Records from 1985 to 2026. Most recent: inspection, 7 August 2026.
Inspection history · 92
7 August 2026
In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8412228
13 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8345510
26 June 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8167257
16 November 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8034700
9 April 2024
COI Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7892358
15 February 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7859072
14 December 2023
Deficiency Check · Construction Oversight · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7839090
12 October 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7807454
28 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7725374
30 May 2023
In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7700402
7 April 2022
Periodic Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7426330
13 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7173389
12 June 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6966871
14 January 2019
COI Inspection · Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6609814
24 July 2018
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6489519
9 May 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6142466
4 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6117536
6 March 2017
MTSA/ISPS Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6090113
13 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6087498
23 February 2016
MTSA Verification · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5820365
11 March 2014
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4814151
14 June 2012
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4343749
17 January 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4226172
7 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4203415
8 February 2011
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3941411
3 December 2009
COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3643853
12 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3639671
8 January 2009
Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3390617
15 April 2008
Periodic Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3213663
10 April 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2906044
11 April 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2622101
19 January 2005
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2276975
13 December 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2258421
3 December 2004
MTSA Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2254888
23 November 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2246693
15 September 2004
Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2197172
8 April 2004
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2039817
6 January 2004
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1979666
11 August 2003
Drydock Extension
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1867462
29 April 2003
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1782496
8 May 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1614166
2 April 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1445803
10 February 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 814170
16 November 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 809166
2 March 1999
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1459490
6 November 1998
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1368912
26 May 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 792426
30 March 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1404548
3 March 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1408060
13 November 1997
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 785894
5 November 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1453421
19 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779248
18 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 28148
5 February 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1453333
31 December 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 146071
28 October 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 31780
10 September 1996
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1260039
1 August 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1087903
13 February 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 877597
9 February 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458280
20 March 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1140454
9 February 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 840302
9 February 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163777
12 November 1993
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1158571
15 July 1993
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 846776
10 February 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1143817
5 June 1992
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259964
21 February 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1015036
11 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1313979
22 April 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 920626
21 February 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1227834
7 April 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1218470
21 February 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1232607
29 August 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1196499
28 April 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886648
2 March 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1208000
17 January 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886478
30 November 1988
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894423
13 July 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 899155
3 March 1988
Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 889573
3 November 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1023307
30 October 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1018901
30 June 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009507
24 April 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1007164
19 March 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1325677
12 July 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1303811
26 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1303225
15 April 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 999368
6 March 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1299426
9 May 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 984274
25 April 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1288035
24 April 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1289092
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2026
Resolved
Nonconducting mats are required on the deck in front of each switchboard. Switchboards in generator space do not have nonconducting mats. Install mats in front of each switchboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2026
Resolution: mats were installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 April 2026
Resolved
Pilothouse bridge has numerous open wires under the operating console. Terminate or cap wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2026
Resolution: All wires have been terminated and capped off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 November 2024
Resolved
Each vessel that relies on electricity to power to power the following loads must be arranged so that the loads can be energized from two sources of electricity:
1. The vital systems...
2. Interior lighting except for decorative lights;
3. Communication systems including a PA system...;
4. Navigation equipment and lights.
The vessel's port generator is exceeding 60HZ whenever placed under load.
