Records from 1989 to 2011. Most recent: casualty investigation, 2 October 2011.
Documentation record
Registered dimensions (L × B × D)68.0 ft × 36.0 ft × 6.3 ft
Registered tonnagegross 171 / net 140
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROWN POINT INDUSTRIES · JEAN LAFITTE, LA, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it171 - Regulatory (Subpart C or D), Gross Ton
140 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
24 February 2011
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3955716
21 February 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4013119
17 December 2010
Administrative Inspection · MTSA Verification · Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3912588
3 December 2009
Examination of Repairs · Internal Structural Exam · Re-Inspection · Drydock Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3694276
29 January 2009
Ballast Water Examination · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3402104
16 November 2007
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3099706
18 October 2007
MTSA Verification · Ballast Water Examination · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3082198
14 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961547
9 June 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2674696
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539820
3 October 2005
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2506926
8 September 2005
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2487528
25 October 2004
Hull Examination · Examination of Repairs · MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2227607
23 December 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1975243
31 January 2003
Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1738141
12 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1660136
3 June 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1627089
26 October 2001
Hull Examination · COI Inspection · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1475018
8 February 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429494
7 October 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395275
21 December 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461102
18 December 1997
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428870
27 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114636
13 November 1996
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439803
14 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087161
26 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419520
20 October 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883390
24 October 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446130
2 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 851699
7 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159913
30 November 1993
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459064
25 October 1993
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415904
7 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 829835
22 February 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834988
24 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 33852
23 November 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463019
2 July 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362636
26 June 1992
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370485
8 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 128434
22 November 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939654
5 November 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247622
18 June 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920796
20 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907847
13 September 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926872
7 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909705
26 October 1989
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225427
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 October 2007
Resolved
Replace navigation light main pannel in pilot house
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 16 November 2007
Resolution: provided
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 25 October 2004
Resolved
Provide ballast water management plan for vessel per NVIC 07-04 change 1.
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 15 December 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 25 October 2004
Resolved
Provide seperate means of propulsion control outside of pilothouse per NVIC 1-78.
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 15 December 2005
Resolution: Provided.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 25 October 2004
Resolved
Provide fire detection in P/S E/R's per NVIC 1-78.
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 15 December 2005
Resolution: Provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 25 October 2004
Resolved
Provide means to monitor shaft RPM's in E/R per NVIC 1-78.
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 15 December 2005
Resolution: provided.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 October 2004
Resolved
Provide mud basket strainer at bilge pump inlet per 46CFR56.50-50(g).
Action required: 705 - Other - as specified
Due 24 December 2004
Resolved 25 October 2004
Lifesaving
Issued 7 October 1999
Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENT ON OFFSHORE SUPPLY VESSEL DATED 12NOV98 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Documentation
Issued 23 November 1992
Resolved
SUBMIT LEG STRENGTH CALCULATIONS TO MARINE SAFETY CENTER WASHINGTON, D.C. FOR APPROVAL.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Construction/Loadline
Issued 26 June 1992
Resolved
COMPLETE PERMANENT REPAIR TO TEMP REPAIR ON MAIN DECK, INSERT IN WAY OF DOUBLER PLATE OVER CRACK APPROX. 2'X 2' AMIDSHIPS.
Condition: Unknown
Due 26 July 1992
Resolved 3 July 1992
Unknown
Issued 26 October 1989
Resolved
SUBMIT A OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Documentation
Issued 26 October 1989
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Documentation
Issued 26 October 1989
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, FIRE CONTROL PLAN AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Lifesaving
Issued 26 October 1989
Resolved
INSTALL A SUITABLE MEANS OF ESCAPE.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Unknown
Issued 26 October 1989
Resolved
PROVIDE APPROVED TILT ALARM.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989