MAURY USCG vessel records Sign in
← All vessels

SOUTHERN BELLE

SOUTHERN BELLE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1985, most recently in February 2026, along with 72 deficiencies and 1 casualty investigation in 2016.

Records from 1985 to 2026. Most recent: inspection, 25 February 2026.

Built
1985
Last inspected
25 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBR3430
249890
Flag
UNITED STATES
368076580
Maury page id
psix-249890

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1985–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)96.2 ft × 34.0 ft × 5.0 ft
Registered tonnagegross 98 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO INC · GUILD, TN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHATTANOOGA, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK6642MMSI 368076580 · active · compulsorily equipped · granted 14 February 2019, expires 14 February 2029 · licensed under a name not among this hull’s recorded names (not shown)
WBR3430MMSI 367326770 · expired · compulsorily equipped · granted 13 December 2007, cancelled 12 May 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAROLE K Towing Vessel · MISLE 966275 · 12 November 2016 · activity 6050747R. H. BAKER Towing Vessel · MISLE 64698 · 15 August 2002 · activity 1668775

Inspection history · 65

25 February 2026 Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8316399
21 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8082390
4 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8073931
29 February 2024 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7872413
8 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7685933
30 November 2022 COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7584183
28 February 2022 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7403277
8 March 2021 Administrative Inspection · MTSA Verification · Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7154331
4 March 2020 Administrative Inspection · Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6924441
5 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6906291
4 March 2019 DAPI Audit · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6636371
5 December 2017 MTSA Verification · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6316310
6 March 2017 MTSA Verification · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6101641
14 November 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6040879
12 November 2016 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6050747
12 January 2016 Administrative Inspection · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5802898
8 October 2014 Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5056435
19 July 2012 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4385043
4 June 2012 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4512668
1 December 2011 Administrative Inspection · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4199210
7 December 2010 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3922160
13 January 2010 Administrative Inspection · DAPI Audit · MTSA Verification · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3655966
14 January 2009 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3393257
26 January 2008 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3136957
11 December 2007 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3113466
6 March 2007 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2884946
9 February 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2583105
21 March 2005 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2321060
6 January 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2272540
14 January 2004 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2013047
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968302
3 January 2003 COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1725063
16 August 2002 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1665289
15 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1668775
21 February 2002 Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1488393
23 January 2002 Re-Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1482326
13 February 2001 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 212924
13 February 2001 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1450569
2 March 2000 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1046869
18 January 2000 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1361312
6 January 2000 Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1467179
17 March 1999 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 809339
20 January 1999 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1472813
28 January 1998 Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1406255
7 January 1997 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1424317
4 January 1996 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1424179
19 April 1995 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 854659
19 January 1995 COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1454161
3 May 1994 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1168950
7 April 1994 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1168060
11 February 1994 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1162722
28 April 1993 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1376980
24 March 1993 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1423765
17 February 1993 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1144419
6 May 1992 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 946417
10 March 1992 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 944612
4 April 1991 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1228944
13 March 1991 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1238362
3 April 1990 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1221001
30 January 1990 Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 912763
6 April 1989 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1206842
7 June 1988 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 889067
11 June 1987 COI Inspection
Physical examination · MSO NASHVILLE · Activity 1030205
11 June 1986 COI Inspection
Physical examination · MSO NASHVILLE · Activity 997950
11 June 1985 Type not recorded
No type recorded · MSO NASHVILLE · Activity 1289777

