MAURY USCG vessel records
← All vessels

BREAKWATER 551

Built
1967
Last inspected
6 March 2025
Controls
None recorded without a removal date
Also recorded as
WEEKS 551 (2023)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 6 March 2025
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 38 calendar years (1986–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBX3592
264202
Flag
UNITED STATES
Tonnage
966 - Regulatory (Subpart C or D), Gross Ton 966 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-264202
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 103

6 March 2025 COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8089143
24 January 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8069332
3 December 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8042694
1 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8012563
7 October 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7805134
8 May 2023 Annual Inspection · Plan Review (Other than "T")
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7683846
5 February 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7632316
5 February 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7632485
17 January 2023 Administrative Inspection · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7622399
31 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464488
6 January 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7376180
1 March 2021 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7147846
4 December 2019 Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6855330
12 June 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6709955
6 December 2018 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6592755
26 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6549089
5 January 2018 MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6333219
10 October 2017 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6285002
18 April 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127368
9 December 2016 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6073363
21 December 2015 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5786294
14 October 2014 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5004625
30 July 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4938555
15 October 2013 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4734716
1 October 2013 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4726512
25 June 2013 Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4632991
27 November 2012 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4491358
24 April 2012 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4296607
22 March 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4269368
24 February 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4250517
20 October 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4170579
22 September 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3858076
31 August 2010 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3839404
4 March 2010 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3689948
29 July 2009 Drydock Extension · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3549500
21 May 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3480661
23 June 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3241443
17 September 2007 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3059656
13 June 2007 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2960503
6 April 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2903170
5 April 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2902233
14 March 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2888311
9 March 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2884810
20 December 2006 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2863229
8 December 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2836908
9 November 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2817760
26 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2808642
14 September 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2777691
22 March 2006 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2608722
22 July 2005 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2435697
20 June 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2396652
29 April 2005 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2345430
31 August 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2183240
13 January 2004 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1982259
4 December 2003 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1959004
19 November 2003 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1948941
5 November 2002 Re-Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1690610
12 December 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1443112
20 November 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1448190
29 February 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 131362
29 October 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1045797
1 March 1999 Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1447916
8 February 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 793515
13 January 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 810477
11 January 1999 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1470754
15 December 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 807317
24 November 1998 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1368946
17 November 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1116204
20 May 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1098759
4 December 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1093478
3 December 1996 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1093484
17 January 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1409431
15 November 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 133892
27 October 1995 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 876179
15 July 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 877852
14 June 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419443
1 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1181429
30 August 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 869224
5 August 1994 Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1353627
2 August 1994 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1455179
18 May 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 162169
14 February 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1436847
19 November 1993 Permit to Proceed
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 849466
14 June 1993 COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156577
18 May 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833995
3 March 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1267807
23 April 1991 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1234749
15 April 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 902867
19 March 1991 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1231928
14 March 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 931216
7 March 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1232478
31 March 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348502
22 March 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194625
3 October 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1045033
23 June 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1032120
30 March 1988 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1039062
24 April 1987 Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332467
11 July 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293796
12 June 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305249
4 June 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997569
20 May 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997755
25 April 1986 Initial Certification · MARPOL Annex I Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1000704
30 January 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1299628

Deficiency record · 181

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2025 Resolved
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery, and equipment. Main deck house and machinery space overheads are leaking water into the control station and machinery space, respectively. Identify and repair leaks to satisfaction of MI. 46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: Machinery space and deck control station properly sealed to prevent water ingress
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 March 2025 Resolved
Tests and inspections of the lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection, and shall include, as applicable, a demonstration of: the proper condition of flotation equipment such as lifebuoys. Retroreflective material on lifebuoys is worn. Additionally, lifebuoy lights need to be attached around the body of the lifebuoy with a corrosion resistant clip. Repair/replace lifebuoys to satisfaction of MI. 46 CFR 199.45(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: Lifebuoy lights attached appropriately and retroreflective tape replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 March 2025 Resolved
Internal combustion engine exhausts shall be kept clear of and suitably insulated from combustible matter. Auxiliary generator exhaust manifold has no insulation to shield the hot surface from combustibles. Properly insulate to the satisfaction of the MI. 46 CFR 92.05-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: Exhaust manifold was found properly insulated after installation
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 March 2025 Resolved
Where natural ventilation is provided for spaces protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the ventilation. Paint locker (protected by CO2 extinguisher) vents do not have securing devices. Additionally, bulkhead of paint locker is holed and there is no bushing around CO2 hose. Plug holes and provide vent securing mechanisms to the satisfaction of MI. 46 CFR 95.15-35 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: Paint locker securing devices put in place and holes were plugged
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 6 March 2025 Resolved
General arrangement plans shall be kept up-to-date, any alteration being recorded in the applicable medium as soon as practicable. Posted Fire and Safety Plan does not correlate with onboard conditions: Doors are missing from survey room, Chief’s room, and HVAC room and smoke detector found missing from survey room. Replace doors and detector or update Fire and Safety Plan to satisfaction of MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 3 April 2025
Resolution: Received and reviewed updated Safety Plan
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 March 2025 Resolved
All relief valves for use on pressure vessels shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel. Two of the air receivers in the machinery space have relief valves that are set above the MAWP of the receivers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: New pressure relief valves installed and tested on air receivers (165 psi)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2025 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. A/C distribution panel (P18) had multiple openings and the electrical panels in the crane space were not able to latch close. Repair electrical panels to the satisfaction of the marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 31 March 2025
Resolution: Electrical panels in crane space properly secured
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 December 2024 Resolved
Certificate of Inspection will be issued for a period of five years. Vessel is currently drydocked in Virginia, not in service. Prior to it leaving drydock its COI will expire. Vessel is required to conduct COI renewal inspection prior to conducting normal working operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2024
Resolved 6 March 2025
Resolution: Conducted COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 May 2022 Resolved
03 Starboard- Crop and Renew bottom longitudinal bottom of the ladder
Action required: 705 - Other - as specified
Resolved 21 June 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 May 2022 Resolved
