SPIRIT OF ADVENTURE

SPIRIT OF ADVENTURE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 133 inspections since 1985, most recently in May 2026, along with 143 deficiencies and 4 casualty investigations between 2004 and 2013.

Records from 1985 to 2026. Most recent: inspection, 5 May 2026.

Built
1985
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5978
252975
Flag
UNITED STATES
338490000
Maury page id
psix-252975

Inspections, by type

…with no type recorded26
Years with a record 40 calendar years (1985–2026)
The 133 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)86.6 ft × 31.2 ft × 9.2 ft
Registered tonnagegross 90 / net 62
ITC dimensions (L × B × D)86.6 ft × 31.2 ft × 9.2 ft
ITC tonnagegross 262 / net 96
BuilderNICHOLS BROS BOAT BLDRS · FREELAND, WA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
262 - Convention (Subpart B), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
96 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5978MMSI 338490000 · active · compulsorily equipped · granted 17 December 2025, expires 5 February 2036
WDC3422MMSI 338490000 · expired · compulsorily equipped · granted 4 January 2005, cancelled 7 March 2015
WCW7790MMSI not assigned · expired · compulsorily equipped · granted 31 July 1996, cancelled 30 September 2006
WCV3011MMSI not assigned · expired · compulsorily equipped · granted 30 October 1995, cancelled 7 January 2006
WAM3815MMSI not assigned · expired · compulsorily equipped · granted 4 April 1995, cancelled 6 August 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CATALINA JET Passenger (Inspected) · MISLE 469142 · 21 October 2003 · activity 1935513

Inspection history · 133

5 May 2026 Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8367735
24 September 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8240853
21 August 2025 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8215176
23 April 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8118122
1 August 2024 In-Service Inspection · ACP Additional Oversight – Risk Assessment
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7975523
4 June 2024 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7926457
14 September 2023 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7794211
18 April 2023 In-Service Inspection · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7671336
31 August 2022 Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7548233
6 October 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7328380
15 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7312967
26 August 2020 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7043448
28 April 2020 Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6973366
20 August 2019 Examination of Repairs · COI Inspection · MTSA Verification · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6789836
11 June 2019 Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6726891
10 April 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6660952
3 May 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6441744
20 March 2018 Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6373277
4 January 2018 Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6334450
23 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6292886
10 April 2017 Administrative Inspection · Annual Inspection · Deficiency Check · Plan Review (Other than "T")
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6129849
19 August 2015 Examination of Repairs · Drydock Exam · Deadweight Survey · Plan Review "T" Boat · Internal Structural Exam · MTSA Verification · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5228963
1 May 2014 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4844420
24 March 2014 Drydock Exam · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4831376
8 May 2012 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4302199
7 December 2011 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4203744
23 August 2011 Damage Survey · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4126305
1 August 2011 Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4288259
30 March 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3715342
16 April 2009 Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3451555
1 April 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3448933
29 April 2008 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3195392
16 January 2008 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3131793
3 July 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2974805
26 June 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2974677
9 April 2007 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2904290
25 October 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2807960
18 August 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752016
19 April 2006 Hull Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2628822
14 April 2006 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2619962
13 December 2005 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2550912
3 November 2005 In-Service Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2531725
5 August 2005 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2452483
14 June 2005 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2390401
13 June 2005 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2389183
14 March 2005 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2310115
28 February 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2301312
8 November 2004 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2237061
26 October 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2228961
21 June 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2106029
4 June 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2091254
8 April 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2038746
9 February 2004 Deficiency Check · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2003151
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970880
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970943
21 October 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1935513
29 April 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1781966
6 March 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1753696
24 April 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1609072
2 January 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1491994
19 May 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 43759
8 May 2001 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1063735
2 May 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426585
5 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362148
3 May 2000 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389074
1 May 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369647
6 September 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 175978
14 June 1999 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1083604
2 June 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 808846
4 May 1999 Deadweight Survey · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470772
1 March 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 797205
6 May 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1450156
13 February 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 776729
20 January 1998 Hull Examination · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1428886
30 April 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 779616
30 April 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431775
21 April 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416518
3 October 1996 Damage Survey · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359265
13 September 1996 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1268305
11 September 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 951124
11 September 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1266150
5 September 1996 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1355929
26 August 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 134334
11 May 1996 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1083374
