Inspection history · 84
14 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8357887
5 May 2025
Drydock Exam · Periodic Inspection · In-Service Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8129201
22 October 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8023123
8 April 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7892065
10 May 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7685244
23 March 2022
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417223
28 February 2022
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7403678
28 February 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7408124
19 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7157865
10 February 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6913028
19 June 2019
Administrative Inspection · Periodic Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6719558
3 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6725014
27 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6457738
10 March 2017
COI Inspection · Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102689
15 August 2013
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4686018
9 October 2012
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4460102
20 August 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4416989
25 April 2012
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4295255
10 April 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4283268
15 March 2012
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4264564
7 June 2011
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4037334
27 July 2010
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3820488
13 July 2010
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3800677
22 June 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3530015
19 June 2009
Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3508399
4 February 2009
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3412496
8 February 2008
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3144313
26 June 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2974884
12 April 2007
Annual Inspection · Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2909387
6 December 2006
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2832149
16 November 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2822171
24 March 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2608069
27 February 2006
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2592707
19 April 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2337201
21 July 2004
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2140567
29 June 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2114667
17 February 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2007877
4 February 2004
Hull Examination · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2000331
10 January 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1981248
25 March 2003
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1762559
8 July 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1642970
6 March 2002
Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1491623
22 February 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1488575
23 January 2002
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1480815
27 November 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422130
11 October 2001
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1419011
21 June 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1467301
5 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 732508
9 May 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1063320
4 April 2001
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1443196
29 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 211388
1 March 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1058387
15 February 2001
Re-Inspection · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1379307
28 March 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 822294
28 March 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408569
29 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2288
18 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114363
25 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 673461
22 June 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464206
24 May 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424742
29 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213617
22 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126175
15 April 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 673452
10 April 1998
Deadweight Survey · MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1440000
7 April 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 44162
20 June 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1111776
25 March 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165758
11 March 1994
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1167877
29 September 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 845362
3 September 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1138318
23 August 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1155737
3 June 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1133379
28 April 1993
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835411
11 February 1992
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1267583
3 September 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 654787
16 July 1991
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1248363
11 February 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 924146
15 February 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 927792
8 September 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041751
14 June 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1034532
14 June 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1341670
14 June 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1352054
18 April 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200076
31 March 1988
Initial Certification · Hull Examination · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891946
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 April 2024
Resolved
Each vessel must meet the applicable requirements in subchapter S of this chapter. Each class 1 door on a vessel must be designed to withstand a head of water. Marine Inspector observed paint on all watertight door knife edges. Knife edge to the HPU space wasted. Clean paint off knife edge within 14 days; permanent repairs knife edge to HPU space at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Received objective evidence of bare knife edges and repair to to HPU space door.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 16 April 2024
Resolved
Each cable entrance in a damp or wet location must be made watertight by a terminal or stuffing tube. All around white navigation light has a junction box that has loose cable stuffing and has two openings to the environment. Repair.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
Resolution: Received objective evidence of proper connections to and from junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 16 April 2024
Resolved
Equipment for interior locations not requiring exceptional degrees of protection must be with drip shield. Install.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
Resolution: Received objective evidence that drip shield was installed.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 7 July 2023
Resolved
In the event of alterations involving the safety of the
vessel, the applicable plans shall be submitted for
approval covering the proposed work except as modified
by §91.45–1. The general scope of the plans shall be as
noted in §91.55–5.
The vessel could not produce documentation verifying
that plan review as required by 46 CFR 91.55-1 had been
conducted by the Marine Safety Center (MSC). The vessel
shall contact MSC and submit all applicable plans and
information required by 46 CFR 51.55-5 within 90 days
from the date noted on this form.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2023
Resolved 23 October 2023
Resolution: Received MSC report finalizing plan review and accepting PE as reviewer as per NVIC 10-92.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 10 May 2023
Resolved
The requirements for muster lists, emergency signals, and manning must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter.
