Records from 1986 to 2019. Most recent: inspection, 22 July 2019.
Documentation record
Registered dimensions (L × B × D)207.4 ft × 54.6 ft × 22.0 ft
Registered tonnagegross 1,955 / net 815
ITC dimensions (L × B × D)207.4 ft × 54.6 ft × 22.0 ft
ITC tonnagegross 1,955 / net 815
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1986
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1955 - Convention (Subpart B), Gross Ton
815 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
22 July 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6773896
26 August 2016
Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5977507
4 September 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1280
12 February 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 85805
23 October 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1183129
13 October 1993
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1358185
11 September 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 945862
29 May 1992
Examination of Repairs · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258731
4 May 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359399
10 October 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 935044
17 September 1991
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1249018
6 September 1991
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1257068
30 November 1990
Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1224946
18 September 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194249
15 September 1989
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351787
13 April 1989
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198520
14 September 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1042148
9 September 1987
Initial Certification · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1002668
27 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339431
29 May 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1337550
30 September 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1313885
Construction/Loadline
Issued 4 May 1992
Resolved
Make permanent repairs to the #9 transverse frame (bulkhead separating the #3 and #4 port voids) which is buckled.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992
Resolved
Make permanent repairs to the first and second longitudinal frames and associated bottom plating between transverse frames #7 and 11 in the #3_x001C_ and 4 port side voids.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992
Resolved
Make proper and permanent repairs to the torn plating and associated framing in the port forepeak.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992
Resolved
Until permanent repairs are made, conduct internal inpsections every 90 days of the damage previously noted in the #3 and 4 port voids. Log this inspection and provide a condition report to: Marine Safety Detachment / 111 Harbor Way / Santa Barbara, CA 93109-2315
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Documentation
Issued 4 May 1992
Resolved
Provide proof that vessel has a valid Certificate of Financial Responsibility for water pollution to: Marine Safety Detachment_x001C_ 111 Harbor Way_x001C_ Santa Barbara, CA 93109-2315
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Deck/Cargo
Issued 6 September 1991
Resolved
Prove proper operation to the hydraulic drive machinery on deck. To be completed by 10 Oct 1991.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Electrical
Issued 15 September 1989
Resolved
RENEW BATTERY CABLE OF REMOTE CONTROL BATTERY.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989
Electrical
Issued 15 September 1989
Resolved
PROVIDE COVER FOR FOWARD MAIN BATTERY.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989
Deck/Cargo
Issued 15 September 1989
Resolved
OPERATE AND TEST PRIME MOVER FOR HYDRAULICS.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989