8 May 1996 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1435767
18 April 1996 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1081995
18 December 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1438385
4 May 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1029216
14 April 1995 Deficiency Check · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1443564
30 March 1995 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1462434
19 December 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1432865
28 November 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1424026
3 October 1994 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869406
14 July 1994 Examination of Repairs
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1400068
10 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1367041
16 February 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389770
14 May 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 50224
29 April 1993 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1401664
18 September 1992 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1420668
14 September 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 165753
9 September 1992 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 938421
7 September 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 57375
11 May 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 950948
23 December 1991 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1270686
18 October 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 9646
30 May 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 940591
25 May 1991 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 924534
26 April 1991 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999388
2 November 1990 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 901487
10 October 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1217721
22 August 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1220433
12 April 1990 Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 908512
22 November 1989 Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916306
19 July 1989 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1033632
26 June 1989 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1350680
15 June 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1030574
17 May 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348252
22 July 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1036621
2 June 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348525
20 April 1988 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349275
3 November 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330863
9 September 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004007
8 June 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1336608
26 May 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1026762
8 September 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 966082
13 June 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299551
3 June 1986 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1297342
19 May 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292642
21 January 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995295
19 December 1985 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988602
22 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987839
13 September 1985 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987496
7 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 985634

Deficiency record · 143

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 April 2025 Resolved
The fire control plan must show escape the location of fire protection equipment. Vessel fire control plan does not reflect required portable fire extinguishers and UL ratings in accordance with 46CFR118.500(b). 46CFR116.530
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2024 Resolved
Replace all expired items in both first aid kits.
Action required: 10 - Deficiency Rectified
Due 4 June 2024
Resolved 4 June 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2024 Resolved
Prove proper operation of fuel shut off valves for both sides
Action required: 10 - Deficiency Rectified
Due 4 June 2024
Resolved 4 June 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2024 Resolved
Replace all combustible waste receptacles with non-combustible waste receptacles with no openings in the sides or bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 2 July 2024
Resolution: Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2024 Resolved
Replace wore/torn Starboard side top deck lifering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 2 July 2024
Resolution: Rectified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2023 Resolved
All electrical equipment and circuits must be clearly marked. All power sources and distribution systems need to be properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 11 May 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2023 Resolved
Each circuit breaker must meet UL 489 and be of the manually reset type designed for switching duty if the breaker is to be used as a switch. The deck lighting circuit breakers are being used as switches.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 11 May 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2023 Resolved
Overcurrent devices capable of carrying a minimum of 125% of the full-load current of the motor it is protecting should be used for motor running overcurrent. The 10hp bilge and fire pumps both draw an average of 25A at start up but the circuit breakers installed for both are 50A.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 11 May 2023
Resolution: Corrected.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 19 April 2023 Resolved
A fire and safety plan must be posted on the vessel and visible to all passengers. The current plan is needs to be updated to reflect the stowage and general arrangement changes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 11 May 2023
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 December 2019 Resolved
Repair cracked welds on handrails on bow.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2020
Resolution: Rails repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2019 Resolved
Void 1P found three stitch welds cracked on inboard long #6 from bottom. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 30 April 2019
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2019 Resolved
Void 1P inboard long #7 from bottom fractured in two places. Repair or crop/renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 30 April 2019
Resolution: Repaired
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 May 2018 Resolved
Low risk service space on main deck (concessions area) has oven equipment that exceeds 250F, making the existing condition a high risk service space. Provide proper structural fire protection for a high risk service space IAW subchapter K, or remove existing oven equipment and replace with equipment that does not exceed 250F. Rectify within 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 3 May 2018
Resolution: Ovens were replaced with equipment that does not exceed 250F.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 3 May 2018 Resolved
Reinstall lagging over dry exhaust on both engines. Lagging should cover all portions of the dry exhaust. Rectify within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 3 May 2018
Resolution: Cleared on 835 on 03MAY18, but never cleared out of MISLE
Stability › Weathertight Integrity › General
Issued 3 May 2018 Resolved
Provide proper operation of self-closing doors on 2nd deck. Doors should auto close and latch on exterior bulkheads. Rectify within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 11 June 2019
Resolution: Verified operation of doors
Lifesaving › Lifefloat › Serviceable
Issued 3 May 2018 Resolved
Provide properly-serviced 50-person liferaft on 3rd deck. Existing liferaft has not met serviceing requirements. Reduced passenger count until proper liferaft is onboard. Max 200 total persons.
