MAURY USCG vessel records Sign in
← All vessels

REPUBLIC TIDE

REPUBLIC TIDE is a 1977 offshore supply vessel. The Coast Guard has recorded 75 inspections since 1980, most recently in May 2012, along with 42 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2006 and 2012.

Records from 1980 to 2012. Most recent: inspection, 23 May 2012.

Built
1977
Last inspected
23 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7502526 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7611
Flag
UNITED STATES
303411000, 338592000 (licence lapsed)
Maury page id
psix-49042

Inspections, by type

…with no type recorded25
…past their stated due date1
Years with a record 27 calendar years (1980–2012)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1025 - Convention (Subpart B), Gross Ton
307 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7611MMSI 303411000 · cancelled · compulsorily equipped · granted 5 May 2004, cancelled 4 December 2013
WYH7214MMSI 338592000 · cancelled · compulsorily equipped · granted 26 August 1997, cancelled 30 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TRITON ACHIEVER Industrial Vessel · MISLE 49851 · 18 May 2012 · activity 4317503HERCULES 153 Mobile Offshore Drilling Unit · MISLE 398047 · 8 June 1999 · activity 118030OCEAN PROSPECTOR Mobile Offshore Drilling Unit · MISLE 240839 · 20 June 1992 · activity 140670

Inspection history · 75

23 May 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4319980
18 May 2012 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4315148
18 May 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4317503
15 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3650941
9 October 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3341272
22 October 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3087594
12 March 2007 Internal Structural Exam · Annual Inspection · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2887324
6 February 2007 Administrative Inspection · SIP Inspection/Audit
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2915182
1 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2865593
31 October 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2812569
21 August 2006 COI Inspection · Deficiency Check · SIP Inspection/Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2754699
30 November 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2543491
10 November 2005 Re-Inspection · SIP Initial Entry
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2531642
20 June 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2406036
17 February 2005 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2294228
4 January 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2268438
16 November 2004 MTSA Verification · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2243910
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971414
27 August 2003 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1888576
24 September 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1679816
13 February 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489377
31 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41894
29 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23959
29 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1069068
16 August 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1070864
14 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822963
14 September 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405048
10 December 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 666020
10 December 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 723207
29 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781434
8 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 118030
8 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 212097
8 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 213238
8 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 228033
17 November 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805858
23 September 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1375496
5 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800268
21 July 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129611
8 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423024
3 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783281
15 October 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782407
14 October 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773925
9 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774157
29 August 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377907
9 September 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357755
31 May 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1085413
22 May 1996 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085430
22 May 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470689
23 February 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 885093
16 November 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439668
7 June 1995 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185755
5 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 454422
1 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 457460
30 November 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370956
29 November 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463791
6 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 651258
29 April 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 88154
18 April 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 130116
13 January 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827045
10 December 1992 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 826606
3 December 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 125735
21 September 1992 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387271
20 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 140670
10 December 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260755
4 May 1991 Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919219
15 December 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216217
18 October 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921619
8 December 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 918194
13 October 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199213
4 September 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313972
29 October 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018419
17 March 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309243
27 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988522
10 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288650
9 October 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273916

