Records from 1985 to 2012. Most recent: inspection, 17 January 2012.
Inspection history · 60
17 January 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4225693
7 January 2012
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4220310
3 January 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217855
3 January 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217874
5 July 2011
Ballast Water Examination · Deficiency Check · ISPS III Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4069423
5 July 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4069427
1 July 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4064535
3 January 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3919352
29 October 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3880764
24 September 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3856165
24 April 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3458443
12 December 2007
MARPOL Annex I Examination · PII Safety Exam · Deficiency Check · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3111779
19 April 2007
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2910307
2 October 2006
Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791145
2 July 2006
ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2697263
7 June 2006
PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2672204
6 December 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2544817
19 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2468579
10 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2458877
29 July 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2443939
25 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2402769
25 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2405575
18 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2295254
16 February 2005
Random ISPS/MTSA/PSC · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2293493
4 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2269465
4 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307337
15 November 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2241283
11 February 2004
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2004972
15 May 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1794342
1 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1712941
30 October 2002
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1699419
29 May 2002
Ballast Water Examination · Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1623399
28 May 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1621631
19 February 2002
Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1487214
17 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290078
13 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290031
16 September 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 282232
11 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273583
23 June 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 429909
31 December 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 423946
16 October 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 421439
8 October 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 421458
30 December 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 411200
13 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399372
12 September 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 395232
22 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 387119
18 September 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 489838
17 September 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 97988
30 May 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 378822
14 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 375204
22 April 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 357744
16 December 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 355161
1 June 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 351090
24 October 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346573
11 October 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 339739
9 May 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 476434
18 October 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 333169
3 October 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 325961
11 September 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 318307
17 March 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300878
Lifesaving › Launching Appliances › Release Mechanism
Issued 7 January 2012
Resolved
0635 - Lifesaving Appliances- All lifesaving appliances shall be in working order and ready for immediate use. Dead-man brake on port lifeboat lowering mechanism does not function properly. The brake lever sticks in the "up" position when released by operator, allowing the life boat to continue lowering. Provide class report attesting to proper operation of port and stbd lowering mechanisms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2012
Resolved 15 January 2012
Resolution: Received, reviewed, and accepted class report stating deficiency has been rectified. Class report states that surveyor attended vessel along with technician from davit manufacturer; Lowering/raising device on both lifeboats was deemed fully operational.
Construction/Loadline › Structures › Ventilators
Issued 5 July 2011
Resolved
1275-The floats on the following air vents were missing, damaged, or broken. DBT 5P, TST 5P, TST 4P, TST 2P, DBT 1P, DBT 1S, TST 2S. Most Included forward and aft vents. ICLL 20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Construction/Loadline › Structures › Door
Issued 5 July 2011
Resolved
1270-Both entrance doors leading into the forward Bos'n store are not weathertight. ICLL 12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Construction/Loadline › Structures › Air Pipe
Issued 5 July 2011
Resolved
1275-Air pipe port side to forecastle holed. ICLL 20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 July 2011
Resolved
0900-Main deck electrical line wasted throughout and patched. Electrical wire/conduit line leading into hatch at cargo hold #4P wasted. Solas 74 (09 cons.)/45
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 5 July 2011
Resolved
1299-Heavy weather line/cable for crew safety is missing. ICLL 66 I/25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 July 2011
Resolved
0320-Vent ducting in deck store room aft starboard side is holed, also power vent for steering inspection plate is not secured. Both will allow air to enter the space in case of a fire. SOLAS 74 II-2/25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 July 2011
Resolved
1499-HFO service tank 10m^3 has been over-filled. Causing oil to saturate insulation, which may become a fire hazard. In addition steam pipe has been repaired by ships crew. Solas 74 II-2/54
