Inspection record

Last inspected 12 August 2026
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE5881
317316
Flag
UNITED STATES
Maury page id
psix-317316

Documentation record

Registered dimensions (L × B × D)39.8 ft × 24.0 ft × 5.4 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVENTURA, CA, UNITED STATES · built 1987
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portHALEIWA, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

12 August 2026 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8461202
6 May 2026 Vessel Attendance · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8369457
8 September 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8229834
29 May 2025 COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8104259
28 August 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7991605
9 July 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7938038
8 May 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7821170
31 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7689041
14 September 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7554676
31 May 2022 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7464792
24 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7205945
17 July 2020 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7006713
26 May 2020 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6965782
17 June 2019 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6718324
20 May 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6688139
1 August 2018 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6486010
17 May 2018 Administrative Inspection · Internal Structural Exam · In-Service Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6417003
16 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6148817
25 May 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5887042

Deficiency record · 51

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel plans on installing a roller furler for their jib sail in the next three to four months. Once furler is installed, vessel can not use the jib with passengers on board, until the jib furler and associated rigging is inspected and operationally tested in the presence of the attending CG marine inspector. 46 CFR 176.700(a)
Action required: 705 - Other - as specified
Resolved 12 August 2026
Resolution: New furler installed and operationally tested to the satisfaction of attending MI
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2026 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel must undergo sea trials after the mast and rigging is installed, tuned, and a satisfactory letter of attestation is received from a certificated rigger, to the satisfaction of the attending CG marine inspector. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Vessel successfully completed sea trials with the USCG and submitted a satisfactory attestation letter from rigger [name withheld]. Letter has been uploaded under "documents".
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2026 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. The vessel owner is requesting to make a change to the vessel's forward cross beam. The modification includes changing the angle of the beam from aft-facing, to facing straight up, along with replacing the installed chain plates. Submit alteration proposal to the attending marine inspector and modify identified areas in accordance with approved verbal repair proposal. 46 CFR 176.20-1(a) Old T
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Forward cross beam successfully repaired. Photos have been uploaded under "documents" of this section.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 May 2026 No resolution recorded
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews. The vessel's forward bow from port to starboard does not have deck rails or approved equivalent protection. Submit a written policy addressing how the vessel will implement physical or operational measures to a level that is considered an equivalent protection to railings to be approved by the OCMI. 46 CFR 177.35-1(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2025 Resolved
Each lifeline on a ring life buoy must have a breaking strength of at least 1,124 pounds. The lifeline on the ring life buoy is deteriorating. Replaced with the approved lifeline to the satisfaction of the attending marine inspector. 46 CFR 180.70(c)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received pictures of approved lifeline for ring life buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. The waterlight lanyard is deteriorating. Replaced with the approved lanyard to the satisfaction of the attending marine inspector. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received pictures of approved attached line for ring life buoy light
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 May 2025 Resolved
The Emergency Position Indicating Radiobeacons (EPIRB) must installed to automatically float free and activate. The EPIRB is stored in a casing that is non-float-free. Reinstall the EPIRB to automatically float free to the satisfaction of the attending marine inspector. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received pictures of EPIRB casing that allows EPIRB to automatically float free and activate
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 29 May 2025 Resolved
An Employee Assistance Program (EAP) training program must be conducted for the employer's crewmembers and supervisory personnel. Documentation of EAP training is missing. Provide a written record of EAP training to the satisfaction of the attending marine inspector. 46 CFR 16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received record of EAP trainings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Three life jackets were in unserviceable condition. 46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 29 May 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 July 2024 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. In the starboard hull amidships, 1 side longitudinal has fractured off the hull, and 1 side longitudinal has delaminated plywood. Submit a repair proposal to the satisfaction of Marine Inspector. 46 CFR 177.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 24 July 2024
