Records from 1984 to 2007. Most recent: inspection, 19 January 2007.
Inspection history · 53
19 January 2007
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858739
13 February 2006
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2584150
8 September 2005
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486911
30 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322776
28 March 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2321045
2 February 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285156
24 August 2004
Type not recorded
No type recorded · USCGC SAWFISH (WPB 87357) · USCG Southeast District (CGD-SE) · Activity 2184331
19 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2138366
24 June 2004
MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2109163
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980216
16 December 2003
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1964836
5 August 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1867598
17 December 2002
COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1719656
10 December 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1716784
6 March 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1491609
19 December 2001
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1476284
4 December 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1435306
25 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1494451
28 April 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 52055
16 March 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1047024
16 December 1999
Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421764
1 October 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 124162
16 August 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 120244
21 December 1998
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 810408
21 December 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1409996
15 December 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473547
30 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1127345
23 December 1997
COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418275
27 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 208513
27 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 757152
20 December 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1094108
9 December 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093782
8 December 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882879
5 December 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883921
13 December 1994
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1140816
15 December 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1159979
8 December 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373956
16 December 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831010
4 December 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1142476
13 December 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1258300
10 December 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941474
20 February 1991
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 918894
10 December 1990
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 918016
4 December 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 900424
13 December 1989
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 924997
5 December 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 904323
12 January 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195330
23 December 1988
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206070
23 December 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1004774
2 December 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000244
12 December 1986
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023141
5 December 1985
Credit Drydock · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 990476
14 December 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 977172
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 28 March 2005
Resolved
Found Sewage overboard discharge valve in the open position while vessel was moored in Bayside Marina. Corrected on the spot.
Due 28 March 2005
Resolved 28 March 2005
Engineering › Steering Gear System › Rudder
Issued 2 February 2005
No resolution recorded
Provide rudder stops IAW 46 CFR 182.610 (c).
Condition: Placed in Improper Service
Due 10 December 2005 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Flange
Issued 16 December 2003
Resolved
Provide flame shield on RACOR filter for generator. LEGACY COMPONENT DESC: Filter
Due 15 January 2004
Resolved 25 March 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 16 December 2003
Resolved
Remove hose and make proper permanent repairs to suction line for electric fire pump at deck of machine space.
Due 15 January 2004
Resolved 25 March 2005
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 16 December 2003
Resolved
Ensure cooking appliance meets ANSI 2 21.57 and installation of entire cooking system is in accordance with ABYC A-1-78.
Due 23 January 2004
Resolved 25 March 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 16 December 2003
Resolved
Provide adequate ventilation for aft crew accomadation space.
Due 31 January 2004
Resolved 25 March 2005
Electrical › Electric Generation Source (service)
Issued 17 December 2002
Resolved
Provide generator with 50 deg celcius rating ambient temperature or demonstrate space does not go above 104 deg farienheit or derate generator to 80%, Provide plans prior to 17 Jan 03. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Due 17 January 2003
Resolved 23 December 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 17 December 2002
Resolved
Provide a vapor tight engine compartment from crew accomadation space IAW 182.35-1, by 17 Jan 03.
Condition: Improper Installation
Due 17 January 2003
Resolved 23 December 2003
Electrical › Electric Supply System (service)
Issued 17 December 2002
Resolved
Provide covers for all batteries. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 28 December 2002
Resolved 23 December 2002
Communications › Alarms/Indicators
Issued 17 December 2002
Resolved
Label all bilge alarms at helm. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Due 28 December 2002
Resolved 17 December 2002
Communications › Alarms/Indicators
Issued 17 December 2002
Resolved
Demonstrate operation of bilge alarm in lazarette. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Communications › Radio Communications
Issued 17 December 2002
Resolved
Provide proof of EPRIB registration. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 December 2002
Resolved
Provide proof of service report and demonstrate system will shut down engines and ventilation. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Engineering › Fuel Oil Service System
Issued 17 December 2002
Resolved
Demonstrate fuel shut off valves operate properly. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Personnel › Certificates/Documents/Licenses
Issued 17 December 2002
Resolved
Provide one master and one mate with STCW-95 endorsements. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Placed in Improper Service
Due 30 January 2003
Resolved 23 December 2003
Communications › Radio Communications
Issued 17 December 2002
Resolved
Provide proof of current FCC safety certificate. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Personnel › Certificates/Documents/Licenses
Issued 17 December 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2002
Resolved 23 December 2002
Construction/Loadline › Hull
Issued 10 December 2002
Resolved
Grind back areas of the hull indicated, to good material and leave exsposed for CG inspector.
