Inspection history · 46
26 September 2025
COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8240583
12 December 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8046410
30 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8011633
12 August 2024
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7980305
5 January 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7845580
18 October 2023
Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810335
6 March 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646542
3 October 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7571013
31 August 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7517301
3 January 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7375192
21 July 2020
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7012104
4 May 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6947941
1 April 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6934344
22 July 2019
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758196
15 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6626526
24 January 2018
Administrative Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6342858
7 January 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6346995
8 August 2017
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6242322
8 July 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5796253
14 May 2015
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5129221
3 August 2014
VRP Review
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4943600
29 May 2014
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4877586
10 February 2014
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4797892
18 August 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4710021
5 March 2013
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4543865
26 February 2013
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4544247
5 January 2012
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 4225927
25 May 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4022560
9 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2817760
26 October 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2808642
19 March 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2664760
11 March 2006
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2606593
15 December 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2260342
25 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2207442
22 February 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1488575
7 February 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1486127
12 March 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 163740
24 January 2000
Uninspected Towing Vessel
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814334
6 October 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 786281
17 September 1997
Uninspected Towing Vessel · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1115985
19 February 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 140969
29 November 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 47855
14 August 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 40539
7 January 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 86175
27 January 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 148260
19 August 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 59551
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and dire and shock hazards.
a portable surge protector was observed being used as the primary power source for the submersible pump, chargers and equipment in use in the engine room. Provide power to the equipment using permanent means.46CFR143.400
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2025
Resolution: Rcvd picture of deficiency rectified.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 September 2025
Resolved
Alarms must be visible and audible. The alarm at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. The vessels bilge indicators in the machinery room had a shared alarm for the Laz/ER. 46CFR143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2025
Resolution: Rcvd picture of deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2025
Resolved
Switchboard was missing non conductive mat, Open gaps were observed where planking plates or protective covers should be fitted and cleaning supplies were found stored behind the switchboard.46CFR143.400
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2025
Resolution: Rcvd picture of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 September 2025
Resolved
A 40B fire extinguisher must be located near a storage room or cabinet carrying flammable or combustible products. 2 storage rooms labeled as flammable lockers were found without a 40B extinguisher nearby. 46CFR142.225
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2025
Resolution: Rcvd picture of deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 26 September 2025
Resolved
Vessel did not have documentation of fire, abandon ship, man overboard or flooding drills. Drills must be kept in the TVR, or official logbook. 46CFR140.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2025
Resolution: Rcvd picture of deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 26 September 2025
Resolved
Vessels steering tower appeared to be inoperable, crew reported that it is no longer functional, however electrical hazards were found in the tower. Submit a determination to decommission the steering tower and move vital/electrical equipment to the wheel house or remove hazards and prove satisfactory operation of navigational equipment. 46CFR140.205
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 October 2025
Resolution: Rcvd picture of deficiency rectified.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 12 December 2024
Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available. Provide master who has valid medical certificate to meet manning requirements.
46 CFR 10.302(a)
Action required: 705 - Other - as specified
Resolved 14 January 2025
Resolution: Medical provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2024
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245. All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. MAWP stamp, nameplate not visible. Provide name plate for pressure vessel.
46 CFR 143.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 13 March 2025
Resolution: Name plate found. Was under support strap. Added photo to documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2024
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. Pressure vessel relief valves need to be tested twice every 5 years, with no more than 3 years since last test. Testing of pressure relief valves not completed. Complete testing of pressure relief valves.
46 CFR 143.245
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 13 March 2025
Resolution: Relief valve tested and recorded in engineeres log book.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2024
Resolved
The aft hydraulic steering ram was found with 3 of 4 bolts attaching it to the framing structure and one bolt was found to be lose. Provide hydraulic ram with 4 bolts and properly torque all hardware.