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 11 April 2019
Resolution: During 2019 annual, vessel was equipped with proper primary life saving equipment.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 April 2018 Resolved
Provide dripshields on electrical panels in both engine rooms and both generator rooms
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 11 April 2019
Resolution: Verified during 2019 Annual
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 April 2018 Resolved
Submit plans and spec sheets to MSC on fuel tank sight tubes and valves. Close off valves until approved.
Action required: 705 - Other - as specified
Due 11 May 2018
Resolved 11 April 2019
Resolution: Plans were submitted
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 April 2018 Resolved
Consult with an electrician and provide proposal to correctly install wiring on gen room electrical panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2018
Resolved 11 June 2019
Resolution: Wiring installation sat.
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2017 Resolved
Reseal bolt in Void #2 ceiling
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 26 April 2017
Resolution: Resealed satisfactorily
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2017 Resolved
Reweld railing starboard side aft
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 16 June 2017
Resolution: Cracked welds repaired
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2017 Resolved
Double clamp raw water intake hoses for both generators
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 26 April 2017
Resolution: Proper clamps installed
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 April 2017 Resolved
Update and post fire control plan
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 15 June 2017
Resolution: FCP was updated and approved
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 April 2017 Resolved
Separate child and adult life jackets
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 26 April 2017
Resolution: life jacket stowage is now acceptable
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 May 2016 Resolved
Complete electrical installation in accordance with MSC approved drawings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2016
Resolution: Company updated drawing to match installation. MSC approved 7/11/16
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 May 2016 Resolved
Re-submit fixed firefighting system drawing to MSC for approval.
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 20 July 2016
Resolution: MSC approved revised drawings on 7/20/16.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 May 2016 Resolved
Fixed Firefighting System: provide updated 'instructions to operate' placards and warning plates at sirens
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Resolution: placards and signs have been updated
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 25 May 2016 Resolved
Complete installation of Fire Detection System and test in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2016
Resolution: Installation and tests were satisfactory
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 25 May 2016 Resolved
Ensure fixed fire fighting system works as intended - shuts down ventilation and closes dampers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2016
Resolution: Tested satisfactory
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 May 2016 Resolved
Complete installation of Marine Sanitation Device and associated piping in accordance with MSC approved drawings.
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 2 June 2016
Resolution: Installation verified
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 May 2016 Resolved
Seal watertight bulkhead penetrations in engine rooms and generator rooms with fire rated sealant.
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Electrical › Electric Supply System (service) › Cable
Issued 25 May 2016 Resolved
Install metal supports 24" apart to hold wire and cabling in engine rooms and generator rooms
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 2 June 2016
Resolution: supports installed
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 May 2016 Resolved
Complete installation of water heater.
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Resolution: water heater has been fully installed
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 25 May 2016 Resolved
Complete installation of restrooms
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Restroooms are completely installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 25 May 2016 Resolved
Replace fuel vent flame screens (port & starboard)
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Flame screens installed
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 25 May 2016 Resolved
Test emergency power in presence of CG Marine Inspector
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Resolution: Emergency power tested satisfactory
Communications › Public Address System › Loudspeaker
Issued 25 May 2016 Resolved
Complete installation of speakers on outside deck for PA system
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Resolution: Speakers installed and tested satisfactory
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 May 2016 Resolved
Properly label bilge high level alarms on bridge
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 2 June 2016
Resolution: Labels have been resecured to alarm panel.
