Records from 2001 to 2025. Most recent: inspection, 5 December 2025.
Inspection history · 25
5 December 2025
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8278346
24 February 2025
In-Service Inspection · Examination of Repairs
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8086608
4 December 2023
COI Inspection · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7855611
22 May 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7694484
18 November 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7597034
3 December 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7104672
17 September 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7060164
20 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6817079
24 October 2018
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6567754
20 September 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545950
7 December 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6320609
30 November 2016
Administrative Inspection · DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049652
3 December 2015
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5788225
9 December 2011
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4205252
6 December 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4374950
4 November 2010
Annual Inspection · Hull Examination · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3885268
16 December 2009
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3652183
29 September 2008
COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3335152
14 November 2007
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3098327
2 November 2005
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2527045
10 September 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2513278
4 November 2004
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2234922
26 November 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1955165
18 September 2003
Simplified Stability Test · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1907954
6 December 2001
Plan Review "T" Boat · Construction Oversight
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929169
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 December 2025
Resolved
Pre-engineered gas system not meeting the following requirement:
-Must override engine shutdown and start engines after discharge.
Must correct to satisfaction of USCG Marine Inspector prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 5 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 December 2025
Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Vessel had six (06) red flares at the time of the inspection. Must add six (06) more flares for vessel's route prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 5 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2025
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel operators must provide proof of annual maintenance for portable fire extinguishers to USCG or replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2025
Resolved 18 December 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2025
Resolved
All vessels that are permitted under their routes and conditions to allow crewmembers to enter the water during snorkeling excursions must adhere to the eligibility requirements under CG Sector Honolulu Work Instruction 31. The following were not available for inspection:
-Automated External Defibrillator (AED); Eligibility criteria #5
-Oxygen Bottle; Eligibility criteria #5
All crewmembers shall remain onboard vessel until above deficiencies have been rectified to the satisfaction of USCG.
Action required: 705 - Other - as specified
Resolved 15 January 2026
Resolution: Must adhere to full manning while anchored or at a mooring ball until requirements from Sector Hono WI 31 have been met.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
Vessel currently experiencing reduction in steering capabilities. Steering ram improperly connected and mounted. Vessel operator required to make necessary repairs to satisfaction of USCG Marine Inspector prior to getting underway with passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2020
Resolved
Starboard side navigation light not operational. Provided operational starboard navigation light. Restricted to daytime operations.
Action required: 705 - Other - as specified
Due 3 January 2021
Resolved 9 April 2021
Resolution: New light installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2020
Resolved
All around light/stern light blocked by Life Float. Raise light to ensure it can be seen as required.
Action required: 705 - Other - as specified
Due 3 January 2021
Resolved 9 April 2021
Resolution: New light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2020
Resolved
Retro-reflective tape on 02 child and 08 adult life jackets worn/wasted. Renew retro-reflective tape on life jackets. Passenger count reduced by 02 children and 08 adults.
Action required: 705 - Other - as specified
Due 3 January 2021
Resolved 9 April 2021
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 December 2020
Resolved
Life Float light housing cracked. Provide new Life Float light housing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2020
Resolution: New light provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2020
Resolved
During underway trial starboard engine giving off large amounts of black smoke. Troubleshoot issue in accordance with manufactures requirements and resolve issue.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2021
Resolved 9 April 2021
Resolution: Engine repair completed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 September 2018
Resolved
Lifefloat was unsatisfactory due to extreme fading.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2018
Resolution: Lifefloat renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2018
Resolved
3 adult PFDs failed inspection. Vessel limited to 18 total persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2018
Resolution: 3 adult PFDs provided.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 3 December 2015
Resolved
STBD propeller showed signs of cavitation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2015
Resolved 3 December 2015
Resolution: Vessel replaced propeller prior to getting underway.
Electrical › Electrical Distribution System (service) › Cable
Issued 3 December 2015
Resolved
Battery cables were lose.
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 4 December 2015
Resolution: Battery cables were tightened.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 November 2010
Resolved
Provide visible indicator for high water alarm in machinery space.
Action required: 705 - Other - as specified
Due 16 November 2010
Resolved 23 November 2010
Engineering › Bilge Water Management System › Pump
Issued 4 November 2010
Resolved
Provide visible indicator for operation of auto bilge pump in machinery space.
Action required: 705 - Other - as specified
Due 16 November 2010
Resolved 23 November 2010
Lifesaving › Lifefloat › Lifeline
Issued 29 September 2008
Resolved
Renew retaining line for life float light.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 16 October 2008
Construction/Loadline › Structures › Deck Plating
Issued 29 September 2008
Resolved
Repair as original cracks on deck in way off port diver access door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 16 October 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 September 2008
Resolved
Repair crack in port swimdeck support bracket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 October 2008
Resolved 16 October 2008
Electrical › Electrical Distribution System (service) › Switch
Issued 14 November 2007
Resolved
REPLACE BROKEN FLOAT SWITCH FOR BILGE HIGH WATER ALARM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 November 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 November 2007
Resolved
PROVE FLOAT LIGHT FRO LIFE RING MUST COMPLY WITH 46 CFR 161.010
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 November 2007
Lifesaving › Buoyant Apparatus › Float Free
Issued 14 November 2007
Resolved
PROVE LIFE FLOAT STOWAGE ARANGEMENT.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 November 2007
Fire Fighting › Fire Hydrants › Condition
Issued 14 November 2007
Resolved
PROVE FIXED FIRE FIGHTING BY PROVIDING A COPY OF SERVICE CERTIFICATE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 November 2007
Communications › Radio Communications › EPIRB
Issued 14 November 2007
Resolved
RENEW EPIRB HYDROSTATIC RELEASE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 November 2007
Documentation › Logs/Records › Drug Test Records
Issued 4 November 2004
Resolved
Provide drug audit MIS form.
Due 4 December 2004
Resolved 29 November 2004
Engineering › Fuel Oil Service System › Filter
Issued 4 November 2004
Resolved
Provide plugs for bottom of fuel oil racor filters.
Due 4 December 2004
Resolved 29 November 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 November 2004
Resolved
Provide retro- reflective tape for life ring.
Due 4 December 2004
Resolved 29 November 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 November 2004
Resolved
Provide evidence of annual servicing.
Due 4 December 2004
Resolved 29 November 2004
Lifesaving › Lifefloat › Float Free
Issued 4 November 2004
Resolved
Make life float arrangement in float free configuration.
Due 4 December 2004
Resolved 29 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2004
Resolved
Prove white all around running light.
Due 4 December 2004
Resolved 29 November 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 September 2003
Resolved
Fixed Fire System shutdown and override failed to function. Initial instalation was done incorrectly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003
Resolved 4 November 2004
Stability › Intact Righting Energy › General
Issued 18 September 2003
Resolved
Permanent ballast not yet installed. Vessel unable to pass stability without 400 pounds weight fwd.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003
Resolved 4 November 2004
Construction/Loadline › Structures › End Bulkhead
Issued 18 September 2003
Resolved
To meet cockpit vs. well deck requirements, the fwd edge of EC must cross vessel at/near gunwale height. Vent openings into ER and side compartments are open to flooding.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2003
Resolved 4 November 2004