MAURY USCG vessel records Sign in
← All vessels

SEA PORT

SEA PORT is a 1986 industrial vessel. The Coast Guard has recorded 21 inspections since 1986, most recently in July 2019, along with 9 deficiencies.

Records from 1986 to 2019. Most recent: inspection, 22 July 2019.

Built
1986
Last inspected
22 July 2019
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

267476
Flag
UNITED STATES
—
Maury page id
psix-267476

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (1986–2019)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)207.4 ft × 54.6 ft × 22.0 ft
Registered tonnagegross 1,955 / net 815
ITC dimensions (L × B × D)207.4 ft × 54.6 ft × 22.0 ft
ITC tonnagegross 1,955 / net 815
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1986
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1955 - Convention (Subpart B), Gross Ton
815 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MIKE O'LEARY Towing Vessel · MISLE 135720 · 12 February 1998 · activity 85805

Inspection history · 21

22 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6773896
26 August 2016 Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5977507
4 September 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1280
12 February 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 85805
23 October 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1183129
13 October 1993 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1358185
11 September 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 945862
29 May 1992 Examination of Repairs · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258731
4 May 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359399
10 October 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 935044
17 September 1991 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1249018
6 September 1991 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1257068
30 November 1990 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1224946
18 September 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1194249
15 September 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1351787
13 April 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198520
14 September 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1042148
9 September 1987 Initial Certification · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1002668
27 August 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1339431
29 May 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1337550
30 September 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1313885

Deficiency record · 9

Construction/Loadline
Issued 4 May 1992 Resolved
Make permanent repairs to the #9 transverse frame (bulkhead separating the #3 and #4 port voids) which is buckled.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992 Resolved
Make permanent repairs to the first and second longitudinal frames and associated bottom plating between transverse frames #7 and 11 in the #3_x001C_ and 4 port side voids.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992 Resolved
Make proper and permanent repairs to the torn plating and associated framing in the port forepeak.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992 Resolved
Until permanent repairs are made, conduct internal inpsections every 90 days of the damage previously noted in the #3 and 4 port voids. Log this inspection and provide a condition report to: Marine Safety Detachment / 111 Harbor Way / Santa Barbara, CA 93109-2315
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Documentation
Issued 4 May 1992 Resolved
Provide proof that vessel has a valid Certificate of Financial Responsibility for water pollution to: Marine Safety Detachment_x001C_ 111 Harbor Way_x001C_ Santa Barbara, CA 93109-2315
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Deck/Cargo
Issued 6 September 1991 Resolved
Prove proper operation to the hydraulic drive machinery on deck. To be completed by 10 Oct 1991.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Electrical
Issued 15 September 1989 Resolved
RENEW BATTERY CABLE OF REMOTE CONTROL BATTERY.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989
Electrical
Issued 15 September 1989 Resolved
PROVIDE COVER FOR FOWARD MAIN BATTERY.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989
Deck/Cargo
Issued 15 September 1989 Resolved
OPERATE AND TEST PRIME MOVER FOR HYDRAULICS.
Condition: Unknown
Due 15 September 1989
Resolved 15 September 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.