Deficiency record · 72

Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 December 2017 Resolved
Instructed vessel representative to have members recovering MOB tethered to the vessel when operating on the fwd gangway.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Vessel representative placed the requirement into effect for all crew.
Fire Fighting › Means of Escape › Blocked
Issued 5 December 2017 Resolved
Emergency egress from workspace fwd of the engine room was blocked by chairs on the deck above.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Vessel representative moved all obstacles from the hatch and crew was given training on safety egress.
Engineering › Steering Gear System › Cable
Issued 14 November 2016 Resolved
Cable parted
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 15 November 2016
Resolution: Replaced Cable.
Fire Fighting › Fire Hoses › Condition
Issued 1 December 2011 Resolved
One lenght of fire hose has the outer cover chaffed in several places casued by the movement of the vessel when the hose is in the stored position. Must replace that length of hose and install chaffing gear to protect cover.
Action required: 705 - Other - as specified
Due 25 February 2012
Resolved 26 January 2012
Resolution: Purchased and installed new fire hose. Bends are protected by chaffing gear.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 December 2011 Resolved
Protective covering on main switchboard not installed. Design and install protective covering to prevent accidental shock of personnel.
Action required: 705 - Other - as specified
Due 25 February 2012
Resolved 1 February 2012
Resolution: fabricated cover, inspected by marine inspector. All Sat.
Documentation › Markings/Placards › Capacity Marking
Issued 25 January 2011 Resolved
Maximum number of passengers permitted above main deck is not labeled at the stairwells to the second deck. Label each stairwell to indicate the maximum number of passengers permitted above the main deck IAW stability letter. Label must be durable markings of at least 1 inch to read the "Max # of passengers above this deck: 450"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2011
Resolution: New signs have been posted at all three stairwells from main deck to second deck with correct information listed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 January 2011 Resolved
Lifejacket stowage area located on the outside of the #2 deck is not labeled with the number of available lifejackets on the port or starboard side. Label both accordingly to reflect the number of lifejackets available.
Action required: 705 - Other - as specified
Due 8 February 2011
Resolved 9 February 2011
Resolution: Lifejacket stowage areas on the port and starboard exterior of the 2nd deck are labeled with the number of lifejackets availlable respectively.
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 January 2011 Resolved
Lifejacket stowage areas located outside on the 2nd and 3rd deck do not have lifejacket donning instruction placards posted. Post lifejacket donning placards in all locations lifejackets are stowed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2011
Resolution: Lifejacket donning instruction placards are posted near the outside stowage locations on the 2nd and 3rd decks.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 25 January 2011 Resolved
COI indicates 535 Adult lifejackets are requried. Vessel currently has 503 Adult lifejackets on board. Provide 32 additional life jackets for adults and ensure stowage labels reflect correct amounts. Must be done prior to carrying over 503 adult passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2011
Resolved 25 January 2011
Resolution: Thirty-Two (32) adult lifejackets were located and brought on board prior to marine inspectors departing.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 25 January 2011 Resolved
Starboard engine has a fuel leak at governor. Repair fuel leak on starboard engine.
Action required: 705 - Other - as specified
Due 1 February 2011
Resolved 26 January 2011
Resolution: Fuel leak has been repaired on starboard engine.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 13 January 2010 Resolved
Vessel's 2 air receivers were due for internal inspection. External inspection of receivers and relief valves were satisfactory, internal inspection to be conducted during next annual inspection.
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 20 January 2011
Resolution: Satisfactory internal inspection conducted on air receivers this date.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 January 2009 Resolved