Construction/Loadline › Structures › Machinery Space Opening
Issued 25 May 2016 Resolved
Repair latch on port generator door
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 2 June 2016
Resolution: Door repaired
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 May 2016 Resolved
Provide garbage management plan with procedure specific to this vessel
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 2 June 2016
Resolution: Adequate garbage management plan is onboard
Lifesaving › Embarkation Appliances/Stations › Handholds
Issued 25 May 2016 Resolved
Provide new clips for Jason's cradle
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 2 June 2016
Resolution: Clips have been replaced
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 May 2016 Resolved
Provide a lifeline for lifebuoy (60ft)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2016
Resolution: lifeline provided
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 May 2016 Resolved
Provide a fire control and safety plan
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 27 June 2016
Resolution: Received draft FCP
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 May 2014 Resolved
Provide Drip-proof protection for all distribution panels in machinery spaces
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 6 January 2015
Resolution: Vessel will be overhauling engine room, to include wiring, after vessel sank.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 May 2014 Resolved
Make permanent repairs to starboard main engine exhaust relief port.
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 6 January 2015
Resolution: Vessel will be overhauling engine room after vessel sank.
Construction/Loadline › Hull › Bottom Plating
Issued 23 August 2011 Resolved
Crop and renew hull plating on the stbd hull in way of the #2 hold on the outboard side as per the email proposal from the operator to the CG. Repairs to be completed prior to getting underway and to the satisfaction of the attending CG marine inspector.
Action required: 705 - Other - as specified
Resolved 27 August 2011
Resolution: Duty Marine Inspector attended vessel and witnessed satisfactory repairs to the #2 hold and witnessed a satisfactory dye pen test both inside and outside of the hold. //S// [name withheld]
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 April 2009 Resolved
Remove trash/debris, and oil from bilges.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Bilges cleaned.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 April 2009 Resolved
Properly mount fire ext Port Eng Rm, port side.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Extinguisher mounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 April 2009 Resolved
Properly install battery box covers.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Covers installed.
Construction/Loadline › Hull › Transverse Frame
Issued 16 April 2009 Resolved
Properly plug bulkhead penetration, port E/R, aft.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Plug installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2009 Resolved
Properly secure junction box port E/R aft.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Box secured.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 April 2009 Resolved
Make proper repairs or replace deck light, aft 2nd deck.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Light renewed.
Engineering › Bilge Water Management System › Not Operational
Issued 16 April 2009 Resolved
Demonstrate proper operation of the port lazarette bilge alarm.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 21 May 2009
Resolution: Conducted op test, sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 April 2009 Resolved
Renew/replace or blank off open location in breaker panel, located in the galley/concession area. IAW 46 CFR 183.10-10
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 21 May 2009
Resolution: Blank installed.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 April 2009 Resolved
Remove excess electrical corrosion on emergency bottery box, stbd side brige wing.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Battery terminals cleaned and preserved.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 April 2009 Resolved
Properly secure fire extinguisher main deck, stbd side aft.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Extinguisher secured.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 16 April 2009 Resolved
Properly secure the PA speaker in the galley.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Speaker mounted.
Lifesaving › Lifebuoys › Stowage
Issued 16 April 2009 Resolved
Install the proper length of line to the port life ring light.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Line of the correct length installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 April 2009 Resolved
Provide proper lagging/protective cover for STBD MDE exhaust.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Lagging installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 16 April 2009 Resolved
Properly secure fuel leak STBD MDE FWD inboard side at the cooler.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Leak secured.
Electrical › Electric Supply System (service) › Cable
Issued 16 April 2009 Resolved
Properly secure, wire run, STBD E/R OVHD.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Wires secured properly.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 16 April 2009 Resolved
Properly label all emergency excapes.
