Records from 1985 to 2025. Most recent: inspection, 2 October 2025.
Inspection history · 72
2 October 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8225505
5 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7976679
25 June 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7909712
17 October 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7785622
13 April 2023
Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7742738
16 August 2022
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7523477
24 June 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7497893
12 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7332345
29 June 2020
Internal Structural Exam · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6987031
25 June 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6724159
21 June 2018
Drydock Exam · Deficiency Check · DAPI Audit · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6450662
29 March 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6383711
21 August 2017
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6243042
17 August 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6243096
15 June 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5907792
28 May 2014
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4874005
22 May 2014
Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4865867
21 May 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4864817
20 April 2009
Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3457039
23 July 2008
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3277942
12 March 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2886465
3 April 2006
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2615896
14 April 2005
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2333451
28 March 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2323372
21 June 2004
Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2106242
24 September 2003
Simplified Stability Test
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2100753
20 June 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1843593
16 April 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1775055
30 May 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1620592
14 May 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1063442
17 April 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1403360
12 March 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 177828
18 May 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1050510
18 May 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376227
3 April 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365684
2 November 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 73845
20 October 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 180640
14 June 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 810391
14 May 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369178
19 August 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796991
15 July 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372312
13 May 1998
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434733
1 August 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 53477
9 July 1997
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1115142
21 May 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1111208
3 April 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1465313
28 December 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 143440
17 May 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383258
1 May 1996
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357592
30 April 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357591
26 May 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405723
18 May 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1181514
21 April 1994
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353556
15 July 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1158453
10 January 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1137816
11 December 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1142007
11 June 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 955570
20 May 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1262020
1 August 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939008
6 May 1991
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921078
13 June 1990
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235735
15 September 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1044423
12 September 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1208793
23 June 1989
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201910
6 June 1989
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1200784
5 May 1988
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 891827
7 May 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022187
19 November 1986
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1017402
7 May 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988152
18 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288374
28 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1289608
15 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290448
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 October 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset engines. The override for the fire boy system is not operating. Repair the override to the satisfaction of the attending marine inspector.
46 CFR 181.420 (b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2025
Resolution: Vessel provided objective evidence of repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 October 2025
Resolved
Wire connectors must be of the captive type such as the ring or the flanged spade type. The battery conections are secured with wingnuts. Place appropriate connectors on batteries to the satisfaction of the attending marine inspector.
46 CFR 183.340 (K)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 2 October 2025
Resolution: Vessel provided objective evidence of repairs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 August 2022
Resolved
Equipment and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the OCMI as good marine practice. The vessel's masthead light is not energized on same circuit as other navigation running lights. Wire the navigation lights to be on same circuit.
46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 23 August 2022
Resolution: Masthead light wired into navigation light switch.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 August 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts of large enough scale to make safe navigation possible. Vessel requires up to date charts.
46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2022
Resolved 26 August 2022
Resolution: New charts provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is restricted to 14 persons total due to lack of properly outfitted lifejackets until SOLAS tape and whistles are restored.
46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2021
Resolution: Purchased new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy and grab line is worn. Replace life ring buoy.
46 CFR 176.808(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2021
Resolution: Purchased new life ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 12 October 2021
Resolved
Each hatch exposed to the weather must be watertight. Forward deck hatch is not watertight and lacks securing
devices. Make forward deck hatch watertight and install securing devices on hatch cover in accordance with 46CFR171.124
46CFR171.124(a) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 October 2021
Resolution: Installed gasket, securing devices, and attachment lanyard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 October 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as
meeting the requirements of UL 1113. Electric bilge
pumps onboard should be model 10-6UL or 14A-6UL if made
by Rule.
46 CFR 182.520(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 November 2021
Resolution: Attended vessel and verified installation of UL 1113 submersible bilge pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Cables were supported with plastic zip-ties. Remove zip-ties and install metal supports.
46 CFR 183.340 (b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 November 2021
Resolution: All electrical cable supports were changed to metal supports.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 October 2021
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Kaleo Fernandez must provide valid medical certificate or proof from Honolulu Regional Exam Center that medical status is acceptable prior to operating. Send proof to [email withheld]
46CFR10.301(a)
Action required: 705 - Other - as specified
Resolved 16 August 2022
Resolution: Provided evidence of medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 October 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Replace the anchor chain support fixture prior to receiving next credit drydock.
46 CFR 176.700(a)
Action required: 705 - Other - as specified
Resolved 24 June 2022
Resolution: Special note was updated anchor chain support was verified replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2021
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Monthly log for portable extinguisher was created while inspectors were onboard.
