MAURY USCG vessel records
← All vessels

USNS 2ND LT. JOHN P. BOBO

USNS 2ND LT. JOHN P. BOBO is a 1985 freight ship. The Coast Guard has recorded 44 inspections since 2016, most recently in July 2025, along with 54 deficiencies, 2 operational controls and 9 casualty investigations between 1997 and 2021.

Records from 1997 to 2025. Most recent: inspection, 18 July 2025.

Built
1985
Last inspected
18 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 July 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8219384
245108
Flag
UNITED STATES
Maury page id
psix-245108

Documentation record

Tonnage as PSIX records it26523 - Dead Weight, Ton
32903 - Regulatory (Subpart C or D), Gross Ton
44543 - Convention (Subpart B), Gross Ton
25384 - Regulatory (Subpart C or D), Net Ton
14461 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

44 inspections, each with its date, unit and type; 54 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 1 other recorded name, with years; 9 casualty investigations, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

18 July 2025 Exemption · Administrative Inspection · Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8183251
13 November 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8043358
23 May 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7918098
11 April 2024 Damage Survey · Permit to Proceed
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7893704
8 April 2024 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7891535
25 March 2024 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7884596
16 February 2024 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7866727
4 October 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7802816
14 June 2023 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7715010
4 April 2023 ACP Additional Oversight – Risk Assessment · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7658937
2 December 2022 Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7606624
20 October 2022 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7580755
27 September 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7567637
6 May 2022 Deficiency Check · Annual Inspection · ACP Periodic Oversight · ACP Additional Oversight – Risk Assessment · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7454261
30 January 2022 Administrative Inspection · Examination of Repairs
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7387949
16 October 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7334543
15 August 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7294895
15 August 2021 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7294899
4 August 2021 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7276874
18 May 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7321224
12 March 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7156155
5 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7121221
17 December 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7113184
26 October 2020 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7084188
9 October 2020 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7074555
19 September 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7089589
19 September 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7109098
3 February 2020 ACP Additional Oversight – Risk Assessment · Administrative Inspection · ACP Drydock Oversight · Underwater Inspection in lieu of Drydock · ACP COI Oversight · Re-Inspection · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6904158
15 November 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6856576
12 November 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6857320
16 June 2019 ACP Annual Oversight · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6716093
16 May 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6790104
10 April 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6697671
15 March 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6656334
13 February 2019 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6626265
30 September 2018 Deficiency Check · Periodic Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6551953
19 March 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6374425
12 March 2018 ACP Annual Oversight · Annual Inspection · Administrative Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6369951
17 May 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6148369
24 February 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6094079
24 February 2017 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6135995
9 December 2016 ACP COI Oversight · Periodic Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6055386
21 October 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6029588
25 August 2016 Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5975879