Vessel's station bill and muster list indicates the requirement for 7 people while operating as the unloader barge during the day shift. Vessel is only allowed to have 6 industrial personnel on board at all times.
46 CFR 97.13-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 14 June 2023
Resolution: Resolved company change their muster list iaw with COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2023
Resolved
Each battery tray must be chocked with wood strips or their equivalent to prevent movement, and each tray must have non-absorbent insulating supports on the bottom and similar spacer blocks at the sides, or equivalent provisions for air circulation space all around each tray.
Battery trays were found without wood strips or equivalent spacers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Received objective evidence of satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2023
Resolved
Cable retention devices should be installed not less than every 610 mm on vertical runs and not less than
every 2.5 m on horizontal runs. At turns of horizontal runs, cable retention devices should be spaced not
more than 610 mm apart. Nylon or plastic retaining devices may be used in horizontal runs where cables will
not fall if the retention devices fail. When nylon or plastic cable retaining devices are employed on exterior
cable runs, they should be of a type resistant to ultraviolet light (sunlight).
Horizontal cable runs were missing adequate cable straps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Receive objective evidence of repairs being conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2023
Resolved
Each panelboard switching unit must be numbered. Each panelboard must have:
(1) A circuit directory cardholder; and
(2) A circuit directory that has:(i) The circuit designation of each circuit; (ii) A description of the load of each circuit; and (iii) The rating or setting of the overcurrent protective device for each circuit.
Some distribution/circuit-breaker panels were missing proper labelling designation of load provided.
46 CFR 111.40-11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2023
Resolved 26 May 2023
Resolution: Received objective evidence of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 March 2022
Resolved
Life raft had painter hooked up incorrectly causing it to not be float free. Corrected on spot.
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2022
Resolved
Reach rods for fuel shut off valves for Port & STBD fuel tank low suctions were missing bolts and inoperable in condition found. Corrected of spot.
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 April 2022
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2012
Resolved
Renew wasted main deck cable support trays through out vessel as needed.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 20 August 2012
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 16 May 2012
Resolved
Renew governor control wiring for main deck pump engine.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 20 August 2012
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 May 2012
Resolved
Renew wasted lifelines on periphery of the main deck as needed.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 20 August 2012
Resolution: corrected
Fire Fighting › Fire Pumps › Gland Sealing
Issued 16 May 2012
Resolved
Renew or repack fire pump packing.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 18 June 2012
Resolution: corrected
Communications › Alarms/Indicators › General Alarm
Issued 16 May 2012
Resolved
Repair inoperable general alarm and properly mark.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 18 June 2012
Resolution: corrected
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2012
Resolved
Vessel is overdue for hull examination. Prior to operations, conduct credit drydock.
Action required: 705 - Other - as specified
Due 15 April 2012
Resolved 10 April 2012
Resolution: Vessel voluntarily surrendered COI.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2010
Resolved
Prove proper operation of main generator within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Observed proper operation and tested required shutdowns.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2010
Resolved
Prove proper operation of auxilary generator within 30 days.
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Observed proper operations and tested shutddowns.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 13 July 2010
Resolved
Replace and install lagging on exposed areas of generator (auxilary) exhaust within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Replaced lagging on all exposed areas.
Communications › Alarms/Indicators › General Alarm
Issued 13 July 2010
Resolved
Prove operation on visual general alarms in generator room, room adjacent to generator room, and fire pump room within 30 days.
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: observed proper operation of required alarms in all spaces.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 13 July 2010
Resolved
Mount fire extinguisher in fire pump room within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: replaced missing portable fire extinguisher.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 July 2010
Resolved
Replace retro-reflective material on ring life buoy within 30 days.
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Replaced Retro-reflective tape on liferings
Lifesaving › Inflatable Liferafts › Not on Board
Issued 13 July 2010
Resolved
Install liferaft to the satisfication of the attending Coast Guard marine inspector within 30 days.
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Installed liferaft and provided certification from agency upon completion of annual requirement.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 July 2010
Resolved
Provide crew manifest prior to operation.