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 July 2011
Resolved
1410-Ballast suction line, ballast overboard discharge line, and ballast supply line were patched. In addition there is a patch on the OWS bilge pump and two patches on the suction line. No reports have been made or sent to the company as per ships SMS. Solas 09 IX/3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 5 July 2011
Resolved
1330-Starboard aft mooring winch is leaking hydraulic fluid. SOLAS 74 II-I/23
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Construction/Loadline › Structures › Superstructure
Issued 5 July 2011
Resolved
1299-Crew has installed an air line, which leads into the forward Bos'n store . No means have been installed to cover the air pipe to prevent the passage of flame, smoke or sea water. ICLL 66 A.1/25
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Deck/Cargo › Cargo Stowage › General
Issued 5 July 2011
Resolved
1199-Hatch cover controls for starboard crane is leaking hydraulic fluid. SOLAS 74 II-I/12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 July 2011
Resolved
0999-Anchor guard for starboard anchor was damaged during mooring. ICLL 25
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2011
Resolved
0330-Crew has modified the gray and black water system, so that all gray water is sent to the APT. No approval from class. ICLL 15
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Lifesaving › Lifeboat Equipment › Tools (engine)
Issued 5 July 2011
Resolved
0600-Before the ship leaves port all life-saving appliances shall be in working order and ready for immediate use. Port and starboard lifeboat embarcation ladders are attached inproperly, making the ladder 1m shorter. Also port and starboard lifeboats canopy support bars and stantions are wasted and innoperable. Port lifeboat is missing swivel for the sea anchor. SOLAS 74(09) III/20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 5 July 2011
Resolved
0620-Before the ship leaves port all life saving appliances shall be ready for immediate use. Port and starboard liferafts have shipping bands still attached. SOLAS 74(09) III/20
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 July 2011
Resolved
2035-The vessel is to maintain an up to date fire control plan. The vessel was found to have modified multiple spaces to serve other than their original purpose without updating the fire control plan to reflect the changes. SOLAS 74 II-2/4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 5 July 2011
Resolved
0610-Before the ship leaves port all life saving appliances shall be in working order. Starboard lifeboat was unable to be lowered, also crew is using a chainfall in order to lower it.SOLAS 74(09) III/20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 5 July 2011
Resolved
0710-The emergency fire pump shall be capable of supplying two jets of water to the satsfaction of the admin and ready for immediate use. The emergency fire pump is not able to take suction and is therefore inoperable. SOLAS 74 II-2/52
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 5 July 2011
Resolved
0955-The pilott ladder shall be efficient for the purpose of enabling safe enbarkation and desenbarkation and the four lower steps shall be made of rubber with addequate strngth and fittness. Both pilot ladders on board have wasted rubber steps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Engineering › Bilge Water Management System › Piping
Issued 5 July 2011
Resolved
1440-The sounding pipe to bilge tank has been modified. Approximately 1ft. from the lower flang, there is a weld which appears to be tampering with the OWS system.SOLAS 74(09) IX/3/5
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 5 July 2011
Resolved
0710-General vessel arrangement plan shall clearly indicate class A and B divisions. The fire control plan indicates that a 'B-0' class door shall be located between the passageway and the crew changing room that leads to the engine room. SOLAS 74 II-2/4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Documentation › Logs/Records › Oil Record Book
Issued 5 July 2011
Resolved
2199-The oil record book shall be filled out in accordance with the requirements as per MARPOL annex 1. Separate operations are not being signed and dated properly. MARPOL A.6/17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 5 July 2011
Resolved
2510-The company shall provide procedures for ensuring safe operation of ship and protection of the environment. There are no fuel changeover procedures onboard that are authorized by the company. In addition the fuel changeover procedure is not being recorded as per MARPOL annex VI/14(6). ISM 1.4.3. MARPOL annex VI/17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 5 July 2011
Resolved
0710-Vessels shall have divisions constructed as to be capable of preventing the passage of smoke and flame. Door and window to engine control room have cracks in the corners from 3 to 10 cm in length. In addition there is a hole in the bulkhead above the door leading into the engine room. SOLAS 74 II-2/3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 July 2011
Resolved
0715-Maintenance, testing and inspection shall be carried out as per organizational guidelines for fire detection. The crew is testing the fire detectors by setting fire to a rag and holding it under the detector. SOLAS 74 II-2/2.2.3.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 5 July 2011
Resolved
The vessel is to carry a training manual complying with regulation 35 of chapter 3 of solas. The life saving manual onboard was found to lack a record of changes or an accurate record of information contained within the manual, making it immposible to verify compliance with applicable regulations. SOLAS 74(09) III/35.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Operations/Management › Pollution › Control of Garbage
Issued 5 July 2011
Resolved
2120-The vessel shall carry a garbage management plan which the crew shall follow. The vessel has not integrated the garbage placard into the garbage management plan. In addition food waste, paper, dunnage and plastics are being mixed in waste receptacles throughout the vessel. Garbage log is not being properly maintained in regards to incinerator. MARPOL V/9
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 5 July 2011
Resolved
0330-Sewage treatment plant is not being maintained as per the manufacturers requirements. Daily, weekly, monthly, semi-annual and annual tests and inspections have not been carried out. In addition a chlorine test kit must be provided. 33CFR159.151(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2011
Resolved 8 July 2011
Resolution: Deficiencies cleared based on Class report.
