Records from 2001 to 2026. Most recent: inspection, 9 July 2026.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 24 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Regulatory (Subpart C or D), Gross Ton
735 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
9 July 2026
Examination of Repairs · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8397780
30 June 2025
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8170476
5 June 2024
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7927704
7 June 2021
Internal Structural Exam · COI Inspection · Drydock Exam · Examination of Repairs · Administrative Inspection · Cargo Tank Internal · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7218831
18 July 2018
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6483566
21 June 2017
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6182503
14 June 2016
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5907012
22 May 2015
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5141187
4 June 2014
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4884213
2 June 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4877068
12 August 2013
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4679856
4 May 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4300643
30 June 2011
COI Inspection · Cargo Tank Internal · MTSA Verification · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4053519
28 May 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3748907
26 May 2009
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3486035
7 May 2008
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3201026
21 October 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3099237
2 May 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2924228
1 December 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2832787
27 June 2006
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2692242
12 August 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2473149
13 July 2005
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2426668
20 July 2004
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2139349
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1996615
12 June 2003
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1815817
5 April 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1601130
17 September 2001
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1073570
13 August 2001
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1070427
29 June 2001
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1066990
21 June 2001
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1387105
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 September 2021
Resolved
Activates an alarm and automatic shutdown system on the vessel discharging cargo 60 seconds before the tank is 100 percent liquid-full during a vessel-to-vessel cargo transfer. Overfill and high level alarm system was unable to be activated and tested. Prove proper operation of overfill and high level alarm system to the satisfaction of the attending Marine Inspector.
46 CFR 39.2009(a)(2)(iii)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2021
Resolution: Vessel rep provided video evidence of proper operation of overfill and high level alarm system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2021
Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01-2) and may be installed only in vital and non-vital fresh and salt water systems, non-vital pneumatic systems, lube oil and fuel systems, and fluid power systems. Hose on prime mover was not in accordance with SAE J1942. Provide proof that hose is in accordance with SAE J1942.
46 CFR 56.60-25(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 17 September 2021
Resolution: Vessel rep changed hose to SAE J1942.
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 16 September 2021
Resolved
During cargo transfer operations inland oil barges must have appropriate equipment and supplies ready for immediate use to control and remove on-deck oil cargo spills of at least one barrel. Vessel's spill kit contents were not ready for immediate use. Provide appropriate spill kit contents that are ready for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 17 September 2021
Resolution: Replaced Tyvec suites to make spill kit ready for immediate use.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2021
Resolved
During an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. The number 2 cargo tank has extensive hogging amidships. Plans and specifications for repairs shall be submitted to the OCMI and Headquarters for approval. Crop and Renew as original is authorized temporarily and permanent repairs shall be conducted within 90 days once MSC has reviewed and notified of approved plans. Permanent repairs shall be conducted by October 14, 2021. Fit-up and repairs to be witnessed by USCG MI.
Action required: 705 - Other - as specified
Due 14 October 2021
Resolved 21 September 2021
Resolution: Received, reviewed and accepted repair proposal. Additionally, MSC has reviewed the same proposal and concurred with recommended repairs. MI verified all repairs completed.
Deck/Cargo
Issued 13 August 2001
Resolved
Relocate common header P/V valve so it is not less than 10' from cargo engine exhaust piping.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 21 June 2001
Resolved
Make permanent repairs to launch damage in #1 P&S wing void in the area of frame 5 and #4 port wing void in the area of frame 76 before vessel loads or carries any cargo. All repairs to be completed to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 15 July 2001
Resolved 29 June 2001