02 Port- Crop and Renew #3 frame at turn of bilge wastage to good metal.
Action required: 705 - Other - as specified
Resolved 21 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 January 2022 Resolved
Each pump must be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 p.s.i. Inspectors observed operation on both fire pump. Both only putting out 48 PSI. Vessel is required to show a sat operational test for both pumps for the attending Marine Inspector. 46 CFR 95.10-5(c) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 20 January 2022
Resolution: Recieved photos showing 52 psi
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 January 2022 Resolved
Each cable installation must meet - (1) Sections 25, except 25.11, of IEEE 45-2002 (incorporated by reference; see 46 CFR 110.10-1); or (2) Cables manufactured to IEC 60092-353 must be installed in accordance with IEC 60092-352 (both incorporated by reference; see 46 CFR 110.10-1), including clause 8. Inspector observed that the Aux Generator had welding lead for battery cable installed from batteries to starter. Require vessel to install approve battery cables to the attending Marine Inspector. 46 CFR 111.60-5(a) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 24 January 2022
Resolution: Received photos of the welding lead replaced by approved cable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 January 2022 Resolved
Each outlet and junction box must be suitable for the environment in which it is installed and be constructed to the appropriate NEMA or IEC standard. Inspector observed shore tie junction box had a opening on top that is exposed to the environment. Require vessel to make that opening watertight for the attending Marine Inspector. 46 CFR 111.81-1(f) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2022
Resolved 7 January 2022
Resolution: Received photo of the j box capped
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2021 Resolved
Monthly maintenance on lifesaving equipment was not completed for January and February 2021. Complete all required monthly maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2021
Resolution: Received monthly maintenance report.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2021 Resolved
Monthly inspections were not complete for the portable fire extinguishers.
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
Resolution: COnducted maintenance for March while present.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 1 March 2021 Resolved
The posted emergency and fire plan in the galley showed multiple inconsistencies with the vessel's current arrangement including inaccurate liferaft capacity/stowage and inaccurate stowage of immersion suits. Complete plan revision and submit for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2021
Resolution: Completed approval.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2021 Resolved
Compressed gas cylinders must always be stowed in a rack when not in use. Secure the 2 acetylene and 2 oxygen gas cylinders in rack.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2021
Resolution: Received proof of proper stowage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 March 2021 Resolved
The light located in the accommodation passageway was temporarily mounted. Permanently mount and prove proper repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2021
Resolution: Received picture clearing item.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 4 December 2019 Resolved
Found all immersion suits in unserviceable condition. Replace or provide certificate attesting to servicability from a certified facility.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2019
Resolution: All immersion suits were replaced with new ones, including lights and whistles.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 4 December 2019 Resolved
Immersion suit container must be marked in block letters. Found in unservicable condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2019
Resolution: New immersion suit container installed and marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 December 2019 Resolved
Vessels not on international voyage must meet the requirement of this subpart. Found liferings with expired batteries and dirty retro.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2019
Resolution: Ring lifebuoys serviced and waterlights had new batteries installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 December 2019 Resolved
Where natural ventilation is provided for spaces protected by CO2 system, shall be made from effectively closing. Found ventilation does not effectively close.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Ventilation closures for the paint locker had been serviced, and had securing mechanisms installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2019 Resolved
Fire pumps must be fitted with a pressure gage on discharge side of pump. Pressure gage inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 December 2019
Resolution: Fire pump dishcarge had a functioning pressure gauge installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 December 2019 Resolved
Found navigation lights extinguished on starboard side and mast. Vessel is restricted to day time operations until all navigation lights are operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 5 December 2019
Resolution: Navigation lights were tested and found to be functional.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2019 Resolved
Remove dead end wiring in locker room or terminate at junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 5 December 2019
Resolution: Dead end wiring in locker room had been removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2019 Resolved
Properly secure and support wire run in aft crane house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 5 December 2019
Resolution: Unsupported wiring in aft carane house was properly supported.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018 Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting invalid IMO # and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 January 2022
Resolution: Received photo of vessel updated info to AIS and also look up vessel AIS info for error on the AIS website.
Construction/Loadline › Structures › Manhole
Issued 21 December 2015 Resolved
Make #3P void watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 11 January 2016
Resolution: New Hatch Gasket was installed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 14 October 2014 Resolved
Hydrostatically test 2 air receivers to 1.25 MAWP
Action required: 705 - Other - as specified
Due 13 November 2014
Resolved 29 October 2014
Resolution: Hydrostatically tested 4 air receivers to 1.25 MAWP. All sat
Electrical › Lighting (service) › Ground Indicator
Issued 1 October 2013 Resolved
Vessel 480v generator switchboard ground detection panel indicated a "c" phase ground. Provide an electrical report stating the cause and corrective action taken to correct the deficiency. 46 CFR 111.35-5(J) "Old J" - Changed deficiency due date from 07OCT to 01NOV per vessel request for more time to address due to current operations.
Due 1 November 2013
Resolved 15 October 2013
Resolution: Received a statement from vessel electrician stating that the ground detection light on "C" phase was not a true ground problem. It turned out to be a fuse that was not properly seated in a fuse holder for phase "C" .
Electrical › Lighting (service) › Lighting Fixture
Issued 1 October 2013 Resolved
)Lighting fixtures shall be properly supported and mounted. Twist on connectors must be made within an enclosure and secured to prevent loosening due to vibration.
Due 7 October 2013
Resolved 15 October 2013
Resolution: Received a picture from vessel electrician showing emergency lighting properly supported and mounted.