Operations/Management › Drills/Instruction › Fire
Issued 24 April 2009
Resolved
2020- Crew failed to demonstrate proficiency in Fire Fighting drills. Crew lacks familiarity with equipment and shipboard procedures. A. Fire team unable to access the house and effected space due to lack of keys. B. Fire team unable to extinguish fire due to insufficient length of fire hose. 17 b/c SOLAS-04 -II/2-15
purpose of the Browsing
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Returned to the vessel and witnessed Satisfactory Fire Drill.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 April 2009
Resolved
2025- Crew failed to demonstrate proficiency during two Abandoned Ship drills. Crew lacks familiarity with equipment and shipboard procedures. Crew unfamiliar with the usage and purpose of Browsing Tackle and Tricing Pendants. Drill not conducted IAW the SOLAS Training Manual and Posted Instructions at Embarkation Station. SOLAS-04 III/20 17 b/c.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Returned to the vessel and witnessed Satisfactory Abandon Ship Drill.
Fire Fighting › Fire Hoses › Connections
Issued 24 April 2009
Resolved
0730- Multiple fire hoses in the house are not fitted with the proper couplings. Female hose coupling and fire hydrant threads are dissimilar in size and type, resulting in a lack of adequate fire fighting capability within the house. SOLAS-74 II-2/5 17a/b
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Hoses were changed out and satisfactory pressure test was witnessed by Class Surveyor.
Lifesaving › Lifeboat Equipment › Thermal Protective Aid
Issued 24 April 2009
Resolved
0610- Port and Stbd Lifeboat Canopy's are missing retro reflective material. Port Lifeboat is rigging for the sail. Stbd Lifeboat F/O supply and return lines are leaking. SOLAS-74 III/20 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Rigging was found and witnessed by Class Surveyor.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 April 2009
Resolved
0710- A/0 Bulkhead in ECR at both entrance doors and viewing window has cracks in it, compromising the integrity of the fire boundary. SOLAS-74 I/11 17a/b
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Cracks were drill stopped ground out and welded as witnessed by Class Surveyor.
Construction/Loadline › Structures › Air Pipe
Issued 24 April 2009
Resolved
1275- Aft peak tank vent pipe is pitted, hole and leaking into the chemical storage locker in the steering flat, creating a potential stability issue. ICLL 20 17a/b
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Pipe was renewed as witnessed by Class Surveyor.
Construction/Loadline › Structures › Door
Issued 24 April 2009
Resolved
1270- Numerous doors leading from the accommodations to the weather deck are wasted, worn and do not close and seal properly. This could lead to the ingress of water and in the event of a fire, allow oxygen into the house. ICLL 12, 17a/b
Action required: 17 - Rectify deficiencies prior to departure
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Condition of Class issued for item to be rectified NLT 25MAY2009.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 24 April 2009
Resolved
0199- Ballast Water Management - Record keeping for sediment and training is not being recorded in accordance with the plan. 70a/b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 April 2009
Resolved 25 April 2009
Resolution: Deficiency cleared based on receipt of BV Class report #PTLO/2009/J0014, dated 25 APR2009. Master advised to complete records of training and sediment management as noted by Class Surveyor.
