BLACK EAGLE

BLACK EAGLE is a 1983 freight ship. The Coast Guard has recorded 79 inspections since 2001, most recently in July 2020, along with 120 deficiencies, 5 operational controls and 8 casualty investigations between 2009 and 2017.

Records from 2001 to 2020. Most recent: inspection, 28 July 2020.

Built
1983
Last inspected
28 July 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8124371 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
369542000 (licence lapsed)
Maury page id
psix-37651

Inspections, by type

…with no type recorded34
Years with a record 19 calendar years (2001–2020)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31041 - Convention (Subpart B), Gross Ton
10556 - Convention (Subpart B), Net Ton
31975 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDJJMMSI 369542000 · cancelled · compulsorily equipped · granted 17 May 2012, cancelled 27 February 2020
WDJJMMSI 369542000 · terminated · compulsorily equipped · granted 4 February 2012, cancelled 17 May 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE DIAMOND Freight Ship · MISLE 248443 · 11 December 2001 · activity 187909CAPE DOMINGO Freight Ship · MISLE 248446 · 11 December 2001 · activity 187909

Inspection history · 79

28 July 2020 Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7018205
30 January 2020 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6895374
6 March 2019 Annual Inspection · MTSA Verification · ACP Periodic Oversight · ACP Additional Oversight – Risk Assessment · Ballast Water Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6629359
19 February 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6627956
13 May 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6429155
12 February 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6352495
8 February 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6352329
25 January 2018 Deficiency Check · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6343378
17 January 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6339087
16 January 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6338035
30 November 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6316306
1 November 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6296337
30 October 2017 Periodic Inspection · Deficiency Check · ACP Periodic Oversight
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6295742
19 October 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6290237
5 August 2017 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6229698
3 August 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6229465
24 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6154700
21 April 2017 Type not recorded
No type recorded · Activities Europe · Activity 6133464
8 March 2017 ISM Oversight · MTSA/ISPS Verification · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6088650
24 February 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6095371
24 February 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6095718
29 January 2017 Type not recorded
No type recorded · Activities Europe · Activity 6079293
12 December 2016 Internal Structural Exam · Drydock Exam · Damage Survey
Physical examination · Activities Europe · Activity 6037247
8 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6037249
8 November 2016 Type not recorded
No type recorded · Activities Europe · Activity 6037259
20 June 2016 Ballast Water Examination · Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5912918
20 June 2016 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5913607
16 June 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5909335
14 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5906905
30 November 2015 Explosive Handling Operation-Military
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5772610
30 November 2015 ACP Periodic Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5790769
29 November 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5772356
12 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5214813
12 August 2015 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5225062
20 August 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4960810
20 August 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4961241
28 June 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4359804
25 June 2012 Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4356315
24 June 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4355416
24 June 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4360222
23 May 2012 MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 4306374
10 January 2012 Internal Structural Exam · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4210546
13 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4207417
13 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4208246
4 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4105492
28 January 2011 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3937852
20 November 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3895440
5 January 2010 Periodic Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3657231
14 January 2009 ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3394618
23 September 2008 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3331190
26 August 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3349626
4 March 2008 MARPOL Annex I Examination · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3310041
13 November 2007 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3097217
27 May 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2946117
20 May 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2936242
13 May 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2932018
11 May 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2946064
30 March 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · ACP COI Oversight · Examination of Repairs · ISM Oversight · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2890291
12 September 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2776747
5 September 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2770474
2 September 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2770337
2 March 2006 ACP Annual Oversight · MARPOL Annex V Examination · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2601995
8 March 2005 ACP Annual Oversight
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2317129
26 May 2004 MTSA/ISPS Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2078501
3 May 2004 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2057698
4 March 2004 Annual Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2011810
4 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1959323
1 October 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1918800
29 September 2003 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1930574
28 July 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1860342
20 July 2003 Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1860090
6 May 2003 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1804385
8 April 2003 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1770100
7 November 2002 Annual Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1700469
3 August 2002 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1663695
22 February 2002 In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1492636
21 February 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1488206
11 December 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 187909
11 December 2001 Hull Examination · Reflagging & Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1479144

Deficiency record · 120

Electrical › Electrical Distribution System (service) › Wiring
Issued 29 January 2018 Resolved
Found improper wiring on newly installed laundry machinery i.e. non marine grade plug extensions/pigtails. Ships force corrected same day by hard wiring machinery to junction boxes.