Stability › Watertight Integrity › General
Issued 1 October 2013 Resolved
Machinery spaces are required to be watertight. Provide pictures showing the corrective actions taken to maintain watertight integrity around the deck house.
Due 15 October 2013
Resolved 15 October 2013
Resolution: Received a statement and picture from Vessel rep [name withheld] showing a welded fitting on the engine room hatch coming of a schedule 80 elbow pipe fitting with a cap.
Lifesaving › Immersion Suits › General
Issued 1 October 2013 Resolved
Immersion suits must have a life jacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit. Provide picture showing 10 immersion suits with approved lights. 46 CFR 199.70 (c)(4)(i)
Due 7 October 2013
Resolved 15 October 2013
Resolution: Received a picture from vessel rep [name withheld] of 10 approved lights.
Engineering › Pressure Vessel › Relief Valve
Issued 1 October 2013 Resolved
Pressure vessel relief valve inside the crane house shall not be reset for any pressure more than 10% below or 10% above that for which the relief valve is marked. Install and provide pictures of new relief valve of the same settings. 46 CFR 54.15-10(g)
Due 15 October 2013
Resolved 15 October 2013
Resolution: Received picture from vessel rep [name withheld] of a newly installed pressure relief valve. Vessel rep provided a statement that relief valve has a 180 psi setting and relieves and closes below the design pressure of the air receiver 207 psi.
Communications › Alarms/Indicators › General Alarm
Issued 27 November 2012 Resolved
Prove proper operation of all general alarm contact makers and bells. Vessel restricted from working/operating until cleared.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2012
Resolved 21 December 2012
Lifesaving › Inflatable Liferafts › Capacity
Issued 27 November 2012 Resolved
Vessel restricted to carrying no more than 10 industrial workers due to life raft capacity of 10. Until reflected on COI
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 2 January 2013
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 27 November 2012 Resolved
Prove proper operation of main engine/generator and applicable safety shutdowns. During inspection, engine was not operational.
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 2 January 2013
Stability › Watertight Integrity › General
Issued 27 November 2012 Resolved
Find and make proper repairs to water leaks in aft bulkhead of engine room and crane room window.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 November 2012 Resolved
Provide cover for electrical box above resistors in stern spud room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Lighting (emergency) › Conductor
Issued 27 November 2012 Resolved
Prove proper operation of all emergency lighting and test on emergency circuit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 27 November 2012 Resolved
Make proper repairs to telephone box wiring connections in engine room and stern spud room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 November 2012 Resolved
Provide proper stowage for batteries in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 November 2012 Resolved
Provide rubber matting in front and rear of all switchboards on ship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 27 November 2012 Resolved
Properly mount capacitor and electrical connections in engine room on hot water circulating pump on the starboard side pumping in the overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 November 2012 Resolved
Properly stow all loose gear in way of engine room main panel board and welder's shack; to include light bulbs, batteries, and boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 27 November 2012 Resolved
Provide bottom plug/cap for shore connection box on deck in aft passageway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 November 2012 Resolved
Provide locking mechanism for all electrical panel doors in the air handler room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 November 2012 Resolved
Properly tie in air handler fan to ship's electrical system and remove outlet plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 27 November 2012 Resolved
Prove proper operation of sink in head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2012 Resolved
Prove proper operation and installation of all lighting in accommodation spaces to include working bulbs, proper covers, and proper wire connections in junction boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 27 November 2012 Resolved
Provide proper safety relief valves for Air Recievers which are 165 psi MAWP tanks with 180 psi safety reliefs, they need to be 165psi valves.
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 November 2012 Resolved
Provide dead front type panels for circuit break in crane room or replace.
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Personnel › Certificates/Documents/Licenses › MMD, Lifeboatman
Issued 27 November 2012 Resolved
Provide certification for lifeboatman or Ab cert for crew that gets underway
Action required: 705 - Other - as specified
Due 27 December 2012
Resolved 21 December 2012
Construction/Loadline › Hull › Bottom Plating
Issued 24 April 2012 Resolved
Provide gauging and original scantling measurement for inset in Port Bow Void Tank near turn of the bilge.
Action required: 705 - Other - as specified
Resolved 9 July 2012
Resolution: Rcvd gauging report. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2012 Resolved
Renew as original cracked weld on upper stern log plating in Aft Port Ballast Tank in the 7th bay inboard from port side shell.
Action required: 705 - Other - as specified
Resolved 9 July 2012
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2012 Resolved
Aft starboard ballast tank (in way of aft starboard corner of vessel) gouge and weld, crop and renew, or correct as neccesary all items as marked by blue chalk. (Tank had many stuctural members broken, check to mnake sure all are fixed)
Action required: 705 - Other - as specified
Resolved 9 July 2012
Resolution: Witnessed final air testing of compartment. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2012 Resolved
Aft starboard void tank, in way of entrance hatch, re-attach craked weld. Area marked with blue chalk.
Action required: 705 - Other - as specified
Resolved 9 July 2012
Construction/Loadline › Hull › Transverse Frame
Issued 24 April 2012 Resolved
Aft starboard void tank, bay 2, the top half of the aft web framing/swash bulkhead, crop and renew. Area marked with blue chalk.
Action required: 705 - Other - as specified
Resolved 27 February 2017
Resolution: Witnessed replaced framing. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2012 Resolved
Starboard spud cofferdam, gouge and weld cracked weld in way of aft interior corner of cofferdam. Area marked with blue chalk.
Action required: 705 - Other - as specified
Resolved 9 July 2012
Resolution: Witnessed final air testing of cofferdam. All sat.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 20 October 2011 Resolved
Containment area around fill pipe and vent pipes was holed and wasted. Repair/replace containment.
Due 20 November 2011
Resolved 2 December 2011
Resolution: Recieved pictures from vsl rep attesting to the repairs made to the containment area.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 October 2011 Resolved
Prove proper operation of E lighting in the auxilary machinery space.
