ALBEMARLE QUEEN

ALBEMARLE QUEEN is a 2001 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in October 2025, along with 45 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2025. Most recent: inspection, 21 October 2025.

Built
2001
Last inspected
21 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ5531
Flag
UNITED STATES
Maury page id
psix-25760

Documentation record

Registered dimensions (L × B × D)61.0 ft × 19.8 ft × 4.5 ft
Registered tonnagegross 52 / net 37
ITC dimensions (L × B × D)61.0 ft × 19.8 ft × 4.5 ft
ITC tonnagegross 52 / net 37
BuilderMID CITY STEEL FABRICATING INC · LA CROSSE, WI, UNITED STATES · built 2001
Hull materialSteel
PropulsionCombination Types
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEDENTON, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Convention (Subpart B), Gross Ton
37 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAI TIKI Passenger (Uninspected) · MISLE 1606130 · 5 May 2023 · activity 7689563

Inspection history · 20

21 October 2025 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8238887
27 August 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8208522
7 August 2025 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8204852
4 October 2024 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8014385
18 June 2024 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7942051
14 May 2024 Simplified Stability Test · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7916272
14 November 2023 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7822242
8 May 2023 Damage Survey · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7683864
5 May 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7689563
16 November 2022 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7590405
23 February 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7375518
23 November 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7331950
16 February 2021 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7126961
4 November 2019 Drydock Exam · Internal Structural Exam · Examination of Repairs · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6835543
5 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6617322
23 January 2018 In-Service Inspection · Simplified Stability Test · Administrative Inspection · Examination of Repairs · Deadweight Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6345455
13 November 2017 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6305526
29 September 2017 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6277694
18 September 2017 Deficiency Check · Hull Examination · Administrative Inspection · COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6304257
1 September 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5990629

