This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1619 - Regulatory (Subpart C or D), Gross Ton
1619 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-24585
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
TBSIP self reported Def. Make permenant repairs to fracture in stbd bow at the top of the corner wrapper 8"x 1/8".
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 October 2012
Resolved 6 September 2012
Resolution: Satisfactorily air tested and approved by [name withheld].
Construction/Loadline › Hull › Hull Plating
Issued 5 July 2012Resolved
TBSIP Self Reported Deficiency. Make permenant repairs to 8" X 1/8" fracture in stbd bow at the top of the corner wrapper.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2012
Resolved 13 August 2012
Resolution: Permenant repairs were made to 8" X 1/8" fracture. Witnessed testing using soap/air mixture. repairs satisfactory, no further action required.
Construction/Loadline › Hull › Side Shell
Issued 13 March 2012Resolved
D8 TBSIP SELF REPORTED DEFICIENCY. Make permanent repairs to (1) 12"x1/4" fracture on the stern side shell.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 April 2012
Resolved 13 March 2012
Resolution: Attended vessel and witnessed satisfactory repairs to the stern side shell.
Construction/Loadline › Hull › Hull Plating
Issued 13 March 2012Resolved
12" X 1/4" fracture on on lower corner port stern.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 13 March 2012
Resolution: 1- 4'' X 3'' X 3/4"and 1- 6'' X 6" X 3'' X 3/8" plate was replaced on the lower port corner and side shell
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2008Resolved
Make permanent repairs to the port bow corner wrapper.
Due 6 August 2008
Resolved 18 July 2008
Resolution: C/R 3/4" x 4''6" x 3''3" port corner and 1" x 2''6" x 2'' deck plate. Air test sat.