Records from 1994 to 2010. Most recent: inspection, 13 January 2010.
Inspection history · 26
13 January 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3658027
21 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3458683
12 January 2009
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3392959
2 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3337105
23 January 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3135188
30 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2653315
4 February 2002
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1483573
24 April 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1062552
19 February 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457884
14 February 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440251
13 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811653
8 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198995
8 June 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 118030
1 May 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 30936
1 May 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 49420
26 February 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1430646
14 May 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1125874
28 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 789635
2 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456583
3 March 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416453
25 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078944
8 March 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453210
19 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186631
23 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1135607
9 March 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355122
15 March 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396068
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 15 January 2010
No resolution recorded
Vsl missing non-conducting mating around E-Gen switchboard.
Condition: Improper Installation
Due 28 January 2010 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 15 January 2010
No resolution recorded
Vsl missing proper operation instructions for CO2 fire suppression system serving the generator room.
Condition: Improper Installation
Due 28 January 2010 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 January 2010
No resolution recorded
Vsl needs to ensure diesel fuel day tank and associated piping does not leak and repairs are made.
Condition: Improper/Lack of Maintenance
Due 28 January 2010 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 January 2009
Resolved
Fire Control Plan did not relfect installed fire doors. Submit changes to flag state for review and approval.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 14 January 2010
Resolution: Vsl obtained a new fire control plan reflecting changes to fire doors.
Fire Fighting › Firemans Outfit › Helmet
Issued 15 January 2009
Resolved
Firemans helmet did not meet ANSI standards.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 21 April 2009
Resolution: Produced approved fire helmet
Documentation › Logs/Records › Garbage Recordkeeping
Issued 15 January 2009
Resolved
Garbage logs not up to date. Ensure all transfers are logged.
Action required: 705 - Other - as specified
Due 15 February 2009
Resolved 21 April 2009
Resolution: Garbage log updated and current
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 January 2008
Resolved
CO2 flex loop discharge hose on fixed fire system on the outboard generator room is degreraded and needs replacing per fire serving report.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 15 January 2009
Resolution: Verified correction during annual inspection. //s// [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 30 January 2008
Resolved
No test records for oil transfer hoses.
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 15 January 2009
Resolution: Verified correction during annual inspection. //s// [name withheld]
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 30 January 2008
Resolved
Remote operation control for galley hood fire extinguishing system
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 15 January 2009
Resolution: Verified correction during annual inspection. //s// [name withheld]
Lifesaving › Lifeboat Equipment › Painter
Issued 30 January 2008
Resolved
Properly equip lifeboats number 1 and 2. Lifeboats missing seasick bags, painters, search lights, water collection kits, and seasick tablets.
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 15 January 2009
Resolution: Verified correction during annual inspection. //s// [name withheld]
Documentation › Logs/Records › Oil Record Book
Issued 23 January 2008
Resolved
Completed pages not signed in Oil Record Book.
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 30 January 2008
Resolution: OIM signed completed pages of Oil Record Book
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 January 2008
Resolved
Update fire control plan to reflect actual construction and Class A boundaries. No Class A door was ever installed on main deck to control room ladder but is shown as having one on the Fire Control Plan.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 15 July 2008
Resolution: Added again during annual inspection. //s// [name withheld]
Operations/Management › Drills/Instruction › Fire
Issued 4 February 2002
Resolved
Conduct fire drill when fully crewed and prior to operation.
Action required: 705 - Other - as specified
Due 4 May 2002
Resolved 5 February 2008
Resolution: Legacy
Electrical › Electric Supply System (service)
Issued 4 February 2002
Resolved
Repair Repalce battery box for emergency generator. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 4 March 2002
Resolved 13 February 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2002
Resolved
Prior to operation all dead end wires on the drill floor to be terminated in metal junction box or removed. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2002
Resolved 5 February 2008
Resolution: Legacy
Lifesaving › Launching Appliances › Falls
Issued 4 February 2002
Resolved
Conduct lifeboat weight test and provide MSO Port Arthur with test results.
Condition: Unknown
Due 4 March 2002
Resolved 13 February 2002
Electrical
Issued 19 February 2001
Resolved
RENEW / REPLACE HOLED BATTERY BOXES.
Condition: Unknown
Due 19 February 2001
Resolved 19 February 2001
Lifesaving
Issued 19 February 2001
Resolved
RENEW / REPLACE DOOR TO PAINT LOCKER.
Condition: Unknown
Due 19 February 2001
Resolved 19 February 2001
Accommodation/Occupational Safety
Issued 19 February 2001
Resolved
RENEW / REPLACE HOLDING TANK FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 19 February 2001
Resolved 19 February 2001
Unknown
Issued 14 February 2000
Resolved
REPAIR PURGE ALARM ON DRILL FLOOR. PROPERLY TEST IN PRESENCE OF MARINE INSPECTOR OR CLASS SURVEYOR PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 23 February 2000
Resolved 25 February 2000
Electrical
Issued 14 February 2000
Resolved
PROVE PROPER OPERATION OF # 2 EMD MAIN ENGINE LOW LUBE OIL SHUT DOWN IN PRESENCE OF MARINE INSPECTOR OR CLASS SURVEYOR.
