Records from 2016 to 2025. Most recent: inspection, 21 October 2025.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 August 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. MI observed the vessel had not had an inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 24 September 2025
Resolution: Received pictures that master completed course
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 August 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements. Operator did not have operator license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 24 September 2025
Resolution: FCC paperwork complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025
Resolved
Where rigid nonmetallic material (plastic) is permitted for use in piping systems by this section, the following restrictions apply:(1) Penetrations of required watertight decks and bulkheads by any rigid plastic pipe are prohibited unless the following requirements are met:(i) Each penetration must be accomplished using an acceptable metallic through deck or through bulkhead fitting that is welded or otherwise attached to the bulkhead or deck by an accepted method; and(ii) One or more metallic shutoff valves must be installed adjacent to the fitting. Mi observed multiple plastic pipes penetrating the hull. Request vessel to submit a repair proposal on attaching a valve closest to the hull while in drydock.
Action required: 705 - Other - as specified
Resolved 21 November 2025
Resolution: Metal valves were installed at all through hulls
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024
Resolved
At each initial and subsequent inspection for certification, the owner shall be prepared to conduct tests and have vessel ready for inspection of its fire protection equipment. Portable fire extinguishers and fixed firefighting system have not received annual inspections required by 46CFR176.810. Ensure inspections and servicing is conducted prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Fire servicing has been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
Replace battery in ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 19 June 2024
Resolution: New batteries installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 May 2024
Resolved
FCC station license and FCC Safety Radio Telephony Certificate were not available for inspection. 47CFR80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 19 June 2024
Resolution: Provied valid FCC station license.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024
Resolved
Remove flammable liquids from engine room prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Crew removed all flammable liquids from the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024
Resolved
Electrical equipment must be installed and maintained to protect crew from electrical hazards and prevent fires. Rewire fresh water pumps to remove dead-end wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Dead-end wires have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024
Resolved
Each large battery must be located in a locker, room or enclosed box. Ensure cover is placed on battery box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Battery covers installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 May 2024
Resolved
Fire pump outlet must be fitted with a pressure gauge. Gauge on fire pump is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: New pressure gauge installed; test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024
Resolved
Replace outlet cover on exterior decks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: New outlet cover installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 May 2024
Resolved
Repair small hole in vessel hull IVO water tank space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Hole patched.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 June 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] repairs of a fractured deck stiffener in the aft-most compartment near the male passenger head sewage line, MI observed significant corrosion in the deck surrounding the sewage pipe, as well as on the stiffener where it meets this section of deck.
Submit repair proposal to crop and renew.
Repairs must be completed to the satisfaction of the CG prior to next credit drydock.
46 CFR 176.700(a)
Action required: 705 - Other - as specified
Due 6 June 2023
Resolved 17 November 2023
Resolution: Metal was descaled and painted to prevent further wastage. SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 May 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed the deck stiffener in the aft-most compartment near the passenger head sewage line was fractured in two locations.
Submit repair proposal.
46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Repaired fractures. Issued new CG-835 to crop and renew stiffener section during next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 May 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed an inset at the rub rail on the port quarter of the vessel.
Submit repair proposal.
46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Deck was cropped and renewed and inset was bent back into place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 November 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads.
The bilge manifold piping system was inoperable when tested by the crew. The crew members were unable to drain water from each compartment on the vessel when operating the bilge pump.
46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The bilge pump, manifold, and piping were operationally tested in the presence of the attending MI with no deficiencies noted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 November 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
The engine room is protected by a pre-engineered fire extinguishing system and the crew was unable to close the engine room supply ducts when operationally tested during the inspection due to a frozen/corroded hinge.
46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The engine room supply duct vent closures were operationally tested with no deficiencies noted.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 November 2022
Resolved
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station.
The public address system speaker on the main deck was removed from the vessel during a dry dock period and broadcasts on the public address could not be heard on the main deck under primary or emergency power. The public address announcement could not be heard from the operating station on the enclosed main deck using a bullhorn or by voice.
46 CFR 184.610(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The public address system has a backup Bluetooth public address speaker system that is audible on both passenger decks and has a battery supply of 18 hours.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2022
Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: the neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus; and the neutral bus shall be connected to ground. If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This ground connection must be at the switchboard or at the common ground plate, which must be accessible.
The neutral was not found connected to a neutral bus and directly connected to the ground bus with 3 grounding conductors attached. This is not a single connection to ground and provides a path for electricity to flow across the grounding conductors.
46 CFR 183.376(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 1 December 2022
Resolution: All neutrals were placed on the a neutral bus in the switchboard with a single connection to ground. All grounds were placed on a copper stud at the switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2022
Resolved
The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. Ground detection must be provided that: for an alternating current system, meets § 111.05-27 in subchapter J of this chapter.
