Records from 1985 to 2025. Most recent: operational control imposed, 13 November 2025.
Inspection history · 120
12 November 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8273464
10 July 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8266652
17 October 2024
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8020263
19 October 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7811405
17 May 2023
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7690906
2 November 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7587907
1 November 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7343734
8 July 2021
ACP Drydock Oversight · In-Service Inspection · ACP COI Oversight · Administrative Inspection · Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7249782
23 June 2021
Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7234145
25 September 2020
ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7065051
30 September 2019
Periodic Inspection · Administrative Inspection · ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6839591
20 March 2019
Administrative Inspection · Special · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6645984
7 September 2018
ACP Annual Oversight · Administrative Inspection · Special · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6534734
22 August 2017
Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6248495
22 April 2016
ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5907207
30 September 2015
ACP Annual Oversight · MTSA/ISPS Verification · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5739356
19 August 2014
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4978914
19 July 2012
ACP Annual Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4395612
22 September 2010
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3863159
30 September 2008
ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3336430
6 July 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2757536
11 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2565088
1 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480804
27 January 2005
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2281727
16 November 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2268662
3 June 2004
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 2087449
20 April 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2048182
1 March 2004
Type not recorded
No type recorded · Activities Europe · Activity 2049913
11 February 2004
Type not recorded
No type recorded · Activities Europe · Activity 2049923
2 February 2004
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2004624
28 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995558
6 January 2004
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1976858
31 January 2003
Administrative Inspection · Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742956
24 January 2003
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1734946
12 April 2002
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1603964
15 March 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1493893
13 December 2001
ACP COI Oversight
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1475564
11 December 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 187909
19 April 2001
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465633
2 August 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 821543
19 January 2000
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1429298
24 June 1999
Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1462006
11 March 1999
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1413500
9 December 1998
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 807218
31 July 1998
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1364828
15 July 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 513029
24 April 1998
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 789734
5 February 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 32664
4 November 1997
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1118455
9 September 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1123492
19 August 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 785405
5 August 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 784201
3 July 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 777777
23 May 1997
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1108849
21 April 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1091694
5 February 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1104166
3 October 1996
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148336
6 August 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1374694
25 July 1996
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1398503
6 June 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185014
16 May 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 872472
26 April 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1190138
19 April 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1081845
1 December 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1188108
20 September 1995
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1358916
13 July 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 164035
6 July 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 882786
14 March 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 866480
2 December 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 826568
7 October 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1176525
1 October 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 108027
1 October 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 491767
12 September 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 521835
9 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 864480
23 August 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1173866
4 August 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1177220
13 July 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1176040
30 April 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 858405
16 March 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1165683
25 February 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1164089
19 January 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 852200
29 September 1993
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1154016
21 September 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1153526
17 August 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1152913
28 May 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1146577
30 April 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 837660
16 April 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1149343
30 March 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435360
3 March 1993
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 86432
27 February 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 83537
28 October 1992
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 954388
24 August 1992
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 958614
4 August 1992
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 950408
7 February 1992
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 958705
2 January 1992
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 945845
24 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252786
25 August 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243754
14 August 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244089
31 July 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1247053
14 June 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259584
29 April 1991
Damage Survey · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 916957
3 January 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 922864
26 December 1990
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 932972
16 December 1990
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1241825
26 October 1990
Drydock Extension
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 918853
1 September 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351784
30 August 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1233860
29 August 1989
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 920802
11 August 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1233201
30 August 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347234
26 August 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891217
12 August 1988
Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351359
29 April 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038870
29 April 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349663
18 April 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030584
9 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339860
27 August 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202652
25 March 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1019165
23 September 1985
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 986877
23 September 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1006164
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 October 2024
Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location. Fire detection system for the accommodation was found with 2 active faults as follows. "Fault (7) Sec 2 Section unit(s) missing"; "Fault (121) Loop 2 Cable Break". 60 SOLAS II-2/61
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2024
Resolved 21 October 2024
Resolution: RO accepted referral, issued statutory finding. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 October 2023
Resolved
All required fire detection shall be capable of automatically indicating the presence or indication of fire.