Action required: 705 - Other - as specified
Resolved 17 April 2009
Resolution: Emergency exits labled.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 April 2009 Resolved
Visual inspection of exhaust piping over-boards port side showed major pitting. Owner/operated will be fabricating a new exhaust pipe for overboards port side.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 10 April 2009
Resolution: Visual Inspected conducted of welds and fabrication of schd 80 6061 aluminum alloy pipe. Conducted NDT of all through hull penetration welds w/dye penetrate "leak test" method.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 April 2009 Resolved
Visual inspection of exhaust piping over-board stbd showed major pitting. Owner/operated will be fabricating a new exhaust pipe for over boards starboard side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 10 April 2009
Resolution: Visual Inspected conducted of welds and fabrication of schd 80 6061 aluminum alloy pipe. Conducted NDT of all through hull penetration welds w/dye penetrate "leak test" method.
Construction/Loadline › Hull › Weld
Issued 26 June 2007 Resolved
Cracked weld in port forward collision void #6 center overhead
Due 27 July 2007
Resolved 3 July 2007
Resolution: Verified completed.
Construction/Loadline › Hull › Weld
Issued 26 June 2007 Resolved
cracked weld port #2 void, #4 from portside on bulkhead (frame 13)
Due 27 July 2007
Resolved 3 July 2007
Resolution: Verified completed.
Construction/Loadline › Hull › Weld
Issued 26 June 2007 Resolved
cracked skip welds 2nd port side longitudinal between 1st and 2nd frame (aft part of #2 port void)
Due 27 July 2007
Resolved 3 July 2007
Resolution: Verified completed.
Construction/Loadline › Hull › Weld
Issued 26 June 2007 Resolved
Support for bilge intake cracked in #2 port void
Due 27 July 2007
Resolved 3 July 2007
Resolution: Verified completed.
Stability › Watertight Integrity › General
Issued 26 June 2007 Resolved
3 of 4 butterfly valves for the sea chest need to be replaced.
Due 27 July 2007
Resolved 3 July 2007
Resolution: Verified installation of 04 new valves.
Electrical › Lighting (emergency) › Outlet Box
Issued 9 April 2007 Resolved
Prove proper operation of emergency lighting prior to carrying passengers at night.
Action required: 705 - Other - as specified
Resolved 11 April 2007
Resolution: proved proper operation of emergency lighting
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2006 Resolved
Remove (2) dead end wires fwd stbd E/R main engine bilges.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified removed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 April 2006 Resolved
Label switches in control panel inboard mid Stbd E/R.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified labeling in panels.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 April 2006 Resolved
Install machinery guards for Stbd Mn Engine fan belt pulley and aft shafting, port mn engine and stbd Genset pulley.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified all machinery guarding in place and functional.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 14 April 2006 Resolved
Install missing 12 oclock and 6 oclock bolting for stbd shaft packing gland in stbd e/r.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified bolt installation.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 April 2006 Resolved
Correct faulty A-60 insulation in the following locations: overhead aft mn engine stbd e/r; ovhd outside entrance to port e/r; aft port e/r outboard side (3) each and (1) mid aft overhead inboard port e/r; port genset room ovhd.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified all A-60 insulation discrepancies corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2006 Resolved
Remove dead end wires port e/r outboard side (3) each and (1) each fwd inboard side.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified removed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2006 Resolved
Renew hose and clamp to salt water cooling port genset.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Witnessed new hose with clamps in place, sat.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 April 2006 Resolved
Install A-60 insulation on old water tank covers port and stbd.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified insulation in place.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2006 Resolved
Remove dead end wiring stbd inboard genset room bottom area.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified wiring removed.
Construction/Loadline › Structures › Scuttle
Issued 14 April 2006 Resolved
Connect securing lines to fwd stbd and port hatches.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified hatch lanyards in place.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 April 2006 Resolved
Submit copy of calibration test of the CO2 weighing scale by Southeast Extinguishing service.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Noted calibration certificate of servicing company.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 14 April 2006 Resolved
Provide hull shock mount maintenance plan for review.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Reviewed shock mount maintenance plan, all sat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 14 April 2006 Resolved
Provide current liferaft certificates for all liferafts onboard and prove proper installation of rafts.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Reviewed current L/R certificates and verified proper installation.
