FIRST STATE is a 1985 towing vessel. The Coast Guard has recorded 26 inspections since 2003, most recently in June 2025, along with 13 deficiencies, 3 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2011 and 2018.
Records from 2003 to 2025. Most recent: inspection, 18 June 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)38.9 ft × 14.8 ft × 7.0 ft
Registered tonnagegross 24 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALEHI MARINE · LACOMBE, LA, UNITED STATES · built 1985
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT LAVACA, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton 16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2025Resolved
You must have a fire detection system installed on your vessel to detect engine-room fires. Marine Inspector noted the damaged and inoperable heat detector in the engine-room. The Fire detection panel on bridge was inoperable and without power. Third party service required to repair damaged heat detector and service fire detection system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Tech report received.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 February 2025Resolved
The portable fire pump fire pump must be self-priming and power driven. When conducting test on portable fire pump, water had to be added to prime pump before taking suction.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Fire pump proved self-primimg.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025Resolved
The following items are considered unsafe or pose a threat to the marine environment:
(a) Excessive oil in the bilge.
(b) Excessive debris in the bilge.
(c) Automatic bilge pump from the engine room with uninhibited direct overboard discharge.
d) Exposed electrical wiring in the bilge water.
e) Wastage in weather deck above forepeak.
f) Wastage on engine room access ladder.
g) Leak in fire hose.
h) Lazarette sea chest pipe fitted with flexible hose lacking proper clamps.
i) Bilge alarms inoperable.
j) Seal overboard discharge which now has free communication with the sea after removal of unauthorized automatic engine room bilge pump.
k) Engine room generator not secured to deck.
l) Engine salt water cooling lines not mounted; excessive length of flexible hoses are strewn about the engine room deck plating.
m) Foot valve required to make emergency dewatering pump self priming.
n) Exhaust leak on port engine manifold gasket.
o) Excessive dead-end electrical wiring in engine room.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 February 2025
Resolution: Work list completed.
Excessive corrosion and holes in metal on the starboard and port sides of the transom
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 6 December 2019
Resolution: Attended vsl and confirmed all Ultrasonic Testing was complete and necassary metal was cropped and renewed as necassary, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2019Resolved
The is no operational fire detection system on board. Repair, replace, or install a fire detection system on board in accordance with 46 CFR 27.203
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 October 2019Resolved
There is no fixed or portable fire pump on board vessel. Either install a fixed fire pump or place a portable fire pump on board vessel that meets the requirements of 46 CFR 27.301. Also ensure that a fire hose and vary nozzle is provided in accordance with 46 CFR 27.301.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019Resolved
Excess water was discovered in forward void above 24 inches, approximately 6 to 8 inches in the aft void, and approximately 8 to 12 inches in the engine compartment. Remove water and prevent ingress.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2019Resolved
Multiple improper splicing of wires throughout engine room. Wiring needs to be properly terminated in junction boxes to prevent shock and fire hazards
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2019Resolved
Port engine exhaust is missing was missing insulation and the starboard engine exhaust had multiple exhaust leaks. Install insulation and make adequate repairs to ensure the safety of the crew by preventing risk of burns and carbon monoxide poisoning in accordance with 33 CFR 160.111
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2019Resolved
Bilge pumps and bilge alarms are inoperable. Must ensure proper operation of the vessels bilge pumps and alarms.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2019
Resolved 21 February 2020
Resolution: MSD Victoria attended vessel with vessel rep. to complete exam to remove COTP Order # 001-20. During the exam, MSD Personnel determined that the Fire Detection system, removed wires, portable fire pump, exhaust insulation, and water removed from voids was
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 September 2019Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 October 2019
Resolved 1 September 2022
Resolution: Vessel was issued a SWE by Sec Hou/Gal
CERTIFICATES -(COD) CERTIFICATE OF DOCUMENTATION
ANY VESSEL OF AT LEAST FIVE NET TONS WHICH ENGAGES IN THE FISHERIES ON THE NAVIGABLE WATERS OF THE UNITED STATES OR IN THE EXCLUSIVE ECONOMIC ZONE OR COASTWISE TRADE, UNLESS EXEMPT UNDER 67.9(c) MUST HAVE A CERTIFICATE OF DOCUMENTATION BEARING A VALID ENDORSEMENT APPROPRIATE FOR THE ACTIVITY IN WHICH ENGAGED. VESSEL WAS FOUND TO BE ACTIVELY TOWING A DREDGE BARGE IN CORPUS CHRISTI BAY WITHOUT A VALID COD. VESSEL MUST CEASE OPERATIONS AND RETURN TO BERTH UNTIL A VALID COD IS PROVIDED TO THE SAISFACTION OF THE COAST GUARD MARINE INSPECTOR.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2018
Resolved 23 January 2019
Resolution: Vessel obtained valid COD on 3 Dec 18.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 November 2018Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 3 December 2018
Resolved 23 January 2019
Resolution: Due to Work Site Exclusion (WSE) being approved, vessel is not required a licensed mariner while working within the WSE.
24 January 2011Routine · role: Involved in a Marine Casualty · activity 3933569
17 April 2018Major Marine Casualty · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · activity 6410050
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.