There was a detector in the LP CO2 room, with a latex glove covering the face.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 19 October 2023
Resolution: Glove removed upon finding it.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 June 2021
Resolved
Ships shall be provided with a main steering gear to the satisfaction of the Administration. Primary steering was responding incorrectly to helm commands on the bridge. If 20 degrees port was issued, the steering went to twenty degrees starboard.
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Repairs were made to the steering comapartment by qualified third party and tested in the prescence of ABS and USCG. Test was satisfactory in all modes.
Engineering
Issued 24 June 1999
Resolved
HYDRO ON WASTE HEAT BOILER OVERDUE.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Engineering
Issued 31 July 1998
Resolved
Eliminate seawater leak in way of starboard Main Diesel Engine seawater 8" elbow, lower level.
Condition: Unknown
Due 15 August 1998
Resolved 21 September 1998
Electrical
Issued 31 July 1998
Resolved
PROVIDE CORROSSION RESISTANT LINING FOR EMERGENCY GENERATOR BATTERY BOX.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Accommodation/Occupational Safety
Issued 31 July 1998
Resolved
RENEW VENT CLOSING DEVICES TO VENTS ABOVE FWD BOSN LOCKER.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Fire Fighting
Issued 31 July 1998
Resolved
RENEW BROKEN SPINNERS (AIR FLOW INDICATORS) ON KIDDE SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Fire Fighting
Issued 31 July 1998
Resolved
CONDUCT FIRE AND BOAT DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Fire Fighting
Issued 31 July 1998
Resolved
PROVE PROPER OPERATION OF CO2 ALARM - C DECK FWD.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Fire Fighting
Issued 31 July 1998
Resolved
REPLACE LENS TO CO2 ALARM LIGHT IN WAY OF B DECK FWD.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Accommodation/Occupational Safety
Issued 31 July 1998
Resolved
RENEW HAND RAILS IN WAY OF STBD FOCSLE AND PORT SIDE OIL SPILL LOCKER.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Accommodation/Occupational Safety
Issued 31 July 1998
Resolved
REPLACE FASTENER TO UPPER FWD PART OF LADDER 3RD POOP DECK TO 4TH POOP DECKSTBD SIDE.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Accommodation/Occupational Safety
Issued 31 July 1998
Resolved
RENEW INTERIOR GUARD ON FAN IN CO2 ROOM.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Construction/Loadline
Issued 31 July 1998
Resolved
RENEW WASTED FASTENERS ON STBD AP CTR MANHOLE COVER IN WAY OF FANTAIL.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Electrical
Issued 31 July 1998
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN WAY OF C DECK AFT ESCAPE TRUNK.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Construction/Loadline
Issued 31 July 1998
Resolved
RENEW CENTER DOG BOLT ON PORT SIDE BUNKER PORT.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Electrical
Issued 31 July 1998
Resolved
PROPERLY MARK AND REPLACE BULBS AS NEEDED TO EMERGENCY LIGHTING.
Condition: Unknown
Due 15 August 1998
Resolved 17 September 1998
Electrical
Issued 31 July 1998
Resolved
Provide proper lagging and/or heat shielding on Emergency Generator exhaustmanifold and vertical spool piece.
Condition: Unknown
Due 15 August 1998
Resolved 21 September 1998
Engineering
Issued 31 July 1998
Resolved
Demonstrate proper operation of Oily Water Seperator unit.
Condition: Unknown
Due 15 August 1998
Resolved 21 September 1998
Engineering
Issued 31 July 1998
Resolved
Prove proper operation of Safety Relief Valve for starboard start air flaskand control air flask.
Condition: Unknown
Due 15 August 1998
Resolved 21 September 1998
Lifesaving
Issued 23 May 1997
Resolved
Conduct fire and boat drill upon crewing, activation, or underway period.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Lifesaving
Issued 23 May 1997
Resolved
PROVIDE A BATTERY WITHIN EXPIRATION DATE FOR THE INSTALLED EPIRB.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Accommodation/Occupational Safety
Issued 23 May 1997
Resolved
PROVIDE PROOF AND PROPER DOCUMENTATION OF COMPLETED WEIGHT TEST OF THE TWO INSTALLED VESSEL ELEVATORS. DOCUMENTATION TO PROVIDED TO THE [name withheld] IN ACCORDANCE WITH CURRENT SIP PROGRAM.
