Records from 1985 to 1998. Most recent: inspection, 1 October 1998.
Inspection history · 39
1 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1440060
21 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792045
19 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778337
1 December 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1114037
10 October 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113099
9 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763088
10 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1428834
27 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 197227
27 January 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1101432
19 September 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456415
24 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088572
28 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245954
11 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764905
13 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201181
28 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077885
26 September 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411179
11 May 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438180
4 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67591
10 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 853408
15 December 1993
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1160385
3 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848109
12 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 685436
30 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 685437
20 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 31468
19 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 51369
15 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 178693
14 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 183554
18 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154318
13 May 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379790
20 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140670
20 May 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452899
10 December 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952720
23 August 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249279
5 June 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936166
12 December 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232842
22 November 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1210741
28 January 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029934
13 February 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325904
3 December 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996463
Fire Fighting
Issued 19 September 1996
Resolved
REPAIR FIRE PUMP IN MACHINERY ROOM.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Documentation
Issued 19 September 1996
Resolved
COMPLETE ALL OUTSTANDING DEFICIENCIES OUTLINED IN ABS SURVEY REPORT, DATED 13SEP96. LETTER OF COMPLIANCE CONTINGENT UPON ISSUANCE OF FINAL MODU SAFETYCERTIFICATE BY CLASSIFICATION SOCIETY.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Engineering
Issued 19 September 1996
Resolved
REPAIR EMERGENCY FUEL OIL SHUTDOWNS FOR F/O BOX GIRDER TANK AND DAY TANK. LABEL ALL EMERGENCY SHUT DOWNS.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 19 September 1996
Resolved
TEST AUTO-BUS TRANSFER AND TOTAL RIG SHUT-DOWN TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Fire Fighting
Issued 19 September 1996
Resolved
MAKE REPAIRS TO FIXED FIRE FIGHTING SYSTEM IN PROPULSION ROOM IDENTIFIED IN"FIREMASTER" REPORT, DATED 11SEP96.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Fire Fighting
Issued 19 September 1996
Resolved
INSTALL VENTS NEAR BOTTOM OF BATTERY ROOM DOORS AND REPAIR EXHAUST FANS.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Accommodation/Occupational Safety
Issued 13 May 1993
Resolved
MAKE TENSIONER BOTTLES AVAILABLE FOR INTERNAL EXAMINATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Deck/Cargo
Issued 13 May 1993
Resolved
REMOVE NON-APPROVED FORKLIFT FROM RIG/PROVIDE FORKLIFT APPROVED FOR CLASS IDIVISION 2 AREA.
Condition: Unknown
Due 30 May 1993
Resolved 27 May 1993
Electrical
Issued 5 June 1991
Resolved
REPLACE BULBS AND PROVIDE LENSES/GUARDS FOR EMERGENCY LIGHTS AS NEEDED.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Accommodation/Occupational Safety
Issued 5 June 1991
Resolved
REPAIR/REWIRE VENTILLATION SHUT-DOWN ON BULKHEAD INBOARD ENGINE ROOM BY EMERG FIRE PUMP.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
POUR EYS TO SWITCH BOX FOR SLUGGING PIT AGITATOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
