Inspection history · 38
25 July 2026
Annual Inspection · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8446958
18 October 2025
Damage Survey · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8245248
4 July 2025
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8175120
4 July 2025
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8183426
25 September 2024
Drydock Extension · Examination of Repairs · Construction Oversight · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7967559
26 December 2023
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7847103
18 October 2023
Drydock Extension
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7810485
20 September 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7778492
24 July 2023
In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7751207
21 November 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7590627
16 June 2022
DAPI Audit · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7478145
7 June 2022
In-Service Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7471117
27 January 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7376184
20 April 2021
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7188929
21 October 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7069937
17 July 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7030168
16 October 2019
COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6835987
25 April 2019
Administrative Inspection · Drydock Extension
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6670357
9 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6507055
24 August 2017
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6310711
20 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5947479
22 July 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5194420
22 October 2014
Administrative Inspection · DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5010565
19 May 2014
Administrative Inspection · Deficiency Check · COI Inspection · Drydock Extension
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4862592
19 May 2014
Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5010641
26 June 2013
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4632621
27 June 2012
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4358073
27 July 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4094959
2 September 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3864389
25 August 2010
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3822757
29 January 2009
Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3402188
25 October 2004
Administrative Inspection
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2227529
19 July 2004
Deficiency Check · Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2145185
22 October 2003
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1933493
31 July 2003
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1869133
22 July 2002
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1650154
3 July 2002
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1644662
10 May 2001
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1403390
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2026
Resolved
Vessel ring buoy reflective tape, grab line, and lettering wasted. Replace reflective tape, grab line and lettering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2026
Resolved 30 July 2026
Resolution: Vessel replaced tape, grab line and lettering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2026
Resolved
Vessel POC reported main propulsion hydraulic line failure. Replace with SAEJ-1942 approved approved metallic line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2026
Resolution: Replaced hydraulic drive line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2026
Resolved
Aft void bilge suction failed to remove water from the space. Vessel will be equipped with an additional de-watering pump until primary suction is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 July 2026
Resolution: Vessel provided adequate bilge suction for the space.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2025
Resolved
Each portable fire extinguisher must be of an approved type and acceptable to the OCMI. Vessels fire extinguishers did not received their annual servicing for 2025. All fire extinguishers must be in an approved manufactures bracket and mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 31 October 2025
Resolution: Annual servicing was conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2024
Resolved
Vessels that operate in fresh water at least six months in every 12 month period since the last drydock examination must be examined in accordance with the intervals set forth in Table 91.40-3(b) of this section. Vessels Dry Dock date has expired, vessel will need to have a Dry Dock inspection prior to being placed into operational service.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 March 2025
Resolution: VSL completed DD/ISE inspection and return to service.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 September 2024
Resolved
Port side of vessel near the connection point has pitting that needs to have some UT shots taken to determine the area that needs to be replaced.
NVIC 7-68 & ABS Rules for non-destructive testing requirements. Also refer to ASTM F2991-13 Section 8 for workmanship, finish, and appearance of repairs.
Action required: 60 - Rectify deficiencies prior to movement
Due 3 January 2025
Resolved 5 March 2025
Resolution: VSL c/r damaged area conducted NDT and returned to sevice
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 September 2024
Resolved
Operator shall cut out STBD hull 20" high and 29' long mid ship and renew with new steel.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 5 March 2025
Resolution: Vessel had 20"x 29" insert installed in sideshell. Welds were tested with dye penetrant. SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2022
Resolved
MIS submission for 2021 year was not submitted by the required deadline of March 15th 2022.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 8 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 January 2022
Resolved
Each Life jacket must be marked with type I retroreflective material. Vessel had 6 life jackets and 1 ring buoy with faded retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2022
Resolved 1 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 October 2020
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. No donning procedures found on the port side near 02 stowage locations of the life jackets. Post instructions near these 2 locations.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2020
Resolved 17 November 2020
Resolution: Received email containing pictures of donning placards mounted near life jacket boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2014
Resolved
Found cord to engine heater (115vac) spliced and outer insulator/shielding cut; replace with no splice or make splice in a junction weather proof box. Recommend spooled extension cord be of larger wire gauge for the long run.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: found extension cord removed and cord to engine heater was replaced.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 19 May 2014
Resolved
Found wiring to navigation lights cut or exposed. Replace wire at transition from tow boat to barge and correctly install exposed wires and splice inside lighting fixtures on port and starboard running lights.
Action required: 705 - Other - as specified
Due 21 June 2014
Resolved 27 August 2014
Resolution: Corrected and ran wire in conduit.
Fire Fighting › Fire Hoses › Condition
Issued 19 May 2014
Resolved
Found 50' fire hose was leaking. Remove all suspect leaking hoses from ferry and replace with new or tested fire hose.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: Replaced with new hose and reel. All defective hoses were removed.
Lifesaving › Lifebuoys › Serviceable
Issued 19 May 2014
Resolved
Found lifebuoy water light not working; replace battery with approved battery.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: Replaced entire light and battery.
Engineering › Bilge Water Management System › Not Operational
Issued 19 May 2014
Resolved
Found bilge system not operational; show proper operation of bilge system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: Witnessed proper operation of bilge system.