Deficiency record · 45

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 August 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. MI observed the vessel had not had an inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 24 September 2025
Resolution: Received pictures that master completed course
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 August 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements. Operator did not have operator license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2025
Resolved 24 September 2025
Resolution: FCC paperwork complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025 Resolved
Where rigid nonmetallic material (plastic) is permitted for use in piping systems by this section, the following restrictions apply:(1) Penetrations of required watertight decks and bulkheads by any rigid plastic pipe are prohibited unless the following requirements are met:(i) Each penetration must be accomplished using an acceptable metallic through deck or through bulkhead fitting that is welded or otherwise attached to the bulkhead or deck by an accepted method; and(ii) One or more metallic shutoff valves must be installed adjacent to the fitting. Mi observed multiple plastic pipes penetrating the hull. Request vessel to submit a repair proposal on attaching a valve closest to the hull while in drydock.
Action required: 705 - Other - as specified
Resolved 21 November 2025
Resolution: Metal valves were installed at all through hulls
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
At each initial and subsequent inspection for certification, the owner shall be prepared to conduct tests and have vessel ready for inspection of its fire protection equipment. Portable fire extinguishers and fixed firefighting system have not received annual inspections required by 46CFR176.810. Ensure inspections and servicing is conducted prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Fire servicing has been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024 Resolved
Replace battery in ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 19 June 2024
Resolution: New batteries installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 May 2024 Resolved
FCC station license and FCC Safety Radio Telephony Certificate were not available for inspection. 47CFR80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 19 June 2024
Resolution: Provied valid FCC station license.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
Remove flammable liquids from engine room prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2024
Resolution: Crew removed all flammable liquids from the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Electrical equipment must be installed and maintained to protect crew from electrical hazards and prevent fires. Rewire fresh water pumps to remove dead-end wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Dead-end wires have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Each large battery must be located in a locker, room or enclosed box. Ensure cover is placed on battery box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Battery covers installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 May 2024 Resolved
Fire pump outlet must be fitted with a pressure gauge. Gauge on fire pump is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: New pressure gauge installed; test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Replace outlet cover on exterior decks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: New outlet cover installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 May 2024 Resolved
Repair small hole in vessel hull IVO water tank space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: Hole patched.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 June 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] repairs of a fractured deck stiffener in the aft-most compartment near the male passenger head sewage line, MI observed significant corrosion in the deck surrounding the sewage pipe, as well as on the stiffener where it meets this section of deck. Submit repair proposal to crop and renew. Repairs must be completed to the satisfaction of the CG prior to next credit drydock. 46 CFR 176.700(a)
Action required: 705 - Other - as specified
Due 6 June 2023
Resolved 17 November 2023
Resolution: Metal was descaled and painted to prevent further wastage. SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 May 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed the deck stiffener in the aft-most compartment near the passenger head sewage line was fractured in two locations. Submit repair proposal. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Repaired fractures. Issued new CG-835 to crop and renew stiffener section during next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 May 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed an inset at the rub rail on the port quarter of the vessel. Submit repair proposal. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 6 June 2023
Resolution: Deck was cropped and renewed and inset was bent back into place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 November 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. The bilge manifold piping system was inoperable when tested by the crew. The crew members were unable to drain water from each compartment on the vessel when operating the bilge pump. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The bilge pump, manifold, and piping were operationally tested in the presence of the attending MI with no deficiencies noted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 November 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The engine room is protected by a pre-engineered fire extinguishing system and the crew was unable to close the engine room supply ducts when operationally tested during the inspection due to a frozen/corroded hinge. 46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The engine room supply duct vent closures were operationally tested with no deficiencies noted.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 November 2022 Resolved
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. The public address system speaker on the main deck was removed from the vessel during a dry dock period and broadcasts on the public address could not be heard on the main deck under primary or emergency power. The public address announcement could not be heard from the operating station on the enclosed main deck using a bullhorn or by voice. 46 CFR 184.610(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2022
Resolved 1 December 2022
Resolution: The public address system has a backup Bluetooth public address speaker system that is audible on both passenger decks and has a battery supply of 18 hours.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2022 Resolved
A dual voltage generator installed on a vessel shall be of the grounded type, where: the neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus; and the neutral bus shall be connected to ground. If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This ground connection must be at the switchboard or at the common ground plate, which must be accessible. The neutral was not found connected to a neutral bus and directly connected to the ground bus with 3 grounding conductors attached. This is not a single connection to ground and provides a path for electricity to flow across the grounding conductors. 46 CFR 183.376(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 1 December 2022
Resolution: All neutrals were placed on the a neutral bus in the switchboard with a single connection to ground. All grounds were placed on a copper stud at the switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 November 2022 Resolved
