MAURY USCG vessel records
← All vessels

A. J. WOOFTER

Built
1985
Last inspected
14 July 2014
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 14 July 2014
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 29 calendar years (1985–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

249142
Flag
UNITED STATES
Tonnage
41 - Simplified, Net Ton 41 - Simplified, Gross Ton
Maury page id
psix-249142
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

WILLIAM MARSHALL Towing Vessel · MISLE 80835 · 23 October 2008 · activity 3350281MARGARET Passenger Barge (Inspected) · MISLE 268624 · 23 October 2008 · activity 3350281WILLIAM MARSHALL Towing Vessel · MISLE 80835 · 2 August 2008 · activity 3290918MARGARET Passenger Barge (Inspected) · MISLE 268624 · 2 August 2008 · activity 3290918MARGARET Passenger Barge (Inspected) · MISLE 268624 · 19 August 2002 · activity 1663460

Inspection history · 48

14 July 2014 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4929506
15 April 2014 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4929500
1 May 2012 DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4299638
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4199525
22 June 2011 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4054411
24 March 2010 Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3711906
14 May 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3481139
23 October 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3350281
2 August 2008 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3290918
1 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3202656
9 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3081793
6 June 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2954164
29 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2764759
1 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2637617
14 April 2006 Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2624536
4 April 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2616380
28 April 2005 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2344649
20 April 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2339465
4 May 2004 Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2058680
3 June 2003 Examination of Repairs · Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1808876
19 August 2002 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1663460
15 August 2002 Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1668505
8 April 2002 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1618658
12 April 2001 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1061617
10 May 2000 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1049887
17 April 2000 Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1048547
28 April 1999 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1126555
20 April 1999 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1125179
28 April 1998 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 789766
16 April 1998 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 788615
21 April 1997 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1091849
25 April 1996 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1086254
28 April 1995 Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1340940
13 April 1995 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1033127
15 April 1994 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1171040
10 May 1993 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1132373
14 May 1992 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1259878
25 July 1991 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 933781
19 April 1991 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 914642
5 March 1991 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 928692
23 August 1990 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1215856
3 April 1990 Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1229385
14 March 1990 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1244621
22 March 1989 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1346597
25 March 1988 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1032975
27 April 1987 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1014745
28 March 1986 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998340
23 April 1985 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1289769

