Records from 2005 to 2026. Most recent: inspection, 26 February 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 January 2025
Resolved
Vessels port MDE had a leak on the raw water pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 11 March 2025
Resolution: Vessel replaced raw water pump with new one.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 January 2024
Resolved
The owner, managing operator or a qualified servicing facility shall conduct the following tests for portable fire extinguisher inspection, maintenance procedures and hydrostatic tests iaw NFPA 10. Annual third party servicing certificate not onboard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2024
Resolution: Servicing report provided through email
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 28 June 2023
Resolved
Each vessel must be equiped with a public address system. Vessels installed public address system had speakers that didnt work on some of the outside deck areas. Repair inop. speakers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 24 August 2023
Resolution: Vessel repaired vessels loud hailer speakers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be corrected and all required guards and protective devices
must be in satisfactory condition. Vessel had excess oil on the MDE's and generators. Clean off oil on all engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 24 August 2023
Resolution: Vessel cleaned all engines and bilges of oily residue.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 June 2023
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device:
A self-propelled vessel that is certificated to carry more than 150 passengers.
Vessel Owner/Operator must re-submit in writing an exemption request within 30 days or provide proof of a valid AIS installed on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 8 September 2024
Resolution: Information received
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 June 2023
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not had an inspection this year and is not allowed to carry passengers until the vessel receives a satisfactory inspection/COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2023
Resolved 8 September 2024
Resolution: Cert recieved
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 March 2022
Resolved
At Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. All high level alarms on vessel did not provide an audible alarm when triggered by high water level test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2022
Resolution: All indicators operational.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 March 2022
Resolved
All observed unsafe practices, including fire hazards and hazardous situations, must be corrected. Noted oily mixture throughout bilges under engines and in corner bilge of engine room. Also noted overhead fire protection was loose on overhead. Thoroughly clean bilge and repair hanging overhead fire protection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2022
Resolution: All items rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2022
Resolved
All observed unsafe practices, including hazardous situations, must be corrected. Noted several electrical outlet strips located throughout vessel. Remove outlet strips/fire hazards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2022
Resolution: Rectified.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 March 2022
Resolved
Portable fire extinguishers shall be inspected monthly, as per NFPA 10. No records of inspections onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 1 April 2022
Resolution: Rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022
Resolved
Security Drills must be conducted and logged at least every 3 months.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2022
Resolved 1 April 2022
Resolution: Rectified.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2021
Resolved
Fire drills are required monthly for crew. Last fire drill was conducted in December of 2019.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Fire drill conducted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2021
Resolved
Abandon ship and MOB drills for crew are required monthly. Last drills conducted was in December of 2019.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Abandon ship and MOB drills conducted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 March 2021
Resolved
Crew must be trained to perform duties in case of emergency. No crew is currently employed due to covid restrictions. Once crew is hired, they must have proper emergency/first aid training prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Crew employed and training conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2021
Resolved
Batteries must be secured to protect against exposure to water splash or spray. Battery box/lids must be properly secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Batteries boxes/lids properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 March 2021
Resolved
Electrical equipment must be maintained to protect passengers, crew, and other persons from electrical/fire hazards. Generator windings in need of cleaning.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Generator windings cleaned.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 March 2021
Resolved
Each vessel must have adequate emergency lighting. The emergency lighting in the 02 passenger deck is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Emergency lighting operable.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2021
Resolved
Vessel control systems must be suitable for the purpose intended. Sound signaling device is inoperable due to a leak within the system.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Sound signaling device operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 January 2019
Resolved
Vessel required to have alcohol test strips on board. The alcohol test strips are expired. Provide test strips tath are current.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 January 2019
Resolved
Vessel required to have E-lights at emergency egress locations. The E-light is in-operable on the forward 01 Deck. Prove operation of E-Light. Until staisfactorily repaired, the vessel is restricted to daylight opeartions only.