The neutral of a dual voltage system must be accessible for checking the insulation resistance of the generator to ground before the generator is connected to the bus. Ground detection must be provided that: for an alternating current system, meets § 111.05-27 in subchapter J of this chapter. The dual voltage generator was installed without ground fault detection at the switchboard. 46 CFR 183.324
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 1 December 2022
Resolution: The neutral bus is connected to one single ground to the hull and ground fault detection was placed around the ground conductor in the switchboard at the single connection to ground.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 November 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. The max passenger occupancy for the 2nd passenger deck was not marked on either stairwell to transit to this deck. 46 CFR 185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 1 December 2022
Resolution: The max passenger occupancy for the 2nd passenger deck was found marked on each stairwell providing access to that deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 November 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit.” A first-aid kit must be easily visible and readily available to the crew. The CG approved first aid kit onboard was found expired. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 1 December 2022
Resolution: The crew purchased a CG approved first aid kit and placed it onboard.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 February 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Unable to conduct drills due to inclement weather. 46 CFR 176.808(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 12 March 2021
Resolution: Completed MOB and Abandon Ship drills with MI onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 February 2021 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Unable to conduct drill due to inclement weather. 46 CFR 176.810(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 12 March 2021
Resolution: Completed Fire drill with MI onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 February 2021 Resolved
A vessel on lakes, bays, and sounds, and rivers route must carry three hand red flares in accordance with 160.021 and three hand orange smoke distress signals approved in accordance with 160.037 or other standard specified by the Commandant. All distress signals onboard were expired. Owner/operator replaced with 8 valid hand red flares distress signals. 46 CFR 180.68 (b)(1)-(2)
Action required: 10 - Deficiency Rectified
Resolved 16 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 February 2021 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] pump hoses on both engines found to be chafing against engine mounts. 46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 18 March 2021
Resolution: O/O sent photographs of replacement for water hose chafing gear.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2021 Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets found in space beneath main deck. Owner/operator placed life jackets in readily accessible locations while MI onboard. 46 CFR 180.78(a)
Action required: 10 - Deficiency Rectified
Resolved 16 February 2021
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 February 2021 Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station licensee and installation certificates to be issued by the FCC. MI found no crew member to hold valid Marine Radio Operator Permit. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2021
Resolved 31 March 2021
Resolution: Received copy proof of master's Marine Radio Operator Permit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 November 2019 Resolved
The minium capcity of the fire pump must be 50GPM at a pressure of not less than 60PSI at the pump outlet. Pump did not meet above standard. prove proper operation of fire/bilge pump prior to operation with passengers. 46CFR181.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2019
Resolution: Operator replaced clutch.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 November 2019 Resolved
All vessels must have navigation lights that are in compliance with the Navigation Rules. Prove operation of mast head and stern lights prior to operation from sunset to sunrise. 46CFR183.420
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 November 2017 Resolved
Show proof of updated COD (change of ownership and vessel name)
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 8 January 2018
Documentation › Certificates/Documents › FCC SSL
Issued 30 November 2017 Resolved
Show proof of undated Station License, with change to vessels name.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Pollution › Removal Methods/Procedures
Issued 30 November 2017 Resolved
Remove 5 gallon (hydraulic oil) plastic containers, from port side void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2017 Resolved
Properly stow child size life-jackets, seperate from adult size life-jackets IAW 46 CFR 180.78.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 November 2017 Resolved
Properly label max passengers allowed on the upper deck IAW 46 CFR 185.604.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Documentation › Certificates/Documents › Stability Letter
Issued 30 November 2017 Resolved
Post Stability Letter at op station IAW 46 CFR 176.306
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifebuoys › Serviceable
Issued 30 November 2017 Resolved
Properly replace grablines on all (3) life-rings.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 30 November 2017 Resolved
Properly install type II retro-reflective tape, on all (3) life-rings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2017 Resolved
Demonstate satisfactory man-overboard drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 5 December 2017
Engineering › Bilge Water Management System › Pump
Issued 30 November 2017 Resolved
Demonstrate proper operaton of installed bilge pumping system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Vessel Activity › Other
Issued 29 September 2017 Resolved
Vsl must complete Drydock prior to carrage of passengers
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2017
Resolved 30 November 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 18 September 2017 Resolved
Properly install guard on light fixture in E/R
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 5 December 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 September 2016 Resolved
Boom/boom cable attachment(thimble)located on house, centerline,forward bulkhead is in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 November 2017
Resolution: Replace/repair thimble.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 September 2016 Resolved
Ring bouy, top deck, port side forward, has an incorrectly attached floating light. Light must be attahced to a lanyard, not less than three nor more than six feet securing the waterlight around the body of ring life buoy.
Condition: Improper Installation
Due 3 October 2016
Resolved 30 November 2017
Lifesaving › Lifebuoys › Immediately Available
Issued 1 September 2016 Resolved
Stern ring life buoy is not stowed in a way that allows it to be rapidly cast loose. Store in a bracket or similiar arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 November 2017

Casualty record · 1

5 May 2023Routine · role: Involved in a Marine Casualty · activity 7689563
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ANNA MARIA PRINCESS (2023). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.