Prove proper operation of the port generator prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2024
Resolved 20 November 2024
Resolution: Provided proper operation of the port generator, with normal operations, then with a Full load.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 April 2024
Resolved
Clean port generator, identify any leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 30 April 2024
Resolution: Rebuilt fuel oil pump installed and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 April 2024
Resolved
Illustrations and instructions in English, and any other appropriate language as determined by the OCMI, must be posted in each passenger cabin and in spaces occupied by persons other than crew, and must be conspicuously displayed at each muster station. The illustrations and instructions must include information on - The method of donning lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 16 April 2024
Resolution: The illustrations and instructions have been posted on - The method of donning lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2023
Resolved
46CFR120.200
Outlet connection was missing blank cover and an exposed low volt communication wire end exposed were both found in the snack shack directly under the navigation bridge on the 3ed deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2023
Resolved 27 July 2023
Resolution: Replaced cover
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2022
Resolved
Vessel is required to have a reachrod on the weatherdeck capable of operating the screw-down valve on the bilge piping system. Currently, the reachrod is in-operable. Repair/replace reachrod.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 22 April 2022
Resolution: The reachrod is operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 April 2022
Resolved
Type I PFDs must have at least 31 square inches of retroreflective material on front and back. Multiple PFDs throughout the vessel had degraded retro or an inadequate amount of retro material. Replace/repair to servicable conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 22 April 2022
Resolution: Replaced retro of PFD's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2019
Resolved
Remove pressure vessel inspection plugs to facilitate 5 year internal inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2019
Resolved 4 June 2019
Resolution: Pressure guage, relief valve and plug removed to see internals, all satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 July 2018
Resolved
Raw water pump for air conditioning heat exchanger was leaking excessively resulting in approximately 3" of water in the starboard engine room bilge. Valve to sea suction had to be secured to stop the leak. Vessel cannot operate with sea suction to heat exchanger pump open until pump is repaired and leak is eliminated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2018
Resolved 27 July 2018
Resolution: MI verified vessel leak was properly repaired
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 27 July 2018
Resolved
Excess equipment, tools, gear, trash, and parts are scattered throughout the engineering spaces. Items need to be properly stowed/secured for operations during all possible river conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2018
Resolved 6 August 2018
Resolution: All gear adrift in eng room secured.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 July 2018
Resolved
Vessel fire pump was seized and not opperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2018
Resolution: Fire pump was replaced and tested satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 July 2018
Resolved
Two batteries were found stored in the bilge of the engine room and sewage room unsecured or protected from exposure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 27 July 2018
Resolution: Batteries were removed from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2018
Resolved
Power strip is being utilized as permanent wiring solution for oven, fan, and refrigerator in sewage/storage room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2018
Resolution: Power strip was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2018
Resolved
Three life jackets were found in wasted condition.
Action required: 10 - Deficiency Rectified
Due 24 July 2018
Resolved 24 July 2018
Resolution: Three new life jackets were brought on board.
Fire Fighting › Fire Pumps › Pressure
Issued 14 July 2017
Resolved
Prove proper operation of fire pump without having to bleed air from system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Vent line installed on seachest piping, fire pump tested satisfactory several times without bleeding air from system.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 July 2017
Resolved
Conduct required training; maoverboard, fire, abandon ship, security drills. Ensure all training and drills properly logged.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Training and drills conducted and logged.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 14 July 2017
Resolved
Install additional extinguishers in all service areas and generator room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Additional extinguishers installed.
Fire Fighting › Nozzles › Type
Issued 27 June 2017
Resolved
Replace fire hose nozzle on 2nd deck that needs an adapter with a nozzle that is able to be used on all fire hoses without an adapter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: New nozzle installed that matches and fits all hoses onboard.
Fire Fighting › Fire Hydrants › Material
Issued 27 June 2017
Resolved
Install missing spanner at fire hydrant on 3rd deck, ensure 2nd deck securely fastened.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Spanners installed and properly fastened.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 June 2017
Resolved
Ensure 575 adult & 58 child properly maintained life jackets are on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: All lifejackets inspected repaired or replaced and properly stowed and labeled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 June 2017
Resolved
Repair aft portion of rail port & stbd 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Both sections repaired.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 June 2017
Resolved
Repair/ replace/ prove proper operation of emergency lighting above forward port door on 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: New light installed and tested satisfactory.
Construction/Loadline › Structures › Door
Issued 27 June 2017
Resolved
Replace broken door 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: New door installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 June 2017
Resolved
Repair/ replace/ prove proper operation of 2 broken lights 3rd deck under bridge wings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2017
Resolution: Light fixtures replaced, properly mounted and tested satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 2 March 2016
Resolved
Properly replace 02 holed fire hoses.
Due 16 March 2016
Resolved 16 March 2016
Resolution: Replaced.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 23 February 2016
Resolved
Properly install missing fire clips for 02 deck stbd side two windows.
Due 16 March 2016
Resolved 16 March 2016
Resolution: Clips were properly installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 March 2014
Resolved
Found portable FFE with gauge in the red. Required to replace.
Action required: 705 - Other - as specified
Resolved 11 March 2014
Resolution: Vessel rep replaced with new spare FFE.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 11 March 2014
Resolved
Three orange smoke flares expired. Replace with new.