Condition: Improper Installation
Due 29 January 2018
Resolved 29 January 2018
Lifesaving › Lifeboat › Propulsion Transmission
Issued 31 October 2017 Resolved
Shifter linkage to the transmission has been temporarily repaired; make permanent repairs when parts are received (port life boat).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Fire Fighting › Fire Main › Condition
Issued 31 October 2017 Resolved
Temporary repairs to firemain at station #4 are to be made permanent at earliest opportunity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Fire Fighting › Means of Escape › Doorways
Issued 31 October 2017 Resolved
Door frame for emergency escape is deteriorated and holed iwo door #312, make repairs as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Stability › Weathertight Integrity › General
Issued 31 October 2017 Resolved
The window in the port ladderwell on Deck 3 is shattered, replace the glass.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 31 October 2017 Resolved
Lower and operate the stbd life boat (IAW FY18 ACP message and 3 month SOLAS requirement).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 October 2017 Resolved
Temporary repairs to hydraulic hoses on the Port & Stbd steering pumps are to be made permanent at earliest opportunity.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 October 2017 Resolved
Ensure annual service is carried out on all portable fire extinguishers; noted approx. 06 w/o service tags (stations #71, 73, 38, 53; extinguishers #38, 71)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 3 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 31 October 2017 Resolved
There are numerous broken light fixture covers in the engine room; replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 30 January 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 31 October 2017 Resolved
In emergency locker #2, vent was found blocked with rag.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Removed by crew members.
Electrical › Lighting (service) › Lighting Fixture
Issued 31 October 2017 Resolved
Light in ladderwell on Deck 2 IVO hospital space attached with bailing wire and not sealing with fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Cover reattached and sealed properly.
Construction/Loadline › Structures › Door
Issued 31 October 2017 Resolved
Door to ventilation room found wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Replaced w/ door from a space in engine room. Class approved the replacement.
Electrical › Electrical Distribution System (service) › Switch
Issued 31 October 2017 Resolved
Exposed wiring was identified in switch near door in ventilation room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crew replaced switches.
Lifesaving › Lifeboat › Fire Protection (general)
Issued 31 October 2017 Resolved
Diesel fuel present in fwd bilge of stbd lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crew removed diesel from bilge with sorbent pads.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 31 October 2017 Resolved
Embarkation light at STBD life boat has broken bracket and is ratchet strapped to handrail rendering it unable to light embarkation area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crew replaced bracket and light fixture.
Construction/Loadline › Structures › Ventilators
Issued 31 October 2017 Resolved
Vent pipe to engine room cofferdam was wasted and moved easily by hand.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crewmembers replaced vent piping.
Construction/Loadline › Structures › Ventilators
Issued 31 October 2017 Resolved
Ventilation covers #1, 9, and 10 on cargo deck failed to close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crewmembers made adjustments to closure devices ensuring complete closure of covers.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 October 2017 Resolved
Cables from MCTs on cargo deck each had one cable cut, leaving an approximately 12 inch pigtail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Cables from reefer system removed from vsl previously. Cut pigtails back to firestop.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2017 Resolved
Cable penetration has new cables installed, fire stop not replaced after addition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crewmembers replaced fire stop.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 31 October 2017 Resolved
Mold found on overhead in storeroom 235.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Resolution: Crewmembers removed/cleaned panels from drop ceiling.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 30 October 2017 Resolved
The cable penetration in the deck between the engine room and the ECR IWO the alarm panel is not properly sealed with fire stop; repair with an approved type of sealant.
Due 30 November 2017
Resolved 31 October 2017
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 30 October 2017 Resolved
The cable penetration in the engine room bulkhead above the port ladder well door is not properly sealed; make repairs with an approved type of sealant.
