PIRATE'S LADY

PIRATE'S LADY is a 1985 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1985, most recently in January 2007, along with 62 deficiencies — 4 with no resolution recorded —.

Records from 1985 to 2007. Most recent: inspection, 19 January 2007.

Built
1985
Last inspected
19 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAR2748
258171
Flag
UNITED STATES
—
Maury page id
psix-258171

Inspections, by type

…with no type recorded14
…past their stated due date4
Years with a record 22 calendar years (1985–2007)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAR2748MMSI not assigned · expired · voluntarily equipped · granted 26 February 1996, cancelled 29 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA EXPLORER Passenger (Inspected) · MISLE 51218 · 30 March 2005 · activity 2322776MORNING STAR Passenger (Inspected) · MISLE 54718 · 30 March 2005 · activity 2322776SEA EXPLORER Passenger (Inspected) · MISLE 51218 · 24 March 2005 · activity 2322348

Inspection history · 55

19 January 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858728
13 February 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2584149
30 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322776
28 March 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2321177
24 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322348
2 February 2005 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285162
22 December 2004 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2258076
14 December 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2258005
3 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2237888
24 June 2004 MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2109167
24 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2114149
4 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982178
11 December 2003 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1961913
8 December 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1960631
5 August 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1867604
12 April 2003 Type not recorded
No type recorded · USCGC FARALLON (WPB 1301) · USCG Southeast District (CGD-SE) · Activity 1784091
3 December 2002 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1713451
6 March 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1491595
19 December 2001 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476269
11 December 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473881
1 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16587
17 February 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1058672
21 December 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436313
14 December 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406626
15 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 152805
25 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11704
17 January 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811697
17 December 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442774
10 December 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1434808
30 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 793608
19 December 1997 Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113075
18 December 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093580
6 December 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187165
30 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 73977
19 December 1995 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874562
14 December 1995 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181116
13 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 59395
18 January 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 49233
20 December 1994 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 855110
2 June 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1148974
18 December 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134813
15 December 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831152
27 March 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955149
20 December 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941589
17 December 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253006
18 December 1990 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 901812
4 December 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 901490
14 December 1989 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1233403
12 December 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229722
12 January 1989 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195335
8 December 1988 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206069
11 December 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1014389
11 December 1987 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308673
17 December 1986 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027321
2 October 1985 COI Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991556