Action required: 705 - Other - as specified
Resolved 11 March 2014
Resolution: Vessel rep provided three new orange smoke flares.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 15 April 2008
Resolved
Reinstall all missing window retaining clips.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 15 May 2008
Resolution: Received, work order and billing for fabrication and installation of retaining clips.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 April 2008
Resolved
Vessel is limited to 476 Passengers and 25 crewmembers untill 124 adult lifejackets are renewed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 15 May 2008
Resolution: Received order and packing slip for 150 type I lifejackets.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 April 2007
Resolved
Electrical panel "P3" door upper hinge was broken.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 19 April 2007
Resolution: Hinge was installed and door operates properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 April 2007
Resolved
Inboard A/C switch box has cable run through open front panel. Cable needs to be properly run so box will close as designed.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 19 April 2007
Resolution: The cable was properly routed through the box and connected as designed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 April 2003
Resolved
27- PFDs needed retro tape renewed. LEGACY COMPONENT DESC: Marking
Due 29 April 2003
Resolved 29 April 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 May 2002
Resolved
Condition: Unknown
Due 8 May 2002
Resolved 8 May 2002
Resolution: Placed 2 new adult PFDs onboard.
pfds onboard.
Fire Fighting
Issued 2 April 2001
Resolved
Complete hydrostatic servicing on portable fire extinguisher on 02 deck snack bar and Pilot house.
Condition: Unknown
Due 2 April 2001
Resolved 27 April 2001
Lifesaving
Issued 3 March 1998
Resolved
Replace one ring bouy required by 46 CFR 117.70.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
Provide mounting bracket for B-II portable fire extinguisher located at pilot house.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Documentation
Issued 3 March 1998
Resolved
Provide waste management plan for removal of all garbage.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
Provide servicing for all fire fighting appliances as required by 46 CFR 118.500.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
Replace reflective tape on PFD's as needed as required by 46 CFR 122.604.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Accommodation/Occupational Safety
Issued 3 March 1998
Resolved
Provide inspection of pressure vessel and safety relief valve located in storage compt as required by 46 CFR 61.10.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
Provide first aid kit as required by 46 CFR 121.710.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
Provide an emergency broadcast placard as required by 46 CFR 121.506.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 19 October 1997
Resolved
DUE TO VSL GROUNDING OFF LIDO KEY, FL ON 18OCT97 WHILE TRANSITTING ENROUTE NEW H/PORT, CONDUCT U/W BODY SURVEY OR DRYDOCK EXAM PRIOR TO CARRIAGE OF PASSENGERS AND AT DISCRETION OF COGNIZANT OCMI.
Condition: Unknown
Due 19 October 1997
Resolved 19 October 1997
Electrical
Issued 5 February 1997
Resolved
PROPERLY SECURE WIRING TO PORT A/C CIRC PUMP AND UTILIZE WIRE CLAMPS _x001C_
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Electrical
Issued 5 February 1997
Resolved
INSTALL PROPER GLOBES ON THIRD RESTROOM LIGHT FIXTURES
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Accommodation/Occupational Safety
Issued 5 February 1997
Resolved
CLEAN AREA IWO 2ND DECK BAR COOLER
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Engineering
Issued 5 February 1997
Resolved
INSTALL PROPER SIZED BOLTS ON THE PORT SHAFT COUPLING.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Electrical
Issued 9 February 1996
Resolved
PROPERLY TERMINATE LIVE DEAD END WIRE IN JUNCTION BOX OVER PORT GENERATOR AND INSTALL COVER ON JUNCTION BOX.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1996
Resolved
INSTALL BLANKS IN ELECTRICAL PANEL OPENINGS.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Lifesaving
Issued 9 February 1996
Resolved
PROVIDE (12) PROPER PYROTECHNIC DISTRESS SIGNALS AS PER 46 CFR 180.35-1, 5.VESSEL; LIMITED TO TRIPS OF NOT MORE THAN (30) MINUTES DURATION UNTIL CORRECTED.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996
Resolved
INSTALL DRAIN LINE FROM HOT WATER HEATER RELIEF VALVE DOWN TO DECK TO AVOIDPOTENTIAL SCALDING HAZARD.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996
Resolved
SECURE CO2 FIRE EXTINGUISHERS AND COMPRESSED GAS CYLINDERS IN HOLD DECK.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996
Resolved
POST MAXIMUM PASSENGER CAPACITY OF SECOND AND THIRD DECK LISTED IN STABILITY LETTER AT THE ENTRANCES TO THE SECOND DECK AS PER 46 CFR 185.30-3(e).