Due 30 November 2017
Resolved 31 October 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 30 October 2017 Resolved
The emergency escape door in the ECR does not properly close or seal; make repairs as necessary.
Due 30 November 2017
Resolved 31 October 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 30 October 2017 Resolved
The wiring for the forward flood light in the engine room is hanging loose from the fixture; properly secure the wirng to the light inside the fixture.
Due 30 November 2017
Resolved 31 October 2017
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 30 October 2017 Resolved
The #3 generator engine is leaking fuel in two locations associated with the fuel rack; make repairs as necessary.
Due 30 November 2017
Resolved 31 October 2017
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 March 2017 Resolved
The OWS was not operating properly. C/E advised the OWS was found not working after leaving shipyard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Part was installed and tested with 3rd party in attendance was CG MI and Class Surveyor
Engineering › Pressure Vessel › Weld
Issued 8 March 2017 Resolved
C/E nor Master could provide evidence that the boilers were inspected in compliance with 46 CFR 61.05-10.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 17 March 2017
Resolution: Detailed class report was provided.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 8 March 2017 Resolved
Foam analysis failed. Vessel scheduled for new foam to be onboard within a week.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: New foam was provided and cert is on board.
Fire Fighting › Fire Hydrants › Condition
Issued 8 March 2017 Resolved
Fire station 43 and 45 valve failed.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 17 March 2017
Resolution: Valves were blued and passed inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2017 Resolved
aft bulkhead in generator room had open wire penetrations and broken light guard, missing packing.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 13 March 2017
Resolution: The wire penetration in the generator room was filled. The light guard in the same space was also repaired.
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2017 Resolved
Remove or properly dead end cable from old aft deck winch motor.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 13 March 2017
Resolution: Wire on aft deck where the winch motor is located was removed.
Engineering › Steering Gear System › Valve
Issued 8 March 2017 Resolved
leaking #1 steering control valve needs to be repaired.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 13 March 2017
Resolution: The number one steering control valve leak was repaired.
Fire Fighting › Fire Hydrants › Condition
Issued 8 March 2017 Resolved
Provide spanner wrench at fire station located aft of navigation bridge. Hose is not connected to fire station and nozzle is not connected to hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 13 March 2017
Resolution: The fire station outside of the pilot station was fitted with a spanner wrench.
Communications › Visual Communication › Signalling Lamp
Issued 8 March 2017 Resolved
Provide back up power for signaling lamp. The battery and battery box provided could not connect to signaling lamp.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 13 March 2017
Resolution: The signaling lamp was provided was a power source.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2017 Resolved
Vessel has numerous lights with broken or missing protective covers. Provide covers for light fixtures.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 24 May 2017
Resolution: Deficiency was made a condition of class
Electrical › Electric Supply System (service) › Cable
Issued 8 March 2017 Resolved
Remove or properly dead end cables located in gyro room aft bulkhead.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 13 March 2017
Resolution: The conduit in the gyro room was found to be coaxial cable. It was trimmed, capped, and bundled with the other cables.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 8 March 2017 Resolved
Numerous portable fire extinguishers are located at wrong fire stations. Mark portable fire extinguishers in accordance with approved fire/safety plan
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 13 March 2017
Resolution: Portable fire extinguishers throughout the vessel were returned to their assigned locations so that the extinguisher numbers matched the location labels and coincided with the fire plan.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 March 2017 Resolved
provide protective cover over rotating belt for A/C motor. Guard is not in place and motor is not tagged out and is in operation.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 13 March 2017
Resolution: The machinery guards for the a/c motor were replaced along the belt and shaft
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 March 2017 Resolved
prove proper opration of emergency light located in the room known as the ping pong room.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 13 March 2017
Resolution: The emergency light in the ping pong room was repaired.
Construction/Loadline › Structures › Door
Issued 8 March 2017 Resolved
Make proper adjustements to watertight door located in "bosun" room starboard side. Door will not dog enough to permit good seal.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Door closes and makes appropriate seal.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 8 March 2017 Resolved
Repair or replace two gauges in foam room
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 13 March 2017
Resolution: Unreadable gauges in foam room were replaced with new gauges.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 8 March 2017 Resolved
Repair spare portable fire extinguisher with hose/cone that is not attached.
