Inspection history · 51
17 March 2026
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8326925
6 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8129645
21 November 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8038271
10 June 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7937611
20 June 2023
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7719038
22 June 2022
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7484204
1 April 2021
COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7166083
8 July 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7013162
4 November 2019
Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6875971
19 June 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6723933
3 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6411206
1 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6136408
25 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6133857
2 March 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5825238
4 February 2015
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5071430
1 October 2014
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5002305
2 April 2014
Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4827955
10 February 2012
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4242044
29 November 2011
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4197524
1 December 2010
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3900381
24 March 2010
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3702226
31 March 2009
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3445711
25 March 2008
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3167067
5 April 2007
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2902526
15 February 2006
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2585176
29 March 2005
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2321713
25 February 2005
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2299319
31 March 2004
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2034882
8 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1614545
22 February 2001
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1459666
28 April 2000
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1048999
6 April 2000
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1418686
9 March 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1464158
25 February 1998
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1398845
12 February 1997
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1460932
13 February 1996
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1411234
6 August 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 78457
17 February 1995
COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 847878
24 May 1994
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1018150
9 March 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 854505
23 February 1994
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 851139
3 March 1993
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1144420
19 February 1992
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009708
26 February 1991
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1234528
22 February 1990
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 913215
9 February 1990
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1232475
22 February 1989
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1041977
26 February 1988
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1334596
25 February 1987
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1002641
6 March 1986
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 988417
28 February 1985
Type not recorded
No type recorded · MSO NASHVILLE · Activity 1283934
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2020
Resolved
Special Flashing Yellow light not Working
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 9 July 2020
Resolution: Replaced wiring.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 April 2017
Resolved
Adult lifejacket quantiy does not meet requirements. Add four adult jackets to meet required thirty-one. Mark in block, clearly legibel letters, the vessel's name per 46CFR 185.604.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2017
Resolved 1 May 2017
Resolution: Added and Marked life jackets appropriately
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 April 2017
Resolved
Child size life jackets not stowed in location appropriatley marked and seperated from adult sizes. Stor and mark, accordingly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2017
Resolved 1 May 2017
Resolution: Child life jackets stored appropriately
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 April 2017
Resolved
Number and identification of lifejackets not clearly marked. Mark accordingly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2017
Resolved 1 May 2017
Resolution: Correct number and marked accordingly.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 April 2017
Resolved
Water light battery expiration unknown: replace batteries annually if not marked with expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: New batteries installed and marked with date on battery and outside of light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017
Resolved
Nav running light - yellow flashing - inoperable. Repair prior to night or limited visibility ops to specs per Inland Rules of the Road.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 1 May 2017
Resolution: Sensor replaced, checked and operational.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017
Resolved
Nav running light - green - falling off mount. Repair prior to night or limited visibility ops to specs per Inland Rules of the Road.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 1 May 2017
Resolution: Nave light repaired and operational.
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 October 2014
Resolved
Longitudinal frames on both fwd and aft ramps wasted.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 3 December 2014
Resolution: Longitudinal frames on both forward and aft ramps removed and replaced. New Timbers installed.
Construction/Loadline › Hull › Transverse Frame
Issued 1 October 2014
Resolved
#1 port void has 4ft of overhead transverse frame wasted.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 3 December 2014
Resolution: Transverse frame removed and replaced with a new one.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 February 2012
Resolved
The battery for the float lights are of the spring type, but the connection clips are designed for post type batteries. Ensure correct batteries are used for float lights in accordance with manufacturers guidelines. The lifeline for the ring buoy was weathered and brittle. Replace lifeline with new one that meets the applicable requirements in 46 CFR 180.70(c) for size and type.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 17 April 2012
Resolution: The battery for the life float has been replaced with a post type battery and the lifeline has been replaced.
Electrical › Lighting (service) › Outlet Box
Issued 24 March 2010
Resolved
An outlet box at the stbd bow was missing a cover plate exposing the wiring to weather.
Due 30 April 2010
Resolved 16 June 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 March 2010
Resolved
Batteries in engine room must be covered.
Due 30 April 2010
Resolved 1 April 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 March 2010
Resolved
The altenator belt on the main engine has no safety guard.
Due 30 April 2010
Resolved 16 June 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 March 2010
Resolved
The Shaft at the entrance to the E/R is not guarded and is exposed and should be guarded.
Due 30 April 2010
Resolved 16 June 2010
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 24 March 2010
Resolved
Re-install tachometer on Main diesel engine.
Action required: 705 - Other - as specified
Due 20 February 2011
Resolved 1 December 2010
Resolution: New tachometer has been installed on engine for M/V LUCILLE II.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 April 2009
Resolved
Company has failed to submit MIS Report to Department of Transportation for calendar year 2008. Provide proof of MIS Report submittal to attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 14 May 2009
Resolution: Company provided proof of MIS Report submittal to USDOT for calendar year 2008.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 April 2009
Resolved
The vent for the fuel tank is not fitted with the appropriate mesh size flame screen. Fuel vents must be fitted with a 30-by-30 mesh corrosion resistant flame screen.
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 20 May 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 February 2006
Resolved
Install battery box in engine room of tow vessel [name withheld] w/cover IAW 46 CFR 183.354.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 February 2006
Resolved
Provide proof of 50% crew CPR and First Aid qualification.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 February 2006
Resolved
Provide proof and install PFD donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 14 March 2006
Fire Fighting
Issued 9 March 1994
Resolved
HYDROSTATICALLY TEST BOTH PORTABLE CO2 EXTINGUISHERS ON BOARD IN ACCORDANCEWITH NFPA 10, 5 YEAR HYDROSTATIC TEST REQUIRED.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Documentation
Issued 23 February 1994
Resolved
REPOST MARPOL V GARBAGE POLLUTION PLACARD, EMERGENCY PROCEDURES, AND CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Accommodation/Occupational Safety
Issued 23 February 1994
Resolved
PROVIDE MORE POSITIVE MEANS OF SECURING THE FORE AND AFT GATES.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Lifesaving
Issued 23 February 1994
Resolved
RESTENCIL VESSEL NAME ON RING BUOY.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Fire Fighting
Issued 6 March 1986
Resolved
FIRE HOSE NOZZLE WAS MADE OF PLASTIC MATERIAL. PROVIDE A PROPER METALIC NOZZLE AS REQUIRED BY 46 CFR 181.15(D)(2).
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Unknown
Issued 28 February 1985
Resolved
INSTALL WARNING SIGNS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Unknown
Issued 28 February 1985
Resolved
RENEW RADIO LICENSE FOR VESSEL.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985