYS.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Electrical
Issued 3 March 1988 Resolved
SUBMIT PLANS FOR AFT PORTION OF WELDING PWER DISTRIBUTION SYSTEM TO USCG MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 4 March 1987 Resolved
MAKE GENERAL ALARM FLASHING LIGHT IN LOWER PUMP ROOM OPERATE PROPERLY.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Fire Fighting
Issued 4 March 1987 Resolved
PROVIDE EVIDENCE OF HYDROSTATIC TESTING OF ALL PORTABLE FIRE EXTINGUISHERS WITHIN LAST FIVE YEARS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Engineering
Issued 30 January 1987 Resolved
MAKE AVAILABLE FOR INSPECTION THE FIRE SIDES AND WATER SIDES OF THE (3) THREE MAXIMUM EXHAUST GAS BOILERS IN ACCORDANCE WITH 46 CFR 61.05.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Fire Fighting
Issued 30 January 1987 Resolved
CHANGE FIRE DETECTOR INDICATORS ON ALL DETECTION PANELS FROM HEAT EXCHANGER ROOM TO PUMP ROOM.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Documentation
Issued 30 January 1987 Resolved
POST CURRENT STABILITY LETTER IN ACCORDANCE WITH 46 CFR 97.11.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Engineering
Issued 30 January 1987 Resolved
APPLY HYDROSTATIC TESTS TO THE (3) THREE MAXIMUM EXHAUST GAS BOILERS IN ACCORDANCE WITH 46 CFR 61.05-10.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Navigation
Issued 30 January 1987 Resolved
MAKE THE STARBOARD ENGINE ORDER TELEGRAPH OPERATE PROPERLY IN ACCORDANCE WITH 46 CFR 113.35.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Navigation
Issued 30 January 1987 Resolved
MAKE THE WRONG DIRECTION ALARMS FOR BOTH MAIN ENGINES OPERATE PROPERLY.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Unknown
Issued 30 January 1987 Resolved
DEMONSTRATE PROPER OPERATION OF THE OILY-WATER SEPARATOR/MONITERING SYSTEM FOR MACHINERY SPACE BILGES.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Construction/Loadline
Issued 22 December 1986 Resolved
PROVIDE TO [name withheld] AND APPROVED BILL OF MATERIALS ON THE NEWLY INSTALLED WATERTIGHT DOOR.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986
Engineering
Issued 22 December 1986 Resolved
PROVIDE TO [name withheld] A REPORT OF ORIGINAL CLEARANCE READINGS ON THE PORT AND STBD STERN TUBE AND STRUT BEARINGS.
Condition: Unknown
Due 22 December 1986
Resolved 22 December 1986
Electrical
Issued 16 December 1985 Resolved
SUBMIT FOR USCG APPROVAL, PLANS FOR WELDING CONNECTORS' SYSTEM AS PER 46 CFR 110.25-1.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Fire Fighting
Issued 16 December 1985 Resolved
PROVIDE AUTOMATIC CLOSURES FOR THE GALLEY STORE HOOD THAT CAN BE CLOSED ON ACTIVATION OF THE GALLEY CO2 SYSTEM AS PER 46 CFR 95.15-35(A).
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985 Resolved
SECURE CABLE FOR WELDING CONNECTORS' SYSTEM WITH METAL RETAINING DEVICES ONVERTICAL RUNS AS PER IEEE-45-20.5 AND 46 CFR 111.60-5.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Deck/Cargo
Issued 16 December 1985 Resolved
PROVIDE WORKABLE CLOSURES FOR TWO (2) FUEL TANK VENTS ON THE STARBOARD MAINDECK AS PER 46 CFR 56.50-85.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Electrical
Issued 16 December 1985 Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELL(S) TO MAKE THE GENERAL ALARM AUDIBLE FOR THE ELECTRICIAN'S SHOP AS PER 46 CFR 113.25-9(A).
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Fire Fighting
Issued 16 December 1985 Resolved
PROVIDE FOR SERVICING OF ALL PORTABLE AND FIXED FIRE EXTINGUISHING EQUIP- MENT AS PER 46 CFR 91.25-20.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Documentation
Issued 19 February 1985 Resolved
PREPARE FIRE CONTROL PLAN AND POST ONE COPY IN DECKHOUSE AND ONE OUTSIDE DECKHOUSE.
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985
Fire Fighting
Issued 19 February 1985 Resolved
MAKE PERMANENT ELECTRICAL CONNECTION SO GALLEY VENTILATION SUPPLY BLOWER AUTOMATICALLY SHUTS OFF WHEN CO2 IS RELEASED.
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985

Casualty record · 12

3 April 2005Routine · role: Involved in a Marine Casualty · activity 2456068
4 March 2010Routine · role: Involved in a Marine Casualty · activity 3730201
16 August 2010Routine · role: Involved in a Marine Casualty · activity 3855082
3 July 2011Routine · role: Involved in a Marine Casualty · activity 4088682
5 July 2011Routine · role: Involved in a Marine Casualty · activity 4088720
5 June 2012Routine · role: Involved in a Marine Casualty · activity 4343776
26 August 2012Routine · role: Involved in a Marine Casualty · activity 4437688
17 August 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4690344
10 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6129762
1 November 2022Routine · role: Involved in a Marine Casualty · activity 7590586
26 July 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7764384
21 June 2026Routine · role: Involved in a Marine Casualty · activity 8416533
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.