Due 3 November 2011
Resolved 2 December 2011
Resolution: Recieved confirmation from vsl rep that non-functioning e-lighting had been replaced.
Personnel › Certificates/Documents/Licenses › MMD, Lifeboatman
Issued 31 August 2010 Resolved
Provide proof of certified lifeboatman IAW 46 CFR 199.100(c) prior to working lakes, bays, and sounds w/in 30 days.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 22 September 2010
Resolution: Provided documents for both day and night shift
Documentation › Logs/Records › Oil Record Book
Issued 31 August 2010 Resolved
Provide oil record book IAW 33 CFR 151.25 w/in 30 days.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 22 September 2010
Resolution: Provided Oil Record Book
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 31 August 2010 Resolved
Provide proof of proper operation of lube oil shutdown IAW 46 CFR 111.12-1 Aux Generator
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 22 September 2010
Resolution: Conducted test of safety mechanism for Aux Generator.
Construction/Loadline › Hull › Side Shell
Issued 29 July 2009 Resolved
Repair 2" fracture (side shell) IWO port spud well cofferdam IAW best practices, to the satisfaction of the attending marine inspector. The vertical fracture is located appx 24" up from the bottom plate and runs parallel to the FWD spud well box structure along the side shell.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2009
Resolved 23 November 2009
Resolution: Repaired 2" fracture (side shell) IWO port spud well cofferdam. Port spud well underwent boundary air test at 1.5 psi and additional cracks were found and repaired.
Construction/Loadline › Hull › Hull Plating
Issued 29 July 2009 Resolved
Crop and renew fractured section of deck plating IWO the STBD FWD bow void. The 16" - 18" transverse fracture is located just FWD of the STBD fairlead roller (head wire). An added strength plate with additional framing substructure may prevent recurrences.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2009
Resolved 24 November 2009
Resolution: Cropped and renewed fractured section of deck plating. Marine inspector witnessed satisfactory boundary air test at 1.5 psi at Colonnas Chipyard, Norfolk, VA.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 29 July 2009 Resolved
Clean out, flush and hydrostatically test the port FWD engine room and crane air receivers due to rust scale build-up and indicated localized pitting IWO the exterior portions of the air receivers. Test to 1.5 times the MAWP.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 30 November 2009
Resolution: Hydrostatically tested the port forward engine room air receiver to 1.5 times the MAWP.
Engineering › Compressed Air System (start air) › Piping
Issued 29 July 2009 Resolved
Install proper sized compressed air piping IWO main generator air starter and repair air starter.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 4 December 2009
Resolution: Inspected system and conducted two air starts satisfactorily.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 July 2009 Resolved
Install exhaust lagging IWO main generator exhaust (completely missing).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 30 November 2009
Resolution: Installed exhaust lagging IWO main generator exhaust.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 29 July 2009 Resolved
Renew vent screens IWO STBD fuel tank and port lube oil tank vents. Provide 30X30 screen.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 20 November 2009
Resolution: Renewed vent screens.
Engineering › Generator (propulsion/auxiliary-electric) › Busway
Issued 29 July 2009 Resolved
Secure back panels IWO crane SWBD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 20 November 2009
Resolution: Secured back panels IWO crane swash bulkhead.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 July 2009 Resolved
Crop and renew wasted section of mast and repair masthead lights (restricted lights not operating).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 4 December 2009
Resolution: Visually inspected masthead lights, all satisfactory.
Fire Fighting › Nozzles › Approval
Issued 29 July 2009 Resolved
Provide two approved fire nozzles. Nozzles are currently plastic.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2009
Resolved 30 November 2009
Resolution: Provided two approved fire nozzles to the attending marine inspector.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 May 2009 Resolved
Vessel needs to update the contact information in the SOPEP.
Action required: 705 - Other - as specified
Due 26 May 2009
Resolved 22 May 2009
Lifesaving › Immersion Suits › Retroreflective Material
Issued 21 May 2009 Resolved
Properly replace retro tape on immersion suits.
Action required: 705 - Other - as specified
Due 26 May 2009
Resolved 22 May 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 May 2009 Resolved
Properly place a clip on the line from the lifebouy to the light
Action required: 705 - Other - as specified
Due 26 May 2009
Resolved 22 May 2009
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 23 June 2008 Resolved
Clear all worklist items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2008
Resolution: Cleared all items. SAT
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 5 April 2007 Resolved
Prove proper operation of generator over speed trip and L/O shut down.
Action required: 705 - Other - as specified
Due 6 May 2007
Resolved 9 April 2007
Resolution: Generator over speed and L/O shut down tested satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 April 2007 Resolved
Repairs fuel leaks at main isolation valve and sight glasses on day tank in engineroom.
Action required: 705 - Other - as specified
Due 6 May 2007
Resolved 9 April 2007
Resolution: Fuel leaks repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 April 2007 Resolved
Provide B-IV fire extinguisher for engineroom iaw 46 cfr 95.50-10(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 13 June 2007
Resolution: B-IV extinguisher provided for engine room.
Engineering › Steam Boiler (auxiliary/waste heat) › Shell
Issued 5 April 2007 Resolved
Conduct hydrostatic test on boiler.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 13 June 2007
Resolution: Satisfactory hydrostatic test conducted on boiler.
Stability › Watertight Integrity › Coaming
Issued 8 December 2006 Resolved
Repair or replace mess deck escape hatch. Prior to operating beyond the boundry line.
Due 22 December 2006
Resolved 20 December 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2006 Resolved
Make proper repairs to stbd electrical swing motor cooling fan.
Due 22 December 2006
Resolved 20 December 2006
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 December 2006 Resolved
Prove proper operation of overspeed device on auxilliary generator. Prior to operation of generator.
