Records from 2003 to 2025. Most recent: inspection, 18 June 2025.
Documentation record
Registered dimensions (L × B × D)38.9 ft × 14.8 ft × 7.0 ft
Registered tonnagegross 24 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALEHI MARINE · LACOMBE, LA, UNITED STATES · built 1985
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT LAVACA, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
18 June 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8166042
10 February 2025
Administrative Inspection · Deficiency Check · Uninspected Other
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8034110
19 November 2024
Excursion Permit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8037030
8 July 2024
Administrative Inspection · Exemption
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7954486
8 April 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7899106
10 October 2023
Administrative Inspection · Exemption
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7806304
9 August 2023
Exemption
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7764095
12 July 2023
Exemption
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7741059
27 October 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7584808
23 August 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7541644
24 July 2020
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 7016758
6 December 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6872951
2 October 2019
Administrative Inspection · Uninspected Other
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6826787
2 October 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6826884
25 September 2019
Type not recorded
No type recorded · Station Port OConnor · USCG Heartland District (CGD-H) · Activity 6821268
26 August 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6824497
15 November 2018
In-Service Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6581342
17 April 2018
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6410050
12 July 2012
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4376620
26 January 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3933947
24 January 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3933569
23 May 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3501785
16 December 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2552299
9 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2191436
17 August 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2168829
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983449
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2025
Resolved
You must have a fire detection system installed on your vessel to detect engine-room fires. Marine Inspector noted the damaged and inoperable heat detector in the engine-room. The Fire detection panel on bridge was inoperable and without power. Third party service required to repair damaged heat detector and service fire detection system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Tech report received.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 February 2025
Resolved
The portable fire pump fire pump must be self-priming and power driven. When conducting test on portable fire pump, water had to be added to prime pump before taking suction.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Fire pump proved self-primimg.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025
Resolved
The following items are considered unsafe or pose a threat to the marine environment:
(a) Excessive oil in the bilge.
(b) Excessive debris in the bilge.
(c) Automatic bilge pump from the engine room with uninhibited direct overboard discharge.
d) Exposed electrical wiring in the bilge water.
e) Wastage in weather deck above forepeak.
f) Wastage on engine room access ladder.
g) Leak in fire hose.
h) Lazarette sea chest pipe fitted with flexible hose lacking proper clamps.
i) Bilge alarms inoperable.
j) Seal overboard discharge which now has free communication with the sea after removal of unauthorized automatic engine room bilge pump.
k) Engine room generator not secured to deck.
l) Engine salt water cooling lines not mounted; excessive length of flexible hoses are strewn about the engine room deck plating.
m) Foot valve required to make emergency dewatering pump self priming.
n) Exhaust leak on port engine manifold gasket.
o) Excessive dead-end electrical wiring in engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Work list completed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 October 2019
Resolved
Excessive corrosion and holes in metal on the starboard and port sides of the transom
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 6 December 2019
Resolution: Attended vsl and confirmed all Ultrasonic Testing was complete and necassary metal was cropped and renewed as necassary, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2019
Resolved
The is no operational fire detection system on board. Repair, replace, or install a fire detection system on board in accordance with 46 CFR 27.203
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 October 2019
Resolved
There is no fixed or portable fire pump on board vessel. Either install a fixed fire pump or place a portable fire pump on board vessel that meets the requirements of 46 CFR 27.301. Also ensure that a fire hose and vary nozzle is provided in accordance with 46 CFR 27.301.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019
Resolved
Excess water was discovered in forward void above 24 inches, approximately 6 to 8 inches in the aft void, and approximately 8 to 12 inches in the engine compartment. Remove water and prevent ingress.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2019
Resolved
Multiple improper splicing of wires throughout engine room. Wiring needs to be properly terminated in junction boxes to prevent shock and fire hazards
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2019
Resolved
Port engine exhaust is missing was missing insulation and the starboard engine exhaust had multiple exhaust leaks. Install insulation and make adequate repairs to ensure the safety of the crew by preventing risk of burns and carbon monoxide poisoning in accordance with 33 CFR 160.111
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2019
Resolved
Bilge pumps and bilge alarms are inoperable. Must ensure proper operation of the vessels bilge pumps and alarms.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 September 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 October 2019
Resolved 1 September 2022
Resolution: Vessel was issued a SWE by Sec Hou/Gal
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2018
Resolved
CERTIFICATES -(COD) CERTIFICATE OF DOCUMENTATION
ANY VESSEL OF AT LEAST FIVE NET TONS WHICH ENGAGES IN THE FISHERIES ON THE NAVIGABLE WATERS OF THE UNITED STATES OR IN THE EXCLUSIVE ECONOMIC ZONE OR COASTWISE TRADE, UNLESS EXEMPT UNDER 67.9(c) MUST HAVE A CERTIFICATE OF DOCUMENTATION BEARING A VALID ENDORSEMENT APPROPRIATE FOR THE ACTIVITY IN WHICH ENGAGED. VESSEL WAS FOUND TO BE ACTIVELY TOWING A DREDGE BARGE IN CORPUS CHRISTI BAY WITHOUT A VALID COD. VESSEL MUST CEASE OPERATIONS AND RETURN TO BERTH UNTIL A VALID COD IS PROVIDED TO THE SAISFACTION OF THE COAST GUARD MARINE INSPECTOR.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2018
Resolved 23 January 2019
Resolution: Vessel obtained valid COD on 3 Dec 18.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 November 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2018
Resolved 23 January 2019
Resolution: Due to Work Site Exclusion (WSE) being approved, vessel is not required a licensed mariner while working within the WSE.