Records from 2016 to 2026. Most recent: inspection, 8 January 2026.
Inspection history · 33
8 January 2026
Vessel Attendance · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8318936
21 March 2025
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8097348
20 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7868445
4 August 2023
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7766027
27 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7663472
10 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7626420
13 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7505847
11 February 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7396699
25 October 2021
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7340094
3 May 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7191598
23 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7161501
28 December 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7117131
16 March 2020
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6930987
6 March 2020
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6883622
8 November 2019
Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6852410
4 November 2019
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6848824
1 August 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6785423
6 May 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6678355
25 April 2019
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6670676
2 January 2019
Deficiency Check · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6610789
24 October 2018
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6576720
22 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6566950
10 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6562593
27 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6549756
29 March 2018
Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6381850
8 December 2017
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6324944
8 November 2017
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6303447
10 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6284886
18 July 2017
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6212999
20 December 2016
Annual Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6060713
17 November 2016
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6057888
4 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5848125
6 January 2016
Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5792461
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2020
Resolved
Provide documentation indicating compliance with applicable regulations of 46 CFR Subchapter F for modified external MSD ventilation piping located port aft corner of superstructure. Documentation to be provided through submittal for plan review by the Marine Safety Center and verification of installation following MSC approval to the satisfaction of the attending marine inspector.
46 CFR 50.20, 46 CFR 56.01-10, 46 CFR 56.50-85,46 CFR 56.60.25
Action required: 705 - Other - as specified
Due 5 May 2021
Resolved 13 March 2023
Resolution: Received an email from vessel representative [name withheld] stating that MSD ventilation piping plan was submitted to MSC and has been approved. Vessel has not modified vent piping yet. CG inspector will verify compliance after modification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2019
Resolved
It was reported that the vessel's bow thruster is leaking oil near the shaft seal while in operation. Vessel is directed to not operate bow thruster until permanent repairs are conducted and proper operation is approved by USCG Marine Inspector.
46 CFR 91.25-35
46 CFR 58.30-1
46 CFR 58.25-1 (g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 6 March 2020
Resolution: Vessel's bow thruster output shaft seal was replaced by a Wartsila technical representative. Please see Wartsila Job No. F7166 for more details if needed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2019
Resolved
Each self-propelled vessel must be provided with a power driven pump or pumps connected to the bilge main as required by table 56.50-55(a). One of two required power driven bilge pump’s (aft pump) is inoperable. Authorized temporary installation of 180 gpm pneumatic pump. Replace or repair pneumatic pump with approved power driven pump and demonstrate proper operation to attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2019
Resolved 11 May 2019
Resolution: Rebuilt motor-driven bilge pump in the engineroom was satisfactorily tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2019
Resolved
All Vessels shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Multiple leaks were found on bilge piping in engine room space with temporary patches installed. Repair or replace bilge lines though out vessel, demonstrate water tight integrity of bilge piping system on board to attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2019
Resolved 11 May 2019
Resolution: Vessel's installed bilge system was satisfactorily tested at all manifolds and in all compartments/void spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2019
Resolved
Each self-propelled vessel must be provided with a power driven pump or pumps connected to the bilge main as required by table 56.50-55(a). One of two required power driven bilge pump’s (aft pump) is inoperable. Authorized temporary installation of 180 gpm pneumatic pump. Replace pneumatic pump with approved power driven pump and demonstrate proper operation to attending marine inspector.
46 CFR 56.50-55
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 7 May 2019
Resolution: Witnessed test of FWD power operated bilge pump. Newly installed rebuilt pump pulled suction to cam lock hose assembly into FWD bilge. Def 03 from ACT#6610789 cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 March 2019
Resolved
It shall be the responsibility of the master to assure himself that all exposed cargo hatches and other openings in the hull of his vessel are closed, made properly watertight by the use of tarpaulins, gaskets or similar devices, and in all respects properly secured for sea before leaving protected waters. Steering gear emergency escape hatch does not fully close and is not watertight. Demonstrate proper watertight closure of steering gear emergency escape hatch.
46 CFR 97.15-20
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 9 April 2019
Resolution: Witnessed satisfactory closure of hatch.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2019
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Crew has not conducted PSTP’s in the past 12 months and did not have a full approved list of procedures available to demonstrate tests.
46 CFR 61.40-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2019
Resolved 27 March 2023
Resolution: PSTP approval letter issued under MSC Letter E2-2300445 (14FEB23).
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 March 2019
Resolved
The marine inspector must inspect the steering gear twice within a 5 year period, and no more than 3 years may elapse between any inspection and its immediate predecessor. During inspection of the steering gear, steering rams were found with loose nuts on connections and starboard ram nut was missing. Tighten loose nuts and replace missing nut.
46 CFR 61.20-1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 9 April 2019
Resolution: Witnessed tightened/replaced nuts.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 March 2019
Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall of ‘A’ Class construction. Holes were found in the bulkheads for the engine control room, auxiliary machinery space, and emergency diesel generator space. Install proper structural fire protection in bulkhead holes.
46 CFR 92.07-10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 9 April 2019
Resolution: Penetrations properly sealed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 28 March 2019
Resolved
The routine maintenance of the oily water separating (OWS) equipment and the bilge alarm must be clearly defined by the manufacturer in the associated operating and maintenance manuals. All routine and repair maintenance must be recorded. OWS was inoperable. Demonstrate proper operation of OWS.
33 CFR 155.380(f)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 9 April 2019
Resolution: Witnessed satisfactory operation of OWS
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 March 2019
Resolved
Each hopper dredge must have sliding watertight doors (Class 3) approved under 170.270 of this chapter is installed below the bulkhead deck and less than 24 inches above the final waterline. Indicator light on bridge for auxiliary machinery WTD did not illuminate in the closed position and the local alarm continues to sound when it is closed. Repair bridge indicator and demonstrate proper operation of door alarm.
46 CFR 174.355
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2019
Resolved 9 April 2019
Resolution: Witnessed proper operation of display pannel and door alarm.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, MMSI: Vsl is broadcasting invalid MMSI
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 October 2018
Resolution: AIS discrepancy corrected, AIS broadcasting all pertinent information.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 8 December 2017
Resolved
Submit DVTPs/PSTPs to MSC for approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 27 March 2023
Resolution: PSTP approval letter issued under MSC Letter E2-2300445 (14FEB23).
Construction/Loadline › Hull › Side Shell
Issued 8 November 2017
Resolved
Make repairs to hole in spool piece of dredge piping. Repair plan must be submitted and approved by the Coast Guard. Make repairs prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2017
Resolved 8 November 2017
Resolution: A new spool piece was fabricated and replaced in kind. Non-destructive testing (dye pen) was satisfactory.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 18 July 2017
Resolved
DC01: Make Vessel available for inspection (emergency fire pump), post casualty; prior to conducting operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2017
Resolved 21 July 2017
Resolution: Vessel had motor refurbished by Tri-Motor & Machinery Co. Attending Marine Inspector witnessed satisfactory operation of the fire pump.