Deficiency record · 54

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #4 life raft was missing 01 required bursting band. Total persons allowed reduced to 160. 74 SOLAS (20 Cons.) I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. SOLAS training manual was found not IAW the vessel's approved Fire Control Plan, which did not match the physical location of the vessels life rafts. 74 SOLAS (20 Cons.) I/11(a) Action Code 50 ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 October 2023 Resolved
Containers, brackets, and similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating devices stowed in that location, the number of devices shall be also indicated. Found life jacket stowage's not marked with the number of devices stowed in their respective locations. 74 SOLAS (20 Cons.)III/20.10 Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The port anchor/mooring system was found with substantial wastage including missing bolts, wasted bolts&nuts, waster control arm and wasted protective covers. 74 SOLAS (20 Cons.)I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The starboard anchor/mooring system was found with substantial wastage including missing bolts, wasted bolts & nuts, wasted control arm, and wasted protective covers. 74 SOLAS (20 Cons.) I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Forward bilge suction valves including the #1 port and starboard ammo hold, #2 port and starboard ammo hold and bow thruster valves located on the anchor deck were found seized and unable to turn. 74 SOLAS (20 Cons.)I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The bos'n stores natural ventilation supply ventilation cover and bos'n stores battery room exhaust covers were found wasted, unable to close. 74 SOLAS (20 Cons.)I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The anchor handling gear hydraulic motor controller box mounting brackets are wasted, and the controller is being supported by its cables. 74 SOLAS (20 Cons.)I/11(a) Action Code 50 a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 April 2023 Resolved
Fire protection systems including structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Electric room cable penetration located in a class "A" boundary (top right) was not properly sealed. 74 SOLAS (20 Cons.) II-2/14.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 April 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 April 2023 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. The plan should include maintenance for fire mains, fire pumps and hydrants, including hoses. Fire station #97 hose burst during operational test of main fire pump. 74 SOLAS (20 Cons.) II-2/14.2.2
Action required: 10 - Deficiency Rectified
Resolved 4 April 2023
Resolution: Vessel replaced hose, had adequate spares
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 20 October 2022 Resolved
Each vessel must be manned IAW its COI. An AB was removed from the vessel due to an injury sustained during a lifeboat drill. Vessel must have the appropriate number of ABs per its COI prior to embarking on an international voyage.
Action required: 702 - Prior to embarking on international voyage
Resolved 23 October 2022
Resolution: Vessel captian provided a replacement AB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 June 2022 Resolved
In cargo ships of 5,000 gross tonnage and upwards there shall be a self-contained emergency source of power, located above the uppermost continuous deck and outside the machinery casings, to ensure its functioning in the event of fire or other casualty causing failure to the main electrical installation. The emergency diesel generator was unable to provide power to the emergency switchboard during the time of inspection. SOLAS 74 (Unamend.) II-1/26(a)(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2022
Resolution: New starter installed and EDG tested under load on automatic and manual mode to the satisfaction of the attending Class surveyor and MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2022 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks and safety controls. PSTP revision 3.1 approved September 6, 2018 does not accurately describe procedures to conduct required tests. MI’s conducted 16 test procedures, 02 could not be completed as written; EOT test and main engine low jacket water flow procedures. 46 CFR 61.40-6(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
10 - Safety of Navigation › N/A - No Subsystem › Rate-of-turn indicator
Issued 21 June 2022 Resolved
The main steering gear and rudder stock shall be capable of moving the rudder from 35° on either side to 35° on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed, and from 35° on either side to 30° on the other in not more than 28 seconds under the same conditions. During test of vessel’s steering, it was discovered that the rudder angle indicator was not capable to move 35 degrees stbd and stopped at 33 degrees starboard. Repair and prove operation of ship's main steering in wheelhouse and steering room is capable to place the rudder hard over left (35 deg.) in both modes using No. 1 and 2 steering pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 June 2022 Resolved
Fixed gas fire-extinguishing systems equivalent to those specified in paragraphs 2.2 to 2.4 shall be approved by the Administration based on the guidelines developed by the Organization. The vessel’s low-pressure CO2’s duplicate refrigerating plant is unable to automatically start up upon failure or stoppage of the unit in operation. Provide proof that the installation and operations of the vessel’s CO2 low pressure fixed firefighting system is in accordance with the applicable Class rules which is specified under the vessel’s CSSC certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 4 July 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 June 2022 Resolved