Condition: Unknown
Due 23 June 1997
Resolved 9 June 1997
Lifesaving
Issued 23 May 1997
Resolved
PROVIDE DOCUMENTATION OF LIFERAFT SERVICING.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Navigation
Issued 23 May 1997
Resolved
UPON VESSEL UNDERWAY PERIOD UPDATE VESSEL DEVIATION TABLE AND PROVIDE COPY ON BOARD AND TO THE COGNIZANT OCMI.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Construction/Loadline
Issued 23 May 1997
Resolved
PROVE PROPER OPERATION OF THE VESSEL OIL FIRED BOILER INCLUDING ALL SAFETIES AND SHUTDOWNS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 June 1997
Resolved 9 June 1997
Electrical
Issued 23 May 1997
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF THE MAIN ENGINE CONTROL CONSOLE MONITORING SYSTEM DISPLAY.
Condition: Unknown
Due 23 June 1997
Resolved 9 June 1997
Accommodation/Occupational Safety
Issued 20 September 1995
Resolved
COMPLETE REPAIRS TO CARGO ELEVATOR AND PROVE PROPER OPERATION OF SAME INCLUDING SAFETY DEVICES.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Lifesaving
Issued 20 September 1995
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO ACTIVATION OF VESSEL.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Accommodation/Occupational Safety
Issued 20 September 1995
Resolved
PROVIDE STORAGE RACKS FOR COMPRESSED GAS CYLINDERS.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Engineering
Issued 20 September 1995
Resolved
SET AND SEAL WASTE HEAT BOILER SAFETY VALVE.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Documentation
Issued 20 September 1995
Resolved
FCC DOCUMENTS TO BE REISSUED PRIOR TO ACTIVATION OF VESSEL.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Fire Fighting
Issued 6 July 1995
Resolved
Top off bulk CO2 storage tanks. Vessel shall not load cargo nor depart theport of Jacksonville before CO2 bulk tanks are re-filled.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 6 July 1995
Resolved
Provide report of annual servicing for bulk CO2 system, including a summaryof repairs conducted, to [name withheld] not later than 20JUL95.
Condition: Unknown
Due 20 July 1995
Resolved 7 July 1995
Lifesaving
Issued 9 September 1994
Resolved
Provide a hand crank for port lifeboat davits, portable air operated winch.Lifeboat to be manually cranked home after limit switches activate.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Engineering
Issued 4 August 1994
Resolved
Provide log entry from next voyage or demonstrate operation of waste heat safety relief valve.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 4 August 1994
Resolved
Conduct fire & boat drills upon activation but not later than 04AUG96.
Condition: Unknown
Due 10 September 1994
Resolved 10 September 1994
Lifesaving
Issued 4 August 1994
Resolved
Provide a means of communications from forecastle to bridge per 46 CFR 113.30-5(g).
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Electrical
Issued 4 August 1994
Resolved
Repair standoffs/supports as follows: 1)port & stbd anchor microswitches & wiring standoffs. 2)hydraulic piping up port aft crane tower supports. 3) stern nav light post.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Lifesaving
Issued 4 August 1994
Resolved
Provide canopy cover for personnel protection for both open lifeboats.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Deck/Cargo
Issued 4 August 1994
Resolved
Install boom angle indicator and mark safe working load on hydraulic pedestal stores crane.
Condition: Unknown
Due 4 August 1995
Resolved 24 August 1994
Accommodation/Occupational Safety
Issued 19 January 1994
Resolved
Install a light in top of passenger elevator space, from emergency power source, to illuminate escape ladder. To be completed to the satisfaction ofattending marine inspector prior to 19FEB94.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Engineering
Issued 17 August 1993
Resolved
REPAIR STBD. MAIN DIESEL ENGINE MUFFLER LAGGING.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Accommodation/Occupational Safety
Issued 17 August 1993
Resolved
DEMONSTRATE PASSENGER AND CARGO ELEVATOR SAFETY DEVICES.