Action required: 705 - Other - as specified
Resolved 7 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 January 2019
Resolved
Ship's generator should be in servicable condition. The windings on the generator are covered in oil and dust, caussing a potential fire hazard, or failure of the generator. Clean windings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2019
Resolved 7 February 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2019
Resolved
Nav lights are required to be in compliance with UL 1104. The lenses on the port and starboard running light are not cleared, thus limiting the illumination of the lights. Clean or replace lenses to be in compliance with UL 1104. Vesssel is restricted to day light operations only, until nav lights are in compliance.
Action required: 705 - Other - as specified
Resolved 7 February 2019
Engineering › Bilge Water Management System › Interface Detector
Issued 2 April 2018
Resolved
Mount bilge alarm in #6 Upper Void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 27 June 2018
Resolution: Bilge alarm was properly mounted.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 April 2018
Resolved
Crop and renew the watsed baffle plates in the #6 upper void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 6 November 2018
Resolution: Special note added.
Construction/Loadline › Structures › Ventilators
Issued 2 April 2018
Resolved
Replace the wasted vent on the gooseneck for the #7 port void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 27 June 2018
Resolution: The #7 port void vent pipe was repaired and found in compliance.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 2 April 2018
Resolved
Replace missing/damaged lagging on exhaust system for both main engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 27 June 2018
Resolution: The lagging on the exhaust systems for both MDE's was replaced and found to be in compliance.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 2 April 2018
Resolved
Remove the waste oil in the bucket by the generator.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 April 2018
Resolved 2 April 2018
Resolution: The bucket of waste oil in the engine room was removed from the vessel.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 2 April 2018
Resolved
Remove all oil and residue from the collection boxes for the shaft on each main engineand provide a means to prevent oil from entering it, and secure the hose for the sump pump to ensure it is not portable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 27 June 2018
Resolution: The collection boxes for the shaft water has had all oil and its resudue removed, and an aluminum plate was mounted over the box to prevent oil from enetering it, and the hose was secured.
Construction/Loadline › Penetrations › Gasket
Issued 2 April 2018
Resolved
Replace gasket on void cover on forward engine room bulkhead, starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 27 June 2018
Resolution: The gasket was repalced and found in servicable condition for the void cover on the forward engine room bulkhead.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 April 2018
Resolved
Markings for fire extinguishers near pilot house need replacing, and fire extinguisher bracket for the fire extinguisher in the pilot house needs to be installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 27 June 2018
Resolution: The markings for the fire extinguishers near the pilot house were replaced, and a new fire extinguisher bracket was installe din the pilot house. All were found to be in compliance with the regulations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 April 2018
Resolved
Emergency lighting on second deck not working and needs repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 27 June 2018
Resolution: The emergency light on the second deck was repaired and found to be in compliance with the regualtions.
Fire Fighting › Firemans Outfit › Axe
Issued 2 April 2018
Resolved
Fire axe mounted on pilot house is rotted out and needs replacing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 27 June 2018
Resolution: The fire axe mount near the piulot house was replaced and found to be in servicable condition.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 April 2018
Resolved
Limited to 310 persons on board due top not enough adult life jackets required. Needs to provide 11 more CG approved type I PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 27 June 2018
Resolution: Eleven additional CG approved life jackets were provided to increase the persons on board back to its original allowance, as listed on the COI.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 6 February 2018
Resolved
Port hand rail has some wasted areas that need repaired. 46CFR115-610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 2 April 2018
Resolution: The port side hand rail was replaced with new materials and was found satisfactory.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 April 2017
Resolved
Alco strips expire this month and need replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 July 2017
Resolution: Received photo and email of of approved alco strips for vessel.