Cite: 46 CFR 143.205
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2024
Resolved 19 August 2024
Resolution: Bolt was tightend.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2023
Resolved
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel went into emergency dry dock for repairs due to unusual noise and vibrations from starboard engine and shaft.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 17 November 2023
Resolution: Vessel made successful transit back to San Diego.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 October 2023
Resolved
When conducting an examination of a towing vessel as required by this subpart, the surveyor must determine whether any defect, deterioration, damage, or modifications of the hull and related structure and components may adversely affect the vessel's seaworthiness or fitness or suitability for its route or service. (b) The examination must address the items in § 137.330 as applicable, and must include: (1) Access to internal spaces as appropriate; (2) A visual examination of the external structure of the vessel to confirm that the condition is properly maintained; and (3) A visual examination to confirm that unapproved modifications were not made to the vessel. (c) The thoroughness and stringency of the examination will depend upon the condition of the vessel. (d) The owner or managing operator must notify the cognizant OCMI when the condition of the vessel may create an unsafe condition. The vessel is at Marisco Shipyard, Honolulu Hi, conducting repairs without Coast Guard Oversight. Vessel is a Coast Guard Option inspected vessel under 46 CFR 137. Vessel must complete CG inspection of repairs prior to any towing operations.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2023
Resolved 19 October 2023
Resolution: Attend vessel and witness final repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 October 2022
Resolved
Engine room remote fuel shut off valves for both PORT & STBD generators failed to operate; faulty. Repair or replace valves.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2022
Resolution: Replaced valves in kind, OP test ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2022
Resolved
Steering control electrical enclosure panel cover missing at Portside steering unit; re-install cover.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 14 October 2022
Resolution: Installed missing cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2022
Resolved
Heat detector in overhead of engine room found hanging from wiring; remount.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 14 October 2022
Resolution: Properly re- installed heat detector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2022
Resolved
Vessel flammable lockers found to have paint spilled and oil soaked rags being stored inside. Clean spilled paint and discard oil soaked rags.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2022
Resolved 14 October 2022
Resolution: Cleaned flammable lockers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2022
Resolved
Flammable lockers found to have ventilation holes in the sides preventing CO2 extinguishers from being effective. Plug holes if flammable lockers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 14 October 2022
Resolution: Installed metal plugs to properly seal locker enclosure.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 October 2022
Resolved
Stair-tower providing access to top control station found to be missing emergency lighting. Install emergency lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2022
Resolved 14 October 2022
Resolution: Installed E-Lighting in stair tower; OP test ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 January 2022
Resolved
Aft Towing station 02 weather deck lighting missing bulb diffuser. Re-Install bulb diffuser.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
Resolution: CORRECTED
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 January 2022
Resolved
PORT side life ring buoy; remove permanent lanyard that secures marker light to buoy, renew ring buoy line and retro-tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
Resolution: CORRECTED
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 January 2022
Resolved
Port side Deck Flammable locker fire extinguisher at station #12 servicing by GFS expired on November 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
Resolution: CORRECTED
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 January 2022
Resolved
Remove dryer ducting from galley exhaust hood and replace with rigid piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
Resolution: CORRECTED
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 3 January 2022
Resolved
Repair STBD MDE exhaust lagging where holed. (near winch generator and in stack)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 January 2022
Resolution: RECEIVED PHOTO OF REPAIR
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 July 2020
Resolved
PORT F/O SHUTOFF VALVE IS INOPERABLE FROM OUTSIDE THE SPACE. ENSURE PROPER OPERATION PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2020
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 July 2020
Resolved
PORT AFT F/O ISOLATION VALVE FOR TRANSFER PIPING IS INOPERABLE. ENSURE PROPER OPERATION AND DOCUMENT IN VESSEL FUEL SYSTEM MAINTENACE PLAN AS REQUIRED.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2020
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 July 2020
Resolved
ENSURE ALL ESCAPE HATCHES ARE MARKED ON BOTH SIDES IN AT LEAST 2" LETTERS "EMERGENCY EXIT, KEEP CLEAR".
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2020
Resolved
INDIVIDUAL CIRCUIT BREAKERS ON SWITCHBOARDS AND DISTRUBUTION PANELS MUST BE LABELED WITH A DESCRIPTION OF THE LOADS THEY SERVE.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 July 2020
Resolved
INSTALL BLANKS ON ELECTRICAL PANEL TO MINIMIZE SHOCK HAZARDS TO PERSONNEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 July 2020
Resolved
PROPERLY INSTALL A SAFETY GUARD OVER ROTATING MACHINERY.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2020
Resolved
IDENTIFY SOURCE OF HYDRAULIC LEAK IN AFT ENGINE ROOM
CENTERLINE.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2020
Resolved
PROPER MOUNT F/O STAINER/FILTER HOUSING FOR PORT SSDG.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2020
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 April 2020
Resolved
Vessel must provide required life raft prior to departure. Vessel had no liferaft at time of Inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2020
Resolved 6 April 2020
Resolution: Six (06)-man SOLAS 'A' pack Inflatable Liferaft was provided. Number of crew was reduced to the carriage of six (06) persons until an Eight (08)-man Liferaft can be provided.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 3 April 2020
Resolved
Vessel is restricted to Domestic Service until vessel meets SOLAS requirements
Action required: 702 - Prior to embarking on international voyage
Resolved 8 May 2020
Resolution: see narrative for description
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 April 2020
Resolved
Bilge Alarm is required to be audible at operating station. Alarm was not audible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2020
Resolved 6 April 2020
Resolution: Alarm was tested and operated properly with audible sound at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 April 2020
Resolved
Vessel's COD shows Hailing Port as New York, NY. Vessel must update COD to reflect San Diego, Ca. as the Hailing Port.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2020
Resolved 8 May 2020
Resolution: addressed, verified the current COD
Personnel › Certificates/Documents/Licenses › PIC
Issued 3 August 2014
Resolved
Failure to comply with requirements for oil transfer.
Cite: 33CFR156.120
Due 3 August 2014
Resolved 4 August 2014
Resolution: PIC provided documentation confirming PIC designation.
Lifesaving
Issued 17 September 1997
Resolved
PROVIDE PROOF EPIRB IS REGISTERED WITH NOAA, AND AFFIX NOAA DECAL TO EPIRB.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 17 September 1997
Resolved
UPON COMPLETION OF SERVICING FIXED CO2 SYSTEM PROVIDE COPY OF SERVICING REPORT.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Accommodation/Occupational Safety
Issued 17 September 1997
Resolved
UPON COMPLETION OF INSTALLATION OF TYPE II MSD SYSTEM PROVIDE COPY OF INSTALLATION REPORT, AND SPECIFICATIONS.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Lifesaving
Issued 17 September 1997
Resolved
PROVIDE (3) MISSING PFD'S.
Condition: Unknown
Due 17 September 1997