REMOUNT JUNCTION BOXES, EXPL. PROOF LIGHTS, ETC, ABOVE #1 MUD PUMP AFTER INSTALLATION.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Accommodation/Occupational Safety
Issued 5 June 1991
Resolved
PERFORM LOAD TEST OF GENERAL ALARM BATTERIES.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Accommodation/Occupational Safety
Issued 5 June 1991
Resolved
REPAIR GENERAL ALARM CONTACT MAKER ON RIG FLOOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Accommodation/Occupational Safety
Issued 5 June 1991
Resolved
REPAIR OR REPLACE THE FOLLOWING GENERAL ALARM BELLS: HELO DECK, EMERG FIREPUMP, BY #4 L/B, AND OUTSIDE PAINT LOCKER.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Construction/Loadline
Issued 5 June 1991
Resolved
PROPERLY STENCIL NAME OF HAILING PORT.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Lifesaving
Issued 5 June 1991
Resolved
BUFF OR REPAINT #1, 2, 4 L/B'S.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Construction/Loadline
Issued 5 June 1991
Resolved
REPLACE FLANGE NUTS AND BOLTS TO CHECK VALVES FOR BILGE WELLS IN PORT OUTBOARD PUMP ROOM.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
SECURE ELEC. WIRING BELOW DECK PLATING IN PORT OUTBOARD PUMP ROOM.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Deck/Cargo
Issued 5 June 1991
Resolved
REPLACE BYPASS LINE FOR CHECK VALVES AS MARKED IN PORT OUTBOARD PUMP ROOM.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROVIDE PROTECTIVE COVERING FOR GEN #1 WHERE OPEN.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Construction/Loadline
Issued 5 June 1991
Resolved
REPAINT MARKINGS AND AIMING CIRCLES ON HELO DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Deck/Cargo
Issued 5 June 1991
Resolved
PROVIDE RELIEF VALVES OF PROPER SETTING (LESS THAN 2200 PSI) FOR SIX (6) APV'S MANUFACTURED AT SHAEFER TOOL WORKS.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Unknown
Issued 13 February 1987
Resolved
OPERATE ALL MOTOR LIFEBOATS IN THE WATER.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
SUBMIT LIFERAFT SERVICING CERTIFICATE FOR 8-25 MAN RAFTS TO THE [name withheld], LA
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
REPAIR OR REPLACE THE TWO(2) EMBARVATION LADDERS FROM THE SECOND LANDING TOTHE WATER
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
REPAIR (2) TWO INOPERABLE RING LIFE BUOY WATERLIGHTS AND REPLACE MISSING RING LIFE BUOY ON STBD
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Construction/Loadline
Issued 13 February 1987
Resolved
REPAINT LOADLINE MARKS AS NECESSARY PRIOR TO MOVING VESSEL FROM PRESENT LOCATION
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Electrical
Issued 13 February 1987
Resolved
MAKE AVAILBLE FOR COAST GUARD INSPECTION THE ELECTRICAL EQUIPMENT IN ALL HAZARDOUS AREA PRIOR TO COMMENCING DRILLIG OPERAITONS
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 13 February 1987
Resolved
REPLACE THE DOG PINS ON THE MANHOLES DOGS ON BULK TANKS ONE(1) AND THREE(3)THAT ARE NOT FITTED WITH RETAINING CLIPS PRIOR TO PRESSURIZING
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 13 February 1987
Resolved
PROVIDE ALL DOG BOLTS ON THE BULK TANK MANHOLES THAT HAVE THE WRONG NUTS @ 20 EACH PRIOR TO PRESSURIZING.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 13 February 1987
Resolved
TEST ALL RELIEF VAVLES ON ALL AIR RECEIVERS INT THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Electrical
Issued 13 February 1987
Resolved
REPLACE RENEABLE LINK FUESES IN THE GENERAL ALARM PANEL AS PER 5.5.6.2 IMO FUESES ARE OVER RATED FOR THE SYSTEM.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Fire Fighting
Issued 13 February 1987
Resolved
PROVIDE RELIEF VALVE ON THE FOAM TANK SET AT LESS THAN THE MAWP OF THE TANK
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 13 February 1987
Resolved
PROVIDE OPERABLE HAND RECIEVING GEAR ON THE OIL-AIR SEPARATER RELIEF VAVLE FOR THE AIR COMPRESSORS IN THE GENRATOR ROOM.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Deck/Cargo
Issued 13 February 1987
Resolved
PROVIDE OPERABLE HAND RELIEVING GEAR ON THE ANCHOR WINDLASS AIR RECIEVERS, STB FORWARD AND STBD AFT
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
REPLACE OR CLEAN HATCH GLASS ON ALL LIFEBOATS.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Lifesaving
Issued 13 February 1987
Resolved
MAKE OPERABLE THE WINCH CONTROLLER FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Deck/Cargo
Issued 13 February 1987
Resolved
REPAIR WASTED GRATING PORT STERN ANCHOR WINDLASS
Condition: Unknown
Due 13 February 1987
Resolved 13 February 1987
Accommodation/Occupational Safety
Issued 3 December 1985
Resolved
INSTALL STORM-SAFETY-GUARD RAILS THROUGHOUT THE INTERIOR PASSAGEWAYS.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985