Documentation › Certificates/Documents › Stability Letter
Issued 18 April 2017
Resolved
Post most current stability letter. Corrected during exam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Vessel found stability letter and posted.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 April 2017
Resolved
Update ships log for daily checks to add ready for sea with what needs uncovered, or installed from original position.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 April 2017
Resolved
Fire control plan needs updated to show proper locations and directions of fire escapes and fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Lifesaving › Lifebuoys › Serviceable
Issued 18 April 2017
Resolved
Replace life ring near pilot house and 2nd deck with new and label.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2017
Resolved
Life jackets on 3rd deck need replaced or removed then relabel stowage. These were extras but damaged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017
Resolved
Fixed lighting in engine room needs mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Electrical › Lighting (service) › Outlet Box
Issued 18 April 2017
Resolved
Outlet covers in engine room need proper covers, located for both prop shaft sumps and panel board area in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 April 2017
Resolved
Fire extinguisher bracket in engine room need proper bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017
Resolved
Deck number 2 has a missing bulb cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 14 June 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2016
Resolved
Expired items in first aid kit. Replace expired items with unexpired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Purchased new items to replace expired items.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 March 2016
Resolved
No record of EAP training for crew or supervisors. Conduct training and document.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Provided documentation that all crewmembers and supervisory personnel received required training.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 March 2016
Resolved
Provide updated copy of Inland Navigation Rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Provided copy of current Nav rules
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 March 2016
Resolved
Alcohol test strips expired. Provide new, approved test strips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Approved and current alcohol testing devices on board.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 March 2016
Resolved
Carpet extended 7 inches above deck. Remove carpet in excess of 4 inches above deck and provide evidence of carpet design flame spread rating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Excess carpet removed. Carpet now at 4" above the deck.
Fire Fighting › Means of Escape › Blocked
Issued 22 March 2016
Resolved
Emergency escape blocked by cabinet on 2nd deck. Provide means of escape not less than 32 inches wide.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Cabinet blocking emergency egree removed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 March 2016
Resolved
CO2 bottles on 1st and 2nd deck bars not properly secured. Provide proper brackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: CO2 bottles placed in brackets and properly secured.
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2016
Resolved
Remove extension cords from behind 1st and 2nd deck bars.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Extension cords removed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 March 2016
Resolved
Properly secure all appliances in the 3rd deck snack shop.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: All appliances properly secured.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 22 March 2016
Resolved
Ensure all smoke detectors meet UL 217 or recreational vehicle standards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Installed additonal UL 217 approved smoke detectors.
Documentation › Markings/Placards › Capacity Marking
Issued 22 March 2016
Resolved
Improper markings for passengers allowed on 4th deck. [name withheld] approved stability cert
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: 4th deck properly marked IAW valid Stability letter.
Fire Fighting › Fire Main › Valves
Issued 22 March 2016
Resolved
Fire main suction sea valve not operable. Make valve able to be opened and closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Demonstrated porper operation of sea valve.
Engineering › Fuel Oil Service System › Hose
Issued 22 March 2016
Resolved
Multiple worn hoses on starboard engine. replace hoses with new, approved hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: replaced hoses with new, approved hoses
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2016
Resolved
Remove rust from under water tank in port #3 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Rust/wastage removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 March 2016
Resolved
Wires not properly supported in "upper 6" void. Provide proper supports and spacing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Wires properly supported.
Stability › Watertight Integrity › General
Issued 22 March 2016
Resolved
Stuffing tube in "upper 6" void wasted and not watertight. Make tube watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Stuffing tube cleaned and sealed with marine type epoxy. Will need to be permanantly repaired at next drydock.
Electrical › Electric Generation Source (service) › Generator
Issued 22 March 2016
Resolved
Found 226 Amp/40C generator installed. Vessel is required to have a 50C generator or 40C generator that is de-rated to 80%. De-rate generator with 207 amp or less breaker. As no main breaker or fuse installed, provide appropriate electrical panel w/ double pole-double throw switch for shore/generator power. Provide repair proposal prior to installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 7 July 2016
Resolution: Installed 200 amp circuit breaker for generator in engine space. Additionally, installed 225 amp breaker for shore tie on main deck.