Engineering › Bilge Water Management System › Piping
Issued 19 April 2007
Resolved
#2 fire and general service pump has 2 temporary patches on discharge pipe, just aft of the pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 14 December 2007
Resolution: Received class report attesting to satisfactory repair.
Engineering › Lubricating Oil Service System › Pump
Issued 19 April 2007
Resolved
#1 lube oil pump section pipe for the main engine has a temporary patch with a minor leak on the drain line
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 14 December 2007
Resolution: Received class report via fax attesting to satisfactory repair.
Engineering › Lubricating Oil Service System › Pump
Issued 19 April 2007
Resolved
#2 lube oil pump has minor leak that the flange between the valve and the filter on the section side of the pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 14 December 2007
Resolution: Received class report via fax attesting to satisfactory repair.
Engineering › Pressure Vessel › Piping
Issued 2 October 2006
Resolved
The high pressure double jacket fuel line covers on the No. 5 and No. 6 cylinders were worn and holed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 5 October 2006
Resolution: Received class report from BV stating deficiency has been rectified.
Engineering › Pressure Vessel › Piping
Issued 2 October 2006
Resolved
The main engine high pressure double jacket fuel line covers were not fitted properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2006
Resolved 5 October 2006
Resolution: Received class report from BV stating deficiency has been rectified.
Electrical › Electric Generation Source (service) › Generator
Issued 7 June 2006
Resolved
The #1 generator forward pedastal bearing oil seals are smoking and leaking oil excessively which is also causing the shaft to sling oil onto the heated surfaces of the #2 generator. Additionally, the inside of the generator casing appears to be soaked in oil. The generator is to be cleaned and inspected and all surrounding machinery and equipment is wiped down.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 17 June 2006
Resolution: Received class report from BV clearing deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 7 June 2006
Resolved
The #2 generator forward pedestal bearing oil seals are smoking and leaking oil excessively which is also causing the shaft to sling the oil onto the heated surfaces of the #1 generator. Vessel is prohibited from operating the #2 generator for anything other than essential shipboard operations until seals are repaired, generator is cleaned and inspected and surrounding machinery is wiped down.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Electrical › Electric Generation Source (service) › Generator
Issued 7 June 2006
Resolved
The #3 generator could not operate because the turbocharger was being replaced. The vessel is prohibited from operating the #2 generator for anything other than essential shipboard operations until the classification society attests to the integrity of the repairs and generator.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Lifesaving › Lifeboat › Propulsion Engine
Issued 7 June 2006
Resolved
Starboard side lifeboat's engine would not start because of a faulty high pressure fuel injection pump.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 17 June 2006
Resolution: Received class report from BV clearing deficiency.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 7 June 2006
Resolved
Main engine #6 cylinder is leaking cooling water.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 7 June 2006
Resolved
Inboard fuel oil circulating pump is leaking oil excessively.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 7 June 2006
Resolved
Excessive oil found on the main engine and around the #1 & #2 generators. Clean excess oil and make arrangements.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 17 June 2006
Resolution: Received class report from BV clearing deficiency.
Engineering › Lubricating Oil Storage/Transfer System › Filter/Strainer
Issued 7 June 2006
Resolved
On the bottom deck of the engine room the lube oil purifier is un-assembled and inoperable. Re-assemble and repair.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Personnel › Training › Familiarization Training
Issued 7 June 2006
Resolved
Based on previously listed items and the vessel's history of repeated main engine and generator failures within the Mississippi River, the PSCO believes that the master, chief engineer and crew are not familiar with the essential procedures for the safe operation of the vessel.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 17 June 2006
Resolution: Received class report from BV clearing deficiency.