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Navigation
Issued 9 February 1996
Resolved
INSTALL AND PROVE PROPER OPERATION OF ANCHOR LIGHT AS PER USCG NAVIGATION RULES, INLAND, RULE 30,(b).
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996
Resolved
SECURE ACCUMULATOR IN WATER SUPPLY LINE.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Construction/Loadline
Issued 9 February 1996
Resolved
MARK AFT WATERTIGHT DOOR ON BOTH SIDES IN AT LEAST ONE INCH LETTERS: WATERTIGHT DOOR - KEEP CLOSED EXCEPT DURING TRANSIT.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Construction/Loadline
Issued 9 February 1996
Resolved
PROVE PROPER OPERATION OF EACH "WATERTIGHT DOOR AJAR" LIGHTS IN THE PILOTHOUSE.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Fire Fighting
Issued 9 February 1996
Resolved
PROVE PROPER OPERATION OF HAND FIRE PUMP AS PER 46 CFR 181.10-5(a)._x001C_ PASSENGER OPERATIONS PROHIBITED UNTIL CORRECTED.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Documentation
Issued 9 February 1996
Resolved
PREPARE LOCAL CONTINGENCY PLAN AS PER MSO ST LOUIS INSPECTION DEPARTMENT POLICY FILE MEMO 1-94.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Construction/Loadline
Issued 9 February 1996
Resolved
INSTALL PROPER STRAINER ON FOREPEAK BILGE LINE AS PER 46 CFR 56.50-50(g).
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Fire Fighting
Issued 9 February 1996
Resolved
PROVE ANNUAL SERVICING PERFORMED ON ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO CONDUCTING PASSENGER OPERATIONS.
Condition: Unknown
Due 13 February 1996
Resolved 13 February 1996
Documentation
Issued 9 February 1996
Resolved
PROVE PARTICIPATION IN PRE-EMPLOYMENT AND RANDOM DRUG/CHEMICAL TESTING AS PER 46 CFR 16, SUBPART B.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1995
Resolved
REPLACE ALL WIRE NUTS WITH PERMANENT CONNECTORS ON WIRING LOCATED BELOW PILOT HOUSE CONSOLE.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Electrical
Issued 9 February 1995
Resolved
REPLACE "TEMPORARY" EXTENSION CORD TO COLLIOPY UNIT ABOVE 3RD DECK WITH WIRE OF PERMANENT APPROVED TYPE.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Accommodation/Occupational Safety
Issued 9 February 1995
Resolved
REPAIR THIRD DECK STBD SIDE TOILET.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Accommodation/Occupational Safety
Issued 9 February 1995
Resolved
INSTALL 2ND SET OF DEAD BOLTS ON MAIN DECK DOUBLE DOORS.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Lifesaving
Issued 9 February 1995
Resolved
INSTALL WARNING/INSTRUCTION ON MAIN DECK DOUBLE DOORS TO KEEP DOORS LOCKED WHILE UNDERWAY.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Accommodation/Occupational Safety
Issued 9 February 1995
Resolved
INSTALL FLAME SCREEN ON MSD VENTS.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Accommodation/Occupational Safety
Issued 9 February 1995
Resolved
REPLACE FADED PFD AND EMERGENCY CHECK-OFF SHEET ON THIRD DECK.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Electrical
Issued 9 February 1994
Resolved
BALANCE ELECTRICAL LOAD BETWEEN PHASES, 1ST AND 3RD LEGS ARE LOW, 2ND IS HI
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Lifesaving
Issued 9 February 1994
Resolved
IDENTIFY TYPE AND NUMBER OF PFD'S STORED 3RD DECK OVERHEAD.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Electrical
Issued 9 February 1994
Resolved
LABLE ALL MOTOR CONTROLLERS THRU-OUT ENGINEERING SPACES.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Construction/Loadline
Issued 9 February 1994
Resolved
POST DIAGRAM OF BILGE SYSTEM ABOVE MANIFOLD STATION.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Fire Fighting
Issued 9 February 1994
Resolved
FREE UP FROZEN NOZZLE, 3RD DECK FIRE STATION.
Condition: Unknown
Due 13 February 1994
Resolved 17 February 1994
Electrical
Issued 9 February 1994
Resolved
TROUBLE SHOOT/CORRECT NON-OPERATING "E" LIGHT 1ST DECK BAR.