Action required: 705 - Other - as specified
Due 12 August 2010
Resolved 27 July 2010
Resolution: Corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 June 2009
Resolved
Provide proof of servicing for all fire extinguishers prior to operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 September 2009
Electrical › Electric Generation Source (service) › Generator
Issued 22 June 2009
Resolved
Prove proper operation of main generator prior to operation.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2009
Resolved
Provide current certificate of documentation (COD) on board the vessel.
Action required: 705 - Other - as specified
Resolved 23 June 2009
Resolution: Current certificate of documentation provided.
Electrical › Electric Generation Source (service) › Switch
Issued 22 June 2009
Resolved
Remove and replace battery switches on spud winch motor to be completed during drydock.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Electrical › Electric Generation Source (service) › Generator Cable
Issued 22 June 2009
Resolved
Remove dead end wires on generator block heater to be completed during drydock.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2009
Resolved
Provide metal wire supports on booster winch engine wiring to be completed during drydock.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 22 June 2009
Resolved
Prove proper operation of booster engine, overspeed and low lube shutdowns prior to operation.
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Diesel Engine (auxiliary) › Bedplate
Issued 22 June 2009
Resolved
Discover and repair source of the water leak under the booster engine to be completed during drydock.
Action required: 705 - Other - as specified
Resolved 22 June 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 June 2009
Resolved
Provide original COI onboard vessel.
Action required: 705 - Other - as specified
Resolved 11 September 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 February 2008
Resolved
Replace all dry-chemical fire extinguisher brackets to properly fit newly installed fire extinguishers’. Complete by 14 March 2008.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2008
Resolved 2 March 2008
Resolution: New brackets were provided with all new fire extinguishers put o/b by the o/o.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 8 February 2008
Resolved
Repair as original 480 power panel controller box located off of the main generator room on the main deck. Complete by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 8 February 2008
Resolved
Repair all oil leaks in way of auxiliary generator set including main seal and fuel piping.To be completed prior to end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2008
Resolved
Permanently mount 480 power cable in way of auxiliary generator along out board bulkhead. To be completed by 1 MAY 2008
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 23 February 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2008
Resolved
Repair as original limit switch stops in way of snorkel To be completed by 1 MAY 2008
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 23 February 2008
Engineering › Reduction Gearing/Clutches › Line Shaft
Issued 8 February 2008
Resolved
Repair oil leaks on booster engine, Gear box and PTO Drive. To be completed by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Fuel Oil Service System › Filter
Issued 8 February 2008
Resolved
Repair all oil leaks in way of main generator including accumulated in engine vee and secondary filters. To be completed by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 February 2008
Resolved
Repair exhaust leaks in main generator. To be completed by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 8 February 2008
Resolved
Repair hydraulic valve in way of #2 Jet Pump. To be completed by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Operations/Management › Pollution › Control of Discharge of Oil
Issued 8 February 2008
Resolved
Repair oil leaks on Snorkel Boost pump. To be completed by end of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 8 February 2008
Resolved
Replace port fuel vent flame screen. To be completed by 01 May 2008
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 23 February 2008
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 February 2008
Resolved
Remove oil from containment box from Skid and containment bowls from Racors in way of booster engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 23 February 2008
Engineering › Fuel Oil Service System › Piping
Issued 8 February 2008
Resolved
Repair service tank fuel piping in way of soft patch and jubilee patch in suction pipe from service tanks to day tank prior to completion of next dry dock or prior to vessel resuming normal operation which ever occurs first.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 September 2009
Engineering › Lubricating Oil Service System › Valve, Control
Issued 8 February 2008
Resolved
Prove proper operation of auxiliary generator emergency shutdown. To be completed by 14 March 2008
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 23 February 2008
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 8 February 2008
Resolved
Prior to Barge re-locating ensure all pollution containment and stowage of oily waste drums are properly secured and cleaned.. To be completed prior to departing current location.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 December 2006
Resolved
Must install flange blank for pipe terminating in stbd fwd spud void.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Resolution: Completed
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 December 2006
Resolved
Remove or tagout dead end cable/wire in galley above hatch for port void aft of fuel tanks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Resolution: Removed.