Condition: Unknown
Due 17 August 1993
Resolved 17 August 1993
Accommodation/Occupational Safety
Issued 17 August 1993
Resolved
REPAIR AND DEMONSTRATE ENGINE CONTROL ROOM AFT ACCESS DOOR HANDLE PRIOR TO DEPARTURE OF VESSEL FROM JACKSONVILLE.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Navigation
Issued 17 August 1993
Resolved
DEMONSTRATE PROPER OPERATION OF RUDDER ANGLE INDICATORS AND EACH REPEATER PRIOR TO VESSELS DEPARTURE FROM JACKSONVILLE.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Electrical
Issued 17 August 1993
Resolved
PLACE EMERGENCY MARKINGS ON EACH EMERGENCY LIGHT THROUGHOUT CARGO HOLDS.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Lifesaving
Issued 17 August 1993
Resolved
PRIOR TO VESSEL ACTIVATION/SAILING CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 17 August 1993
Resolved 17 August 1993
Electrical
Issued 17 August 1993
Resolved
REMOVE OR TERMINATE IN A JUNCTION BOX ALL DEAD END CABLES IN FORWARD PUMP ROOM.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Electrical
Issued 17 August 1993
Resolved
INSTALL AN INNER DIVISION PANEL IN GALLEY POWER DISTRIBUTION PANEL TO PREVENT ACCESS TO WIRE CONNECTIONS.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Lifesaving
Issued 17 August 1993
Resolved
PROVIDE PROVISIONS (46 PACKS AT 3400 CAL) FOR EACH LIFEBOAT AS A SUBSTITUTION FOR CONDENSED MILK REQUIREMENT.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Lifesaving
Issued 17 August 1993
Resolved
PROVIDE ONE QUART OF ILLUMINATING OIL FOR EACH LIFEBOAT.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Lifesaving
Issued 17 August 1993
Resolved
PROVIDE A WEAK LINK FOR STBD. AFT LIFERAFT PAINTER.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Lifesaving
Issued 17 August 1993
Resolved
PROPERLY APPLY RETROREFLECTIVE TAPE ON LIFEBOATS AS REQ'D BY SOLAS REG. 30.2.7.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Accommodation/Occupational Safety
Issued 17 August 1993
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING GENERAL ALARM BELLS: OUTSIDE RADIO ROOM, OUSIDE MASTERS CABIN, FOC'SLE AND LOWER FWD. HOLD PORT SIDE AFT.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Fire Fighting
Issued 17 August 1993
Resolved
PROVIDE PROPER "SPINNER" ELEMENTS IN THE SMOKE DETECTION PANELS WHICH ARE ADEQUATE FOR VESSEL VENTILATION.
Condition: Unknown
Due 17 September 1993
Resolved 22 September 1993
Fire Fighting
Issued 16 April 1993
Resolved
Install zone indicator numbers on deck standpipes missing numbers (2,11,12,30).
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Fire Fighting
Issued 16 April 1993
Resolved
Post copy of zone indicator telltale on operating side of each detector box. (Figure 4-2 manufacturers instruction book).
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Fire Fighting
Issued 16 April 1993
Resolved
Permanantly install zone indicator bar on inboard detector box, i.e. 19-36,to correspond with smoke detoctor zone schematic.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Construction/Loadline
Issued 30 March 1993
Resolved
Drydock vessel and repair wasted bottom plate between frames 210 and 211 inway of fwd deep tank.
Condition: Unknown
Due 30 March 1993
Resolved 15 April 1993
Fire Fighting
Issued 30 March 1993
Resolved
Prove proper operation of fixed CO2 system prior to departure of Norfolk, VA.
