Records from 2011 to 2024. Most recent: inspection, 7 October 2024.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 12.0 ft × 6.4 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSANTA BARBARA BOATWORKS · GOLETA, CA, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
7 October 2024
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8016496
8 March 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7876280
4 October 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7803723
3 March 2023
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7651012
14 February 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7636929
24 August 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7602970
12 April 2021
COI Inspection · In-Service Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7185070
10 November 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7093406
8 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6830989
21 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6691691
9 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6473365
26 April 2018
COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6400269
28 June 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6182045
20 May 2016
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934301
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 March 2024
Resolved
As permitted by § 178.310(c) of this part, the following vessels may undergo the simplified stability proof test detailed in § 178.330 of this part, in the presence of a Coast Guard marine inspector, if they do not have tumblehome at the deck, measured amidships, that exceeds 2 percent of the beam. The aft transmission movement equates to an approximate 2.2% weight change. Vessel is required to undergo a new simplified stability test in the presence of a CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2024
Resolved 21 March 2025
Resolution: If vessel requests COI inpsection they will still need to undergo a new SST. Added special note in order to close def.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 March 2024
Resolved
As permitted by § 178.310(c) of this part, the following vessels may undergo the simplified stability proof test detailed in § 178.330 of this part, in the presence of a Coast Guard marine inspector, if they do not have tumblehome at the deck, measured amidships, that exceeds 2 percent of the beam. The aft transmission movement equates to an approximate 2.2% weight change. Vessel is required to undergo a new simplified stability test in the presence of a CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2024
Resolved 7 October 2024
Resolution: Deficiency closed, but remains condition to bring vessel back into service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 October 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction and a uniform load of 50 lbs per foot applied to the top rail in any direction. The forward bow railings are loose and have an insufficient level of strength. Vessel rep must submit plan for restoring strength to railings. Passengers are not authorized on the forward deck until structural strength is restored to the forward bow railings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 7 October 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2022
Resolved
All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection.
(1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel did not conduct an annual inspection before 26 July 2022. The vessel shall not operate till COI Renewal inspection has been completed by a USCG Marine Inspector.
Vessel has not been operating since June 2022 due to engine repowering. Vessel is currently waiting for parts to complete the repowering.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2023
Resolved 1 February 2023
Resolution: Completed annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2023
Resolved 1 February 2023
Resolution: AED battery and pads provided onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 August 2022
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel shall provide a propeller shaft size safety factor (SF) of approaching 10 per ABYC P6 with matching propeller size.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 8 March 2024
Resolution: Vessel rep has proven that the vessel does not meet ABYC safety factor of 10 and new shafts will need to be installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2019
Resolved
1 adult PFD exterior material was unacceptable due to faded exterior material. Renew PFD in accordance with 46 CFR 176.808(a)(2). Vessel limited to 23 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: PFD provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 May 2019
Resolved
Retro reflective tape was degraded on PFDs. Renew retro reflective tape in accordance with 46 CFR 176.808(a)(2) and 46 CFR 185.604(h).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 8 October 2019
Resolution: Retro reflective tape renewed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 May 2019
Resolved
Engine room high audible high water alarm was degraded. Repair or renew in accordance with 46 CFR 176.804(i).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 8 October 2019
Resolution: Engine room high water alarm repaired satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 May 2019
Resolved
Port deck rail was damaged during mooring activity. Stbd deck rail stanchion deck supports were loose. Repair deck rails in accordance with 46 CFR 177.900.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 8 October 2019
Resolution: Port deck railing repaired.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 May 2019
Resolved
Port ventilation cover for engine room was holed due to corrosion. Repair or renew in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2019
Resolved 8 October 2019
Resolution: New port ventilation cover provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 May 2019
Resolved
VHF DSC radio function was not programmed. Program in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 7 July 2021
Resolution: The VHF DSC Radio is operational and programmed correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2019
Resolved
Port and stbd fuel supply and return line bulkhead penetrations for flexible hoses were corroded and in need of renewal. Renew in accordance with 46 CFR 176.804(e) and 46 CFR 182.720.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 8 October 2019
Resolution: Penetrations renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2019
Resolved
Port and stbd fuel supply hose connections were corroded and in need of renewal. Renew in accordance with 46 CFR 176.804(e) and 46 CFR 182.720.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 8 October 2019
Resolution: Connections renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2019
Resolved
Port and stbd fuel return lines appeared to be unapproved hose. Prove compliance of existing hose or renew with approved hose in accordance with 46 CFR 176.804(e) and 46 CFR 182.720.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 8 October 2019
Resolution: Lines were changed to satisfactory copper tubing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 May 2019
Resolved
FCC Station License was expired. Provide current Station License in accordance with 46 CFR 184.502.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 7 July 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Fuel Oil Service System › Piping
Issued 26 April 2018
Resolved
13101-Inspection of all fuel systems. High pressure fuel lines are not clamped properly stbd eng.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 9 July 2018
Resolution: Clamps installed.