Deficiency record · 42

Communications › Public Address System › Loudspeaker
Issued 9 October 2008 Resolved
Install addtional Loudspeaker on 01 deck to service berthing spaces
Due 9 November 2008
Resolved 10 October 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 October 2008 Resolved
Repair Exhaust Leak Stbd Main Engine
Due 9 November 2008
Resolved 10 October 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 9 October 2008 Resolved
Install Fire Alarm Horns in Engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Fire Fighting › Fire Pumps › Pressure
Issued 9 October 2008 Resolved
Replace or repair Fire Pump Guage on Bridge
Due 9 November 2008
Resolved 10 October 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 9 October 2008 No resolution recorded
Hydo-date on several tanks were to expire befor next inspection, have tanks tested and put back into service.
Due 1 February 2009 — due date passed with no resolution recorded
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 October 2008 Resolved
Lable Fuel Shut-offs on main deck
Due 9 November 2008
Resolved 10 October 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 23 August 2006 Resolved
DEMONSTRATE PROPER OPERATION OF SOUND POWERED PHONE LIGHT IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: PHONE LIGHT OPERATIONAL
Engineering › Fuel Oil Service System › Pump
Issued 23 August 2006 Resolved
REPAIR PRE LUME PUMP LEAK PRIOR TO SILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: PUMP LEAK REPAIRED.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 August 2006 Resolved
PROVIDE AND INSTALL EXHAUST INSULATION IN PASSAGEWAY ENGINE ROOM ON MAIN ENGINE.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: INSTALLED WXHAUST INSULATION.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 August 2006 Resolved
RENEW ONE STARBOARD AND ONE PORT VERTICAL ANGLE ON FORWARD MAIN DECK BULKHEAD AND REPAIR CRACKS ON STARBOARD BIT FOUNDATION PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: REPAIRED ANGLES AND BIT.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 August 2006 Resolved
COMPLETE MAIN ENGINE FLEX FLANGE REPAIRS.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: REPAIRS TO FLEX FLANGE COMPLETED.
Operations/Management › Streamlined Inspection Program › VAP Review and Revision
Issued 23 August 2006 Resolved
REVIEW SIP PROGRAM AND UPDATE ALL DOCUMENTATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: UPDATED DOCUMENTATION AND CONDUCTED INTERNAL AUDIT.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 August 2006 Resolved
REPAIR DRYER HOSE AS DISCUSSED AND REMOVE EXCESSIVE LINT BUILD UP BEHIND DRYER.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 25 August 2006
Resolution: HOSE RENEWED AND LINT REMOVED.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 23 August 2006 Resolved
REMOVE FREEZER OR SECURE TO DECK ON 01 DECK IN VICINITY OF EGRESS EXIT.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: REMOVED FREEZER.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 August 2006 Resolved
UPDATE SOPEP WITH CORRECT CALL SIGN AND VSL SPECIFIC INFORMATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: ALL DOCUMENTATION UPDATED.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 23 August 2006 Resolved
PUMP WASTE OIL/FUEL OIL FROM ENGINE ROOM BILGE PRIOR TO OPERATING VSL.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 25 August 2006
Resolution: REMOVED EXCESSIVE WASTE OIL FROM BILGE.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 August 2006 Resolved
REPAIR PORT EGRESS RAIL PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: REPAIRED PORT EGRESS RAIL.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 August 2006 Resolved
PROVIDE CURRANT AND CORRECT FIRE SAFETY PLAN FOR APPROVAL TO ATTENDING MARINE INSPECTOR PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 25 August 2006
Resolution: PROVIDED CORRECT UPDATED FIRE SAFETY PLAN.
Construction/Loadline › Structures › Door
Issued 21 August 2006 Resolved
REPAIR PORT AND STARBOARD MAIN DECK DOORS, ENGINE ROOM DOOR GASKET PRIOR TO SAILING.
Action required: 705 - Other - as specified
Due 23 August 2006
Resolved 25 August 2006
Resolution: REPAIRS TO DOORS COMPLETE.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 21 August 2006 Resolved
PROVIDE APPROVED LIFELINE AND ATTACH CORRECTLY TO RING BOUY.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2006
Resolved 23 August 2006
Resolution: COMPLETED.
Lifesaving
Issued 8 May 1998 Resolved
