Records from 1985 to 2021. Most recent: inspection, 12 October 2021.
Documentation record
Registered dimensions (L × B × D)142.0 ft × 27.5 ft × 14.6 ft
Registered tonnagegross 299 / net 163
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWHITNEY BROTHERS COMPANY · SUPERIOR, WI, UNITED STATES · built 1919
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAGINAW, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
163 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
12 October 2021
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7366004
12 March 2020
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6925419
29 August 2018
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6528433
7 July 2017
Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 6379369
13 September 2012
Industry Initiated Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4445001
30 August 2012
Administration
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4426100
28 June 2007
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2976245
23 June 2007
Uninspected Other
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2970982
26 October 2006
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2810417
3 January 1997
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 721298
3 January 1997
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 721299
28 December 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 34914
18 November 1996
Uninspected Towing Vessel
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1179774
14 November 1996
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 106026
23 November 1994
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3972
17 April 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 166727
22 June 1989
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 886439
27 September 1985
Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1299813
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 March 2020
No resolution recorded
All owner and operators of an existing towing vessel must have a valid COI prior to the specified phase in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI by the specified phase in period of 22JULY2019. The vessel shall be made available for a CG COI inspeciton within 90 days. If an inspection is not completed prior to this date (20MAY20), the action for this deficiency shall be changed to a 60 (rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate. 705c (rectify deficiency within 90 days)
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 August 2018
Resolved
Vessel’s bilges contain excessive amounts of oil. Oil leaks and residues also cover numerous electrical installations, machinery and surfaces creating significant fire hazards. Oil accumulations and residues are to be sufficiently cleaned to eliminate fire and pollution hazards. To be cleared by an attending CG Inspector prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 November 2018
Resolution: Entire engine room was pressure washed. Excess oil was sufficiently cleaned from equipment and bilges. 6000 gallons of oil water was legally disposed of.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 August 2018
Resolved
Vessel’s fire detection panel appears to be inoperable at this time. A properly functioning CG approved fire detection system must be installed and operable and IAW 142.330. As an alternative due to vessel’s age, a pre-existing engine room monitoring system may be used if it meets 142.330 (a) 2 thru 7, if one is already installed and properly functioning. To be cleared by an attending CG Inspector prior to sail.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 November 2018
Resolution: Fire detection panel displayed a current servicing tag from Gale Fire Protection, INC. CAPT was able to demonstrate 24 volt power back up.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 August 2018
Resolved
Vessel’s fire extinguishing equipment does not appear to be functional at this time. Vessel is required at a minimum to have either an approved 160-B semi-portable fire-extinguishing system to protect the engine room; or an accepted fixed fire-extinguishing system installed to protect the engine room. Fire extinguishing equipment must also be inspected, tested, and maintained IAW 142.240. To be cleared by an attending CG Inspector prior to sail.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 November 2018
Resolution: CO2 bottle arrangement for engine room and semi portable extonguisher displayed a current servicing tag from Gale Fire Protection, INC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2018
Resolved
Vessel’s engine room was found to have numerous electrical hazards such as dead ended wires, open junction boxes, loose electrical connections and unprotected light fixtures. As required by 143.400 all such hazards are to be eliminated by removal or correction by proper installation. To be cleared by an attending CG Inspector prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 November 2018
Resolution: Electricsl connections terminated in junction boxes. Missing light fixtures had new bulbs and protective covers installed.