Construction/Loadline › Hull › Side Shell
Issued 6 December 2006
Resolved
Make proper repairs to (2) cracks and inset located in fwd stbd rake side shell approximately 2' below sheer 12' aft. Provide repair proposal prior to commencing repairs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Resolution: Completed.
Documentation › Logs/Records › Enhanced Survey Report File
Issued 6 December 2006
Resolved
Provide copy of underwater survey.
Action required: 705 - Other - as specified
Due 15 December 2006
Resolved 11 January 2007
Resolution: Received vhs tape
Construction/Loadline › Structures › Scuttle
Issued 6 December 2006
Resolved
Provide chains and gaskets for deck scuttles and prove proper operation.
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Resolution: Corrected
Construction/Loadline › Penetrations › Weld
Issued 6 December 2006
Resolved
Crop and replace deck by stbd fwd spud on main deck w/2 penetrations.
Action required: 705 - Other - as specified
Due 18 January 2007
Resolved 18 January 2007
Resolution: Corrected with 18" x 12" insert on deck, w/ original plate thickness.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2006
Resolved
Owner/operator is not to conduct any operations until a credit hull exam is completed to the satisfaction of an attending Marine Inspector, NLT 16 December 2006.
Action required: 705 - Other - as specified
Due 16 December 2006
Resolved 18 January 2007
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 19 April 2005
Resolved
Repair the exhaust leak on the auxiliary generator.
Condition: Unknown
Due 19 May 2005
Resolved 5 May 2005
Engineering › Fuel Oil Service System › Filter
Issued 19 April 2005
Resolved
Remove plastic petcocks from all Raycor fuel filters and replace with metal petcocks or metal plugs.
Due 19 May 2005
Resolved 5 May 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 19 April 2005
Resolved
Install flame screen on sewage tank vent.
Due 19 May 2005
Resolved 5 May 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 April 2005
Resolved
Replace water light clips with corrosion resistant clips.
Due 19 May 2005
Resolved 5 May 2005
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 19 April 2005
Resolved
Replace light covers as necessary in control room.
Due 19 May 2005
Resolved 5 May 2005
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2004
Resolved
Prove proper operation of the AUX generator with shutdowns.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2004
Resolved 21 July 2004
Communications › Radio Communications › EPIRB
Issued 29 June 2004
Resolved
Renew the hydrostatic release for the EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2004
Resolved 21 July 2004
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 June 2004
Resolved
Provide a copy of the vessels waste management plan onboard the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2004
Resolved 21 July 2004
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 June 2004
Resolved
Provide a copy of the Oil Transfer Procedures onboard the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2004
Resolved 21 July 2004
Construction/Loadline › Hull
Issued 6 March 2002
Resolved
Proceed to repair facility no later than 16MAR02 to make repairs to damaged hull plating and structuaral members IWO port void. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 March 2002
Resolved 13 March 2002
Resolution: Repairs completed
Construction/Loadline › Structures
Issued 14 January 2002
Resolved
REMOVE FLAMABLE INSULATION FROM OVERHEAD OF ELECTRICAL CONTROL ROOM. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 8 July 2002
Resolution: ALL OLD FLAMABLE INSULATION IN CONTROL ROOM OBSERVED REMOVED. NEW INSULATION IN PROCESS OF BEING INSTALLED BY LOCAL CONTRACTOR.
Documentation › Certificates/Documents
Issued 11 October 2001
Resolved
PROVIDE PERSON IN CHARGE DESIGNATION LETTER.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical
Issued 11 October 2001
Resolved
PROVIDE SUITABLE RUBBER INSULATING MATTING ON DECK OF ELECTRICAL CONTROL ROOM.