PROVIDE RESCUE BOAT AND LAUNCHING/RECOVERY ARRANGEMENTS AS PER 46CFR133.135/133.140/133.160.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Fire Fighting
Issued 8 May 1998 Resolved
PROVE PROPER OPERATION OF PILOT HOUSE FIRE PUMP PRESSURE GUAGE.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 8 May 1998 Resolved
LABEL EMERGENCY STOPS BOTH LOCAL AND REMOTE FOR WELL STIMULATION EQUIPMENT,CONTROL BOOTH, PILOT HOUSE, GALLEY AND ON MACHINERY.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 8 May 1998 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM, GENERAL ALARM CONTACT MAKER, FIRE ALARM AND EMERGENCY LIGHT IN CONTROL BOOTH.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Documentation
Issued 8 May 1998 Resolved
SUBMIT FOR APPROVAL OPERATION MANUAL COVERING ALL ASPECTS OF WELL STIMULATION EQUIPMENT OPERATIONS, HAZARDOUS MATERIAL HANDLING, SPILL RESPONSE, PERSONNEL PROTECTION, FIRE FIGHTING AND FUEL OIL TRANSFER._x001C_ _x001C_
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Fire Fighting
Issued 8 May 1998 Resolved
PROVIDE UPDATED FIRE SAFETY PLAN TO REFLECT INSTALLATION OF NEW FIRE FIGHTING EQUIPMENT BOTH FIXED AND PORTABLE. ALSO INSTALLATION OF EMERGENCYSHUTDOWNS FOR WELL STIMULATION EQUIPMENT.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Documentation
Issued 29 August 1997 Resolved
SUBMIT CORRECTED SAFETY PLAN FOR APPROVAL.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 29 August 1997 Resolved
SUBMIT CORRECTED FIRE PLAN FOR APPROVAL.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Engineering
Issued 29 August 1997 Resolved
POST FUEL TRANSFER PROCEDURES AT FUEL TRANSFER PUMP.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 29 August 1997 Resolved
PROVIDE AUTOMATION TEST PROCEDURES MANUAL.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 29 August 1997 Resolved
PROVIDE APPROVED DRAWINGS FOR: 1. FIRE ZONE BOUNDRY 2. FIRE DETECTION AND C02 SYSTEM 3. FIRE MAIN PIPING.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Documentation
Issued 29 August 1997 Resolved
PROVIDE NVIC 10-82 ABS COMPLETION LETTER.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Accommodation/Occupational Safety
Issued 9 September 1996 Resolved
PRIOR TO PLACING THE FOLLOWING DRY BULK TANKS BACK IN SERVICE, LOCATED PORTSIDE AFT & STBD SIDE FWD, MAKE PERMANENT REPAIRS DUE TO WASTAGE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Accommodation/Occupational Safety
Issued 9 September 1996 Resolved
PROVIDE P.E.-CERTIFIED MAWP CALC'S BASED ON WASTED AREA IN SHELL OF P-TANK LOCATED STBD SIDE AFT ALONG W/ A NEW NAMEPLATE SHOWING REDUCED MAWP (EST @ 32PSIG), REMOVE FROM SERVICE OR REPAIR TO THE SATISFACTION OF THE ATTENDINGUSCG MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1996
Resolved 9 September 1996
Navigation
Issued 21 September 1992 Resolved
PROVIDE PROOF OF PROPER ADJUSTMENT OF MAGNETIC COMPASS.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Documentation
Issued 21 September 1992 Resolved
DISPLAY PLANS THAT ARE IAW 46CFR97.36-1
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Electrical
Issued 10 December 1991 Resolved
REPAIR OR REPLACE AS NECESSARY 110 VAC TRANSFORMER FOR UPPER LEVEL CIRCUIT (BRIDGE, ETC.) AND PROVE PROPER OPERATION INCLUDING EMERGENCY LIGHTING ON BRIDGE, SECOND BATTERY AND AND CHARGING SYSTEM TO BRIDGE EMERGENCY POWER SYSTEM.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Navigation
Issued 10 December 1991 Resolved
REPAIR FAULTY GYROCOMPASS AND REPEATER AS NECESSARY. PROVE PROPER OPERATION.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 10 December 1991 Resolved
OBTAIN SPARE O2 BOTTLE FOR OBA.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Construction/Loadline
Issued 10 December 1991 Resolved
REPLACE MISSING ENGINE ROOM ESCAPE TRUNK DOGS.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 18 October 1990 Resolved
PROVIDE PROPERLY SERVICED LIFERAFT TO REPLACE PORT LIFERAFT AS REQUIRED BY 46CFR97.15-45. TOTAL PERSONS ON BOARD ARE LIMITED TO TEN (10) UNTIL BOTH LIFERAFTS ARE ON BOARD AND PROPERLY SERVICED. SERVICING REPORTS MUST BE SUBMITTED TO [name withheld].
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990
Deck/Cargo
Issued 18 October 1990 Resolved
HAVE P-TANKS DUST FREE AND CERTIFIED GAS FREE BY A MARINE CHEMIST FOR INSPECTION AT THE NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 18 October 1990
Resolved 18 October 1990

Casualty record · 2

31 October 2006Routine · role: Involved in a Marine Casualty · activity 2812569
18 May 2012Routine · role: Involved in a Marine Casualty · activity 4317503
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record