Engineering › Compressed Air System (control) › Hose
Issued 19 May 2014
Resolved
Found port fwd ramp pneumatic ram control lines chaffing during operation; secure air hoses for pneumatic ram to vessel support.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: pneumatic control lines secrued by support to rail.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 May 2014
Resolved
Found no service tag on tow boat fire extinguisher; provide letter of service.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 27 August 2014
Resolution: Found all fire extinguishers satisfactory serviced.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 June 2012
Resolved
Ensure proper Employee Assistance Program (EAP) provider information is displayed in Pilothouse and in Drug policy. Provide USCG inspector with 2011 MIS report.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 5 July 2012
Resolution: Vsl rep provided updated EAP information and drug policy along with 2011 MIS report.
Documentation › Logs/Records › Logbook (official)
Issued 27 June 2012
Resolved
Document proper training of crew for abandon ship, man overboard, and fire fighting. These trainings and drills need to be completed monthly and training conducted for each new crew member.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 5 July 2012
Resolution: Vsl rep provided emergency procedures and a plan to complete trainings for crew members.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2012
Resolved
Replace expired Eyewash, Burn cream/spray, and antiseptic.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 7 August 2012
Resolution: Replaced expired items.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 27 July 2011
Resolved
Paint reference marks on the hull a contrasting color so they are visible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 27 June 2012
Resolution: Reference marks were painted in contrasting color.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2011
Resolved
Replace shields for the port and starboard side lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 27 June 2012
Resolution: Oberserved proper operation of side lights.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2009
Resolved
Prove proper operation of floating light attached to lifebuoy.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 January 2009
Resolved
Properly mark lifebuoy.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 January 2009
Resolved
Properly mark lifejacket lockers with size and quantities.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 January 2009
Resolved
Provide proof that all fire extinguishing equipment has had annual servicing.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 January 2009
Resolved
Install fire extinguisher bracket for extinguisher on bow of tow boat.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Engineering › Bilge Water Management System › Valve
Issued 29 January 2009
Resolved
Prove proper operation of remote operated bilge suction valve forward of collision bulkhead.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Operations/Management › Pollution
Issued 31 July 2003
Resolved
Remove all oily waste and residue from engine room bilges. LEGACY COMPONENT DESC: Retention of Oily Mixture
Condition: Improper/Lack of Maintenance
Due 30 August 2003
Resolved 21 October 2003
Resolution: All oily waste removed from engine room bilges.
Engineering › Pressure Vessel
Issued 31 July 2003
Resolved
Provide new air gauge for air receiver at the tank. LEGACY COMPONENT DESC: Pressure Gauge
Condition: Damaged By Earlier Event
Due 30 August 2003
Resolved 21 October 2003
Resolution: New air gauge installed on air receiver.
Operations/Management
Issued 31 July 2003
Resolved
Provide and use wheel chocks to block wheels of first and last vehicle IAW 46 CFR 185.340(b).
Due 30 August 2003
Resolved 21 October 2003
Resolution: Wheel chocks in use.
Stability › Intact Righting Energy › General
Issued 31 July 2003
Resolved
Obtain stability letter and post in pilot house.
Due 30 August 2003
Resolved 19 July 2004
Resolution: Hand delivered signed stability letter to vessel.
Lifesaving › Lifejacket/PFD (General)
Issued 3 July 2002
Resolved
LABEL LOCATIONS OF ADULT/CHILD PFD WITH QUANTITIES. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 17 July 2002
Resolution: LABELS INSTALLED IDENTIFYING LOCATIONS.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 July 2002
Resolved
REPAIR/REPLACE DIESEL ENGINE TACHOMETER. LEGACY COMPONENT DESC: Guage
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 30 July 2002
Resolution: Installed electrronic eng tach., operational tests satisfactory.
Navigation › Collision/Grounding Avoidance
Issued 3 July 2002
Resolved
REPAIR BENT SUPPORT BRACKET THAT SUPPORT STERN LIGHT TO ENSURE LIGHT REMAINS LEVEL. LEGACY COMPONENT DESC: Navigation Lights
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 17 July 2002
Resolution: ANGLE BRACKET INSTALLED
Engineering
Issued 10 May 2001
Resolved
REPAIR/RENEW GASKETS FOR ENGINE COOLING SYSTEM AND LUBE OIL SYSTEM.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 10 May 2001
Resolved
RENEW EXPIRED MEDICATIONS IN FIRST AID KIT.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 10 May 2001
Resolved
PROVIDE LIFEJACKET DONNING PROCEDURES PLACARD IN VICINITY OF LIFEJACKET STAORAGE AREAS.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Engineering
Issued 10 May 2001
Resolved
REPAIR/REPLACE LUBE OIL PRESURE AND WATER TEMP GUAGES ONBOARD TOW VESSEL.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Documentation
Issued 10 May 2001
Resolved
PROVIDE PERMANENT MAXIMUM DRAFT REFERENCE MARKS ON HULL.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 10 May 2001
Resolved
POST NO SMOKING SIGNS ON DECK.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Accommodation/Occupational Safety
Issued 10 May 2001
Resolved
PROVIDE 4" INCH SPACING ON RAIL LIFELINES ALONG PORT AND STARBOARD DECKS.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Engineering
Issued 10 May 2001
Resolved
PROVIDE MACHINERY GUARDS OVER ALTERNATOR BELT AND PROVIDE INSULATION OVER ENGINE EXHAUST ABOARD TOW VESSEL.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Construction/Loadline
Issued 10 May 2001
Resolved
DEMONSTRATE PROPER OPERATION OF FORWORD AND AFT LOADING RAMPS.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Lifesaving
Issued 10 May 2001
Resolved
PROVIDE NAME OF VESSEL ON LIFERING.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001