Action required: 705 - Other - as specified
Due 22 December 2006
Resolved 20 December 2006
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 14 September 2006 Resolved
Replace pressure gauge for Crane Air Receiver.
Condition: Improper/Lack of Maintenance
Due 14 October 2006
Resolved 26 September 2006
Resolution: Cleared
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 September 2006 Resolved
Replace pressure gauges for both Control Air Receivers.
Condition: Improper/Lack of Maintenance
Due 14 October 2006
Resolved 26 September 2006
Resolution: Cleared
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 September 2006 Resolved
Replace GFI receptacle throughout vessel accommodation spaces.
Condition: Unknown
Due 14 October 2006
Resolved 26 September 2006
Resolution: Cleared
Construction/Loadline › Penetrations › Gasket
Issued 14 September 2006 Resolved
Repair/Replace gaskets on watertight doors and hatches throughout vessel. Galley, Engine Room, Tool Room Doors, and Escape Hatch IWO lower accommodation area need replacement or repair.
Condition: Improper/Lack of Maintenance
Due 10 November 2006
Resolved 8 December 2006
Resolution: WTD''s replaced, escape hatch administratively cleared, and re-issued as a seperate item.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2006 Resolved
Replace/Repair electrical cable tray in way of Crane Motor Room, Starboard side, overhead, where wasted. Properly route all cable in this area. If wire runs are not supported in cable trays, non-combustible strapping or wrap must be used. (Wiring in overhead near electrical switchboard in Crane Motor Room also needs to be properly hung.)
Condition: Improper/Lack of Maintenance
Due 10 November 2006
Resolved 8 December 2006
Resolution: Tray re-welded in place, cables routed sat.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 14 September 2006 Resolved
Replace containment plugs in all vessel containment coamings where missing.
Condition: Unknown
Due 14 October 2006
Resolved 26 September 2006
Resolution: Cleared
Engineering › Non-conventional Propulsion/Steering › Housing (cycloidal)
Issued 14 September 2006 Resolved
Remove temporary air blower used for cooling air IWO starboard electrical swing motor housing. Replace and properly wire in kind replacement motor as originally installed.
Condition: Unknown
Due 10 November 2006
Resolved 8 December 2006
Resolution: This item was not corrected. It was not on the Port Engineers copy of the CG-835. Item administratively cleared and re-issued as a new item.
Electrical › Electric Supply System (service) › Cable
Issued 13 September 2006 Resolved
Repair electrical connections and cable in way of both supply side, and panel to load, on vessel's Air Conditioning system, Main Deck.
Condition: Improper/Lack of Maintenance
Due 14 October 2006
Resolved 17 October 2006
Resolution: Cleared
Engineering › Fuel Oil Service System › Vent Pipe
Issued 13 September 2006 Resolved
Repair closure mechanism on fuel tank vent, port side.
Condition: Improper/Lack of Maintenance
Due 14 October 2006
Resolved 26 September 2006
Resolution: Cleared
Construction/Loadline › Penetrations › Flange Pad
Issued 29 April 2005 Resolved
On deck, wiring stuffing tubes IWO Hydralic and Waste Oil Tank vents on Stbd side are damaged. Renew to original water tight condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Resolution: New stuffing tubes installed.
Engineering › Lubricating Oil Service System › Gauge
Issued 29 April 2005 Resolved
Both the cooling water and lube oil temp gages as well as the engine tachometer are not functioning on the 125KW gen set. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Resolution: Gages replaced in kind.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 April 2005 Resolved
No documentation available indicating that the MSD is a certified type. Provide USCG certification documentation.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 1 June 2005
Resolution: Proper documentation was provided proving USCG certification of the installed MSD.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 April 2005 Resolved
Sewage holding tank discharge pump controler IWO Marine Sanitation Device (MSD) has follen away from mount and is hanging from cable. Properly re-install or remove if not needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 1 July 2005
Resolution: Varified proper installation of controller.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 April 2005 Resolved
Wire run behind main switch board has multiple dead end wires. Properly terminate or remove all dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 21 June 2005
Resolution: All dead end wires were properly terminated in a receptacle.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 29 April 2005 Resolved
Ships heater/boiler not functioning due to broken burner unit under repair. Prove proper operation of ass safety systems to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 21 June 2005
Resolution: New burner unit installed. Witnessed proper tests, including shutdowns.
Fire Fighting › Fire Main
Issued 19 November 2003 Resolved
CROPP AND RENEW WASTED SECTIONS OF FIRE MAIN PIPING LOCATED IN PORT SIDE OVERHEAD ENGINE ROOM. TO BE COMPLETED IN DECEMBER 2003 DRY DOCK. TWO WEEP HOLES LOCATED APPROX 6 FEET APART, FIRE MAIN PRESSURE SAT. LEGACY COMPONENT DESC: Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 20 January 2004
Engineering › Compressed Air System (control)
Issued 19 November 2003 Resolved
PREFORM FIVE YEAR INSPECTIONS OF ALL AIR RECEIVERS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR. TO BE COMPLETED IN DECEMBER 2003 DRY DOCK. SHIPS FORCE CONDUCTED HYDRO OCT 03. DUE TO VESSEL OPERATIONS, AIR RECEIVERS WERE NOT INTERNALLY/HYDRO INSPECTED. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 20 January 2004
Deck/Cargo
Issued 19 November 2003 Resolved
VEE AND WELD DECK FRACTURE LOCATED IWO 2ND INBOARD STANCHION PORT QUARTER. TO BE COMPLETED IN DECEMBER 2003 DRY DOCK, OR BEFORE VESSEL IS TO TRANSIT COASTWISE. LEGACY COMPONENT DESC: DECK
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 20 January 2004
Lifesaving › Immersion Suits
Issued 19 November 2003 Resolved
REPAIR/ REPLACE IMMERSION SUITS AS FALLOWS: REPAIR ZIPPER OR REPLACE SUIT. ADHEAR VELCRO TO FACE PIECE WITH APPROVED GLUE. REDUCED COI PERSONS ALLOWED (INDUSTRIAL PERSONNEL) TO 10 UNTIL CORRECTED. CURRENTLY BARGE CARRIES 5 INDUSTRIAL PERSONNEL.