46CFR176.810(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 12 October 2021
Resolution: Log started.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two adult lifejackets were missing. Provide additional life jacket in serviceable condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 31 July 2020
Resolution: Two new adult lifejackets were purchased and placed on the vessel with the vessel's name and appropriate retroreflective material.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 June 2020
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Toggles for ventilation duct opening on port side of engine space were wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 16 July 2020
Resolution: All port engine ventilation toggles have been replaced in-kind.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 June 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 16 July 2020
Resolution: VHF radio properly displays MMSI and LAT/LONG for DSC operation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 June 2020
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light was inoperable. Provide navigation lights that are in compliance with the Navigation Rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 16 July 2020
Resolution: Port running light has been replaced in-kind and is operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Two holes between engine room and forward adjacent hold allow fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 16 July 2020
Resolution: Holes in the engine room bulkhead have been properly sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2020
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 16 July 2020
Resolution: Vessel has replaced alcohol test strips in-kind with non-expired equipment.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 June 2019
Resolved
A preengineered fixed gas fire extinguishing system must automatically shutdown all power ventilation systems and all engines that draw intake air from within the protected space. During Fireboy discharge simulation test, main engine did not shutdown when wires were disconnected. Prove proper operation of preengineered fixed gas fire extinguishing system.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2019
Resolved 26 June 2019
Resolution: Proper operation of preengineered fixed gas fire extinguishing system demonstrated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2019
Resolved
Provide FCC Marine Operator's Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 26 June 2019
Resolution: FCC Marine Operator's Permit provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2019
Resolved
Provide proof of preemployment drug and alcohol testing and enrollment in random drug testing program for crewmember Dave.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 15 July 2019
Resolution: Received proof of satisfactory pre-employment drug testing and enrollment into consortium random testing pool.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 June 2018
Resolved
Repair 05 identified child size PFDs. Retro reflective material is worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 10 July 2018
Resolution: Vessel purchased three (03) new PFDs and repaired two (02).
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 June 2018
Resolved
Provide PFD donning placard for all types of PFDs onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2018
Resolution: Vessel replaced PFDs and all PFDs are the same type.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 21 June 2018
Resolved
Install flame shield on fuel strainer.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 10 July 2018
Resolution: Installed flame shield on bowl of strainer.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 June 2018
Resolved
Provide log of monthly EPIRB test.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2018
Resolution: Added monthly tests to vessel's Drill Log.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 June 2018
Resolved
Provide first aid kit with all required contents.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 10 July 2018
Resolution: Vessel purchased new first aid kit with all required contents.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 June 2018
Resolved
Provide VHF-DSC with GPS input.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: Vessel connected GPS to VHF.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 June 2018
Resolved
Provide a copy of company's drug and alcohol policy/statement.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 11 July 2018
Resolution: Vessel provided a copy of company's drug and alcohol policy.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 June 2018
Resolved
Provide proof that drug awareness training has been conducted.
Action required: 705 - Other - as specified
Due 28 June 2018
Resolved 10 July 2018
Resolution: Owner provided doucmentation that training was conducted for all crew members.
Engineering › Bilge Water Management System › Pump
Issued 21 August 2017
Resolved
Prove proper operation of bilge pump located in steering gear space in accordance with 46 CFR 182.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 23 August 2017
Resolution: Proper operation of bilge pump proved.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 21 August 2017
Resolved
Provide means to secure watertight hatches to hatch frame in accordance with 46 CFR 179.360.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 23 August 2017
Resolution: Hatch cover secured to hatch frame with captive chain.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 21 August 2017
Resolved
Make emergency broadcast placard specific to vessel in accordance with 46 CFR 184.506.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 23 August 2017
Resolution: Vessel name and call sign added to emergency broadcast placard.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 17 August 2017
Resolved
Vessel may not operate with greater than six passengers until successful completion of annual inspection.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2017
Resolved 21 August 2017
Resolution: Vessel had successful completion of COI.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 May 2014
Resolved
You are prohibited from carrying more than 6 passengers until you complete a credit drydock and internal structural exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Resolution: Completed DDX.
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2009
Resolved
Provide current FCC Station Lisence.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Vessel has current FCC Station Lisence.
Lifesaving › Lifefloat › Paddle
Issued 24 April 2009
Resolved
Provide securing lines for paddles in life float.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Proper securing lines for paddles provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2009
Resolved
Provide float light for life ring and properly mount and attach.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Witnessed proper operation and mounting of float light.
Engineering › Fuel Oil Service System › Hose
Issued 24 April 2009
Resolved
Determine condition of fuel return line and replace if necessary.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Return and supply fuel lines replaced and relocated to a more suitable location.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 April 2009
Resolved
Prove proper operation of fixed fire extinguishing system (system just serviced but did not indicate if shutdown test conducted and unsure of how to conduct test).