Deficiency record · 62

Engineering › Steering Gear System › Rudder
Issued 2 February 2005 No resolution recorded
Provide rudder stops IAW 46 CFR 182.610(c).
Condition: Placed in Improper Service
Due 14 December 2005 — due date passed with no resolution recorded
Documentation › Logs/Records › Enhanced Survey Report File
Issued 22 December 2004 Resolved
provide rigging report.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Documentation › Logs/Records › Logbook (official)
Issued 22 December 2004 Resolved
provide official log book, current light list and notice to mariners.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 December 2004 No resolution recorded
properly repair angle of port running light.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 December 2004 Resolved
replace grab line aft life ring.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 December 2004 Resolved
repair or replace fire extinguisher bracket #2 PAX stateroom.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Communications › Audible Communications › Horn/Whistle
Issued 22 December 2004 Resolved
properly repair horn.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 22 December 2004 Resolved
properly mount LPG cylinder.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 December 2004 Resolved
properly label bilge alarms and provide external speaker.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2004 Resolved
properly label 12 vlt panel in crew stateroom (E/R) and properly secure cover.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 22 December 2004 Resolved
provide buld and cover for light fixture in generator space.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 22 December 2004 No resolution recorded
make proper repairs to fuel oil return line on generator.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 22 December 2004 Resolved
locate and repair water leak and remove corrosion to fuel oil line in electrical space aft galley. plug petcocks on raycor filters.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 22 December 2004 Resolved
make proper repairs to timer cover in galley.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2004 Resolved
provide proper blank to power panel in galley.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 December 2004 Resolved
replace or repair 13 life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 25 March 2005
Engineering › Diesel Engine (auxiliary) › Governor
Issued 22 December 2004 No resolution recorded
replace dry rotted fuel oil hoses on breathing air compressor.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Bottom Plug
Issued 14 December 2004 Resolved
Repair/reseal galley sink through hole fitting.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2004 Resolved
Repair small areas of the bow that are showing signs of checking.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 14 December 2004 Resolved
Replace AC water supply valve.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2004 Resolved
Remove and treat wood fungus from generator space.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 14 December 2004 Resolved
Repair cracks to aft boarding ladder.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Documentation › Certificates/Documents
Issued 11 December 2003 Resolved
Provide valid FCC Safety Radio Certificate. LEGACY COMPONENT DESC: FCC Safety Radio Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2003
Resolved 12 December 2003
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 11 December 2003 Resolved
Install propane and cooking system in acordance with ABYC A-1-78. Until completed, galley is to be manned at all times when cooking system is in operation.
Due 11 January 2004
Resolved 22 December 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 11 December 2003 Resolved
Provide adequate ventilation for aft crew accommodation space.
Due 31 January 2004
Resolved 22 December 2004
Stability › Watertight Integrity › Weathertight Enclosure
Issued 11 December 2003 Resolved
Properly adjust forward hatch to line locker to ensure watertight integrity.
Due 11 January 2004
Resolved 22 December 2004
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 11 December 2003 Resolved
Ensure cooking appliance meets ANSI Z 21.57.
Due 11 January 2004
Resolved 22 December 2004
Stability › Watertight Integrity
Issued 3 December 2002 Resolved
Remove sluice valve IWO collision bulkhead.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2002
Resolved 6 December 2002
Resolution: Completed.
Electrical › Electrical Distribution System (service)
Issued 3 December 2002 Resolved
Provide proper connections for wiring IWO line locker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 6 January 2003
Resolution: Installed a junction box.
Stability › Watertight Integrity
Issued 3 December 2002 Resolved
Ensure that copper piping used for bonding strap penetrating the collision bulkhead does not allow passage of water.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 6 December 2002
Resolution: Renewed boarding strap. Plugged hole.
Electrical › Electric Generation Source (service)
Issued 3 December 2002 Resolved
Install battery covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 6 December 2002
Resolution: Installed terminal covers.
Engineering › Bilge Water Management System
Issued 3 December 2002 Resolved
Repair and demonstrate proper operation of bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2002
Resolved 13 December 2002
Resolution: Done.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 December 2002 Resolved
Install rail course in bow sprit to reduce opening from 24 inches to 12 inches. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2003
Resolved 13 December 2002
Resolution: Installed a course/rail to prevent passengers from accessing the sprit.
Engineering › Fuel Oil Service System
Issued 3 December 2002 Resolved
Renew fuel supply hose on main engine with approved hose - SAE J-1942. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2003
Resolved 13 December 2002
Resolution: Done.
Engineering › Fuel Oil Service System
Issued 3 December 2002 Resolved
Repair fuel leak in generator secondary fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2002
Resolved 13 December 2002
Resolution: Done.
Stability › Watertight Integrity
Issued 3 December 2002 Resolved
Install positive closing valves on all through hull fittings with exception of AC oveboard on stbd side aft near exhaust. All penetrations within 6IN of the deepest laod waterline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 13 December 2002
Resolution: Done.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 December 2001 Resolved
Proof of Maintenance or service documentation could not be provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2001
Documentation › Manifests/Lists
Issued 19 December 2001 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 19 December 2001
Documentation › Manifests/Lists
Issued 19 December 2001 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 19 December 2001
Lifesaving › Lifebuoys
Issued 19 December 2001 Resolved
Unknown Component - Improper/Lack of Maintenance (46CFR180.70)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 28 December 2001
Lifesaving › Lifejacket/PFD (Type III)
Issued 19 December 2001 Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 28 December 2001
Documentation
Issued 17 December 1998 Resolved
Prior to 17 Jan 99, organize your Chemical Testing Program IAW _x001C_ 46 CFR 4 & 16 and 33 CFR 95.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Construction/Loadline
Issued 17 December 1998 Resolved
Prior to 17 Jan 99, provide and post a bilge manifold diagram.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Fire Fighting
Issued 17 December 1998 Resolved
Prior to 17 Jan 99, label pull handles for each fixed fire extinguishing systems.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Lifesaving
Issued 17 December 1998 Resolved
Prior to 17 Jan 98, provide additional donning plackards through vessel.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Electrical
Issued 19 December 1995 Resolved
REPAIR/REPLACE STDB AFT BATTERY BOX.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 19 December 1995 Resolved
Install metallic cap on spare thru-hull fitting.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 19 December 1995 Resolved
REPAIR/REPLACE SETSCREWS FOR RAIL STAUCHIONS ON ALL LOOSE STANCHIONS BEFOREOPERATING WITH PASSENGERS.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 19 December 1995 Resolved
COMPLETE HULL REPAIRS (MARKED)
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Lifesaving
Issued 14 December 1995 Resolved
SERVICE LIFE RAFTS. TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 January 1996
Resolved 15 January 1996
Engineering
Issued 14 December 1995 Resolved
PROPERLY MARK FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 14 December 1995 Resolved
REPAIR BILGE SYSTEM TO PROVIDE PROPER SUCTION TO ALL SPACES SERVED BY THE SYSTEM PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 January 1996
Resolved 15 January 1996
Lifesaving
Issued 14 December 1995 Resolved
REPLACE HYDROSTATIC RELEASE AND REGISTURE EPIRB WITH NOAA
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Fire Fighting
Issued 14 December 1995 Resolved
ONE B-I FIRE EXTINGUISHER REQUIRES NEW HOSE.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Documentation
Issued 2 June 1993 Resolved
PROVIDE VALID RADIOTELEPHONEY CERTIFICATE. VESSEL IS RESTRICTED TO 1000 FEET FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Documentation
Issued 18 December 1992 Resolved
PROVE THE VESSELS CREW HAS BEEN PRE EMPLOYMENT DRUG TESTED AND ARE IN A RANDOM TESTING PROGRAM.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Engineering
Issued 18 December 1992 Resolved
REPLACE MAIN ENGINE FUEL HOSES WITH WIRE INSERTED, FIRE RETARDANT TYPE AS PER 46 CFR 182.20-40.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Electrical
Issued 20 December 1991 Resolved
INSTALL DUPLEX RECEPTICAL COVER FOR OVERHEAD OUTLET IN AFT CREW AREA.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Lifesaving
Issued 20 December 1991 Resolved
REPLACE ALL RING BUOYS.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991 Resolved
RELOCATE BATTERY CHARGER IN AFT CREW SPACE, ALSO INSTALL WITH A DRIP PROOF COVER.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991 Resolved
REMOVE LOCAL DISCONNECT SWITCH FOR AFT CREW AREA EMERGENCY LIGHT FIXTURE.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Deck/Cargo
Issued 11 December 1987 Resolved
INSTALL PROPER SIZE PIN IN ANCHOR SHACKLE.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987