Due 20 December 2002
Resolved 16 December 2002
Construction/Loadline › Structures
Issued 10 December 2002
Resolved
Provide rigging report. LEGACY COMPONENT DESC: Sail rigging
Due 20 December 2002
Resolved 16 December 2002
Construction/Loadline › Hull
Issued 10 December 2002
Resolved
Remove and reseal all rub rail thru hull mounting bolts to prevent further water intrusion. LEGACY COMPONENT DESC: Side Shell, rub rail
Condition: Improper/Lack of Maintenance
Due 10 January 2003
Resolved 16 December 2003
Construction/Loadline › Structures
Issued 10 December 2002
Resolved
Remove and reseal mounting bracket on fwd, port side stanchion. LEGACY COMPONENT DESC: Stanchion
Condition: Improper/Lack of Maintenance
Due 20 December 2002
Resolved 16 December 2002
Deck/Cargo › Mooring/Anchoring
Issued 10 December 2002
Resolved
Replace backing plate on anchor capstan. LEGACY COMPONENT DESC: Capstan
Condition: Placed in Improper Service
Due 20 December 2002
Resolved 16 December 2002
Construction/Loadline › Penetrations
Issued 10 December 2002
Resolved
Instal positive closing valves on all through hull penetrations within six inches of the deepest load waterline. LEGACY COMPONENT DESC: Spool Piece Valves
Condition: Placed in Improper Service
Due 20 December 2002
Resolved 16 December 2002
Engineering › Bilge Water Management System
Issued 10 December 2002
Resolved
Remove sluice valve from collision bulkhead seal penetration or pipe into fixed bilge system. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Due 20 December 2002
Resolved 16 December 2002
Stability › Watertight Integrity
Issued 10 December 2002
Resolved
Renew gaskets on number 2, 3 and 4 hatches. LEGACY COMPONENT DESC: Hatches
Condition: Improper/Lack of Maintenance
Due 20 December 2002
Resolved 16 December 2002
Construction/Loadline › Structures
Issued 10 December 2002
Resolved
Repair number 4 hatch to operate properly. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 20 December 2002
Resolved 16 December 2002
Construction/Loadline › Hull
Issued 4 December 2001
Resolved
Feather all areas marked on the hull before painting.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Hull
Issued 4 December 2001
Resolved
Grind and repair small area on the port side aft at the garboard near the keel.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Hull
Issued 4 December 2001
Resolved
Grind 4 areas marked on the bottom of the keel and let dry before repair. LEGACY COMPONENT DESC: Keel
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Hull
Issued 4 December 2001
Resolved
Repair small hole on the port side midship just below the waterline.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Penetrations
Issued 4 December 2001
Resolved
Remove and recaulk through hull fitting for the M/E suction line.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Hull
Issued 4 December 2001
Resolved
Grind and repair soft spot port side approx. 10' from the bow and 3' below the waterline.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 10 December 2001
Construction/Loadline › Structures
Issued 4 December 2001
Resolved
Repair the deck area in the lazarette around the tiller fitting and the rail stanchion on the starboard side. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 28 December 2001
Construction/Loadline › Structures
Issued 4 December 2001
Resolved
Determine cause of water intrusion around lazarette hatch and correct. LEGACY COMPONENT DESC: Manhole
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 19 December 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 4 December 2001
Resolved
Repair all loose stanchions. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 28 December 2001
Accommodation/Occupational Safety › Occupational Safety
Issued 4 December 2001
Resolved
Provide a rigger report when received.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2002
Resolved 28 December 2001
Lifesaving
Issued 16 December 1999
Resolved
SERVICE AND INSTALL LIFERAFTS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 16 December 1999
Resolved
REGISTER EPIRB WITH NOAA AND PROVIDE LABEL ON UNIT PRIOR TO THE CARRIAGE OFPASSENGERS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Fire Fighting
Issued 16 December 1999
Resolved
REMOUNT FIXED FIRE EXTINGUISHING BOTTLE IN GENERATOR SET SPACE PRIOR TO THECARRIAGE OF PASSENGERS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 16 December 1999
Resolved
AMEND EMERGENCY PROCEDURES TO REFLECT ACTUAL VESSEL/CREW ACTIONS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Documentation
Issued 16 December 1999
Resolved
PROVIDE CURRENT DRUG TESTING PROGRAM.