The 2008 MIS report had not been filed. it is due by 15 Mar 09. Provide copy of MIS report for 2008.
Action required: 705 - Other - as specified
Due 15 March 2009
Resolved 3 March 2010
Resolution: When conducting 2010 Annual inspection, reviewed 2008 MIS report.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 December 2007 Resolved
Provide guards for all lighting fixtures on third passenger deck.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 10 January 2008
Resolution: Guards all placed on all third deck lights.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2007 Resolved
Re-wire bilge float in A/C intake space.
Action required: 705 - Other - as specified
Due 12 January 2008
Resolved 12 December 2007
Resolution: Bilge float rewired to keep wiring out of bilge.
Engineering › Steering Gear System › Pin
Issued 12 December 2007 Resolved
Prior to geting underway w/ passengers replace make shift pin in steering hydraulic ram with cotter pin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2007
Resolution: Replaced with cotter pin.
Fire Fighting › Fire Hoses › Condition
Issued 9 February 2006 Resolved
Vessel name not stenciled on hoses. Item corrected prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Fire Fighting › Fire Hydrants › Location/Position
Issued 9 February 2006 Resolved
Control valves at each fire hydrant on board was pointing in the 12:00 position. Required vessel O/O to reposition valves to be horizontal to 6:00 position. Valves moved and item corrected prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 February 2006 Resolved
Upper hinge on starboard fire door exiting main deck salon was found corroded and preventing fire door from closing by causing door to hit door jam. Vessel O/O was already addressing situation and had new door that had just been painted and was being readied to be installed to replace the deficient door. Cleared rqmt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2006
Resolved 9 February 2006
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 9 February 2006 Resolved
Found door retention hooks installed for fire doors at top of stairways leading from the main deck salon to the 2nd deck. Required vsl O/O to remove hooks which was done prior to the completion of the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2006
Resolved 9 February 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 February 2006 Resolved
Vessel O/O had purchased several new PFD's to replace deficient PFD's prior to CG inspection but neglected to stencil vessels name on jackets. Name placed on new PFD's prior to the completion of the inspection.
Action required: 705 - Other - as specified
Due 9 February 2006
Resolved 9 February 2006
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 14 January 2004 Resolved
3rd deck - Lifejacket locker/seat, recently painted. No stencil/placard exists, labeling contents of the locker. Label IAW 46CFR180.78 prior to carriage of passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2004
Resolution: Placarding installed.
Electrical › Electric Generation Source (service) › Generator
Issued 23 August 2002 Resolved
#1 SSDG Damaged, Due to Engine Room Fire 15AUG02. Repairs incomplete, Due to fuel Line availability. Vessel will be restricted to #2 SSDG and battery Back-Up, until complete repair and testing of #1SSDG is made to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Due 7 September 2002
Resolved 5 September 2002
Resolution: Repairs made, generator tested satisfactorily under load w/attending Marine Inspector aboard.
Electrical › Electric Generation Source (service) › Conductor
Issued 23 August 2002 Resolved
Remove abandon wiring, some of old gauge panel wiring that has been renewed is still in the gauge panels.
Condition: Damaged By Earlier Event
Due 7 September 2002
Resolved 5 September 2002
Resolution: Abandon wiring removed.
Electrical › Electrical Distribution System (service)
Issued 16 August 2002 Resolved
Make repairs to Engine Room, Due to Fire/Smoke Damage sustained 15AUG02. All such repairs must be IAW 46 CFR 115.700 (a). All repairs not made "In Kind" shall be made IAW 46 CFR 115.700 (b),(c),(d). LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2002
Resolution: Distribution wiring, meters, stuffing tubes and associated components surveyed by marine electrician and/or renewed "In Kind", all sytems tested satisfactory, w/Marine Inspector present.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 August 2002 Resolved
BMDE; gauge panels/wiring, intake air systems damaged, due to fire 15AUG02. Make repairs IAW 46 CFR 115.700 (a). Any repair not made "In Kind" shall be made IAW 46 CFR 115.700 (b), (c), and (d).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2002