Condition: Unknown
Due 30 March 1993
Resolved 15 April 1993
Fire Fighting
Issued 30 March 1993
Resolved
Properly mark all skylight remote closures, emergency fire pump and generator fuel shutdowns, CO2 system alarms, general alarm bells and fire dampers as illistrated on the ships Fire Control Plan in accordance with 46CFR 97.37.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 30 March 1993
Resolved
Test waste heat boiler safety valve and provide [name withheld] log entry of results to MSO Hampton Roads, VA.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Navigation
Issued 30 March 1993
Resolved
Update or replace Sailing Directions prior to offical activation of the vessel.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Documentation
Issued 30 March 1993
Resolved
Revise loading/stability info to reflect tallow/ballast tank conversion to sludge tank and submit to Coast Gaurd MSC for approval. Upon determination of the effect on the vsl's tonnage submit for ammended COI, Vsl's Document,SOLAS Safety Equip. Cert. (include 83 ammendments) & IOPP Certificate.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Electrical
Issued 4 August 1992
Resolved
PROPERLY MARK EMERGENCY LIGHTS IN CARGO HOLDS.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Lifesaving
Issued 4 August 1992
Resolved
CONDUCT WEIGHT TEST OF PORT & STBD LIFEBOATS, DAVITS, & FALLS.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Lifesaving
Issued 4 August 1992
Resolved
PRIOR TO ACTIVATION CONDUCT FIRE & BOAT DRILLS, RANDOM AUTOMATION TEST. OPERATE FIRE PUMPS,BILGE PUMPS,STEERING GEAR,GENERATORS,ANCHOR MACHINERY, BRIDGE EQUIPMENT.MAKE AVAILABLE LIFEBOAT PROVISIONS & OFFICER LICENSES.ALL EQUIPMENT REMOVED FOR LAY-UP WILL BE RE-INSTALLED & TESTED.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Lifesaving
Issued 4 August 1992
Resolved
PROVIDE & INSTALL LIFERAFTS OF AGGREGATE CAPACITY TO ACCOMODATE THE TOTAL NUMBER OF PERSONS ON BOARD, PER SOLAS (III.26.3). S.E.C. TO BE UPDATED UPON COMPLETION.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Engineering
Issued 4 August 1992
Resolved
MAKE PERMANENT REPAIR TO LOW TEMPERATURE COOLING SEA WATER DISCHARGE PIPING, ENGINEROOM LOWER LEVEL, STBD SIDE, IN WAY OF SOFT PATCH.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Construction/Loadline
Issued 4 August 1992
Resolved
MAKE PERMANENT REPAIR TO DAMAGED PLATE, STBD SIDE 'C' DECK, FRAMES 107-108,ADJACENT TO FRESH AIR SUPPLY DUCT TO 'D' DECK.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Lifesaving
Issued 4 August 1992
Resolved
PROVE LIMIT SWITCHES ON STARBOARD LIFEBOAT DAVIT.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Fire Fighting
Issued 14 August 1991
Resolved
PROVE PROPER OPERATION OF THE FWD EMERGENCY FIRE PUMP TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. RETURNING CASREP 121930ZAUG91.