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 20 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 5 November 2002 Resolved
PROVE PROPER OPERATION OF OWS PRIOR TO OPERATION IN U.S. WATERS, OR REMOVE SYSTEM AND BLANK FLANGE DISCHARGE PIPE. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 13 November 2002
Resolution: OWS WAS REMOVED FROM VESSEL.
Documentation › Certificates/Documents
Issued 5 November 2002 Resolved
PROVIDE LAST INSPECTION DATE FOR 2001 RE-INSPECTION. MISLE SHOWS NO RECORDS OF A 2001 RE-EXAM. ORIGINAL COI WAS NOT ONBOARD, VESSEL HAD A COPY OF COI, WITH NO SIGNATURE OR AMMENDMENTS OF A RE-EXAM , REQUESTED ORIGINAL BE PROVIDED AS PROOF OF INSPECTION WITH PROPER ENDORSMENTS OR AMMENDMENTS LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 30 December 2002
Resolution: OWNERS/VESSEL REP NOT ABLE TO PRODUCE RECORDS INDICATING A RE-EXAM HAD TAKEN PLACE FOR 2001. ISSUED NEW COI FOR REMAINING THREE YEARS OF ORIGINAL COI, AND RECEIVED ORIGINAL 5 YEAR COI TO FORWARD TO I.O.''s FOR FURTHER ACTION.
Construction/Loadline
Issued 8 February 1999 Resolved
COMPLETE PROPER REPAIRS TO DECK PLATING AND INTERNAL STRUCTURAL MEMBERS IN WAY OF ENGINE ROOM HATCH AND GERERATOR INSTALLATION. REPAIRS ARE TO BE TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Electrical
Issued 8 February 1999 Resolved
PROVE PROPER OPERATION OF NEW INSTALLATION OF CRANE GENERATOR TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Fire Fighting
Issued 24 November 1998 Resolved
MAKE ALL FIRE HOSES AVAILABLE TO TEST AT 100 PSI OR PROVIDE SATISFACTORY EVIDENCE OF SAME.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Electrical
Issued 24 November 1998 Resolved
REPAIR/REPLACE/CORRECT ALL EXPOSED, IMPROPERLY RUN, OPEN OR TERMINATED WIRING IN THE CRANE OPERATION/MACHINERY AREA. CURRENTLY, MANY RUNS OF ELECTRICAL WIRE ARE OPEN, EXPOSED OR IMPROPERLY RUN WHICH MAY PRESENT EITHER A FIRE OR PERSONNEL HAZARD IF ENGERIZED.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Unknown
Issued 24 November 1998 Resolved
REPAIR AND PROVE PROPER OPERATION OF MAIN FIRE PUMP AND PROVE PUMP IS CAPABLE OF DELIVERING APPROXIMATELY 50 PSI TO DECK STATIONS.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Unknown
Issued 24 November 1998 Resolved
REPLACE SAFETY RELIEF VALVES TO STARTING AIR RECEIVERS TO RELIEVE AT OR BELOW 165 PSI.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998 Resolved
PROVIDE APPROVED DRAWINGS WHICH INDICATE ACCEPTANCE OF "FIELD INSTALLED" HATCH/EMERGENCY EGRESS FROM STERN "SPUD" & WINCH ROOM WHERE DECK LONGITUDINAL IS CUT AWAY. CURRENTLY, THIS STRENGTH MEMBER IS CUT ENTIRELY IN HALF AT TWO LOCATIONS TO ALLOW FOR INSTALLATION OF HATCH.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998 Resolved
MAKE PERMANENT REPAIRS TO LOWER PORTION OF BLKD IWO ENGINE ROOM ACCESS SHACK WHERE WASTED (PORT SIDE). THE BLKD IS WASTED JUST ABOVE MAIN DECK JOINT DUE TO AGE & EXCESSIVE CORROSION.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998 Resolved
MAKE WATERTIGHT DOOR ON MAIN DECK LEADING DOWN BELOW TO GALLEY/ENGINEERING OFFICE WATERTIGHT. CURRENTLY, DOOR DOES NOT SEAL SHUT.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Construction/Loadline
Issued 24 November 1998 Resolved
MAKE PERMANENT REPAIRS TO PORT & STBD "SPUD" CASING FRAMES IWO THE DECK GUSSET WHERE FRACTURED FROM REPEATED HITS BY THE SPOIL BARGE OR MANUEVERINGTUG. FRACTURES APPEAR TO PENETRATE DECK IN CERTAIN LOCATIONS ON EACH SIDE.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Engineering
Issued 24 November 1998 Resolved
MAKE PERMANENT REPAIRS TO PORT/STBD FUEL TANK VENTS WHERE WASTED OR PROVIDESUFFIENT PROOF THAT STRUCTURAL INTEGRITY OF EACH PIPE STAND IS ACCEPTABLE.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Accommodation/Occupational Safety
Issued 24 November 1998 Resolved
MAKE EMERGENCY EXIT/EGRESS FROM GALLEY AREA TO MAIN DECK WATERTIGHT._x001C_ CURRENT HATCH COVER DOES NOT SEAL.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Unknown
Issued 24 November 1998 Resolved
LABEL REMOTE FUEL AND ENGINE SHUT DOWNS.