Engineering › Lubricating Oil Service System › Piping
Issued 7 June 2006
Resolved
In the engine room located on the 3rd deck on the starboard side the steam outlet valve going to the purifying station is leaking steam and water.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 10 June 2006
Resolution: Received class report from BV satisfying requirement.
Engineering › Sea-water System (primary cooling) › Pump
Issued 7 June 2006
Resolved
On the bottom beck of the engine room the #2 saltwater ballast water pump is un-assembled and inoperable. Re-assemble and repair.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 17 June 2006
Resolution: Received class report from BV clearing deficiency.
Construction/Loadline › Markings › Load Line Mark
Issued 15 May 2003
Resolved
Vessel's port and starboard deck lines are not marked in accordance with ICLL regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Resolution: Port and starboard deck lines were painted in a color contrasting to the hull.
Personnel › Certificates/Documents/Licenses
Issued 15 May 2003
Resolved
Chief Engineer does not have a flag state endorsement or documentary proof of application. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 16 May 2003
Resolution: Rcvd flag state endorsement letter on 16 May 03.
Fire Fighting › Fire Pumps
Issued 3 June 2002
Resolved
Priming pump for emergency fire pump is seized and inoperable. LEGACY COMPONENT DESC: Bearings
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2002
Resolved 3 June 2002
Resolution: Repaired and tested in presence of Marine Inspector.
Operations/Management › Vessel Safety Management
Issued 29 May 2002
Resolved
Vessel's master was found intoxicated on two separate occasions and unable to perform his duties. This is in direct violation of the company's Drug and Alcohol Policy and his responsibilities as prescribed in the SMS Manual. Provide results of external audit of vessel's SMS prior to departure.
LEGACY COMPONENT DESC: Master''''''''s Responsiblity/Authority
Action required: 705 - Other - as specified
Due 29 May 2002
Resolved 3 June 2002
Resolution: Cleared by complete Annual Freight Examination by NEWMS. Received audit report and attended vessel.
Construction/Loadline › Markings
Issued 19 February 2002
Resolved
Correct class society is not permanently affixed to vessel by plimsoll mark. ICLL 66 Annex I Ch 1, Reg 8. Repair to satisfaction of class. LEGACY COMPONENT DESC: Load Line Mark
Action required: 15 - Rectify deficiencies by next port
Due 29 May 2002
Resolved 29 May 2002
Resolution: Proper markings onboard vessel.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 February 2002
Resolved
Vessel's secondary radar was inoperable and vessel was given a letter of deviation to enter port with the requirement that it would be operational prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2002
Resolution: Vsl''s equipment was repaired per GSI Marine report dtd 21 Feb 02.
Construction/Loadline
Issued 13 May 2001
Resolved
EXCESSIVE OIL AND WATER IN BILGES AND ON DECK IN VICINITY OF MAIN GENERATOR(SOLAS 74A/1-11).
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 13 May 2001
Resolved
RUBBER DRAIN LINES ON MAIN ENINE TO STUFFING BOX AND TO A METAL CAN (SOLAS 74A/1-11).
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 13 May 2001
Resolved
RUBBER DRAIN LINES ON #1 AND #2 FUEL OIL PURIFIER (SOLAS 74A/1-11).
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Electrical
Issued 13 May 2001
Resolved
RUBBER DRAIN LINES ON #1 HIGH PRESSURE BOOSTER PUMP. RUBBER DRAIN LINES ON #2 AND #3 MAIN GENERATORS (SOLAS 74A/1-11).
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 13 May 2001
Resolved
UNABLE TO PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR. CAN NOT USE IN U.S. WATERS UNTIL DEMONSTRATED PROPERLY. (MARPOL 73/78 ANNEX I, REG 16(4)(5)).