Resolution: Operator removed delaminated plywood, replaced with good wood. Laid 10oz 3" Fiberglass sheets over new stringer. Repairs found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 July 2024 Resolved
Fuel tanks shall be adequately supported and braced to prevent movement. The supports and braces shall be insulated from contact with the tank surfaces with a non-abrasive and non-absorbent material. Gasoline fuel tanks on deck are missing straps to secure to deck. 46 CFR 182.15-25 OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2024
Resolved 24 July 2024
Resolution: Installed new straps for gasoline fuel tanks.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 July 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Stbd bilge high water level alarm light is not operational. One additional crew member required to act as roving watch. Consequently, total passenger count is reduced by one to account for additional crew, until deficiency is rectified to the satisfaction of the attending marine inspector. 46 CFR 182.530
Action required: 705 - Other - as specified
Resolved 12 July 2024
Resolution: Bilge high level alarm repaired and determined to be operational by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 May 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Repair the fractured weld where the stanchion is welded to the mounting pad that fasten the deck rail to the vessels structure on the stbd second handrail stanchion from the bow within seven days (7) to the satisfaction of the attending MI. 46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 7 June 2023
Resolved 28 June 2023
Resolution: Received email from vessel owner with photographs of the stbd handrail repaired to the satisfaction of the MI.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 31 May 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 28 June 2023
Resolution: Received email from vessel rep with a photograph of a crew member using the radio remote microphone and the emergency broadcast placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 May 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide an approved First aid kit to the satisfaction of the attending MI. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 14 July 2023
Resolution: Received email from vessel rep with photographs of the iodine swabs and Ammonia inhalants for the first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 May 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. Missing Coast Guard Light List. Provide Coast Guard Light List to the satisfaction of the attending MI. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 7 August 2023
Resolution: Received email with photograph of the 2023 Coast Guard Light List.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Missing the above requirement. In lieu of the valve direction, substitute the following: "TO STOP FUEL SUPPLY DISCONNECT FUEL HOSE FROM TANK." 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 18 July 2023
Resolution: Received photograph of fuel shutoff stations' labeling.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023 Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has three types of life jackets, but only one placard type. Post additional placard for the other two types of life jackets. 46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 28 June 2023
Resolution: Received email from vessel rep with a photograph of the lifejacket placard posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
Where flexibility is necessary or desired, a reasonable length of flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils and vibration. The port portable fuel tank hose is not labeled to determine if it meets the regulation. Replace with approved gasoline fuel hose that meets the J1527 standard. 46 CFR 182.15-40(a)(2) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 18 July 2023
Resolution: Received photograph of the new port fuel portable fuel tank fuel line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel PMP inventory of rigging components replacement intervals was not updated when rigging was renewed at the June 2020 dry dock. Provide third party rigging report from the June 2020, dry dock and an updated inventory of rigging components. 46 CFR 176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 28 June 2023
Resolution: Recieved report of work and rig index report from the vessel's June 2020 drydock; all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 31 May 2023 Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Crew members and supervisory personnel did not receive the above required training. Provide a training roster of attendance signed by crew members and DER to attest the training was provided to the satisfaction of the attending MI. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 8 August 2023
Resolution: Received email from vessel rep with photographs documenting supervisor and crew attending the required training.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 May 2023 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weather tight: (1) A hatch on a water tight trunk that extends at least 305 millimeters (12 inches) above the weather deck; (2) A hatch in a cabin top; and (3) A hatch on a vessel that operates only on protected waters. Vessel's operates on exposed waters and the two forward hull hatches are not watertight. Make watertight and prove they are watertight in the presence of the attending MI. 46 CFR 171.124(a) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 18 July 2023
Resolution: Received .mov of the hatches being sprayed and then opened, validating no water ingress.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 September 2022 Resolved
Non-subdivided vessels operating on a limited coastwise route, in warm water, less than 3 NM from shore must be equipped with life floats with total capacity of 50 percent of the total persons the vessel is certificated to carry or a float free, Cat 1 406 MHz EPIRB. The vessel is not outfitted with life floats and the provided EPIRB battery is expired. Until life floats or EPIRB is provided, the vessel is restricted to operate in warm waters within 1 miles from shore on a Lakes, Bays and Sounds Route. 46 CFR 180.205(e)