Condition: Unknown
Due 23 October 1991
Resolved 23 October 1991
Lifesaving
Issued 16 December 1990
Resolved
D10. PROPERLY POST PLACARDS OF INSTRUCTIONS FOR LAUNCHING AND INFLATING INFLATABLE LIFERAFTS AS PER 46 CFR 97.39.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Construction/Loadline
Issued 16 December 1990
Resolved
D9. MAKE ALL THE BALLAST TANK OVERBOARD DISCHARGE PIPING FLANGES WATERTIGHT
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
D6. PROVIDE PROPERLY PLUMBED EXHAUST LINES FOR THE DRYERS IN BOTH THE CREW AND OFFICER LAUNDRY.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Fire Fighting
Issued 16 December 1990
Resolved
E7. INSTALL AND PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP DISCHARGEPRESSURE GAUGE.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Deck/Cargo
Issued 16 December 1990
Resolved
D1. MAKE THE VESSEL SPECIALLY SUITABLE FOR THE CARRIAGE OF VEHICLES AS PER 46 CFR 90.10-37.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E16. LABEL GRAVITY TANK AND REDUCTION GEAR OIL EMERGENCY SHUTDOWN VALVES IN ENGINE ROOM.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E15. REPAIR/DISCONNECT DEAD END WIRING LOCATED NEXT TO STARBOARD STEERING GEAR PUMP CONTROLLER IN AFT STEERING.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E24. REMOVE DEBRIS FROM PORT AND STARBOARD PIPE TUNNELS, AND RESPECTIVE BILGE WELLS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E23. PROVE PROPER OPERATION OF THE GENERAL CARGO PANNEL (#S5B33) IN ECC. POWER INDICATION LIGHT STAYS ON AFTER TRIP.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Fire Fighting
Issued 16 December 1990
Resolved
E22. PLUG OPEN CIRCUIT LEAD IN STEERING GEAR FLAT GENERAL ALARM BEACON.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Navigation
Issued 16 December 1990
Resolved
E21. REPAIR HYDRAULIC LEAK ONM STARBOARD TELEMOTOR PRESSURE CONTROL VALVE.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
E20. PROVE SATISFACTORY OPERATION OF SHIP'S EVAPORATORS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E19. MAKE FUNCTIONAL CONTROL KNOB ON #1 BOOST PUMP CONTROLLER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E18. PROVIDE LABELS ON UNMARKED MACHINERY CONTROLLERS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E17. REPLACE/INSTALL COVERS FOR WIRING PORTS ON OVERHEAD LIGHTS IN MACHINERY SPACE AS NEEDED.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E32. PROVIDE SUPPORTS FOR AFT BILGE SUCTION LINE AND STRAINER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E31. REPAIR/REPLACE WIRING TO SHIP'S SERVICE AIR COMPRESSOR CONTROLLER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E30. REPAIR/REPLACE WIRING INTO AFT TURNING GEAR CONTROLLER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E29. INSTALL STOP ON HAND RELIEVING GEAR FOR AUX BOILER TO PREVENT CABLE FROM KINKING AS WHEEL IS BEING LOWERED.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E28. REPAIR/REPLACE AUX BOILER SIGHT GLASSES (THEY ARE LEAKING AT TOP AND BOTTOM SEALS).
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E27. REPAIR EXHAUST GAS LEAK IN STARBOARD ENGINE EXHAUST PIPING LOCATED ON THE EXPANSION JOINT (UPPER LEVEL AUXILLARY BOILER FLAT).
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E26. MAKE REPAIRS TO BOILER EXHAUST STACK AS NEEDED
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Construction/Loadline
Issued 16 December 1990
Resolved
E25. PROPERLY LABEL BALLAST PIPING FLOW CHART IN CONTROL ROOM TO REFLECT CHANGES TO THE TWO FORWARD TALLOW TANKS CONVERTED TO DEDICATED SLOP TANKS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Construction/Loadline
Issued 16 December 1990
Resolved
E33. REPLACE/REPAIR WATER TIGHT DOOR IN PORT TUNNEL AT FRAME 164.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
D5. PROVIDE PROPER DISCHARGE PLUMBING FOR THE CREWS' WASHING MACHINE.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E34. PROVE OPERATION OF THE EMERGENCY FIRE PUMP GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP FOR THE PORT, STARBOARD AND AFT MAIN DIESEL ENGINES.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
CONDUCT TESTING OF MCR "FAILSAFE DESIGN VERIFICATION TEST PROCEDURE" (WITH EXCEPTION OF ITEM 1.4).
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E6. PROVE PROPER OPERATION OF ENGINE ROOM CONTROL BOOTH EMERGENCY LIGHTS OVER CONSOLE AND BETWEEN THE SECOND ROW OF POWER SUPPLY PANELS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E5. WHILE IN ROUTE FROM NORFOLK, VA. TO HOUSTON TEXAS TEST WASTE HEAT ECONOMIZER SAFETY RELIEF VALVE. RECORD LIFT AND SEATING PRESSURES IN OFFICIAL SHIP'S LOG, VALVE TO BE SEALED BY COAST GUARD MARINE INSPECTOR PRIOR TO LEAVING NEXT U.S. PORT.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
E4. PROVE PROPER OPERATION OF THE AUTRONICA ALARM SYSTEM (CONTROL ROOM INDICATOR LIGHTS AND ALARMS; MACHINERY SPACE VISUAL AND AUDIBLE).