Engineering › Diesel Engine (auxiliary) › Block
Issued 14 April 2006 Resolved
Prove proper operation of port s/s generator.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Test ran port genset under load for 30 minutes, sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 April 2006 Resolved
Prove proper operation of Bilge high level alarms.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Tested all bilge alarms, sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2006 Resolved
Provide current firefighting equipment certification for fixed system and portable extinguishers.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Reviewed current fixed firefighting certification.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 April 2006 Resolved
Provide letter of compliance with drug testing requirements showing dates of validity and crew included.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Reviewed current drug testing participation letter for compliance noting crew members aboard, all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2006 Resolved
Provide current navigation chart for route.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified current (''05) Nav chart for route onboard.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 14 April 2006 Resolved
Provide additional embarkation aid for life rafts (opposite side).
Due 14 May 2006
Resolved 12 May 2006
Resolution: Vessel provided emergency embarkation ladder for recovery of person from water, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2006 Resolved
Provide current eye wash solution for first aid kit in galley.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified current eye wash onboard.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 April 2006 Resolved
Provide compass illumination as required for night-time ops.
Due 14 May 2006
Resolved 12 May 2006
Resolution: Verified compass illumination.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 3 November 2005 Resolved
Number of persons permitted is reduced to 140 persons until 100% lifesaving requirements can be met. Re-install the three CG approved IBA's.
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 13 December 2005
Resolution: IBA''s have been serviced and reinstalled, sat.
Lifesaving › Lifebuoys
Issued 8 April 2004 Resolved
STBD Lifering is cracked and beyond repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 26 April 2004
Resolution: Lifering was replaced with new. Verified with receipt.
Lifesaving › Lifejacket/PFD (General)
Issued 8 April 2004 Resolved
Child and adult PFDs are not physically separated within storage compartment. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 26 April 2004
Resolution: Adult and shild PFDs were physically separated with clear plastic bags. The bags are labeled child lifejackets. Verified with letter.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 April 2004 Resolved
First Aid kit not complete and out of date. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 26 April 2004
Resolution: The first aid kit was checked and is now in compliance with the CFRs. Verified with receipt.
Electrical › Electrical Distribution System (service)
Issued 6 April 2004 Resolved
Blanks not installed in openings within circuit breaker boxes. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 26 April 2004
Resolution: Blanks were placed in the circuit breakers. Verified with receipt.
Construction/Loadline › Hull
Issued 9 February 2004 Resolved
Make permanent repair as proposed to bow fairing and port hull stem.
Action required: 705 - Other - as specified
Resolved 9 February 2004
Engineering › Reduction Gearing/Clutches › Gear/Clutch Starter (electric)
Issued 21 October 2003 Resolved
Determine cause and correction of propulsion failure, provide report to OCMI.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 February 2004
Resolution: Reviewed ltr from PacNav regarding tech rep findings and maneuvering procedure.
Electrical › Lighting (emergency)
Issued 29 April 2003 Resolved
Emergency light socket is inoperable. Replace socket. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 2 May 2003
Resolution: Received fax with receipt for new light socket.
Lifesaving › Lifebuoys
Issued 29 April 2003 Resolved
2 liferings are in unsat condition. Replace both liferings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2003
Resolution: Received faxed receipt for 2 new liferings.
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
6 cracks evident in transom rain guard fo vessel. V gouge and reweld cracks. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 6 May 2003
Resolved 4 September 2003
Resolution: Def Cleared. Stern rain guard is not integral to hull. There is no chance cracks will propogate into hull of vessel.
Navigation
Issued 2 May 2001 Resolved
PROVIDE REQUIRED 406 EPIRB. VESSEL LIMITED TO NO MORE THAN 3 MILES FROM SHORE ON LIMITED COASTWISE ROUTE.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 1 May 2000 Resolved
DEMONSTRATE FIXED FIREFIGHTING SHUTDOWN OF STARBOARD MAIN ENGINE AND GENERATOR.
