Records from 1985 to 2007. Most recent: inspection, 19 January 2007.
Inspection history · 55
19 January 2007
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858728
13 February 2006
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2584149
30 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322776
28 March 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2321177
24 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322348
2 February 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285162
22 December 2004
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2258076
14 December 2004
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2258005
3 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2237888
24 June 2004
MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2109167
24 May 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2114149
4 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1982178
11 December 2003
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1961913
8 December 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1960631
5 August 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1867604
12 April 2003
Type not recorded
No type recorded · USCGC FARALLON (WPB 1301) · USCG Southeast District (CGD-SE) · Activity 1784091
3 December 2002
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1713451
6 March 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1491595
19 December 2001
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476269
11 December 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473881
1 May 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16587
17 February 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1058672
21 December 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436313
14 December 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406626
15 September 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 152805
25 April 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11704
17 January 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811697
17 December 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442774
10 December 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1434808
30 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 793608
19 December 1997
Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113075
18 December 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093580
6 December 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1187165
30 October 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 73977
19 December 1995
Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874562
14 December 1995
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181116
13 November 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 59395
18 January 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 49233
20 December 1994
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 855110
2 June 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1148974
18 December 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1134813
15 December 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831152
27 March 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955149
20 December 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941589
17 December 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253006
18 December 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 901812
4 December 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 901490
14 December 1989
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1233403
12 December 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229722
12 January 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195335
8 December 1988
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206069
11 December 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1014389
11 December 1987
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308673
17 December 1986
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027321
2 October 1985
COI Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991556
Engineering › Steering Gear System › Rudder
Issued 2 February 2005
No resolution recorded
Provide rudder stops IAW 46 CFR 182.610(c).
Condition: Placed in Improper Service
Due 14 December 2005 — due date passed with no resolution recorded
Documentation › Logs/Records › Enhanced Survey Report File
Issued 22 December 2004
Resolved
provide rigging report.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Documentation › Logs/Records › Logbook (official)
Issued 22 December 2004
Resolved
provide official log book, current light list and notice to mariners.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 December 2004
No resolution recorded
properly repair angle of port running light.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 December 2004
Resolved
replace grab line aft life ring.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 December 2004
Resolved
repair or replace fire extinguisher bracket #2 PAX stateroom.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Communications › Audible Communications › Horn/Whistle
Issued 22 December 2004
Resolved
properly repair horn.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 22 December 2004
Resolved
properly mount LPG cylinder.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 December 2004
Resolved
properly label bilge alarms and provide external speaker.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2004
Resolved
properly label 12 vlt panel in crew stateroom (E/R) and properly secure cover.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 22 December 2004
Resolved
provide buld and cover for light fixture in generator space.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 22 December 2004
No resolution recorded
make proper repairs to fuel oil return line on generator.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 22 December 2004
Resolved
locate and repair water leak and remove corrosion to fuel oil line in electrical space aft galley. plug petcocks on raycor filters.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 22 December 2004
Resolved
make proper repairs to timer cover in galley.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 December 2004
Resolved
provide proper blank to power panel in galley.
Condition: Placed in Improper Service
Due 27 January 2005
Resolved 25 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 December 2004
Resolved
replace or repair 13 life jacket lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 25 March 2005
Engineering › Diesel Engine (auxiliary) › Governor
Issued 22 December 2004
No resolution recorded
replace dry rotted fuel oil hoses on breathing air compressor.
Condition: Placed in Improper Service
Due 27 January 2005 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Bottom Plug
Issued 14 December 2004
Resolved
Repair/reseal galley sink through hole fitting.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2004
Resolved
Repair small areas of the bow that are showing signs of checking.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 14 December 2004
Resolved
Replace AC water supply valve.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2004
Resolved
Remove and treat wood fungus from generator space.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 14 December 2004
Resolved
Repair cracks to aft boarding ladder.
Condition: Improper/Lack of Maintenance
Due 16 December 2004
Resolved 14 December 2004
Documentation › Certificates/Documents
Issued 11 December 2003
Resolved
Provide valid FCC Safety Radio Certificate. LEGACY COMPONENT DESC: FCC Safety Radio Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2003
Resolved 12 December 2003
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 11 December 2003
Resolved
Install propane and cooking system in acordance with ABYC A-1-78. Until completed, galley is to be manned at all times when cooking system is in operation.
Due 11 January 2004
Resolved 22 December 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 11 December 2003
Resolved
Provide adequate ventilation for aft crew accommodation space.
Due 31 January 2004
Resolved 22 December 2004
Stability › Watertight Integrity › Weathertight Enclosure
Issued 11 December 2003
Resolved
Properly adjust forward hatch to line locker to ensure watertight integrity.
Due 11 January 2004
Resolved 22 December 2004
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 11 December 2003
Resolved
Ensure cooking appliance meets ANSI Z 21.57.
Due 11 January 2004
Resolved 22 December 2004
Stability › Watertight Integrity
Issued 3 December 2002
Resolved
Remove sluice valve IWO collision bulkhead.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2002
Resolved 6 December 2002
Resolution: Completed.
Electrical › Electrical Distribution System (service)
Issued 3 December 2002
Resolved
Provide proper connections for wiring IWO line locker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 6 January 2003
Resolution: Installed a junction box.
Stability › Watertight Integrity
Issued 3 December 2002
Resolved
Ensure that copper piping used for bonding strap penetrating the collision bulkhead does not allow passage of water.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 6 December 2002
Resolution: Renewed boarding strap. Plugged hole.