Condition: Unknown
Due 16 December 1999
Resolved 16 December 1999
Lifesaving
Issued 8 December 1995
Resolved
Provide additional PFD.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 8 December 1995
Resolved
Properly mark emergency excape hatches.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Documentation
Issued 8 December 1995
Resolved
Provide current nav rules, CFRs and charts.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Fire Fighting
Issued 8 December 1995
Resolved
Repair leak at fire pump guage.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Lifesaving
Issued 8 December 1995
Resolved
PROVIDE WATER LIGHT ON RING BOUYS.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Documentation
Issued 8 December 1995
Resolved
Provide proof of NOAA reistration for 406 EPIRB.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Electrical
Issued 13 December 1994
Resolved
PROVIDE PORTABLE EMERGENCY LIGHTING IN CREWS AND PASSENGER ACCOMMODATIONS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Lifesaving
Issued 13 December 1994
Resolved
REPLACE 4 CHILD PFDS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Accommodation/Occupational Safety
Issued 13 December 1994
Resolved
PROVIDE METAL COVERED TRASH CONTAINERS IN ACCOMMODATION AREAS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Electrical
Issued 13 December 1994
Resolved
REPAIR LIGHT IN CENTER CABIN STARBOARD SIDE.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Accommodation/Occupational Safety
Issued 13 December 1994
Resolved
SECURE LADDER TO CENTER CABINS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Unknown
Issued 13 December 1994
Resolved
PROVIDE EVIDENCE OF DRUG TEST PROGRAM.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Electrical
Issued 13 December 1994
Resolved
REPLACE COVER ON RACK LIGHT IN CREWS QUARTERS.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Construction/Loadline
Issued 8 December 1993
Resolved
ADJUST CLOSURE DEVICES ON WATERTIGHT HATCH BETWEEN STEERING GEAR COMPARTMENT AND GENERATOR SPACE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 21 December 1993
Construction/Loadline
Issued 8 December 1993
Resolved
RENEW GASKET FOR WATERTIGHT HATCH COVER OVER NUMBER 2 PASSENGER CABINS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1993
Resolved 21 December 1993
Documentation
Issued 4 December 1992
Resolved
COMPLETE WORK LIST ITEMS ISSUED DURING CREDIT DRYDOCK EXAM.
Condition: Unknown
Due 4 December 1992
Resolved 4 December 1992
Electrical
Issued 20 February 1991
Resolved
PROVIDE WIRING DIAGRAMS TO SHOW GENERATOR HAS FUSE PROTECTION TO DISTRIBUTION.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Electrical
Issued 20 February 1991
Resolved
MAKE REPAIRS NECESSARY FOR REINSPECTION FOR RE-ISSUE OF CERTIFICATE OF INSPECTION (CERTIFICATE IS WITHDRAWN UNTIL VESSEL IS PROVIDE WITH AND OPERATIONAL GENERATOR)._x001C_ _x001C_
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Navigation
Issued 2 December 1987
Resolved
INSTALL DOUBLE-NUT, COTTER PIN, OR OTHER SUITABLE DEVICE ON STEERING QUADRANT CONNECTING BOLT TO ENSURE NUT WILL NOT BACK OFF.
Condition: Unknown
Due 2 December 1987
Resolved 2 December 1987