Condition: Unknown
Due 13 February 1994
Resolved 17 February 1994
Accommodation/Occupational Safety
Issued 9 February 1994
Resolved
PERFORM GENERAL HOUSEKEEPING DUTIES ENTIRE AREA 1ST DECK BAR AREA.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Lifesaving
Issued 9 February 1994
Resolved
INSTALL/POST MAXIMUM CAPACITY PLATES FOR 2ND AND 2ND/3RD DECKS, NUMBERS TO CORRESPOND W/STABILITY LETTER.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Lifesaving
Issued 9 February 1994
Resolved
REPLACE WEATHERED/DETERIATED GRAB LINES TO TWO RING BOUYS.
Condition: Unknown
Due 13 February 1994
Resolved 17 February 1994
Fire Fighting
Issued 9 February 1994
Resolved
REPLACE 3 TEMPORARY PORTABLE EXTINGUISHERS WITH ORIGINAL B-II CO2 PORTABLE EXTINGUISHERS WHEN RETURNED FROM SERVICING UNIT.
Condition: Unknown
Due 13 February 1994
Resolved 17 February 1994
Lifesaving
Issued 9 February 1994
Resolved
REMOVE ALL PORTABLE EXTENSION LIGHTING FROM ENGINEROOM. IF LIGHTING IS INADEQUATE, SUBMIT PROPOSAL FOR INCREASED LIGHTING TO OCMI.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Construction/Loadline
Issued 9 February 1994
Resolved
REPAIR BROKEN SWITCH FOR COMPT 5 REMOTE BRIDGE INDICATOR FOR WTD.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Lifesaving
Issued 9 February 1994
Resolved
POST NEW EMERGENCY CHECK OFF LIST 3RD DECK
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Construction/Loadline
Issued 9 February 1994
Resolved
SUBMIT WEIGHT OF HEATING UNIT REMOVED FROM VESSEL TO OCMI FOR POSSIBLE RECALCULATIONS OF VESSEL STABILITY.
Condition: Unknown
Due 10 March 1994
Resolved 17 February 1994
Construction/Loadline
Issued 10 February 1993
Resolved
DEMONSTRATE PROPER OPERATION OF BALLAST PUMP ULTILIZED AS SECONDARY BILGE PUMP.
Condition: Unknown
Due 11 February 1993
Resolved 18 February 1993
Lifesaving
Issued 21 February 1992
Resolved
REPLACE MISSING LIFE JACKET DONNING PROCEDURE PLACARD.
Condition: Unknown
Due 10 April 1992
Resolved 6 April 1992
Fire Fighting
Issued 22 April 1991
Resolved
REPLACE ALL UNAPPROVED POWHATAN 250 FIRE NOZZLES WITH COAST GUARD APPROVED NOZZLES AS PER 46 CFR 181.15-10(D)(2).
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Electrical
Issued 21 February 1991
Resolved
REPLACE IN-OPERATIVE EMERGENCY LIGHT MAIN DECK FORWARD PORT DOOR.
Condition: Unknown
Due 21 February 1991
Resolved 21 February 1991
Engineering
Issued 21 February 1991
Resolved
PROVIDE STRAINER AND FOOT VALVE OR CHECK VALVE IN EACH BILGE SUCTION LINE IN FORWARD 2 AND AFTER 3 COMPARTMENTS.
Condition: Unknown
Due 21 February 1991
Resolved 21 February 1991
Electrical
Issued 21 February 1990
Resolved
PROVIDE BOX FOR UNUSED 2 INCH CABLE LOCATED UNDER THE WHEELHOUSE CONSOLE.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Navigation
Issued 21 February 1990
Resolved
PROVIDE APPROVED (PERKO) BULBS FOR ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Fire Fighting
Issued 2 March 1989
Resolved
PROVIDE SUITABLE STRAINERS FOR BILGE SUCTION - FOREPEAK AND NO. 1 VOID.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Fire Fighting
Issued 2 March 1989
Resolved
PROVIDE (1) B-II FIRE EXTINGUISHER (PASSENGER AREA).
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Construction/Loadline
Issued 2 March 1989
Resolved
REMOVE PAINT FROM KNIFE EDGES OF WATERTIGHT DOOR(S).