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Unknown
Issued 13 May 2001
Resolved
#1 AND #2 GENERAL SERVICE PUMPS LEAKING. PROVIDE CLASS REPORT ATTESTING TO PROPER REPAIR OF BOTH PUMPS PRIOR TO NEXT U.S. PORT. (SOLAS 74A I/11)
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Navigation
Issued 11 January 2000
Resolved
PRIOR TO DEPARTURE PROVIDE TECH REPORT ATTESTING TO THE SATISFACTORY OPERATION OF BOTH NEW RADARS.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Unknown
Issued 11 January 2000
Resolved
PRIOR TO DEPARTURE REMOVE EXCESS DRUMS FROM STEERING GEAR ROOM.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Construction/Loadline
Issued 11 January 2000
Resolved
PRIOR TO DEPARTURE REPAIR HOLE IN BALLAST PIPING IN VICINITY OF GENERAL SERVICES PUMP TO SATISFACTION OF CLASS.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Fire Fighting
Issued 11 January 2000
Resolved
PRIOR TO DEPARTURE TEST THE FIREMAIN PIPING AND THE FIREPUMP. UNABLE TO TEST DUE TO SIGNIFICANT HOLE IN BALLAST PIPING.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Construction/Loadline
Issued 11 January 2000
Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT ATTESTING TO THE SATISFACTORY OPERATION OF BALLAST PUMP #2.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Engineering
Issued 23 June 1999
Resolved
BUNKER LINE PRESSURE TEST MISSING/ OUTDATED.
Condition: Unknown
Due 23 June 1999
Resolved 23 June 1999
Navigation
Issued 23 June 1999
Resolved
NEEDS BRITISH ADMIRALTY NOTICE TO MARINERS #16-23, AND MAKE CORRECTIONS.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Lifesaving
Issued 23 June 1999
Resolved
PORT SELF-IGNITING SMOKE SIGNAL EXPIRED.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Navigation
Issued 23 June 1999
Resolved
VESSEL'S ARPA RADAR WAS INOPERATIVE DURING INBOUND TRANSIT
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Navigation
Issued 23 June 1999
Resolved
MISSING SUPLEMENT #10 FOR BRITISH ADMIRALTY COAST PILOT.
Condition: Unknown
Due 28 June 1999
Resolved 28 June 1999
Fire Fighting
Issued 31 December 1998
Resolved
Perform satisfactory fire drill with the USCG in attendance prior to departure. SOLAS 74 amd III/18.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Documentation
Issued 16 October 1998
Resolved
Vessel sailed from SDCMS zone without a required deck rating. Vessel then entered the Port of Los Angeles without notifing the local COTP.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Engineering
Issued 8 October 1998
Resolved
Missing mechanical plugs for fuel vent containment.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Accommodation/Occupational Safety
Issued 8 October 1998
Resolved
Steam line in lower engineroom forward of main engine is leaking.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Fire Fighting
Issued 12 September 1996
Resolved
Make permanent repairs or provide condition of class for firemain piping main deck starboard side aft of #3 cargo hold. (cement patch)
Condition: Unknown
Due 22 January 1997
Resolved 22 January 1997
Navigation
Issued 24 October 1991
Resolved
DURING A ROUTINE ANNUAL EXAMINATION P. O. CORCORAN FOUND THAT THE VESSEL'S U. S. COAST PILOT WAS MISSING NOTICE TO MARINER'S CORRECTION'S FROM 25/88 THROUGH 34/90.
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993
Navigation
Issued 11 October 1990
Resolved
VESSELS N.O.S. CHARTS 18720,18740,18746, & 18751 WERE NOT CORRECTED TO DATEAS REQUIRED BY 33CFR164.33(a)(1)(ii).
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Navigation
Issued 11 October 1990
Resolved
VESSELS U.S. COAST PILOT AND U.S.C.G. LIGHT LIST WERE NOT CORRECTED TO DATEAS REQUIRED BY 33CFR164.33(a)(2)(i & ii).
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Fire Fighting
Issued 11 October 1990
Resolved
VESSELS FIRE NOZZLES WERE NOT OF THE DUEL PURPOSE REQUIRED BY SOLAS 74' PART A CH. II-2 REG 4.8.4.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995