MAURY USCG vessel records
← All vessels

ALASKAN DREAM

ALASKAN DREAM is a 1986 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2016, most recently in March 2026, along with 118 deficiencies and 5 casualty investigations between 2005 and 2021.

Records from 2005 to 2026. Most recent: inspection, 18 March 2026.

Built
1986
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8978679
WDF7895
270111
Flag
UNITED STATES
Maury page id
psix-270111

Documentation record

Registered dimensions (L × B × D)95.8 ft × 36.0 ft × 10.8 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)86.5 ft × 36.8 ft × 10.8 ft
ITC tonnagegross 490 / net 182
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 3 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it490 - Convention (Subpart B), Gross Ton
93 - Regulatory (Subpart C or D), Gross Ton
182 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

18 March 2026 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8328411
8 July 2025 In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8182887
14 May 2025 Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8136262
1 May 2025 Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8127679
12 February 2025 Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8083905
23 June 2024 Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7941509
1 May 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7904350
17 November 2023 Administrative Inspection · Special Consideration · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7836752
12 October 2023 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813066
24 June 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7726798
18 May 2023 COI Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7684020
29 April 2023 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7688400
24 January 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7626632
21 December 2021 Administrative Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7372043
29 September 2021 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7353748
5 June 2021 Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7220035
4 June 2021 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7220982
3 May 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7188199
6 March 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7151222
16 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7096515
28 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6962950
7 April 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6936680
6 November 2019 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6850631
3 October 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6827684
18 March 2019 Hull Examination · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6644906
9 October 2018 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6558876
21 August 2018 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6524548
4 August 2018 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6502838
18 April 2018 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6394098
12 October 2017 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6287196
20 April 2017 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6130794
11 October 2016 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6021949
20 September 2016 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6006967
3 May 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5870854
29 April 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5867413