Condition: Unknown
Due 24 November 1998
Resolved 24 November 1998
Unknown
Issued 17 November 1997 Resolved
OILY WATER SEPARATOR'S PIPING HAD NOT BEEN RIGGED FOR PROPER DISCHARGE OF OILY WATER RESIDUE OVERBOARD. ISSUED REQUIREMENT TO DEMONSTRATE PROPER OPERATION OF OWS. OILY WATER RESIDUE IS RETAINED O/B AND DISCHARGED FROM VSL VIA VAC TRUCK IN PORT.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 4 December 1996 Resolved
PROVIDE PROPER CLOSURE/SEAL FOR THE BULKHEAD PENETRATIONS OF THE FORWARD AND AFTER MACHINERY SPACE BULKHEADS.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Fire Fighting
Issued 4 December 1996 Resolved
RENEW THE INSULATION THAT HAS BEEN REMOVED ON THE MACHINERY SPACE FORWARD STARBOARD BULKHEAD.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Engineering
Issued 4 December 1996 Resolved
PROVE THE PROPER OPERATION OF THE LOW LUBE OIL ALARM FOR THE MAIN ENGINE.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Documentation
Issued 14 June 1995 Resolved
PRIOR TO DEPARTING THE PORT OF PASCAGOULA BY SEA PROVIDE A CURRENT LOADLINECERTIFICATE.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Accommodation/Occupational Safety
Issued 14 June 1995 Resolved
PROVIDE CERTIFIED LAB ANALYSIS OF THE CONTENTS OF THE OVERBOARD DISCHARGE FROM THE MSD HOLDING TANK.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Accommodation/Occupational Safety
Issued 2 August 1994 Resolved
REATTACH CATWALK IN CRANE DECKHOUSE.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Electrical
Issued 2 August 1994 Resolved
INSTALL CORRECT WIRING TO RESISTOR PANELS LOCATED ABOVE SWITCHBOARD IN CRANE HOUSE. PLASTIC TY-WRAPS ARE INSUFFICIENT. ALSO, ENSURE PROPER WIRING IS USED FOR INTENDED APPLICATION. "SO" CABLE IS NOT AUTHORIZED._x001C_ _x001C_
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Engineering
Issued 2 August 1994 Resolved
HYDROSTATICALLY TEST BOTH AIR RECEIVERS LOCATED IN MAIN GENERATOR ROOM TO 1.25 MAWP. INTERNAL EXAMINATION SHOWED PITTING AND CORROSION.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 2 August 1994 Resolved
STENCIL VESSEL NAME ON LIFERINGS.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Electrical
Issued 2 August 1994 Resolved
REPAIR EMERGENCY LIGHTING FIXTURE TEST BUTTONS AND ENSURE LIGHTING WORKS PROPERLY UPON LOSS OF MAIN ELECTRICAL POWER.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Engineering
Issued 2 August 1994 Resolved
REPLACE RUBBER FUEL PRESSURE GAGE LINE WITH STEEL OR EQUIVALENT.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Fire Fighting
Issued 2 August 1994 Resolved
REMOVE PLASTIC FIRE HOSE NOZZLES AND REPLACE WITH CG-APPROVED NOZZLES.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Electrical
Issued 2 August 1994 Resolved
INSTALL GUARD OVER SEWAGE PUMP MOTOR COUPLING
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Construction/Loadline
Issued 2 August 1994 Resolved
ENSURE WX-TIGHT ENCLOSURE IN WAY OF 2800 VOLT MG SWITCHBOARD IN CRANE HOUSE.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Accommodation/Occupational Safety
Issued 14 February 1994 Resolved
HYDRO OR INTERNALLY EXAMINE 4 PRESSURE VESSELS.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Documentation
Issued 14 June 1993 Resolved
PROVIDE CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Documentation
Issued 14 June 1993 Resolved
VESSEL NOT TO BE OPERATED UNTIL COMPLETION OF REINSPECTION.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Documentation
Issued 14 June 1993 Resolved
PROVIDE PROOF OF VESSEL DOCUMENTATION.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Electrical
Issued 19 March 1991 Resolved
PROVIDE COVER FOR ELECTRICAL BOX AFT WORK LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Deck/Cargo
Issued 19 March 1991 Resolved
REPLACE CRACKED WINDOW IN CRANE CONTROL STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
REMOVE DEAD END WIRING ROM VOID UNDER CRANE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Unknown
Issued 19 March 1991 Resolved
REPLACE RELIEF VALVE S/S IR RECEIVER WITH VALVE PROVIDED WITH HAND RELIEVING GEAR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
PROPERLY SPLICE AND INSTALL WIRES CLOSING WIRE BRAKE CONTROLLER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Fire Fighting
Issued 19 March 1991 Resolved
REPLACE HOSE FIRE STATION #2 & 4 WITH UL APPROVED RUBBER LINED HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
REPLACE TWIST-TYPE SPLICE CONNECTOR ON BOILER WIRING WITH CRIMP TYPE SPLICECONNECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
PROVIDE PROPER BOX FOR RACAL BATTERIES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
REPAIR OR REPLACE DOOR LATCHES IN PANEL P19-9, L3 IN MACHINERY ROOM AND BRAKE CONTROLLER , PORT SPUD ROOM_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Electrical
Issued 19 March 1991 Resolved
REPLACE MISSING FLUORESCENT LIGHT COVERS AFT SPUD ROOM_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Engineering
Issued 14 March 1990 Resolved
REPLACE GASKET AND ADJUST HANDLES ON THE BOILER DOOR AS SO TO BE AIR TIGHT.TO BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Engineering
Issued 14 March 1990 Resolved
REPLACE WIRENUTS ON THE BURNER CONTROL WITH WIRE CRIMABLE CONNECTORS. TO BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Navigation
Issued 7 March 1990 Resolved
RENEW THE STARBOARD LOWER RUNNING LIGHT (RESTRICTED IN ABILITY TO MANEUVER WARNING LIGHT). DUE PRIOR TO NIGHT DREDGING OPERATIONS.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Lifesaving
Issued 7 March 1990 Resolved
MARK THE EXPOSURE SUITS WITH THE VESSEL'S NAME IN ACCORDANCE WITH 46 CFR 97.37-43(A).