The dual voltage generator was installed without ground fault detection at the switchboard.
46 CFR 183.324
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 1 December 2022
Resolution: The neutral bus is connected to one single ground to the hull and ground fault detection was placed around the ground conductor in the switchboard at the single connection to ground.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 November 2022
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck.
The max passenger occupancy for the 2nd passenger deck was not marked on either stairwell to transit to this deck.
46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 1 December 2022
Resolution: The max passenger occupancy for the 2nd passenger deck was found marked on each stairwell providing access to that deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 November 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit.” A first-aid kit must be easily visible and readily available to the crew.
The CG approved first aid kit onboard was found expired.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 1 December 2022
Resolution: The crew purchased a CG approved first aid kit and placed it onboard.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 February 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector.
Unable to conduct drills due to inclement weather.
46 CFR 176.808(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 12 March 2021
Resolution: Completed MOB and Abandon Ship drills with MI onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 February 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector.
Unable to conduct drill due to inclement weather.
46 CFR 176.810(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 12 March 2021
Resolution: Completed Fire drill with MI onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 February 2021
Resolved
A vessel on lakes, bays, and sounds, and rivers route must carry three hand red flares in accordance with 160.021 and three hand orange smoke distress signals approved in accordance with 160.037 or other standard specified by the Commandant.
All distress signals onboard were expired. Owner/operator replaced with 8 valid hand red flares distress signals.
46 CFR 180.68 (b)(1)-(2)
Action required: 10 - Deficiency Rectified
Resolved 16 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 February 2021
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] pump hoses on both engines found to be chafing against engine mounts.
46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 18 March 2021
Resolution: O/O sent photographs of replacement for water hose chafing gear.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2021
Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces.
Life jackets found in space beneath main deck. Owner/operator placed life jackets in readily accessible locations while MI onboard.
46 CFR 180.78(a)
Action required: 10 - Deficiency Rectified
Resolved 16 February 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 February 2021
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station licensee and installation certificates to be issued by the FCC.
MI found no crew member to hold valid Marine Radio Operator Permit.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 31 March 2021
Resolution: Received copy proof of master's Marine Radio Operator Permit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 November 2019
Resolved
The minium capcity of the fire pump must be 50GPM at a pressure of not less than 60PSI at the pump outlet. Pump did not meet above standard. prove proper operation of fire/bilge pump prior to operation with passengers. 46CFR181.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2019
Resolution: Operator replaced clutch.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2019
Resolved
All vessels must have navigation lights that are in compliance with the Navigation Rules. Prove operation of mast head and stern lights prior to operation from sunset to sunrise. 46CFR183.420
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 November 2017
Resolved
Show proof of updated COD (change of ownership and vessel name)
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 8 January 2018
Documentation › Certificates/Documents › FCC SSL
Issued 30 November 2017
Resolved
Show proof of undated Station License, with change to vessels name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Pollution › Removal Methods/Procedures
Issued 30 November 2017
Resolved
Remove 5 gallon (hydraulic oil) plastic containers, from port side void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2017
Resolved
Properly stow child size life-jackets, seperate from adult size life-jackets IAW 46 CFR 180.78.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 November 2017
Resolved
Properly label max passengers allowed on the upper deck IAW 46 CFR 185.604.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Documentation › Certificates/Documents › Stability Letter
Issued 30 November 2017
Resolved
Post Stability Letter at op station IAW 46 CFR 176.306
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifebuoys › Serviceable
Issued 30 November 2017
Resolved
Properly replace grablines on all (3) life-rings.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 30 November 2017
Resolved
Properly install type II retro-reflective tape, on all (3) life-rings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2017
Resolved
Demonstate satisfactory man-overboard drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 5 December 2017
Engineering › Bilge Water Management System › Pump
Issued 30 November 2017
Resolved
Demonstrate proper operaton of installed bilge pumping system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Vessel Activity › Other
Issued 29 September 2017
Resolved
Vsl must complete Drydock prior to carrage of passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2017
Resolved 30 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 18 September 2017
Resolved
Properly install guard on light fixture in E/R
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 September 2016
Resolved
Boom/boom cable attachment(thimble)located on house, centerline,forward bulkhead is in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 November 2017
Resolution: Replace/repair thimble.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2016
Resolved
Ring bouy, top deck, port side forward, has an incorrectly attached floating light. Light must be attahced to a lanyard, not less than three nor more than six feet securing the waterlight around the body of ring life buoy.
Condition: Improper Installation
Due 3 October 2016
Resolved 30 November 2017
Lifesaving › Lifebuoys › Immediately Available
Issued 1 September 2016
Resolved
Stern ring life buoy is not stowed in a way that allows it to be rapidly cast loose. Store in a bracket or similiar arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 November 2017