Condition: Unknown
Due 2 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 1 May 2000 Resolved
COMPLETE CREDIT DRYDOCK IN COMPANY WITH A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 May 2000
Resolved 3 May 2000
Engineering
Issued 1 May 2000 Resolved
DEMONSTRATE PROPER OPERATION OF STARBOARD MAIN ENGINE.
Condition: Unknown
Due 2 May 2000
Resolved 3 May 2000
Engineering
Issued 14 June 1999 Resolved
Leak in fuel line.
Condition: Unknown
Due 14 June 1999
Resolved 28 June 1999
Lifesaving
Issued 4 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 May 1999
Resolved 12 May 1999
Lifesaving
Issued 3 October 1996 Resolved
While in operation, at the halfway point of each excursion, and upon mooring up, internally inspect both #1 and #2 forward voids port and starboard for indication of seawater ingress.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Lifesaving
Issued 3 October 1996 Resolved
Record each of the inspections required in CG-835's, ident #1 and #2 in thevessel's deck log.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Construction/Loadline
Issued 3 October 1996 Resolved
Drydock vessel, and make permanent repairs to the port and starboard stem where hull is thin from beaching the vessel.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Construction/Loadline
Issued 3 October 1996 Resolved
Conduct UT or RT of suspect areas, and prove proper effective method to eliminate ALL areas contaminated by mercury, including cropping and renewing as necessary.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Lifesaving
Issued 3 October 1996 Resolved
While in operation, internally inspect bottom plate and welds in both engineroom bilges during and after each excursion. Carefully inspect for propagation or perforation of areas identified as having sustained damage from stray mercury. Keep both engineroom bilges clean.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Engineering
Issued 3 October 1996 Resolved
Make repairs to cracked liner in #8 cylinder of port main engine, and proveproper operation. Repairs to be completed prior to carrying passengers.
Condition: Unknown
Due 3 October 1996
Resolved 3 October 1996
Engineering
Issued 13 September 1996 Resolved
Make repairs to cracked liner in #8 cylinder port main engine, and prove proper operation.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Construction/Loadline
Issued 5 September 1996 Resolved
Conduct UT or RT of suspect areas, and prove proper effective method to eliminate ALL areas contaminated by mercury including cropping and renewingas necessary.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
Record each of the inspections required in CG-835's, ident #1 and #2 in thevessels deck log.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Construction/Loadline
Issued 5 September 1996 Resolved
Drydock vessel, and make permanent repairs to the port and starboard stem where hull is thin from beaching vessel.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
While in operation, internally inspect bottom plate and welds in both engineroom bilges during and after each excursion. Carefully inspect for propagation or perforation of areas identified as having sustained damage from stray mercury. Keep both engineroom bilges clean.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 5 September 1996 Resolved
While in operation, at the halfway point of each excursion, and upon mooring up, internally inspect both #1 and #2 forward voids port and starboard for indications of seawater ingress.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Lifesaving
Issued 8 May 1996 Resolved
PLACE PROPER MARKINGS & RETRO-REFLECTIVE TAPE ON RESCUE BOAT.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Electrical
Issued 8 May 1996 Resolved
ENCLOSE OR REMOVE DEAD END WIRING IN FWD DECK EQUIPMENT HOLD.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 8 May 1996 Resolved
PLACE HAMMER TO BREAK GLASS ON STBD FUEL CUT-OUT PULL BOX.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
PROVIDE CORRECT MARKINGS ON PADDLES OF RESCUE BOAT.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