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Documentation
Issued 7 March 1990 Resolved
PROVIDE COPIES OF LIFERAFT AND FIRE EQUIPMENT SERVICING REPORTS TO THE OCMIBY MAIL.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Fire Fighting
Issued 7 March 1990 Resolved
PROVIDE A FIRE AXE IN THE ENGINEROOM MARKED WITH THE VESSEL'S NAME.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Fire Fighting
Issued 7 March 1990 Resolved
PROPERLY MARK FIRE STATION #3.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Engineering
Issued 7 March 1990 Resolved
BLANK THE PORTSIDE FUEL STATION QUICK CONNECT FITTING.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Construction/Loadline
Issued 7 March 1990 Resolved
REPAINT THE LOADLINE, BOW NAME AND DRAFT MARKS AS NEEDED.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Fire Fighting
Issued 7 March 1990 Resolved
RENEW THE HYDRANT VALVE AT FIRE STATION #1.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Accommodation/Occupational Safety
Issued 7 March 1990 Resolved
DEMONSTRATE OPERATION OF THE MSD CHLORINATOR.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Engineering
Issued 7 March 1990 Resolved
CONDUCT AN OPERATIONAL TEST OF THE BOILER AND ALL BOILER SAFETY DEVICES IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Engineering
Issued 7 March 1990 Resolved
CONDUCT A HYDROSTATIC TEST OF THE BOILER.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Engineering
Issued 7 March 1990 Resolved
CONDUCT A HYDROSTATIC TEST OH THE THREE ENGINEROOM AIR RECEIVERS.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Fire Fighting
Issued 7 March 1990 Resolved
CONDUCT A HYDROSTATIC TEST OF ALL FIRE HOSE.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Electrical
Issued 22 March 1989 Resolved
PROVE PROPER OPERATION OF OVERSPEED ON AUXILIARY GENERATOR.
Condition: Unknown
Due 22 March 1989
Resolved 22 March 1989
Lifesaving
Issued 22 March 1989 Resolved
PROVIDE PROOF-OF-PROPERLY SERVICED HYDROSTATIC RELEASE UNIT.
Condition: Unknown
Due 22 March 1989
Resolved 22 March 1989
Electrical
Issued 22 March 1989 Resolved
PROVIDE GLOBES AND GUARD FOR LIGHTING FIXTURES WHERE NEEDED.
Condition: Unknown
Due 22 March 1989
Resolved 22 March 1989
Engineering
Issued 22 March 1989 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDWON ON MAIN ENGINE AND AUXILIARY GENERATOR.
Condition: Unknown
Due 22 March 1989
Resolved 22 March 1989
Lifesaving
Issued 22 March 1989 Resolved
PROVIDE SIX ADDITIONAL APPROVED PFD'S (ADULT)
Condition: Unknown
Due 22 March 1989
Resolved 22 March 1989
Unknown
Issued 30 March 1988 Resolved
REPLACE OR RECALIBRATE SAFETY VALVE ON BOILER.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Fire Fighting
Issued 30 March 1988 Resolved
REPLACE TWO FIRE HOSES WITH APPROVED 1-1/2" FIRE HOSE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Lifesaving
Issued 30 March 1988 Resolved
INSTALL INFLATABLE LIFE RAFT WITH CAPACITY OF 12 OR MORE PERSONS. VESSEL IS PROHIBITED FROM CARRYING MORE THAN 10 PERSONS UNTIL THIS ITEM IS COMPLETED
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Unknown
Issued 30 March 1988 Resolved
PROVIDE OIL TRANSFER PROCEDURES & DESIGNATION OF PERSON IN CHARGE AS PER 33CFR 155.750 & 33CFR 155.700.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Accommodation/Occupational Safety
Issued 24 April 1987 Resolved
MAKE THE FRESH WATER TANK AVAILABLE FOR STAMPING BYA MARINE ISPECTOR FROM MIO PHILADELPHIA.
Condition: Unknown
Due 24 April 1987
Resolved 24 April 1987
Accommodation/Occupational Safety
Issued 20 May 1986 Resolved
PROVIDE FRESH WATER TANK WHICH COMPLIES WITH 46 CFR PART 54.
Condition: Unknown
Due 20 May 1986
Resolved 20 May 1986
Engineering
Issued 25 April 1986 Resolved
REMOVE BOILER MOUNTINGS FOR INSPECTION IN ACCORDANCE WITH 46 CFR 61.05-15.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Engineering
Issued 25 April 1986 Resolved
REPAIR AND PROVE PROPER OPERATION OF BOILER RELIEF VALVE, LOW WATER CUTOUT,AND FLAME FAILURE INCLUDING PRUGE CYCLES.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Fire Fighting
Issued 25 April 1986 Resolved
PROPERLY STENCIL HOSE STATIONS.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Lifesaving
Issued 25 April 1986 Resolved
PROVIDE PROPER I.D. TAG FOR INFLATABLE LIFERAFT WEAK LINK.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Fire Fighting
Issued 25 April 1986 Resolved
PROVIDE PROPER FIRE NOZZLES FOR HOSE.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Lifesaving
Issued 25 April 1986 Resolved
PROVIDE 12 EXPOSURE SUITS IN SUITABLE LOCATION ON VESSEL.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Accommodation/Occupational Safety
Issued 25 April 1986 Resolved
PROVIDE DOCUMENTATION ON FLEXIBLE HOSE IN FUEL, WATER AND COMPRESSED AIR SYSTEMS AS PER TABLE 46 CFR 56.60-25(C).
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Construction/Loadline
Issued 25 April 1986 Resolved
PROVIDE STRIKER PLATES AND SOUNDING TUBES FOR LUBE OIL TANKS, OR EQUIVALENT.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.