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Vessel provided a new EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 September 2022 Resolved
Vessels operating on a limited coastwise route must carry a minimum of 12 distress signals, 6 of which must be hand red flare approved with 160.021. The vessel was only equipped with 4 hand red flares. Vessel is restricted to a lakes, bays, and sounds route until 2 additional hand red flares are provided. 46 CFR 180.68(a)
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Two additional hand red flares were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2022 Resolved
One type 1 adult life jacket must be provided for each person carried on board a vessel. The vessel is certificated to carry 22 persons, 19 of which may be passengers. Only 20 life jackets were provided. Vessel is limited to 17 passengers until two additional life jackets are provided. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 14 September 2022
Resolution: Two additional life jackets were provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 31 May 2022 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has area of delaminated fiberglass on the stbd hull. Grind and scarf 12:1 and re-laminate in accordance with NVIC 8-87. 46 CFR 177.300 (c)
Action required: 705 - Other - as specified
Resolved 8 June 2022
Resolution: Repair inspected and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 May 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Vessel railings were removed. Reinstall for attending marine inspector. 46 CFR 177.900 (b)
Action required: 705 - Other - as specified
Resolved 17 June 2022
Resolution: Rails were installed and tested to the satisfaction of the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022 Resolved
Sail rigging and components are to be maintained in accordance with good marine practice. Observed boom held in place by bolt that is larger than the width of the connection points and reef horns were bent. Replace hardware to the satisfaction of attending marine inspector. 46 CFR 176.800
Action required: 705 - Other - as specified
Resolved 17 June 2022
Resolution: Hardware replaced to the satisfaction of the marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022 Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway. Conduct sea trial prior to credit drydock. 46 CFR 176.802 (c)
Action required: 705 - Other - as specified
Resolved 17 June 2022
Resolution: A post dry dock sea trial was conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021 Resolved
In the application of inspection standards due consideration must be given to the hazards involved in the operation permitted by a vessel's Certificate of Inspection. Nylon rope holding trampoline net is severely frayed in several sections. Replace rope prior to carry passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
Resolution: Trampoline line replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy grab line deteriorated and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 2 June 2021
Resolution: New ring life bouy installed.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 24 May 2021 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation. 47 CFR 80.905
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 2 June 2021
Resolution: GPS position synced into VHF.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 May 2021 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot [name withheld] List, tide tables, and current tables. Latest versions of coast pilot and light list not onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 2 June 2021
Resolution: New pubs placed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 July 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] underwent bow beam repair in 2018, and as part of the repair proposal the bow beam was to be replaced in 2020 drydock cycle. Due to supply chain delays, bow beam installation delayed 1 month and vessel may continue to operate on existing bow beam. 46 CFR 176.700 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 11 August 2020
Resolution: Vessel installed new bow beam. 3rd party rigging survey attached in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] rudder post bent 3/16" and damaged fiberglass hull. Renew in kind. 46 CFR 176.700 (a)
Action required: 705 - Other - as specified
Resolved 29 June 2020
Resolution: Vessel renewed stbd rudder
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 May 2019 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color; Distress flares and smoke signals we in a clear watertight container. Provide a watertight container of a bright color.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Received email showing a watertight container of a bright container on board vessel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 May 2019 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers; Stbd high level audible alarm at operating station is in operable. Repair audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2019
Resolution: Received video of operable high water alarms
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction; entire weld for the base of the fwd port stanchion was found crack; repair weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Received photo of repaired weld
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction; Cracking was found above the base of the fwd stbd stanchion, repair crack on stanchion.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2019 Resolved
The constriction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in closed spaces, and necessary facilities for passengers and crew; Laminate frames in fwd port side hatch was for cracked. repair frames
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Received email provinding proof of frames in fwd port side hatch repaired
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 1 August 2018 Resolved