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 13 March 2017
Resolution: cone was replaced on the hose of the spare portable fire extinguisher in the foam room.
Lifesaving › Inflatable Liferafts › Markings
Issued 8 March 2017 Resolved
The information card tube is not attached to the raft.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 13 March 2017
Resolution: Information card on the #5 (Starboard aft) life raft was replaced.
Lifesaving › Lifebuoys › Stowage
Issued 8 March 2017 Resolved
Provide IMO symbols for various life buoys around vessel as well as liferafts.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 13 March 2017
Resolution: IMO symbols for life rafts and life rings replaced.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Trunking
Issued 8 March 2017 Resolved
Several exhaust trunks are wasted and have no ablity to be sealed off to prevent downflooding.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Repairs were made to affected vents.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 8 March 2017 Resolved
4 cargo hold sprinkler pipes were found to be wasted and holed. Make permanent repairs and test piping.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 17 March 2017
Resolution: Pipes were permanently repaired and satisfactory.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 8 March 2017 Resolved
Flexible hoses for cargo hold sprinkler systems appear to be buckled. Hoses are covered with a metal sheeve. Prove hoses are in good order.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 17 March 2017
Resolution: Hose was made visible for inspection and no deformity observed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 March 2017 Resolved
Make bulkhead cable penetrations in E-gen and fwd focsle/paint locker room appropriate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2017
Resolution: Appropriate packing material was in place.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 March 2017 Resolved
Provide tool to break glass for CO2 operating station located outside fwd paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 13 March 2017
Resolution: CO2 actuator glass breaking tool replaced for the forward paint locker.
Fire Fighting › Fire Main › Material
Issued 8 March 2017 Resolved
Make permanent repairs to two pin holes in fire main piping located in focsle
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Affected fire main piping was replaced.
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 8 March 2017 Resolved
Provide required vent fan boots to two fans located in fan room port side. Fan ducting is not connected and only circulating the air in the fan room
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 13 March 2017
Resolution: Boots for vents replaced in fan room.
Stability › Incline Test › General
Issued 8 March 2017 Resolved
Provide evidence from Class that the removal of the aft crane did not impact vessel stability.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Class provided evidence that stability was not affected by relocation of aft crane to #2 crane location.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 March 2017 Resolved
Make permanent repairs to cargo hold 3 hatch cover in middle of port side where hatch splits.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Wasted hole was properly welded up.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 8 March 2017 Resolved
Due to number and nature of deficiencies noted, class to conduct an external SMC audit.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Class conducted SMC audit
Deck/Cargo › Cargo Transfer (solid) › General
Issued 8 March 2017 Resolved
Due to #4 crane cable being replaced from damage to previous, class to attend and certify #4 crane.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2017
Resolved 17 March 2017
Resolution: Class provided report that crane was satisfactory.
Deck/Cargo › Cargo Stowage › General
Issued 12 December 2016 Resolved
Weathertight hatches to #3 fwd center and #3 port fwd are damaged and need to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 April 2017
Resolution: hatches were renewed
Deck/Cargo › Cargo Transfer (solid) › General
Issued 12 December 2016 Resolved
#2 Cargo Crane is damaged beyond repair. If vsl replaces, crane must be weight tested IAW Class standards and base of crane must be NDT in prescense of class surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 April 2017
Resolution: class approved the replacement of the crane
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 December 2016 Resolved
Bulkhead of #2 Starboard Ballast Tank is leaking into #1 Starboard Ballast Tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 April 2017
Resolution: Class conducted survey on 30JAN2017
Construction/Loadline › Structures › Superstructure
Issued 12 December 2016 Resolved
Bulwark in close proximity to #2 Cargo Crane is damaged and needs to be cropped and renewed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 April 2017
Resolution: bulwark was repaired.
Construction/Loadline › Structures › End Bulkhead
Issued 12 December 2016 Resolved
Overhead section of #4 Double bottom ballast tank is sagging. Required to guage and crop and renew as needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 April 2017
Resolution: Class conducted survey on 30JAN2017
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 November 2016 Resolved
Provide a damage survey for the hatch covers and attest to the sea worthiness of the vessel.