Condition: Improper Installation
Due 29 November 2001
Resolved 29 November 2001
Engineering › Compressed Air System (start air)
Issued 11 October 2001
Resolved
RENEW SAFETY RELIEF VALVE HANDLE ON AIR RECEIVER. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Lifesaving › Inflatable Liferafts
Issued 11 October 2001
Resolved
PROPERLY ATTACH HYDROSTATIC RELAEAS ON LIFERAFT LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Due 29 January 2002
Resolved 29 November 2001
Lifesaving › Lifejacket/PFD (Type V)
Issued 11 October 2001
Resolved
PROVIDE SIX IMMERSION SUITS LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2001
Resolved
INSURE PROPER WIRING CONNECTIONS MADE ON ALL JUNCTION BOXES IN PUMP ROOM.
Condition: Improper Installation
Due 29 November 2001
Resolved 29 November 2001
Resolution: CORRECTED
Engineering › Compressed Air System (start air) › Valve
Issued 11 October 2001
Resolved
PROVE SAFETY RELIEF VALVES FOR AIR RECEIVERS
Condition: Damaged By Earlier Event
Due 29 November 2001
Resolved 29 November 2001
Deck/Cargo
Issued 15 February 2001
Resolved
PROVIDE VESSEL WITH AN ANCHOR IAW 46 CFR 96.07.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Construction/Loadline
Issued 15 February 2001
Resolved
MAKE PERMANENT REPAIRS TO THE FRACTURES IN BOTH FWD AND AFT SPUD GUIDE NO LATER THAN NEXT SHEDULED DRYDOCK 31JUN01, TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 February 2001
Resolved 15 February 2001
Documentation
Issued 28 March 2000
Resolved
Provide original COFR w/ correct name,
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Fire Fighting
Issued 28 March 2000
Resolved
Submit for approval, plans for paint locker fixed fire fighting system.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Construction/Loadline
Issued 28 March 2000
Resolved
Provide gasket for #1 stbd void hatch.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Lifesaving
Issued 28 March 2000
Resolved
Label all ring buoys with correct vessel name.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Lifesaving
Issued 28 March 2000
Resolved
Label all PFD's w/ correct vessel name.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Unknown
Issued 28 March 2000
Resolved
Affix correct vessel name on the hull.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Lifesaving
Issued 28 March 2000
Resolved
Provide calibrated gaughe for 20 gallon air receiver.
Condition: Unknown
Due 10 April 2000
Resolved 9 August 2000
Documentation
Issued 3 June 1993
Resolved
PROVIDE OCMI JACKSONVILLE WITH A COPY OF VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY (COFR) AND INTERNATIONAL OIL POLUTION PREVENTION CERTIFICATE. THIS REQUIREMENT IS TO BE SATISFIED PRIOR TO OPERATION OF THEVESSEL.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Accommodation/Occupational Safety
Issued 28 April 1993
Resolved
Provide & prove relief valve on large air receiver, 125 psi maximum.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Documentation
Issued 28 April 1993
Resolved
Provide O.C.M.I. Jacksonville with a copy of valid Loadline Certificate.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Accommodation/Occupational Safety
Issued 28 April 1993
Resolved
Repair cable rail stancions where broken at deck.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Documentation
Issued 28 April 1993
Resolved
Provide O.C.M.I. Jacksonville a copy of vald Certificate of Financial Responsibility & International Oil Pollution Prevention Certificate.
Condition: Unknown
Due 15 May 1993
Resolved 3 June 1993
Lifesaving
Issued 28 April 1993
Resolved
Install retroreflective tape on all life ring buoys.
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Unknown
Issued 14 June 1989
Resolved
THE COMPRESSED AIR RECEIVERS MUST COMPLY WITH 46CFR PART 54, AND THE COMPRESSED AIR PIPING MUST COMPLY WITH 46CFR 58.30.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Engineering
Issued 18 April 1989
Resolved
PROVIDE COPY OF NAME PLATE DATE FOR AIR RECEIVERS.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989