CONDUCT FIRE & BOAT DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Accommodation/Occupational Safety
Issued 8 May 1996 Resolved
INSTALL TANK WATCH ON MSD TANK, INDICATING WHEN 3/4 FULL IAW 33 CFR 159._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Engineering
Issued 14 April 1995 Resolved
REPLACE FRACTURED OIL SUPPLY LINE TO B BANK TURBO CHARGER IN PORT MAIN ENGINE AND REPLACE OIL SOAKED LAGGING. VESSEL IS NOT TO GET BACK UNDERWAY OR TAKE PASSENGERS UNTIL REPAIRS ARE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Construction/Loadline
Issued 30 March 1995 Resolved
PROVIDE DOGGING DEVICES TO PORT ENGINEROOM ENTRY HATCH TO SECURE COMPARTMENT WEATHERTIGHT.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 28 November 1994 Resolved
Repair cracks in bottom aft steering void and top weld fractures on port side no later than 19DEC94. If this item is not corrected by 19DEC94 then you are required to surrender the vessel's COI until the repair has been made.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Construction/Loadline
Issued 14 July 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Construction/Loadline
Issued 18 September 1992 Resolved
MAKE PERMANENT REPAIRS IN WAY OF THE #2 STARBOARD PONTOON VOID TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO THE CARRIAGE OF PASSENGERS. TEMP. REPAIRS ARE SATISFACTORY ONLY FOR TRANSIT TO SEATTLE, WA. VESSEL IS NOT TO DEPART PORT OF SEATTLE, WA UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Documentation
Issued 30 May 1991 Resolved
PROVIDE A COPY TO THE [name withheld] OF THE SENIOR DECKHAND TRAINING PROGRAM AND LETTER OF DESIGNATION PRIOR TO DELETING THE MATE.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 26 April 1991 Resolved
PROVIDE GUARDS OVER ROTATING MACHINERY ON FORWARD END OF BOTH MAIN ENGINS._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1991
Resolved 26 April 1991
Construction/Loadline
Issued 22 August 1990 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD HULL IN WAY OF THE TEMPORARY REPAIR IN WAY OF THE AREA FORWARD OF THE RUDDER ON THE INBOARD SIDE OF CENTERLINE. AN AREA OF APPROXIMATELY 26" BY 30"
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD GENERATOR SAFETY DEVICES AND PROVE PROPER OPERATION. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 November 1989 Resolved
RENEW STRUCTURAL FIRE PROTECTION IN PORT ENGINE ROOM, PORT AND STARBOARD LAZERETTE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 20 April 1988 Resolved
PROVIDE INSPECTION ACCESS OPENINGS FOR PORT AND STARBOARD RUDDER STOCK VOIDS BY 27 APRIL 1989, AND IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Construction/Loadline
Issued 3 November 1987 Resolved
PROVIDE A SCHEDULE AND PROCESS TO MONITOR BLISTERING OF THE HULL.
Condition: Unknown
Due 3 November 1987
Resolved 3 November 1987
Construction/Loadline
Issued 3 November 1987 Resolved
PROVIDE SCHEMATICS AND OPERATING INFORMATION ON IMPULSE CARTHODIC PROTECTION.
Condition: Unknown
Due 3 November 1987
Resolved 3 November 1987
Engineering
Issued 26 May 1987 Resolved
1 REPLACE FUEL VENT FLAME SCREENS WITH 30X30 MESH SCREEN.
Condition: Unknown
Due 26 May 1987
Resolved 26 May 1987
Engineering
Issued 3 June 1986 Resolved
COMPLETE REPAIRS ON BOTH PORT AND STBD MAIN ENGINES AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 3 June 1986
Resolved 3 June 1986
Engineering
Issued 3 June 1986 Resolved
CONDUCT VESSEL UNDERWAY EXAM.
Condition: Unknown
Due 3 June 1986
Resolved 3 June 1986
Lifesaving
Issued 3 June 1986 Resolved
REMOUNT WATERLIGHT FOR RING BOUY PORT SIDE BRIDGE WING SO IT WILL HAVE UNOBSTRUCTED RELEASE PATH.
Condition: Unknown
Due 3 June 1986
Resolved 3 June 1986
Lifesaving
Issued 19 December 1985 Resolved
VESSEL MUST PROVIDE 4-18 MAN BOUYANT APPARATUS BY 20 JAN 86.
Condition: Unknown
Due 19 December 1985
Resolved 19 December 1985

Casualty record · 4

4 June 2004Routine · role: Involved in a Marine Casualty · activity 2091254
16 January 2008Routine · role: Acknowledged Pollution Source · activity 3131793
19 June 2013Routine · role: Involved in a Marine Casualty · activity 4630251
11 August 2013Routine · role: Involved in a Marine Casualty · activity 4682908
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.