Deficiency record · 25

Engineering › Bilge Water Management System › Pump
Issued 14 May 2009 Resolved
Prove proper operation of bilge system.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 18 May 2009
Resolution: Vessel boarded and bilge system found to be working properly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 6 June 2007 Resolved
Paint rusted bottom of aft, lower deck portable fire extinguisher.
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 13 June 2007
Personnel › Training › First Aid/CPR
Issued 6 June 2007 Resolved
Provide proof of first aid / CPR training for at least 50% of crew
Action required: 705 - Other - as specified
Due 6 July 2007
Resolved 9 October 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 June 2007 Resolved
Provide procedures for making passenger counts available ashore while vessel is underway.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 13 June 2007
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 1 May 2006 Resolved
FIRE AND BILGE PUMP WORKS BUT HAS A LEAK IN THE SEAL THAT NEEDS REPAIRED.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 6 June 2007
Documentation › Markings/Placards › Vessel Number (state)
Issued 1 May 2006 Resolved
PUT HOMEPORT ON STERN.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 29 August 2006
Resolution: Information properly stenciled on stern.
Stability › Watertight Integrity › General
Issued 1 May 2006 Resolved
PROVIDE MEANS TO MAKE BELOW DECK COMPARTMENT VENTS WATERTIGHT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 29 August 2006
Resolution: Requirement does not apply to vessel on protected route.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 April 2005 Resolved
RECOMMENDED EMERGENCY LIGHTING FOR EXIT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Documentation › Markings/Placards › Vessel Number (state)
Issued 28 April 2005 Resolved
MARK VESSEL WITH NAME OF VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 April 2005 Resolved
POST LIFE JACKET PLACARDS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2005 Resolved
REPLACE 3 CHILDS PFD'S THAT TORE DURING INSPECTION DUE TO MOISTURE AND UV RAYS ROTTING THE OUTER LINING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 April 2005 Resolved
PROVIDE CREW TO CONDUCT DRILLS FOR ANNUAL CG INSPECTION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Engineering › Bilge Water Management System › Pump
Issued 28 April 2005 Resolved
DEMONSTRATE BILGE PUMP OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 2 May 2005
Resolution: CORRECTED
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 April 2005 Resolved
REPLACE ALL BELOW DECK PLASTIC SEWAGE LINES THROUGH HULL PENETRATIONS WITH STEEL PIPE OR STEEL VALVES ON EITHER SIDE OF THE BULKHEADS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2005
Resolved 18 April 2006
Resolution: CLEARED.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 4 May 2004 Resolved
Install additional typr B-II fire extinguisher in main deck snack bar
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 May 2004
Resolved 2 September 2004
Resolution: corrected
Construction/Loadline › Hull
Issued 15 August 2002 Resolved
MAKE PERMANENT REPAIRS TO 3RD WINDOW PORT SIDE ALONG WITH INNER AND OUTER SIDESHELL PLATING (ABOVE MAIN DECK) WHICH WAS DAMAGED IN A COLLISION 14AUG02. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2002
Resolved 9 September 2002
Resolution: Inspected repairs satisfactorily.
Lifesaving
Issued 20 April 1999 Resolved
Provide 1 child, and 2 adult PFD's to replace failed ones. Vessel limited to no more than 147 total persons, including 14 children until new jackets are on board.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Fire Fighting
Issued 20 April 1999 Resolved
Provide a new 50' fire hose for lower fire station. Vessel not to carry passengers until new hose is on board.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Lifesaving
Issued 16 April 1998 Resolved
Provide life jacket donning placard for kaypok life jackets IAW _x001C_ 46 CFR 185.516(a).
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Fire Fighting
Issued 16 April 1998 Resolved
Prove proper operation of fire/bilge pump prior to carriage of passengers, but no later than 29APR98.
Condition: Unknown
Due 28 April 1998
Resolved 28 April 1998
Lifesaving
Issued 5 March 1991 Resolved
PRIOR TO CARRYING MORE THAN 117 PERSONNEL ON BOARD, REPLACE ADULT SIZE LIFEPRESERVERS WHICH WERE REJECTED AT TIME OF CERTIFICATION. TOTAL REQUIRED ADULT SIZE LIFE PRESERVERS IS 124._x001C_
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Documentation
Issued 5 March 1991 Resolved
PRIOR TO CARRYING PASSENGERS, PLACE ON BOARD VESSEL'S STABILITY LETTER ISSUED 23APR85.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Lifesaving
Issued 5 March 1991 Resolved
PRIOR TO CARRYING PASSENGERS, PLACE ON BOARD MISSING RING LIFE BOUY EQUIPPED WITH A WATER LIGHT.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Documentation
Issued 3 April 1990 Resolved
CONTACT U.S. COAST GUARD HEADQUARTERS (G-MVI-5) TO ARRANGE FOR RE-MEASUREMENT OF VESSEL TO REFLECT VESSEL'S CURRENT LENGTH OF 80.8 FEET. UPON COMPLETION SUBMIT MEASUREMENT CERTIFICATE TO COAST GUARD DOCUMENTATIONOFFICE (ST. LOUIS) FOR ISSUANCE OF NEW CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Unknown
Issued 28 March 1986 Resolved
ISSUED CG-835 TO PROVIDE OR REQUEST WAIVER FOR SECOND POWER BILGE PUMP, DUETO VESSEL BEING CLASSIFIED AN "L" VESSEL.
Condition: Unknown
Due 28 March 1986
Resolved 28 March 1986

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.