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990
Resolved
PROVE PROPER OPERATION OF THE OWS AND OIL CONTENT MONITOR
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
D8. PROVIDE CURRENT ELEVATOR CERTIFICATES.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
D7. REPAIR OR RENEW THE NON FUNCTIONING STOVE ON THE VESSEL'S GALLEY.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990
Resolved
D4. REPAIR OR REMOVE FROM THE VESSEL ALL BROKEN FURNITURE IN THE CREW ACCOMODATION AREAS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E14. REPLACE LIGHT COVERS ON AFT GENERATOR ALARM PANNEL.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E13. REPLACE/REPAIR WIRING AND MOUNT FOR THE REFRIGERATION SOLENOID VALVE LOCATED OUTBOARD OF THE REFRIGERATION COMPRESSORS ON THE REFRIGERATION FLATIN THE MACHINERY SPACE.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E12. REPAIR/REPLACE WIRING AND COVER ON ELECTRICAL PANNEL PORT SIDE OF AFT RAMP.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E11. REPLACE JUNCTION BOX COVER ON JUNCTION BOX FORWARD OF FRAME 164, INBOARD, IN PORT PIPE TUNNEL.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E10. REPAIR/REPLACE AND PROVE SATISFACTORY OF CALL ALARM IN THE FISH ROOM FREEZER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E9. REMOVE/REPAIR EXPOSED WIRING ON OVERHEAD LIGHT ON THE SECOND DECK BY OFFICERS DAY ROOM.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
E8. REPAIR/REPLACE EMERGENCY GENERATOR HIGH JACKET WATER TEMP INDICATOR LIGHT. PROVE PROPER OPERATION OF SAME.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
D12. REPAIR OR REPLACE BROKEN LIGHTS IN THE BOILER FLAT.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Navigation
Issued 16 December 1990
Resolved
D11. PROVIDE UPDATED DEVIATION TABLES FOR THE RADIO DIRECTION FINDER AND THE MAGNETIC COMPASS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Electrical
Issued 16 December 1990
Resolved
D3. PROVIDE GLOBES FOR ALL EXPOSED LIGHT FIXTURES THROUGHOUT THE ENTIRE VESSEL.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 29 August 1989
Resolved
DEMONSTRATE PROPER LIFTING OF THE SAFETY VALVES OF PRESSURE VESSELS: BAL85-80, BAL85-81, BAL85-82.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Electrical
Issued 29 August 1989
Resolved
DEMONSTRATE OPERATION OF THE REFRIGERATION SPACE ALARM SYSTEM AS PER 46CFR113.45.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Lifesaving
Issued 29 August 1989
Resolved
PROVIDE THE FOLLOWING FOR THE STARBOARD LIFEBOAT: TWO HEAVING LINES, TWO SPARE OARLOCKS.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Fire Fighting
Issued 29 August 1989
Resolved
DEMONSTRATE REMOTE SHUTDOWNS: (A) AUX. ENGINE FR SERVICE TK FA1130, (B) REMOTE SUCTION TO DIESEL OIL TRANSFER PUMP, (C) HEAVY OIL PUMP.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Electrical
Issued 29 August 1989
Resolved
CLEAR GROUNDS IN 220 VOLT LIGHTING CIRCUIT.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Electrical
Issued 29 August 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE FORWARD SHIP SERVICE GENERATOR ALARMS AND TRIPS.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Fire Fighting
Issued 29 August 1989
Resolved
PROVE PROPER OPERATION OF THE LOW PRESSURE CO2 DISCHARGE TIMER FOR "C" DECK AFT AND TANK TOP AFT.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Lifesaving
Issued 29 August 1989
Resolved
PROVIDE THE FOLLOWING FOR THE PORT LIFEBOAT: TWO 2 GALLON CORROSION RESISTANT METAL BUCKETS, TWO HEAVING LINES, TWO SPARE OARLOCKS, 20 PACKETS OF FOOD.