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Proved proper operation of FF system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2009
Resolved
Provide conduit for trim tab wiring.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Conduit installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 April 2009
Resolved
Provide current light list.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Provided current light list.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 April 2009
Resolved
Provide current tide tables.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Provided current tide tables.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 24 April 2009
Resolved
Provide recent local notice to mariners.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Provided updated LNM.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 April 2009
Resolved
Provide and mount stern light.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Proved proper operation and acceptable mounting location of stern light.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 20 April 2009
Resolved
Provide a light for the bilge high water alarm.
Action required: 705 - Other - as specified
Due 24 May 2009
Resolved 26 May 2009
Resolution: Proved proper operation of bilge high water alarm.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 April 2006
Resolved
Submit MIS report.
Condition: Unknown
Due 9 April 2007
Resolved 3 April 2006
Electrical › Electric Supply System (service) › Cable
Issued 14 April 2005
Resolved
Ensure all electrical wiring have correct support in the engine room.
Due 28 April 2005
Resolved 27 April 2005
Construction/Loadline › Penetrations › Valve Flange
Issued 14 April 2005
Resolved
Remove cap on through-hull valve in engine room.
Condition: Improper Installation
Due 21 April 2005
Resolved 27 April 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 21 June 2004
Resolved
Provide closure device/method for vents on engine room hatch.
Due 22 July 2004
Resolved 13 July 2004
Stability › Watertight Integrity › General
Issued 21 June 2004
Resolved
Provide adequate closure device for engine room bilge discharge thru hull.
Due 22 July 2004
Resolved 13 July 2004
Resolution: Thru hull was sealed and moved well above the water line w/check valve.
Stability › Watertight Integrity › General
Issued 21 June 2004
Resolved
Provide retaining device for steering compartment deck hatch.
Due 22 July 2004
Resolved 13 July 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 20 June 2003
Resolved
Prove main propulsion, vessel was unble to start engines.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 21 June 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2003
Resolved
Prove bilge alarms. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 21 June 2004
Fire Fighting › Fire Bucket › Availability
Issued 20 June 2003
Resolved
Provide fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 21 June 2004
Operations/Management › Drills/Instruction › Fire
Issued 20 June 2003
Resolved
Complete underway drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2003
Resolved 21 June 2004
Lifesaving › Lifejacket/PFD (Type III)
Issued 30 May 2002
Resolved
Provide (1) additional adult lifejacket in accordance with 46 CFR 180.71. Passenger count reduce by (1) adult until corrected.
Due 7 June 2002
Resolved 20 June 2003
Lifesaving › Lifebuoys
Issued 30 May 2002
Resolved
Properly mark ring lifebuoy in accordance with 46 CFR 185.604(a). LEGACY COMPONENT DESC: Ring Lifebuoy
Due 7 June 2002
Resolved 20 June 2003
Documentation › Certificates/Documents
Issued 30 May 2002
Resolved
Provide a valid FCC Station License and Safety Certificate in accordance with 46 CFR 184.502. LEGACY COMPONENT DESC: FCC Station License
Due 29 June 2002
Resolved 20 June 2003
Navigation › Piloting/Steering
Issued 30 May 2002
Resolved
Properly repair magnetic compass mount. LEGACY COMPONENT DESC: Magnetic Compass
Due 29 June 2002
Resolved 20 June 2003
Lifesaving
Issued 17 April 2001
Resolved
Replace hydro-release (hammer device) on EPIRB IAW 46 CFR 180.64 prior to operating more than three miles from shore.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Construction/Loadline
Issued 17 April 2001
Resolved
Attach fore and aft hatch covers with captive devices IAW 46CFR179.350._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 17 April 2001
Resolved
Service all fire extinguishers IAW 46 CFR 176.810 prior to operating with passengers.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 17 April 2001
Resolved
Register EPIRB with NOAA prior to operating more than three miles from shore IAW 46 CFR 180.64.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 3 April 2000
Resolved
Install closure devices for engine compartment ventilation iaw 46CFR 182.465.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Navigation
Issued 3 April 2000
Resolved
Acquire current edition of Collision Regulations/NAVRULES for vessel iaw 46CFR 184.420.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Lifesaving
Issued 3 April 2000
Resolved