Each certificated small passenger vessels that operates in Sector Honolulu's inspection zone, that has a reduced manning endorsement connected to in-water activities, shall prove to the satisfaction of an attending Marine Inspector, that it meets or exceeds the provisions outlined in Sector Honolulu's Work Instruction 31. Provide required documentation and equipment listed in Work Instruction 31. Vessel must maintain the required manning levels specified on COI of one (1) master and one (1) deckhand, on board the vessel at all times when passengers have access to the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2018
Resolved 15 August 2018
Resolution: Vessel provided suitable policy that satisfies requirements based on vessel's operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2018 Resolved
Deck rails on a vessel engaged in excursion trips,including but not limited to sightseeing trips, dinner and party cruises, must have the following installed between the top rail and deck: chain link fence or wire mesh that has openings not more the four inches in diameter, or bars, slats, rail courses or equivalent spaced at intervals not more than four inches. Vessel has rail courses spaced at 12 inches. Install chain link fence, mesh or courses to the satisfaction of the attending Marine Inspector. Submit plans to OCMI for approval prior to modifying vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 29 June 2020
Resolution: Vessel installed new handrails.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 August 2018 Resolved
A vessel must comply with applicable requirements for any radio installations as set forth in 47CFR80. VHF-DSC shall be programmed with MMSI and integrated with GPS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 30 August 2018
Resolution: Vessel installed a GPS and connected to VHF-DSC radio. Radio shows that it is receiving a GPS input.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 May 2018 Resolved
Code 01305: The operator could only provide one month, September 2017, as evidence of conducting a rigging inspection aloft to the marine inspector. PMP records presented to inspector indicate the operator is visually inspecting the standing and running rigging at deck level monthly. Inspector found sheered fasteners on the starboard cap shroud chain plate, elongated linkage at the longeron to bow beam connection, damaged retaining pins at the longeron to bow beam connection, fractured reefing hook at the gooseneck, and elongated linkage at the port and starboard bow beam connection to hull. Operator shall provide 3rd party rigging surveyor report, to include rigging inspection aloft, prior to carrying passengers. Operator shall follow a preventative maintenance plan to adequately assess the safe condition of the sail rigging system. Provide evidence of a preventative maintenance plan regime to USCG OCMI in 30 days. 46 CFR 176.800(a) and 46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2018
Resolved 15 June 2018
Resolution: Operator hired a third party surveyor to conduct a rigging inspection and establish a PMP baseline. Operator conducted a PMP daily, weekly, and monthly inspection per third party rigger survey report and recommendations.
Sail Rigging › Chainplates › Fasteners
Issued 17 May 2018 Resolved
Code 02199: Starboard capshroud chain plate fasteners found corroded and sheered off at the fastener bolt head when operator attempted to remove fastener. PMP states fasteners should be checked for "creep" corrosion. Licensed master provided one years worth of PMP stating that fasteners were visually inspected for corrosion with no notation of the corrosion visually observed. Remove all fasteners on the starboard chain plate for inspection. Remove A-frame fasteners at the bow beam for inspection. 46 CFR 176.802(a)(3)
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 15 June 2018
Resolution: Chain plates and fasteners replaced in kind on cap shrouds, port/stbd, and bow beam, port/stbd.
Sail Rigging › Catamaran › Crossbeam
Issued 17 May 2018 Resolved
Code 02199: Bow beam found fractured at weld joint for head stay linkage. Licensed master visually inspected fracture along with the vessel owner and did not indicate issues on the PMP or to Coast Guard inspector. Fractured bow beam and loss of head stay will lead to dismasting. Submit repair proposal to OCMI for approval prior to conducting repairs. 46 CFR 176.802(a)(3) and 46 CFR 176.700
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 15 June 2018
Resolution: Bow beam repair plan submitted and accepted. Bow beam repaired in accordance with repair plan. See documents. Sea trial and auxiliary sail trial conducted; all sat.
Sail Rigging › Sails › Reefing Points
Issued 17 May 2018 Resolved
Code 99101: Reefing hook found fractured in two areas. Vessel is restricted from operating on routes with strong winds in which the master deems a reef in the sail is needed or from reducing sail area by adding a reef in the sail. 46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2018
Resolved 15 June 2018
Resolution: Reefing hook replaced in kind and auxiliary sail sea trial completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 May 2017 Resolved
Port and Starboard side railings are loose. Submit repair proposal for cracked base of railing stanchions. 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 14 June 2017
Resolution: Cracked base was ground down and re-welded. The port and starboard railings have had a larger backing plate placed on the inside of the hull for support until new railings are installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 May 2017 Resolved
Port hold stringers on longitudinal bulkhead broken/missing/loose. Submit repair proposal for permanent fix. 46CFR176.802
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 25 June 2017
Resolution: Received drawing for stiffener proposal on 25JUN after stiffeners were attached on 13JUN.
Documentation › Certificates/Documents › FCC SSL
Issued 16 May 2017 Resolved
Provide proof of marine radio opertor permit. 47CFR80
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 5 June 2017
Resolution: Picture received of permit
Sail Rigging › Stays/Shrouds › Wires
Issued 25 May 2016 Resolved
Owner needs to submit a 3rd party rigging report to satisfy the inspection requirements.
Due 25 June 2016
Resolved 22 June 2016
Resolution: 3rd party riggng inspection was submitted.

Ownership record