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Fire Fighting
Issued 30 August 1988
Resolved
ALL CO2 ALARMS IN ENGINEROOM SHALL BE LABELED "WHEN ALARM SOUNDS-VACATE AT ONCE, CARBON DIOXIDE BEING RELEASED." AS PER 46 CFR 97.37-9.
Condition: Unknown
Due 30 August 1988
Resolved 30 August 1988
Construction/Loadline
Issued 12 August 1988
Resolved
PROVE PROPER OPERATION OF WEATHERTIGHT DOOR ON 03 DECK PORT SIDE LEADING INTO UPPER ENGINEROOM.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
LABEL IN ENGLISH THE CIRCUIT BREAKER DIRECTORIES IN DECKHOUSE CIRCUIT BREAKER PANELS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
REMOVE OR BLANK OUT ALL OBSOLETE CONTROLS ON BRIDGE AND IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988
Resolved
END FOR END PORT AND STARBOARD LIFEBOAT FALLS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Engineering
Issued 12 August 1988
Resolved
TEST SAFETY VALVE ON WASTE HEAT BOILER AND LOG RESULTS. PROVIDE [name withheld] WITH A COPY OF LOG ENTRY.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Engineering
Issued 12 August 1988
Resolved
TEST OVERSPEED TRIP ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988
Resolved
RENEW PELICAN HOOKS ON TRICING PENDANTS ON PORT LIFEBOAT SO AS TO CAUSE EASY RELEASE OF TRICING PENDANTS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Engineering
Issued 12 August 1988
Resolved
CHANGE AUXILIARY BOILER ALARM CIRCUIT TO CONFORM TO 46CFR 63.05-80.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
TEST REVERSE POWER RELAY ON STARBOARD SHAFT DRIVEN GENERATOR.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTS IN CARGO HOLDS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Navigation
Issued 12 August 1988
Resolved
RENEW AND RECALCULATE DEVIATION TABLES FOR RADIO DIRECTION FINDER AND MAGNETIC COMPASS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988
Resolved
LOWER INTO THE WATER, RELEASE, AND EXERCISE STARBOARD LIFEBOAT.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Navigation
Issued 12 August 1988
Resolved
REPLACE LIGHT IN MAGNETIC COMPASS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Navigation
Issued 12 August 1988
Resolved
PROVIDE AND PLACE FOG BELL AND GONG IN PROPER LOCATION.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Construction/Loadline
Issued 12 August 1988
Resolved
FREE UP DOGS ON WEATHERTIGHT DOOR ON MAIN DECK STARBOARD AFT LEADING TO PASSAGEWAY.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Construction/Loadline
Issued 12 August 1988
Resolved
REMOVE UPPER HALF OF DEHUMIDIFIER SHEET METAL DOOR ON "B" DECK AFT, OUTSIDE OF WORKSHOP.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Fire Fighting
Issued 12 August 1988
Resolved
PROVIDE DOCUMENTATION THAT RELIEF VALVES FOR THE LOW PRESSURE FIXED CO2 SYSTEM WERE SERVICED AND TESTED.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Fire Fighting
Issued 12 August 1988
Resolved
LABEL CO2 LIGHTS AND ALARMS IN ENGINEROOM, HYDRAULIC GEAR ROOM AND ALL CARGO TANKS.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988
Resolved
REPAIR ELECTRICAL OUTLET IN RELIEF ENGINEER'S STATEROOM.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Accommodation/Occupational Safety
Issued 12 August 1988
Resolved
PROVE PROPER OPERATION OF TOILET IN THE HOSPITAL.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Unknown
Issued 25 March 1987
Resolved
INSTALL AUTOMATIC NON-RETURN VALVES IN THE BALLAST PUMP OVERBOARD DISCHARGELINES, AS REQUIRED BY 46CFR56.50(B) AND CMDT (G-MTH-2) LETTER 16703/ APPEALS DATED 15SEP86 TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION NOT LATER THAN 31DEC87.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987