Electrical › Electric Generation Source (service)
Issued 3 December 2002
Resolved
Install battery covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 6 December 2002
Resolution: Installed terminal covers.
Engineering › Bilge Water Management System
Issued 3 December 2002
Resolved
Repair and demonstrate proper operation of bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2002
Resolved 13 December 2002
Resolution: Done.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 December 2002
Resolved
Install rail course in bow sprit to reduce opening from 24 inches to 12 inches. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2003
Resolved 13 December 2002
Resolution: Installed a course/rail to prevent passengers from accessing the sprit.
Engineering › Fuel Oil Service System
Issued 3 December 2002
Resolved
Renew fuel supply hose on main engine with approved hose - SAE J-1942. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2003
Resolved 13 December 2002
Resolution: Done.
Engineering › Fuel Oil Service System
Issued 3 December 2002
Resolved
Repair fuel leak in generator secondary fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2002
Resolved 13 December 2002
Resolution: Done.
Stability › Watertight Integrity
Issued 3 December 2002
Resolved
Install positive closing valves on all through hull fittings with exception of AC oveboard on stbd side aft near exhaust. All penetrations within 6IN of the deepest laod waterline.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 13 December 2002
Resolution: Done.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 19 December 2001
Resolved
Proof of Maintenance or service documentation could not be provided.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2001
Documentation › Manifests/Lists
Issued 19 December 2001
Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 19 December 2001
Documentation › Manifests/Lists
Issued 19 December 2001
Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 19 December 2001
Lifesaving › Lifebuoys
Issued 19 December 2001
Resolved
Unknown Component - Improper/Lack of Maintenance (46CFR180.70)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 28 December 2001
Lifesaving › Lifejacket/PFD (Type III)
Issued 19 December 2001
Resolved
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 December 2001
Resolved 28 December 2001
Documentation
Issued 17 December 1998
Resolved
Prior to 17 Jan 99, organize your Chemical Testing Program IAW _x001C_ 46 CFR 4 & 16 and 33 CFR 95.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Construction/Loadline
Issued 17 December 1998
Resolved
Prior to 17 Jan 99, provide and post a bilge manifold diagram.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Fire Fighting
Issued 17 December 1998
Resolved
Prior to 17 Jan 99, label pull handles for each fixed fire extinguishing systems.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Lifesaving
Issued 17 December 1998
Resolved
Prior to 17 Jan 98, provide additional donning plackards through vessel.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Electrical
Issued 19 December 1995
Resolved
REPAIR/REPLACE STDB AFT BATTERY BOX.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 19 December 1995
Resolved
Install metallic cap on spare thru-hull fitting.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 19 December 1995
Resolved
REPAIR/REPLACE SETSCREWS FOR RAIL STAUCHIONS ON ALL LOOSE STANCHIONS BEFOREOPERATING WITH PASSENGERS.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 19 December 1995
Resolved
COMPLETE HULL REPAIRS (MARKED)
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Lifesaving
Issued 14 December 1995
Resolved
SERVICE LIFE RAFTS. TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 January 1996
Resolved 15 January 1996
Engineering
Issued 14 December 1995
Resolved
PROPERLY MARK FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Construction/Loadline
Issued 14 December 1995
Resolved
REPAIR BILGE SYSTEM TO PROVIDE PROPER SUCTION TO ALL SPACES SERVED BY THE SYSTEM PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 January 1996
Resolved 15 January 1996
Lifesaving
Issued 14 December 1995
Resolved
REPLACE HYDROSTATIC RELEASE AND REGISTURE EPIRB WITH NOAA
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Fire Fighting
Issued 14 December 1995
Resolved
ONE B-I FIRE EXTINGUISHER REQUIRES NEW HOSE.
Condition: Unknown
Due 20 December 1995
Resolved 20 December 1995
Documentation
Issued 2 June 1993
Resolved
PROVIDE VALID RADIOTELEPHONEY CERTIFICATE. VESSEL IS RESTRICTED TO 1000 FEET FROM SHORE UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Documentation
Issued 18 December 1992
Resolved
PROVE THE VESSELS CREW HAS BEEN PRE EMPLOYMENT DRUG TESTED AND ARE IN A RANDOM TESTING PROGRAM.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Engineering
Issued 18 December 1992
Resolved
REPLACE MAIN ENGINE FUEL HOSES WITH WIRE INSERTED, FIRE RETARDANT TYPE AS PER 46 CFR 182.20-40.
Condition: Unknown
Due 18 December 1992
Resolved 18 December 1992
Electrical
Issued 20 December 1991
Resolved
INSTALL DUPLEX RECEPTICAL COVER FOR OVERHEAD OUTLET IN AFT CREW AREA.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Lifesaving
Issued 20 December 1991
Resolved
REPLACE ALL RING BUOYS.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991
Resolved
RELOCATE BATTERY CHARGER IN AFT CREW SPACE, ALSO INSTALL WITH A DRIP PROOF COVER.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Electrical
Issued 20 December 1991
Resolved
REMOVE LOCAL DISCONNECT SWITCH FOR AFT CREW AREA EMERGENCY LIGHT FIXTURE.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Deck/Cargo
Issued 11 December 1987
Resolved
INSTALL PROPER SIZE PIN IN ANCHOR SHACKLE.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987