Resolution: All repairs made by Engine Manufacturer, "In Kind". The propulsion systems/steering systems was operationally tested in the presents of the attending Marine Inspector.
Fire Fighting › Fire Hoses
Issued 16 August 2002 Resolved
Fire Hose destroyed by Eng Room Fire, must be renewed. Fire Pump located in Engine Room must be Cleaned Surveyed for damage, demonstrate proper operation to attending Marine Inspector. LEGACY COMPONENT DESC: Material
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2002
Resolution: Hose renewed "In Kind", Fire Main Tested Satisfactory w/attending Marine Inspector aboard vessel.
Deck/Cargo › Mooring/Anchoring
Issued 16 August 2002 Resolved
Debarkation ramp, damaged upon loss of power/landing, due to engine room fire 15AUG02. Repair/Weld crack.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2002
Resolution: Welding repairs made.
Electrical › Electric Generation Source (service)
Issued 29 January 2002 Resolved
Vessel's starboard generator is undergoing overhaul, requirment is to return to vessel and perform full load test when maintenance is complete. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Due 15 February 2002
Resolved 21 February 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 January 2002 Resolved
Prove proper operation of forward mast headlight before vessel operates under any circumstance.
Condition: Unknown
Due 29 January 2002
Resolved 29 January 2002
Resolution: Replaced forward headlight bulb.
Electrical › Lighting (service)
Issued 29 January 2002 Resolved
Remove various holiday lighting decorations from vessel's exterior. LEGACY COMPONENT DESC: Lighting Fixture
Due 15 February 2002
Resolved 21 February 2002
Navigation
Issued 13 February 2001 Resolved
Replace existing running light bulbs with "perko" style running lamps IAW the navigation rules.
Condition: Unknown
Due 13 February 2001
Resolved 20 February 2001
Electrical
Issued 13 February 2001 Resolved
Place starting batteries in protective boxes with covers.
Condition: Unknown
Due 13 February 2001
Resolved 20 February 2001
Construction/Loadline
Issued 13 February 2001 Resolved
Repair leaking drain line in #2 void.
Condition: Unknown
Due 13 February 2001
Resolved 20 February 2001
Lifesaving
Issued 13 February 2001 Resolved
Replaced 35 adult PFD's and reduce total adult capacity to 500 until these PFD's are replaced.
Condition: Unknown
Due 13 February 2001
Resolved 20 February 2001
Lifesaving
Issued 18 January 2000 Resolved
Replace vessel life buoys on starboard bridge wing and forward passenger_x001C_ area of third deck.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Navigation
Issued 18 January 2000 Resolved
Repair stern running light.
Condition: Unknown
Due 18 January 2000
Resolved 20 January 2000
Engineering
Issued 18 January 2000 Resolved
Repair engineroom exhaust ventilation system motor.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 18 January 2000 Resolved
Place "Emergency Broadcast Placard" in the area of VHF radios on bridge.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Documentation
Issued 20 January 1999 Resolved
Post Stability Letter on bridge as per 46 CFR 115.306.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Construction/Loadline
Issued 20 January 1999 Resolved
Install Bilge High Level Alarms as per 46 CFR 119.530 by 11MAR99.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Documentation
Issued 20 January 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Lifesaving
Issued 20 January 1999 Resolved
Paint and label container for distress signals as per 46 CFR 117.68 and 122.614.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Lifesaving
Issued 20 January 1999 Resolved
Install reflective tape on all lifebouys as per 46 CFR 117.70.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Lifesaving
Issued 20 January 1999 Resolved
Post Lifejacket Placards on passenger decks as per 46 CFR 122.516.
Condition: Unknown
Due 20 January 1999
Resolved 20 January 1999
Electrical
Issued 19 January 1995 Resolved
PROPERLY INSTALL PROTECTIVE COVERS ON MAIN DECK SALON INCANDESCENT FIXTURES. NOTE: THIS ITEM WAS RESCINDED BY OMCI PADUCAH LETTER 16710 DATED 08MAR95. COPIES OF RELATED CORRESPONDENCE HAVE BEEN PLACED IN THE VESSEL FILE.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 19 January 1995 Resolved
PROVIDE EVIDENCE OF AN EMPLOYEE ASSISTANCE PROGRAM AS DESCRIBED IN 46 CFR 16.401.
Condition: Unknown
Due 19 January 1995
Resolved 19 January 1995
Lifesaving
Issued 11 February 1994 Resolved
CONDUCT CREW DRILLS; FIRE, ABANDON SHIP,MAN OVERBOARD, AND FLOODING.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Lifesaving
Issued 11 February 1994 Resolved
