GULF ISLANDER

Built
1986
Last inspected
4 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC4523
268039
Flag
UNITED STATES
Maury page id
psix-268039

Documentation record

Registered dimensions (L × B × D)101.4 ft × 24.0 ft × 8.9 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPROGRESSIVE SHIPBUILDERS · HOUMA, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGULFPORT, MS
Endorsements, as the file codes themcw_un
DocumentationValid · issued 11 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

APALACHEE GIRL Commercial Fishing Vessel · MISLE 422078 · 29 March 2023 · activity 7667522

Inspection history · 22

4 February 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8305976
14 October 2025 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8251662
28 February 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8086316
3 February 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074038
7 November 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821362
4 May 2023 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624422
29 March 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7667522
13 December 2022 In-Service Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609006
2 February 2022 Administrative Inspection · DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7389825
4 January 2021 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7119572
4 January 2021 Annual Inspection · MTSA Verification · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7144753
6 November 2019 MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6850895
31 October 2019 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6846196
8 January 2019 Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6607252
7 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6576805
2 February 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6349761
23 October 2017 Administrative Inspection · MTSA Verification · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6294427
17 January 2017 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072236
13 December 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6057890
18 November 2016 DAPI Audit · Annual Inspection · Administrative Inspection · Security Plan Review - ASP
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6044019
31 March 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5844762
9 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5830555

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2026 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. MI identified an inoperable pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2026
Resolved 25 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2026 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces. MI observed high water alarm was neither audible or visual for the steering gear lazarette.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2026
Resolved 25 February 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2024 Resolved
The settings of the safety or relief valves on all pressure vessels must be examined twice every 5 years. The vessels PRV's were beyond 3 yrs since last test.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 16 April 2024
Resolution: Vessel sent in pics of new replaced safety relief valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2024 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J–1942 or USCG Type A1, A2, B1, or B2 flexible hose. Vessel had 2 hoses on the stbd generator that were not type approved.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 16 April 2024
Resolution: Vessel sent in pics of new approved fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. All of the vessels Racor fuel filters had large amounts of growth in them. 01 had visible cracking of the bottom bowl and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 16 April 2024
Resolution: Vessel sent in pics of new filters along with new metallic filter bottoms.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 February 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Several life float pennants were found worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 16 April 2024
Resolution: Vessel sent in pics of new pennants on life float.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found one recepticle in the galley that had the hot and neutral wires switched and one in the tool room with a open ground.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 11 March 2024
Resolution: Vessel sent inphotos of the new recepticles with a tester plugged in indicating sat results.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 February 2024 Resolved
All portions of machinery bulkheads must be watertight below the bulkhead deck. Vessel had 01 penetrations on the aft engine room bulkhead, stbd side that was not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 16 April 2024
Resolution: Vessel sealed up machinery penetration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2023 Resolved
Vessels bilge alarms did not have an audible alarm.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Vessel repaired audible alarm and tested in the presence of attending MI. Cleared on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2022 Resolved
Proper installation and testing of main engines, auxiliary engines, and propulsion engine control systems shall be conducted to the satisfaction of the attending marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2023
Resolved 26 April 2023
Resolution: Conducted satisfactory DVTP's on the vessel with the exception of 1 which will be conmducted during the annual exam on 04May23. Activity # 7624422.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2019 Resolved
Identified a leak on the vessels port MDE raw water pump. Vessel is to repair or replace the raw water pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 13 January 2020
Resolution: Vessel replaced R/W pump.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 December 2017 Resolved
Vessel required to post a Fire Control PLan that is accessible to crew and passengers. Vessel did not have a Fire Control Plan posted. Provide/post a Fire Control Plan.
Action required: 705 - Other - as specified
Due 6 January 2018
Resolved 2 February 2018
Resolution: Fire plan completed and posted.
Stability › Watertight Integrity › Coaming
Issued 30 November 2016 Resolved
Adjust laz escape hatch so that it properly secures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 13 December 2016
Resolution: Escape hatch adjusted to properly secure.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 November 2016 Resolved
Adjust fuel shut off valve so that it completely opens when activated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 30 November 2016
Resolution: Adjusted to work properly.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 30 November 2016 Resolved
Exhaust on starboard main engine missing hose clamp. Apply a hose clamp to make secure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 13 December 2016
Resolution: Hose clamp added.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 30 November 2016 Resolved
Guage inoperable on the hydraulic steering system. Replace or repair guage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 13 December 2016
Resolution: New guage installed.
Stability › Watertight Integrity › General
Issued 30 November 2016 Resolved
WTD light when opened not operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 13 December 2016
Resolution: Light at operating station working properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.