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 10 November 2016
Resolution: Vessel provided a class report stating the vessel was safe to sail to Durban, SA.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 12 August 2015 Resolved
Prior to vessel departure main engine emergency control shall properly operate to the satisfaction of the attending class society. Local controls from main engine control are not staying in place.
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 12 August 2015
Resolution: Chief engineer fixed problem which was a emergency solenoid valve was not adjusted properly.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 August 2015 Resolved
Update fuel switch over procedure to ensure peoper understanding of filters when switching from MGO to Hfo.
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 12 August 2015
Resolution: Captain of the vessel updated procedures.
Engineering › Steering Gear System › Valve
Issued 25 June 2012 Resolved
Steering causality, "lock out," due to a partially stuck valve which prevented rudder movement for about 1 minute. Prove proper operation of steering system to the satisfaction of class society and the USCG prior to departure from the Sector San [name withheld].
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2012
Resolution: Item cleared based on witnessing proper operation of the steering system.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 25 June 2012 Resolved
The main propulsion (Slow Speed Diesel) had failed to respond because the pneumatic brake valve had stuck while going from ahead to astern.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2012
Resolution: Item cleared based on witnessing proper operation of the main propulsion system system.
Lifesaving › Lifeboat › Markings
Issued 28 January 2011 Resolved
Retro reflective tape on P/S lifeboat canopies was worn; renew. Also, need to add life boat number to identification seen from above.
Condition: Improper/Lack of Maintenance
Due 28 January 2011
Resolved 28 January 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2010 Resolved
Found port lifeboat winch control box hanging by wires and conduit hanging by wires - repair as original.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2010 Resolved
Found improper splice in emergency batteries on 06 deck aft - repair as original.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Construction/Loadline › Structures › Superstructure
Issued 5 January 2010 Resolved
Service door to #2 Emergency Locker - currently the door sticks in the closed position severely and cannot be opened in an emergency.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Fire Fighting › Fire Hydrants › Condition
Issued 5 January 2010 Resolved
Repair or replace fire station #11 wye-gate.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Lifesaving › Lifeboat › View (at steering position)
Issued 5 January 2010 Resolved
Life boat viewing ports (port and stbd boats) are broken - repair as original.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Operations/Management › Drills/Instruction › Fire
Issued 5 January 2010 Resolved
Conduct Fire, Abandon Ship, and Security drills prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2010
Resolution: Conducted successful fire, abandon ship, and security drills.
Fire Fighting › Means of Escape › Blocked
Issued 5 January 2010 Resolved
Found numerous emergency escape doors and security doors with broken/damaged hinges, locking devices, and handles. Repair/replace doors and demonstrate proper operation.
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Verrified appropriate repairs were made to all emergency exit doors and security doors. Tested all doors, crew demonstrated proper operation.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 January 2010 Resolved
Stbd side gangway winch control is hanging by wires - remount as original.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Rcvd email notification from DNV surveyor of completion.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 30 March 2007 Resolved
Hydro test all CO2 fire extinguishers and breathing air bottles at a DOT approved facility after returning to the United States.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Resolution: Bottles were serviced at DOT facility in the USA.
Lifesaving › Lifebuoys › Stowage
Issued 30 March 2007 Resolved
Make permanent repairs and properly mark life buoy hangers as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 15 April 2007
Resolution: Hangers were replaced with new hangers and marked.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 March 2007 Resolved
Make permanent repairs to AC fan room door. Door was changed during shipyard availability to a non-U. S. Coast Guard approved type door for an "A-Class boundary.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2007
Resolved 13 November 2007
Resolution: CG approved A-Class door has been delivered to the vessel and installed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 30 March 2007 Resolved
Provide copies of 2007 tide and tidal current tables. Vessel must print out and have on hand all applicable tide and tidal current information from an electronic source until tables are onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Resolution: Tables provided
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 March 2007 Resolved
Submit non-tank vessel response plan to US Coast Guard for approval.