Post lifejacket donning procedures iaw 46CFR 185.516.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Lifesaving
Issued 14 May 1999
Resolved
Replace white ring life buoy with orange ring required for coastal route.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Navigation
Issued 14 May 1999
Resolved
Acquire Coast Pilot (excerpt), and Light List (excerpt) for operating area.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 15 July 1998
Resolved
Lanyard between ring buoy and light was less than 2 feet in length. Provide a 3-6 foot lanyard for the ring life buoy waterlight.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Fire Fighting
Issued 15 July 1998
Resolved
Four portable fire extinguishers were beyond their required inspection date. Conduct annual tests of all protable fire extinguishers in accordance with chapter 4 of NFPA 10, per 46CFR176.810.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Documentation
Issued 21 May 1997
Resolved
Include all required elements of company drug policy to include random, post accident, pre-employment, and reasonable cause as per hard copy guidance provided.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE PROOF OF EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE PROOF OF 60 MINUTE SUPERVISOR TRAINING.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE CURRENT AND VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE PROOF OF CHEMICAL TESTING FOR ENTIRE CREW OF FIVE. OPERATION OF VESSEL TO CARRY GREATER THAN 6 PASSENGERS IS RESTRICTED TO ONLY CREW THAT CURENTLY SHOWS PROOF OF SATISFACTORY CHEMICAL TESTING.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE COMPANY DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 3 April 1997
Resolved
PROVIDE EMPLOYEE SIGNATURE PAGES FOR ACKNOWLEDGEMENT OF COMPANY DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Unknown
Issued 1 May 1996
Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS AND UNDERWAY MACHINERY & STEERING TESTS IN THE PRESCENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Electrical
Issued 1 May 1996
Resolved
ELECTRICALLY BOND PORT FUEL FILL PIPE.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 30 April 1996
Resolved
INSTALL SECURING DEVICE ON FWD CHAIN LOCKER HATCH COVER.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Accommodation/Occupational Safety
Issued 30 April 1996
Resolved
REPLACE BROKEN CENTER CABIN WINDOW.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Documentation
Issued 30 April 1996
Resolved
PROVIDE EMPLOYEE ACKNOWLEDGEMENT SIGNATURE PAGES FOR COMPANY DRUG AND ALCOHOL POLICY.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Documentation
Issued 30 April 1996
Resolved
PROVIDE PROOF OF 60 MINUTE SUPERVISOR TRAINING.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 30 April 1996
Resolved
REINSTALL MISSING SCREWS OR REPAIR HINGE ON FWD CHAIN LOCKER HATCH COVER.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Accommodation/Occupational Safety
Issued 30 April 1996
Resolved
REPAIR ALL BROKEN WELDS ON PORT AND STBD RAILINGS, LOCATED AFT.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Documentation
Issued 30 April 1996
Resolved
PROVIDE PROOF OF SUBMISSION OF MIS FORM TO COAST GUARD HEADQUARTERS.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Construction/Loadline
Issued 11 December 1992
Resolved
RENEW THE GASKET ON THE AFTER DECK WATERTIGHT HATCH COVER.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Engineering
Issued 20 May 1992
Resolved
PROVIDE A MEANS TO OPERATE THE FUEL SHUTOFF VALVES FROM OUTSIDE THE FUEL TANK/MACHINERY COMPARTMENT.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
SHORTEN HANDLE ON EMERGENCY TILLER FOR PROPER OPERATION.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Engineering
Issued 6 May 1991
Resolved
INSTALL A FLAME SHIELD ON THE RACOR FUEL FILTER.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Documentation
Issued 6 May 1991
Resolved
POST ON BOARD THE VESSEL A CURRENT FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Construction/Loadline
Issued 6 May 1991
Resolved
CONDUCT A SIMPLIFIED STABILITY TEST IN ACCORDANCE WITH 46 CFR 171.030(d)._x001C_ FOR DRAINAGE AND STABILITY, THE VESSEL IS CONSIDERED A WELL DECK VESSEL.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Engineering
Issued 6 June 1989
Resolved
CONDUCT OPERATIONAL TESTS OF MAIN PROPULSION ENGINE IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Navigation
Issued 6 June 1989
Resolved
INSTALL AN ALTERNATE MEANS OF STEERING. (REF: 46 CFR 182.30-5)
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 15 May 1985
Resolved
THE ENGINE RAW WATER SUCTION THROUGH HULL CONNECTION SHALL BE MADE WATERTIGHT.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Accommodation/Occupational Safety
Issued 15 May 1985
Resolved
COMPLETE INSTALLATION OF TOILET FACILITY AND TYPE III MARINE SANITATION DEVICE.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Unknown
Issued 15 May 1985
Resolved
PROVIDE COPY OF LAMINATE TEST RESULTS FOR GLASS CONTENT, TENSILE, AND FLEXURAL STRENGTH
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985