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Lifesaving
Issued 2 March 1989
Resolved
LABEL CHILD LIFE-JACKET STOWAGE-THIRD DECK.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Construction/Loadline
Issued 2 March 1989
Resolved
RE-ALGIN THE ENGINE ROOM WATERTIGHT DOOR.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Accommodation/Occupational Safety
Issued 2 March 1989
Resolved
CLEAN VENTILATION SYSTEM.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Fire Fighting
Issued 2 March 1989
Resolved
TEST FIRE PUMP.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Navigation
Issued 2 March 1989
Resolved
PROVIDE 12 APPROVED DISTRESS FLARES.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Documentation
Issued 2 March 1989
Resolved
PROVIDE VALID FCC LICENSE.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Construction/Loadline
Issued 3 March 1988
Resolved
INSTALL A-60 INSULATION ON THE OVERHEAD AND BULKHEADS OF THE NO. 5 COMPARTMENT (LIQUOR LOCKER).
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Fire Fighting
Issued 24 April 1987
Resolved
THE INSTALLATION OF THE AIR LINE TO THE FIRE MAIN SHALL BE INSPECTED AND TESTED BY CG MARINE INSPECTORS PRIOR TO THE DISCONTINUATION OF THE PREVIOUSLY REQUIRED FIRE MAIN SYSTEM TEST.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Fire Fighting
Issued 19 March 1987
Resolved
SUBMIT A PLAN FOR THE MODIFICATION TO THE FIRE PUMP SUCTION TO CORRECT THE PROBLEM WITH CLOGGING BY DEBRIS FROM THE RIVER. THIS PLAN IS TO BE SUBMITTED PRIOR TO 20 APRIL 1987. ONCE THE PLAN IS APPROVED BY THE USCG, MAKE THE NECESSARY MODIFICATIONS TO PROVIDE ADEQUATE PRESSURE.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Fire Fighting
Issued 19 March 1987
Resolved
REPLACE FIRE PUMP GUAGE GLASS OR RENEW GUAGE.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Fire Fighting
Issued 19 March 1987
Resolved
UNTIL ITEM NO. 3 IS COMPLETED, THE FIRE PUMP WILL BE TESTED AT FULL PRESSURE WEEKLY TO INSURE IT'S PROPER OPERATION. THE RESULTS OF THIS TEST ARE TO BE LOGGED IN THE VESSEL'S LOGBOOK.-VFOD
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Lifesaving
Issued 19 March 1987
Resolved
PROVIDE 14 ADULT LIFE PERSERVERS. PASSENGER CAPACITY IS REDUCED TO 586 UNTIL THE ADDITIONAL LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 19 March 1987
Resolved 19 March 1987
Construction/Loadline
Issued 6 March 1986
Resolved
REPLACE MISSING REACH ROD FOR BILGE SUCTION VALVE AT COLLISION BULKHEAD.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Construction/Loadline
Issued 6 March 1986
Resolved
REMOVE ALL FLAMABLES FROM ENGINEROOM AND GENERATOR ROOM AND STORE IN FLAMABLE LIQUID STORAGE LOCKER.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Electrical
Issued 6 March 1986
Resolved
REMOVE OR REPAIR LIGHT JUNCTION BOX IN THIRD WATER TIGHT COMPARTMENT FROM AFT.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Documentation
Issued 6 March 1986
Resolved
OBTAIN AND DISPLAY A CURRENT FEDERAL COMMUNICATIONS COMMISION CERTIFICATE.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Accommodation/Occupational Safety
Issued 6 March 1986
Resolved
REPLACE ELECTRICAL WIRING, INCLUDING GROUND WIRE, FOR PORT ENGINEROOM AIR EXHAUST FAN.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Accommodation/Occupational Safety
Issued 6 March 1986
Resolved
REMOVE DEBRIS AND CLEAN DECKS IN ENGINEROOM AND GENERATOR ROOM.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Deck/Cargo
Issued 6 March 1986
Resolved
SECURE END OF ANCHOR LINE TO ADEQUATE KEVEL.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Deck/Cargo
Issued 6 March 1986
Resolved
REPLACE ANCHOR LINE WITH LARGER DIAMETER OR PROVIDE DATA SHOWING PRESENT LINE IS ADEQUATE FOR INSTALLATION.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Electrical
Issued 6 March 1986
Resolved
MAKE ALL WATER TIGHT DOOR OPEN LIGHTS OPERABLE.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Engineering
Issued 6 March 1986
Resolved
REPLACE MISSING REACH ROD FOR EMERGENCY ENGINE FUEL SHUT OFF VALVE.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986