Cargo ships shall carry one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the Code of such aggregate capacity on each side of the ship as will accommodate the total number of persons on board. (LSA 4.4.2.2) - the number of persons having an average mass of 75 kg, or 82.5 kg (for a lifeboat intended for a cargo ship), all wearing lifejackets, that can be seated in a normal position without interfering with the means of propulsion or the operation of any of the lifeboat's equipment. Port and starboard lifeboats lower seating forward of helm found with cable interferences in way of seating arrangements. Provide USCG approved drawings for seating arrangements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Replace or repair the following to the satisfaction of the Class surveyor: a) Repair supply vent exhaust in upper flat in bow thruster room with visible crack to as original. b) Repair starboard side electrical pipe stuffing tube with wastage and holed located above the aft mooring station. c) Repair and preserve fuel vent pipe with excessive corrosion around manifold connection forward of ladder well on bow to as original. d) Remove corrosion on metal hangar support on MOGAS fuel line located at aft starboard mooring station for further inspection and repair. e) Make weather tight manhole access covers with missing bolts on the forward and aft bulkheads in starboard GCC compartment to prevent damage to high voltage electrical panels inside from wind/rain. f) Replace missing bolts on manhole cover located on upper most part of aft bulk located in Bosun’s store. Crew believes the manhole cover does not access a void or space due to its location. Verify in vessel’s records or drawings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2022 Resolved
All electrical apparatus shall be constructed and so installed that danger or injury in ordinary handling shall not exist. Repair overhead junction boxes with exposed wiring in fireman storage locker and hydraulic room in forward bosun locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Inspected and rectified to the satisfaction of USCG.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 June 2022 Resolved
Every radio installation shall be clearly marked with the call sign, the ship station identity, and other codes as applicable for the use of the radio installation. [name withheld] radios were with the vessel’s Call Sign and MMSI.
Action required: 705 - Other - as specified
Due 5 July 2022
Resolved 30 June 2022
Resolution: Call signs posted to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 21 June 2022 Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the Code shall be provided for every person on board the ship. During demonstration of donning immersion suits, a crew member was observed wearing their assigned immersion suits that was not of an appropriate size for his height/weight. Ensure all persons on board are provided with an appropriate size immersion suit.
Action required: 705 - Other - as specified
Due 5 July 2022
Resolved 1 July 2022
Resolution: Photo submitted to USCG MI showing crewmember with properly sized immersion suit.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 June 2022 Resolved
Photoluminescent exit sign with right arrow located in surge berthing points directly to the bulkhead lockers. Relocate photoluminescent exit sign with arrow point to the exit door or place additional photoluminescent arrows leading to the exit door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Photoluminescent arrow relocated to the satisfaction of the attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 June 2022 Resolved
Replace missing USCG approved whistles on lifejackets in gym and stencil vessel’s name on immersions suits, (17) x immersion suits in surge team berthing missing vessel’s name and (11) x immersions suits in the female berthing.
Action required: 705 - Other - as specified
Due 5 July 2022
Resolved 30 June 2022
Resolution: Verified to the satisfaction of the USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 June 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. It was self-reported that Lifeboat No. 3 charging plug is cracked and an order has been made to replace it. It was discovered by the attending Marine Inspector that Lifeboat Nos. 2 and 4 plugs are also cracked and Lifeboat No. 1 pin in plug is bent. Replace plugs for Lifeboat Nos. 1, 2 and 4 to the satisfaction of Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2022 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Repair door frame in cargo pump room to prevent the passage of smoke and fire into trunk access also an emergency egress to the satisfaction of the attending Class surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2022
Resolved 5 July 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2022 Resolved
Repair holed and wasted supply air/exhaust ventilation ducting in cargo pump room access trunk to as original to the satisfaction of the attending Class surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 21 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Fuel cargo TLIs in cargo pump room were inspected with a tag labeled not working since YR2020. Vessel’s approved cargo transfer procedures requires use of cargo TLIs during cargo fuel operations. Vessel to repair cargo TLIs and prove operation to the attending Class surveyor. Prior to cargo operations, vessel to provide alternative procedures for sounding fuel cargo tanks in accordance with vessel’s SMS and have reflected in vessel’s cargo fuel transfer procedures to the satisfaction of the Class surveyor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 June 2022 Resolved
Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Prove operation of general alarms in way of vertical members with written numbers 116 and 127 located on the starboard side in No. 1 cargo hold.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 21 June 2022 Resolved
Replace missing sign for to lifeboats in forward passage stairwell on 01 deck with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Signs replaced and posted to the satisfaction of the attending USCG MI.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 21 June 2022 Resolved
Repaint faded “To All Lifeboat Station” metal placards on the bridge port and starboard side bridge aft exterior bulkhead to as original. Recommend additional lifeboat station sign painted with an arrow on the aft most exterior bulkhead in way of the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Repainted to the satisfaction of the attending USCG MI.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 21 June 2022 Resolved
Any part of such information may be provided in the form of audio-visual aids in lieu of the manual: muster at the assigned station. Per vessel’s muster procedures for abandon ship, vessel crew muster at the aft main deck for accountability before proceeding to assigned lifeboats. USCG Marine Inspectors discovered multiple muster station signs located inside the house and on aft exterior bulkhead with arrows directing persons to the port and starboard lifeboats as the muster stations. Update muster station signs to guide all persons to the designated muster station that is located on the aft main deck as per vessel’s approved emergency procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Procedures acceptable to the satisfaction of the USCG MI. Per vessel's captain, all crew and mission personnel are given an orientation of where to muster in an emergency upon reporting aboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Replace sun damaged and weathered ring buoy lines with float light attached with new and USCG approved lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 30 June 2022
Resolution: Re-inspected to the satisfaction of the attending USCG MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2022 Resolved
Training manual shall be provided in each crew mess room and recreation room or in each crew cabin. Provide a training manual in the officers and unlicensed crewmembers in the recreation room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 June 2022 Resolved
Update Training Manual to reflect the approved life savings and arrangement plan: a. Life jackets and immersion suits stowed in the engine room (not included) b. Life raft/Lifeboat diagram: i. Life raft #9 for 25 persons (not 20) ii. Life raft #4 for 25 persons (not 20) iii. Diagram does not reflect the port 73 manned Lifeboat as a rescue boat c. Equipment Lists for the lifeboats: total rations and water are for 99 persons. Update to reflect each 101 and 73 person on P/S lifeboats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 10 August 2022
Resolution: Cleared to the satisfaction of Class. Class report uploaded to Documents.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 June 2022 Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. Prior to departure, fire drill must be completed again to the satisfaction of the attending Marine Inspectors.
Action required: 10 - Deficiency Rectified
Due 22 June 2022
Resolved 22 June 2022
Resolution: Fire drill completed to the satisfaction of the attending USCG MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 June 2022 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensure under various emergency conditions. Prove operation of red lights in overhead near each exit in surge berthing.
Action required: 10 - Deficiency Rectified
Due 21 June 2022
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 August 2021 Resolved
74 SOLAS (2020) Chapter II-2, Part D, Reg. 13/2.1: Unless expressly provided otherwise in this regulation, at least two widely separated and ready means of escape shall be provided from all spaces or groups of spaces. Remove all equipment/gear blocking secondary means of escape from the inside of the KRB/MCMC workshop on 63 Level deck.
Action required: 10 - Deficiency Rectified
Due 13 August 2021
Resolved 9 August 2021
Resolution: Photo sent from vessel's Capt showing with means of escape unblocked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 June 2019 Resolved
46 CFR 92.01-5: Cargo pump room exterior ventilation cover on the main deck forward of house is wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 June 2019 Resolved
SOLAS 74 II-1/29.a.i: The auxiliary steering gear shall be of adequate strength and sufficient to steer the ship at navigable speed and capable of being brought speedily into action in an emergency. Steering gear No. 2 is unable to be brought into immediate service due to electrical issues. Make repairs to the No. 2 steering gear prior to vessel departure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 June 2019 Resolved
46 CFR 56.60-25(b): Nonmetallic flexible hoses must be in accordance with SAE J1942 . Emergency diesel generator nonmetallic lube oil turbo supply hoses do not currently meet SAE J1942 standards, install approved hoses or install approved SAE J1942 fire sleeves over existing hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2019 Resolved