Condition: Unknown
Due 16 March 2000
Resolved 25 February 2000
Electrical
Issued 14 February 2000
Resolved
VERIFY EMERGENCY LIGHTING AT BOTH LIFEBOAT EMBARKATION AREAS AND LABEL WITHRED "E". REPLACE LIFEBOAT # 2 WINDOWS IN COCKPIT AND REPAIR AFT OAR YOLK ONCANOPY. VERIFY AIR BOTTLE HYDRO DATES ON LIFEBOAT # 1.
Condition: Unknown
Due 23 February 2000
Resolved 25 February 2000
Electrical
Issued 14 February 2000
Resolved
PROPERLY MOUNT JUNCTION BOXES IN MUDPITS, DRILLERS SHACK AND # 2 GENERATOR ROOM. REMOVE ALL DEAD-END WIRING IN # 2 GENERATOR ROOM AND DRILL FLOOR, ANDPROVIDE METAL BANDING FOR WIRES IN DRILLERS SHACK.
Condition: Unknown
Due 16 March 2000
Resolved 25 February 2000
Lifesaving
Issued 2 March 1998
Resolved
Demonstrate compliance with all of the requirements contained in the 1996 edition of 46CFR109; specifically 109.213. All new requirements for training and conducting of the various drills shall be initiated and loggedin accordance with the referenced regulations.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Fire Fighting
Issued 2 March 1998
Resolved
Replace recently installed unapproved stainless steel foam agent portable fire extinguishers with Coast Guard approved B-II rated fire extinguishers.See 46CFR Table 108.495(b) for extinguishing agent options for B-II rated extinguishers. Amend Fire Control Plan if agent is changed from foam.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 2 March 1998
Resolved
Amend current Station Bill(s) to reflect rig name change and to ensure thatfour (4) required Lifeboatmen are evenly distributed between the two lifeboats by their respective billet positions._x001C_ _x001C_
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 2 March 1998
Resolved
Clean, repair, or replace following items on port and stbd lifeboats: a) expired items in first aid kits, b) all portholes (windows) with overspray and/or glazing, c) overspray on hull exteriors (restencil information required by SOLAS and reapply SOLAS reflective tape.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Navigation
Issued 3 March 1997
Resolved
REPLACE STARBOARD NAVIGATION LIGHT LENS ASSEMBLY AND PAINT SCREEN MATTE BLACK.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997
Resolved
COMPLY WITH THE REVISIONS TO 46CFR107-109.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997
Resolved
PROVIDE PROPER AMOUNT OF DRINKING WATER AND REPAIR INTERIOR LIGHTING FOR BOTH LIFEBOATS.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Construction/Loadline
Issued 3 March 1997
Resolved
ADJUST WATERTIGHT DOORS TO PIT ROOM.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 3 March 1997
Resolved
PROVIDE PROPER TRAINING FOR ALL PERSONS THAT MAY BE REQUIRED TO WEAR AND USE SCBA.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Documentation
Issued 3 March 1997
Resolved
OBTAIN AND PROVIDE ON BOARD AN APPROVED EEP.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Deck/Cargo
Issued 8 March 1996
Resolved
REPAIR AT AMSE AUTHORIZED SHOP OR REPLACE WITH IN KIND, THE THREE FOR CEMENT P TANKS. REPLACE PRIOR TO PRESSING UP TANKS AGAIN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Lifesaving
Issued 8 March 1996
Resolved
REPAIR AND/OR REPLACE GENERAL ALARM. PROVE PROPER OPERATION OF ALL GENERALALARMS AND ROTATING BEACONS. (COMPRESSION ROOM, MUD PIT ROOM, SHAKER AREA).
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Electrical
Issued 8 March 1996
Resolved
REPAIR OR REPLACE #1 AC GENERATOR CIRCUIT BREAKER PANEL SWITCH CONTROLLER.
Condition: Unknown
Due 26 March 1996
Resolved 26 March 1996
Documentation
Issued 9 March 1995
Resolved
PROVIDE ORIGINAL CERTIFICATES ON BOARD FOR FOLLOWING: LOADLINE CERTIFICATE,IOPP CERTIFICATE WITH ATACHMENT, MODU CODE CERTIFICATE AND PROVIDE COPY OF IOPP ATTACHMENT AND IMO MODU CODE CERTIFICATE TO MSO NEW ORLEANS, ATTN: [name withheld].
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Documentation
Issued 9 March 1995
Resolved
SUBMIT OPERATING MANUAL TO [name withheld] FOR REVIEW AS REQUIRED BY NVIC 3-88.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Fire Fighting
Issued 9 March 1995
Resolved
PROVIDE RELIEF VALVE IN FIRE MAIN IN ACCORDANCE WITH IMO MODU CODE 9.4.9 DUE TO HIGH PRESSURE (160 PSI) OUTPUT.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995