Action required: 705 - Other - as specified
Resolved 13 November 2007
Resolution: Plan has been submitted to USCG
Engineering › Pressure Vessel › Relief Valve
Issued 30 March 2007 Resolved
Provide evidence that the Pressure Relief Valves on all pressure vessels were accepted during reflagging or replace with ASME approved valves.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Resolution: Valves changed with onboard spares.
Fire Fighting › Fire Main › Valves
Issued 30 March 2007 Resolved
Make permanent repair to fire station #45 fire plug to ensure valve does not leak by.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Resolution: Valve was repaired.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 30 March 2007 Resolved
Install hard piped L/O system for adding L/O to the ship service generators. Utilize hose for oil service listed in SAE standard J-1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Resolution: Adequate piping system installed.
Documentation › Markings/Placards › Warning Signs
Issued 2 March 2006 Resolved
Labeling throughout the vessel, including emergency/safety equipment, is labeled in French. The labeling must be changed to the working language of the vessel - English. Notified DNV Singapore of this requirement for follow-up.
Due 2 March 2006
Resolved 2 March 2006
Lifesaving › Buoyant Apparatus
Issued 7 November 2002 Resolved
Change water light lanyard splice, on stbd ring buoy, from grab line to girth of buoy.
Condition: Placed in Improper Service
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Accommodation/Occupational Safety › Ventilation
Issued 7 November 2002 Resolved
Prove proper operation of emergency gear locker vent closure.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficinecy documented by class for action.
Engineering › Compressed Air System (control) › Piping
Issued 7 November 2002 Resolved
Crop and renew wasted service air piping IWO stbd side emergency gear locker.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Stability › Watertight Integrity
Issued 7 November 2002 Resolved
Install missing dog to stbd crew boy passageway WTD.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Stability › Watertight Integrity
Issued 7 November 2002 Resolved
Port light on aft bulkhead of foc'sle does not close properly.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Accommodation/Occupational Safety › Ventilation
Issued 7 November 2002 Resolved
Latch is missing to vent no. 57, aft bulkhead of foc'sle.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Accommodation/Occupational Safety › Ventilation
Issued 7 November 2002 Resolved
Forward vents no. 3 and 7 frozen.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Stability › Watertight Integrity
Issued 7 November 2002 Resolved
Main deck WTD to fwd duck keel escape frozen.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficinecy documented by class for action.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 November 2002 Resolved
Numerous main deck lighting inoperative...mostly port side.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 November 2002 Resolved
Stern light lens covered with paint and discolored/faded.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 November 2002 Resolved
Scupper grating IWO port lifeboat operating station wasted/missing.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 November 2002 Resolved
Conduct annual servicing of fixed CO2 system.
Condition: Improper/Lack of Maintenance
Due 7 February 2003
Resolved 5 February 2003
Resolution: Servicing conducted.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 7 November 2002 Resolved
Securing bracket to stbd lifeboat dogging wrench wasted.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Accommodation/Occupational Safety › Ventilation
Issued 7 November 2002 Resolved
Vent ducting in CO2 room wasted. Fan has excessive vibration.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Stability › Unintentional Flooding
Issued 7 November 2002 Resolved
Sounding tube anti flooding devices in engineroom inoperable.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Communications › Audible Communications › SPD (Other)
Issued 7 November 2002 Resolved
Directory to emergency generator sound powered phone missing.
Condition: Improper/Lack of Maintenance
Due 7 November 2002
Resolved 8 November 2002
Resolution: Deficiency documented by class for action.
Engineering
Issued 3 August 2002 Resolved
An Automation test procedure is to be developed using the gluideline of USCG NVIC 1-69.
Action required: 705 - Other - as specified
Due 31 August 2003
Resolved 28 July 2003
Resolution: Automation Test Procedure received, reviewed, and approved.
Lifesaving › Launching Appliances
Issued 11 December 2001 Resolved
Renew wasted port lifeboat gripe. LEGACY COMPONENT DESC: Lines
Condition: Improper/Lack of Maintenance
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Lifesaving › Lifeboat
Issued 11 December 2001 Resolved
Affix lifeboat data plates to port and starboard lifeboats. LEGACY COMPONENT DESC: Markings
Condition: Improper Installation
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Fire Fighting › International Shore Connection
Issued 11 December 2001 Resolved
Provide on board International shore connection.
