Records from 2010 to 2026. Most recent: inspection, 6 May 2026.
Inspection history · 29
6 May 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8235594
29 September 2025
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8237668
15 May 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8087630
25 March 2025
Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8097740
13 August 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7970132
2 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889658
31 January 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845956
21 September 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7778682
15 March 2023
MTSA Verification · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7635236
21 October 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7576860
2 June 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7440922
6 December 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363508
15 October 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329256
16 June 2021
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7227553
14 June 2021
Administrative Inspection · Permit to Proceed
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7224679
14 June 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7285161
28 April 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7202233
24 March 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149073
19 March 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928500
15 May 2019
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6635979
10 December 2018
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6595421
1 November 2018
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 6573255
15 March 2018
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364701
9 November 2017
Administrative Inspection
Administrative · Navigation Center · Activity 6304044
3 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6117541
27 October 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6019994
27 July 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5955003
26 April 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5865130
12 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5828554
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 May 2026
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. MI observed the port and starboard emergency escape hatches in the engine room were not labeled. Properly label hatches within 14 days. 46 CFR 116.500(j)
46 CFR 122.606
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 19 May 2026
Resolution: Verified escape hatches were properly labeled in port and starboard engine room.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 May 2026
Resolved
On a vessel without overnight accommodations, the fire pump must be capable of delivering a single hose stream from the highest hydrant, through the hose and nozzle required by § 118.320 of this part, at a pitot tube pressure of 345 kPa (50 psi). MI observed the fire pump in the port side engine room maintained 35 psi when tested. Ensure pressure gauge delivers 50 psi within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 19 May 2026
Resolution: Vessel replaced port side fire pump in kind. Witnessed fire pump test with steady stream from fire nozzle. Pressure gauge maintained 78 psi.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2026
Resolved
Each hose must be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” (incorporated by reference, see § 114.600 of this chapter). MI observed several fire hoses were not UL 19 rated. Replace necessary hoses to meet UL 19 rating within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 19 May 2026
Resolution: Verified all fire hoses were replaced with UL 19 rated hoses.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 September 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port side, aft engine room ventilation closure frozen in the open position and the starboard aft engine room ventilation closure failed to self close when actuated.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 September 2025
Resolved 29 September 2025
Resolution: Corrected during the course of the inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 June 2022
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has started the required annual inspection prior to the 3 month date but has not completed all requirements of the annual inspection. Vessel is required to fully complete remainder of the annual inspection to the satisfaction of the attending Marine Inspector prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2022
Resolution: Vessel has successfully completed an annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 December 2021
Resolved
ADDRESS REMAINING WORKLIST ITEMS FROM PREVIOUS DRYDOCK.
Action required: 705 - Other - as specified
Resolved 10 February 2022
Resolution: Completed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 June 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space and may require the vessel to be drydocked or taken out of service to access the extent of damage and to enact repairs. The vessel reported striking a submerged object resulting in the loss of one t-foil and ingression of water at the inspection plate. Vessel is to haul out and conduct temp repairs until a new t-foil can be manufactured and assess the hull for other signs of damage prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 14 June 2021
Resolved 17 June 2021
Resolution: Temp repairs made. No water ingress found.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2021
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo an additional test or inspection deemed reasonable and necessary. The vessel is to undergo sea trials with an attending Marine Inspector upon installation of a new t-foil following striking an unknown submerged object.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2021
Resolved 1 June 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 March 2021
Resolved
Crop/renew pitted areas of hull bottom plate found:
1) Under shafts in stbd engine room
2) At fwd end of stbd engine room
3) Under sewage Tk on stbd side ~ 1-2' fwd of blkhd
4) Under sewage overboard valve (or thickness gauge)
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 10 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2021
Resolved
Crop/renew sewage tank vent pipe found holed.
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 10 February 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 March 2021
Resolved
Provide repair proposal for wastage identified on topside of port sponson.
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 10 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 March 2021
Resolved
Crop/renew hull damage on port sponson outboard side.
Action required: 705 - Other - as specified
Resolved 26 March 2021
Resolution: Repairs tested by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2019
Resolved
Replace electrical outlet covers in both port and stbd laz. Found two electrical receptacles with broken covers in port and stbd laz-four in total. Electrical equipment must be installed and maintained IAW 46CFR 120.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 20 May 2019
Resolution: Replaced electrical outlet covers in both port and stbd laz.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 15 May 2019
Resolved
Replace gaskets on laz hatches on both port and stbd side. Found both gaskets to be wasted. A hatch exposed to the weather must be watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 20 May 2019
Resolution: Replaced gaskets on laz hatches on both port and stbd side
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2019
Resolved
Provide lifering with required retroreflective material affixed. Found 01 lifering to be missing retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2019
Resolved 15 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019
Resolved
Provide suitable lagging on port MDE. Found missing lagging on port MDE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2019
Resolved 15 May 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Engineering › Bilge Water Management System › Piping
Issued 15 March 2018
Resolved
Repair port jet room bilge piping at pump outlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 March 2018
Resolved
Renew hatch gaskets on port and stbd jet rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Navigation › Piloting/Steering › Compass Deviation Table
Issued 3 May 2017
Resolved
Provide deviation table and light for compass.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 18 May 2017
Resolution: Deviation table and light provided for magnetic compass.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2017
Resolved
Provide large scale harbor charts for LA/LB and Avalon.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 9 May 2017
Resolution: Appropriate charts were made available onboard upon deficiency follow-up.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2017
Resolved
Replace expired medical supplies: Ammonia inhalants, Medicaine swabs, iodine wipes, analgesics.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 18 May 2017
Resolution: First aid kit supplies restocked.
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 3 May 2017
Resolved
Properly attach painter to weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 3 May 2017
Resolution: Painter attached to weak link instead of IBA cradle.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 3 May 2017
Resolved
Provide MIS report and proof of Employee enrollment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 3 May 2017
Resolution: MIS report and proof of employee enrollment provided.
Fire Fighting › Structural - A Class Divisions › External Escape Routes
Issued 3 May 2017
Resolved
Repair jammed dogs on port and starboard engine rooms emergency escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 3 May 2017
Resolution: New dogs installed on escape hatches.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2017
Resolved
Existing radiotelephony certificate too faded to read. Provide legible certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 3 May 2017
Resolution: Legible radiotelephony safety certificate provided.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2016
Resolved
Make permanent repairs to cracks identified in tonnage openings located on port and starboard t-foil compartments.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Construction/Loadline › Hull › Bracket
Issued 27 October 2016
Resolved
Replace in kind damaged gusset located inboard forward on port side sponson.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 October 2016
Resolved
Replace in kind sewage penetration piping identified in sewage compartment.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2016
Resolved
Replace in kind generator wet exhaust piping identified on port and starboard sides.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 27 October 2016
Resolved
Remove lagging and make available for inspection the condition and integrity of the expansion joint for exhaust for the # 2 MDE transom termination.
Due 11 November 2016
Resolved 2 November 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 27 October 2016
Resolved
Replace in kind valves identified for starboard fire pump, generator, A/C, and sewage flush system.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 12 April 2016
Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 3 May 2016