THE NUMBER OF ADULT PASSENGERS ALLOWED ON BOARD IS LIMITED TO 494 UNTIL 13 ADDITIONAL ADULT SIZE PFD ARE INSPECTED, STAMPED BY A COAST GUARD INSPECTOR, AND PLACED ON BOARD.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Construction/Loadline
Issued 11 February 1994 Resolved
REPLACE PIPE PLUGS, INBOARD OF CHECK VALVES, FOR THE UNUSED PORT AND STBD SHAFT PACKING DRIP PAN OVERBOARD DISCHARGES.
Condition: Unknown
Due 30 March 1994
Resolved 17 February 1994
Electrical
Issued 11 February 1994 Resolved
REPAIR OR REPLACE ELECTRICAL OUTLET SPLASH GUARD IN MAINDECK PANTRY.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Accommodation/Occupational Safety
Issued 11 February 1994 Resolved
REPLACE VENT FAN IN 2ND DECK WOMEN RESTROOM.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Electrical
Issued 11 February 1994 Resolved
REMOVE WIRING FOR UNUSED AUTOMATIC PUMPS FOR PORT AND STBD SHAFT PACKING DRIP PANS.
Condition: Unknown
Due 30 March 1994
Resolved 17 February 1994
Electrical
Issued 11 February 1994 Resolved
REPAIR STBD EMERGENCY LIGHT, 2ND DECK FORWARD.
Condition: Unknown
Due 30 March 1994
Resolved 17 February 1994
Accommodation/Occupational Safety
Issued 11 February 1994 Resolved
REPAIR WALL IN THE 2ND DECK WOMEN RESTROOM.
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Engineering
Issued 17 February 1993 Resolved
INSTALL PLUG OR CAP AFTER VALVE ON LUBE OIL TANK IN ENGINE ROOM.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Documentation
Issued 17 February 1993 Resolved
PROVIDE VALID FCC STATION LICENSE ON BOARD.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Lifesaving
Issued 17 February 1993 Resolved
PROVIDE 14 ADDITIONAL ADULT PFD ON BOARD, MAXIMUM ADULT PASSENGERS ALLOWED ON BOARD IS 493 UNTIL ADDITIONAL PFD ARE ON BOARD.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Fire Fighting
Issued 17 February 1993 Resolved
COMPLETE 6 YEAR SERVICING ON ALL B-II DRY CHEMICAL EXTINGUISHERS IN ACCORDANCE WITH NFPA-10.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Lifesaving
Issued 10 March 1992 Resolved
STENCIL VESSEL NAME ON AFT MAIN DECK RING BUOY.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 10 March 1992 Resolved
RELABEL SECONDARY BILGE MANIFOLD VALVES IN #3 COMPARTMENT.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 10 March 1992 Resolved
RECONNECT BILGE SUCTION LINE ON PRIMARY BILGE SYSTEM IN #3 COMPARTMENT.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 10 March 1992 Resolved
LABEL BILGE VALVE REACH RODS IN MAIN DECK GALLEY STORAGE TO IDENTIFY LOCATION.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Fire Fighting
Issued 10 March 1992 Resolved
REMOUNT LOOSE B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 10 March 1992 Resolved
MODIFY BILGE SUCTION VALVE REACH ROD IN FOREPEAK TO PREVENT LIFTING.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Accommodation/Occupational Safety
Issued 10 March 1992 Resolved
INSTALL MARPOL V PLACARDS AS PER 33 CFR 151.59, AT LEAST ONE PER DECK.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Lifesaving
Issued 10 March 1992 Resolved
PROVIDE 07 ADDITIONAL ADULT LIFE TYPE I LIFEJACKETS. UNTIL PROVIDED, TOTAL PERSON CAPACITY IS LIMITED TO 528.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Electrical
Issued 10 March 1992 Resolved
INSTALL WEATHERPROOF ELECTRICAL RECEPTACLE ON TOP DECK FOR CALLIOPE AIR PUMP.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Documentation
Issued 10 March 1992 Resolved
OBTAIN VALID FCC STATION LICENSE AND POST IN PILOT HOUSE.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Electrical
Issued 10 March 1992 Resolved
REMOVE ELECTRICAL WIRE NUTS IN PANEL BENEATH PILOT HOUSE IN STORAGE ROOM. REPLACE WITH UL APPROVED CRIMP CONNECTORS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Construction/Loadline
Issued 11 June 1986 Resolved
(46 CFR 182.25-10(A))PROVE TO THE SATISFACTION OF THE MARINE INSPECTOR THAT THE (2) TWO REQUIRED BILGE PUMPS ARE CAPABLE OF PUMPING 50 GAL. PER-MINUTE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Fire Fighting
Issued 11 June 1986 Resolved
(46 CFR 181.10-5(A))PROVIDE A HAND OPERATED PORTABLE FIRE PUMP HAVING A CAPACITY OF AT LEAST 5 GAL.PER-MINUTE.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Fire Fighting
Issued 11 June 1986 Resolved
(46 CFR 181.10-1(C))PROVIDE (1) ONE PRIMARY FIRE FIGHTING PUMP CAPABLE OF SUSTAINING NOT LESS THAN 50 GAL. PER-MINUTE AT A PRESSURE OF NOT LESS THAN 60 POUNDS PER SQUARE INCH.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986

Casualty record · 1

12 November 2016Routine · role: Involved in a Marine Casualty · activity 6050747
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.