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing
Issued 11 December 2001 Resolved
Provide on board EAP Information. LEGACY COMPONENT DESC: EAP Display Requirements
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Fire Fighting › Water Fog Applicators
Issued 11 December 2001 Resolved
Provide on board <6 foot applicators for each fire hose station in machinery spaces. LEGACY COMPONENT DESC: Type
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected
Fire Fighting › Fire Hoses
Issued 11 December 2001 Resolved
Relocate fire hose station racks on glley deck and upper car deck. LEGACY COMPONENT DESC: Location
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected
Documentation › Safety/Response Plans/Programs
Issued 11 December 2001 Resolved
Place on board final approved Fire and Safety plan. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Fire Fighting › Fire Hydrants
Issued 11 December 2001 Resolved
Label all Fire Hose stations iaw fire control plan and 46CFR97.37 as ref. LEGACY COMPONENT DESC: Location/Position
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Communications › Alarms/Indicators
Issued 11 December 2001 Resolved
Label all General alarms and CO2 alarms LEGACY COMPONENT DESC: General Alarm
Condition: Placed in Improper Service
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Electrical › Lighting (emergency)
Issued 11 December 2001 Resolved
Label all Emergency lights iaw 46 CFR 97.37.
Condition: Unknown
Due 11 January 2002
Resolved 11 December 2001
Resolution: Corrected.
Communications › Alarms/Indicators
Issued 11 December 2001 Resolved
Prove proper operation of (2) general alarm bells in pipe tunnels. LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected
Stability
Issued 11 December 2001 Resolved
Provide final approved Damage Stability criteria and Stability Letter.
Condition: Unknown
Due 11 January 2002
Resolved 11 January 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 11 December 2001 Resolved
Galley deck Distribution panel requires blank over open breaker LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Corrected
Navigation › Emergency Steering
Issued 11 December 2001 Resolved
Emergency Steering instructions not posted. LEGACY COMPONENT DESC: Communications to Emergency Steering
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 11 December 2001 Resolved
Ring buoys and lights not properly mounted. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Due 11 December 2001
Resolved 11 December 2001
Resolution: Corrected.
Engineering › Lubricating Oil Service System
Issued 11 December 2001 Resolved
Remove hold back devices on nozzles for Diesel Generator prime mover L/O fill hoses (3). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 11 December 2001
Resolved 11 December 2001
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 December 2001 Resolved
Coupling guard for swimming pool pump missing. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Corrected.
Construction/Loadline › Hull
Issued 11 December 2001 Resolved
#4 WBT Port side, Between Fr 72-112: Swash blkd about 600mm above bottom, plating and stiffeners were wasted. LEGACY COMPONENT DESC: Stiffener
Due 11 December 2001
Resolved 11 December 2001
Resolution: Cropped andInserted 24'''' x 8'''' plate.
Construction/Loadline › Hull › Stiffener
Issued 11 December 2001 Resolved
#4 WBT stbd side, Fr 72-112: Swash Blkd about 600mm above the bottom, the plating and stiffeners were wasted.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Cropped and Inserted 16'' x 7'' plate.
Construction/Loadline › Hull › Bottom Plating
Issued 11 December 2001 Resolved
#3 WBT DB, Stbd, Fr 112-152: at frame 121, the third bay from starboard side towards the center, bottom of floor plate buckled.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Cropped and Inserted 5'' x 2.5" plate.

Casualty record · 8

18 October 2009Routine · role: Involved in a Marine Casualty · activity 3801478
13 December 2011Routine · role: Involved in a Marine Casualty · activity 4208246
24 June 2012Routine · role: Involved in a Marine Casualty · activity 4360222
8 January 2014Routine · role: Acknowledged Pollution Source · activity 4780205
12 August 2015Routine · role: Involved in a Marine Casualty · activity 5214813
8 November 2016Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6037259
29 January 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6079293
21 April 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6133464
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.