MAURY USCG vessel records
← All vessels

ST 9

Built
1985
Last inspected
10 March 2008
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 March 2008
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1985–2008)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

252158
Flag
UNITED STATES
Maury page id
psix-252158

Documentation record

Registered dimensions (L × B × D)195.0 ft × 42.0 ft × 14.3 ft
Registered tonnagegross 868 / net 729
ITC dimensions (L × B × D)195.0 ft × 42.0 ft × 14.3 ft
ITC tonnagegross 868 / net 729
BuilderSUNDIAL MARINE TUG&BARGE · TROUTDALE, OR, UNITED STATES · built 1985
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it868 - Convention (Subpart B), Gross Ton
729 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 46 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

POINT VICENTE Towing Vessel · MISLE 145511 · 10 June 2005 · activity 2591546KEEGAN FOSS Towing Vessel · MISLE 319713 · 10 June 2005 · activity 2591546

Inspection history · 46

10 March 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3161541
18 September 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2781239
8 May 2006 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2640624
4 November 2005 Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2534320
10 June 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2591546
20 May 2005 Internal Structural Exam · Annual Inspection · Cargo Tank Internal
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2384123
21 April 2005 MTSA Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2340817
18 November 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2243931
8 November 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2235698
4 October 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2212986
20 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2047468
29 July 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1860529
25 June 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1821616
5 February 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1740465
23 December 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1722492
3 April 2002 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602850
10 May 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1408743
12 June 2000 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369723
12 May 1999 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388798
7 May 1998 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427509
8 May 1997 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1460954
10 July 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371473
23 August 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1188799
29 June 1995 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409317
3 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869335
24 March 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1166722
21 October 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 482505
3 May 1993 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1151778
5 May 1992 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 950267
27 March 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 181675
11 September 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 477452
20 May 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 918898
5 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911265
3 May 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911633
29 June 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 913143
1 May 1990 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931771
5 May 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1203406
6 April 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 452987
5 May 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1346531
22 September 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 450941
19 May 1987 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1025105
8 May 1987 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1328454
3 December 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 466548
12 June 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1009480
8 May 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 993973
9 May 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 983966

Deficiency record · 16

Electrical › Lighting (service) › Lighting Branch Circuit
Issued 8 May 2006 Resolved
Install a blank where missing in the Lighting distribution box in the vsl's office.
Due 8 May 2006
Resolved 8 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2006 Resolved
Repaint nav light screens flat black.
Due 8 May 2006
Resolved 8 May 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 8 May 2006 Resolved
Plug/fill holes in fwd bulkhead of cargo pump engineroom.
Due 8 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 May 2006 Resolved
General housekeeping - clean hydraulic oil from fwd rake void.
Due 8 May 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Hull Plating
Issued 4 October 2004 Resolved
Prior to operating vessel, have Coast Guard Marine Inspector perform a Credit Drydock Exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 8 November 2004
Resolution: Dry Dock completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 25 June 2003 Resolved
Perform annual test/check for accuracy cargo pump discharge pressure gauge. LEGACY COMPONENT DESC: Pressure/Vacuum Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 29 July 2003
Resolution: Provided documentary proof that the cargo pump discharge guages had been tested satisfactorily.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 25 June 2003 Resolved
Perform annual test of cargo pump relief valve. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 29 July 2003
Resolution: Provided documentary proof from a 3rd party testing company: WEST COAST VALVE SERVICES from Long Beach, CA.
Deck/Cargo
Issued 12 May 1999 Resolved
PROVE PROPER OPERATION OF PORT AND STBD CARGO PUMP RELIEF VALVES.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Documentation
Issued 29 June 1995 Resolved
Obtain valid load line certificate before going beyond the boundary line.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Documentation
Issued 29 June 1995 Resolved
Obtain a corrected tonnage certificate and have the certificate of documentation updated.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Unknown
Issued 29 June 1995 Resolved
Provide approved plans for modifications made to the vessel.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Electrical
Issued 3 May 1991 Resolved
INSTALL EXPLOSION PROOF LIGHTING FIXTURES IAW 46CFR111.105-32(L) ON FWD BKHD OF DECKHOUSE NLT 17MAY91.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Deck/Cargo
Issued 8 May 1987 Resolved
INSTALL FLAME GUARD ADAPTOR KITS TO PLASTIC RACOR FUEL FILTER BOWLS ON CARGO PUMP PRIME MOVERS.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Construction/Loadline
Issued 8 May 1987 Resolved
COMPLETE A SATISFACTORY CREDIT DRYDOCK.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Navigation
Issued 8 May 1987 Resolved
PROVIDE AND POST FCC RADIO STATION LICENSE FOR BARGES VHF RADIO.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Deck/Cargo
Issued 8 May 1986 Resolved
INSTALL REMOTE SHUTDOWN FOR CARGO PUMP ENGINE.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986

Recorded names · 1

BMC 10 (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.