46 CFR 111.01-2(2): Electrical installations on vessels must ensure: protection of passengers, crew, other persons, and the vessel from electrical hazards. Properly lock out/tag out and secure electrical panel in crew laundry room with sign that says "Out of Order" to prevent accidental use and in accordance with vessel's SMS shipboard procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 June 2019 Resolved
SOLAS 74 III/20.2 and 46 CFR 199.190(a): Operational readiness-Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Repair lifeboat number 4, rudder with wood rot to as original in accordance with OEM specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 June 2019 Resolved
SOLAS III/20.2, 46 CFR 199.190(a): Repair broken rudder on lifeboat no. 1, to as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 June 2019 Resolved
SOLAS III/20.2, 46 CFR 199.190(a): Replace rudder gudgeon with wastage on lifeboat number 3, to as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 June 2019 Resolved
SOLAS III/20.2, 46 CFR 199.190(a): Replace propeller with wastage on lifeboat number 4, to as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2019 Resolved
SOLAS (74) III/20.2, 46 CFR 199.190(a): Rqst to have more than 60 persons embark vessel while in port of Guam at Buoy 702, in support of main engine overhaul repairs and other missions. Vsl is prohibited from departing [name withheld] with more than 60 persons onboard.
Action required: 705 - Other - as specified
Resolved 19 June 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 3 October 2018 Resolved
46CFR113.25-12(a)(c): General alarms found not working at the following locations: 63 Level, A-deck ladder well and sgure mess. Repair and retest to the satisfaction of attenidng MI.
Action required: 705 - Other - as specified
Due 17 October 2018
Resolved 9 October 2018
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 March 2018 Resolved
07103-Emergency escape from main engineroom to accomodation space is not protected by A-60 insulations and does not meet the minimum size required for Means of Escape. Correct to the satisfaction of the attending Marine Inspector or ABS surveyor by 31MAY2018. (705 A/C)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 5 April 2018
Resolution: Recieved further clarification on emergency escape trunk as per plans and definition under SOLAS. USCG concurs and removed CG-835.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 March 2018 Resolved
03103-Two handrails located on port-side forward main-deck are wasted. Repair or replace to the satisfaction of the attending Marine Inspector or ABS surveyor by 30June2018. (705 A/C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to reflet witnessing of repairs by surveyor [name withheld]
Stability › Weathertight Integrity › General
Issued 27 March 2018 Resolved
03104-Weathertight hatch located forward of the cargo holds to the forward Bosun Stores and access to Bowthruster Space is holed. Correct to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of repair by surveyor [name withheld]
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 March 2018 Resolved
07115-Fire Dampers throughout vessel (Fan Room 03 port side, Fan Room main-deck port side, two in Fan Room main-deck starboard side) are frozen, wasted, and inoperable. Correct to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of deficiency by surveyor [name withheld]
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 27 March 2018 Resolved
07115-Fire Dampers position throughout vessel are labeled improperly. Correct to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of deficiency by surveyor [name withheld]
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 March 2018 Resolved
07101-Cableways through structural fire protection bulkheads (Fan Room main-deck starboard side and 63 level auto tool room) were modified to allow more cables to penetrate the bulkhead without returning the cableway to the original condition. Correct to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of repair by surveyor [name withheld]
Stability › Weathertight Integrity › General
Issued 27 March 2018 Resolved
03199-Gooseneck vent forward port ACON is wasted. Determine is tank contains hazardous or non-hazardous material. Repair to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of repair by surveyor [name withheld]
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2018 Resolved
09108-Light fixture in the A-deck storage locker missing guard, exposing bulb. Repair to the satisfaction of the attending Marine Inspector or ABS Marine Surveyor by 30JUN2018. (705 A/C)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 2 May 2018
Resolution: Uploaded ABS report to indicate witnessing of deficiency by surveyor [name withheld]

Casualty record · 9

5 November 1997Major Marine Casualty · role: Involved in a Marine Casualty · activity 100207
9 January 2002Routine · role: Involved in a Marine Casualty · activity 1774673
10 April 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6697671
15 November 2019Routine · role: Involved in a Marine Casualty · activity 6856576
19 September 2020Routine · role: Involved in a Marine Casualty · activity 7089589
19 September 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 6 injured · activity 7109098
17 December 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7113184
15 August 2021Routine · role: Involved in a Marine Casualty · 1 injured · activity 7294895
15 August 2021Routine · role: Involved in a Marine Casualty · activity 7294899
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

2ND LT. JOHN P. BOBO (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record