Deficiency record · 118

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025 Resolved
182.25-10(a) All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Over 65 feet, any number of passengers is required 02 fixed power pumps. Starboard side bilge pump is seized.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Engineer conducted maintenance on pump, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2025 Resolved
182.530(a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Port and starboard laz high water alarms were not indicating both audible and visual at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Installed new high water switch, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2025 Resolved
185.410(b)(1) The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive. Roving watchman system is not alerting all spaces as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Replaced master head, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025 Resolved
180.70(c)At least one ring life buoy must be fitted with a lifeline, 60 feet in length. One ring life buoy is required to have be fitted with a lifeline of at least 60 ft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Installed life line, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2025 Resolved
181.30-10(b) Portable fire extinguisher& shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher port side on the pilothouse has incorrect bracket for extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Installed larger extinguisher to match bracket, All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 14 May 2025 Resolved
(1) Lighting fixtures shall be constructed in accordance with the requirements of Underwriters Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters Laboratories, Inc. "Marine Type" label. or shall be constructed accordance with the requirements of other recognized testing laboratories. Observation deck port side forward deck light has a bad gasket allowing water to enter. Install new gasket or replace fixture.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: Instlled new gasket. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2025 Resolved
176.830(a) At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Refrigerator on 200 deck aft starboard side needs secured for sea.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 16 May 2025
Resolution: New bracket fabricated and installed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MSD control cabinet door was not properly secured. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Cabinet was properly secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Port CO2 space electrical panel labeled "Engine Room Panel 5" was missing blanks. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Blanks were properly installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were found hanging in front of MSD tank. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Dead end wires were for the aft engine room light. Wires were reconnected to the light.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 May 2024 Resolved
The minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Pump gauge was broken. 46 CFR 181.300
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Pressure gauge was replaced and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 May 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Stbd engine room electrical outlet on the left side of the ladder was missing the cover plate. 46 CFR 183.340(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Cover plate was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 8 May 2024 Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. Both engine room exhaust fans were reversed and not providing exhaust ventilation. 46 CFR 182.465(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Engine room exhaust fans were reveresed and provided exhaust to the space.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter). Aft 100 deck portable fire extinguisher was past due for annual servicing. 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: Fire extinguisher was serviced.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 May 2024 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Starboard HALON schematic diagram of the system was missing. 46 CFR 185.612(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: Schematic diagram was placed at the cylinders.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 May 2024 Resolved
Each item of lifesaving equipment with an expiration date must be replaced during the annual inspection and replaced if the expiration date has passed. Onboard flares were found expired. 46 CFR 185.726(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: Expired flares were replaced with new ones.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2024 Resolved
Except as otherwise required by paragraphs (b) and (c) of this section, an existing vessel must comply with the fire protection equipment regulations applicable to the vessel on March 10, 1996, or, as an alternative, the vessel may comply with the regulations in this part. Port HALON bottle was removed for servicing and was not installed at time of inspection. 46 CFR 181.115
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: Halon bottles was replaced and properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 1 May 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Liferaft hydrostatic release units were past the marked expiration date. 46 CFR 185.740(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2024
Resolution: Expired hydrostatic release units were replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 October 2023 Resolved
New installations of fire protection equipment on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection on or after March 11, 1996, must comply with the regulations of this part. System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Vessel has new installation of fixed fire protection equipment serving the port and starboard engine room. The fixed fire suppression system design and installation is questioned by the OCMI. Provide approval by the Marine Safety Center (MSC). 46 CFR 181.115 (c) 46 CFR 181.410 (a)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Drawing of previously approved fixed FF system was provided. The installation was verified IAW drawing and found to be correct.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 October 2023 Resolved
All calculations required by this subchapter must be submitted with the plans required by §170.075 of this subpart, Calculations must account for the weight of all loads carried aboard the vessel. Vessel had additional loads on board to include freezers and a canopy; Vessel's stability is questioned by the OCMI. Provide documentation of MSC approval of added loads after the April 12, 2005 Deadweight Survey. 46 CFR 170.090 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Canopy was installed IAW original design. In 2007 an addition to the canopy was installed with side curtains and extended aft. Pictures were located and due to the canopy addition not being approved it was removed and is currently original to the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023 Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996 must comply with this part. Vessel had new installations of loads to include large freezers and air conditioning units that were questioned by the OCMI. Vessel also had replacement of wire and cable that were of insufficient wire gauge as well as daisy chained outlets from a single breaker. Provide documentation of MSC approval or complete a new electrical one line diagram for approval. 46 CFR 183.115 (c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Wiring was replaced to correct gauge. Daisy chained outlet was corrected and equipment was properly installed to a new breaker which received local OCMI approval. Updated one line diagram and load analysis will be completed at the end of tourims season.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2023 Resolved
A water heater must meet the requirement of Part 53 and 63 in subchapter F of this chapter if rated at not more than 689 kPa and 121 degrees Celsius, except that an electric water heater is also acceptable if it is protected by a pressure-temperature relief device. Water heater relief valves were rusted/seized and needs to be exercised to show proper operation. 46 CFR 182.320 (a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Pressure relief valves were replaced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Dampers leading to the port and starboard engine room does not fully fit the duct and does not fully prevent the admission of air into the space protected. 46 CFR 181.20-95 (OLD T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Fire dampers were repaired and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 October 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have an interconnected fire detection system in compliance with § 181.450.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Interconnected fire detection system has been installed and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 12 October 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Nightwatchman alarm has been installed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Vessel hull had several holes found below layers of paint. Vessel to blast paint to make bare metal hull accessible during next credit drydock. 46 CFR 176.25-5 (OLD T)
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 15 March 2025
Resolution: Identified areas were cropped and renewed in kind during 2025 DDX.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions. Both port and starboard electrical controller enclosures for the generator do not close properly due to excessive rust on hinges and missing latches. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 20 June 2023
Resolved 1 May 2024
Resolution: Electrical enclosures were descaled and repainted. Broken hinges and latches were replaced and operate as designed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. All navigation lights were inoperable. 46 CFR 183.420
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2023
Resolved 20 May 2023
Resolution: All nav lights are functioning properly.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 May 2023 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system in Room 300 and 02 Deck Port Crew Room was inoperable. 46 CFR 184.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: All speakers were repaired and tested sat.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 May 2023 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Upper deck light on starboard side and light in Captains stateroom were missing the covers. 46 CFR 183.410
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: All covers were replaced and installed properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 May 2023 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Port side CO2 space was missing the diagram and the starboard CO2 space was missing instructions and diagram. 46 CFR 185.612
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: Simple instructions and diagrams were installed in the appropriate locations.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Port forward AC unit is missing the cover for the electrical components. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: AC unit cover was installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 May 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Alcohol breathalyzer was not calibrated within 12 months. 46 CFR 185.212
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: Appropriate number of alcohol swabs were placed onto the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 May 2023 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC Station license was expired. 47 CFR 80.13
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2023
Resolution: FCC station license was renewed and placed onto the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 May 2023 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD was not located on vessel at the time of inspection. COD was located and placed onto the vessel prior to completion of inspection. 46 CFR 67.313
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: COD was located and placed onto the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2021 Resolved
Both the port and stbd generators overheated to the point of shutdown. The port generator raw water discharge pipe developed a one inch crack aprox 6" up from were the pipe is connected to the generator engine exhaust overboard pipe.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2021
Resolved 6 June 2021
Resolution: Crew weld repaired the crack in the raw water pipe, cleaned the raw water supply piping and coolers on the engines. Test ran sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2021 Resolved
Provide fire detectors in all overnight cabins that meet 46 CFR 181.405(c).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Not applicable to Old T vessels. However, vessel representative installed fire detectors in all overnight cabins
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 May 2021 Resolved
Repair or replace frozen door knob in Chef's cabin door.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Observed satisfactory door operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Flammables found throughout the vessel improperly stored. Properly store flammables in flam locker of remove from vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Flammables were found properly stored.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Electrical fuse panels for hot water heaters on aft 3rd deck show sign of significant overheating. Provide 3rd party electrical survey from certified marine electrician or electrical engineer attesting to proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Hot water heater serviced by Cooper Marine Services LLC. Cooper Marine Services provided electrical survey (attached into documents). Fuse panel and repairs were found satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 May 2021 Resolved
Provide current hydrostatic release for 406 EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 29 May 2021
Resolution: Observed satisfactory HRU & properly installed EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 May 2021 Resolved
Properly install IBAs.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: IBAs were found propery installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Remove or properly terminate dead end wire in HVAC systems 4th deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Dead end wire was removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Repair or replace broken electrical outlet on base of mast, 4th deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Electrical outlet was satisfactorily replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 May 2021 Resolved
Remove or replace first aid kit on the wall aft, deck 2.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 3 May 2021
Resolution: Repair or replace broken light fixture in hall deck two, fwd.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Repair or replace broken light fixture in hall deck two, fwd.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory repairs to light fixture.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Provide an appropriate power outlet to eliminate the need for extension cord for portable AC unit in fwd "View Suites" passenger cabins. *alterations to vessel electrical system requires approved plans.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory power outlet arrangement without extension cord for portable AC unit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Provide GCFI electrical outlet in cabin 203 at sink outlet.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory GCFI outlet in cabin 203.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Replace broken spanner wrench at deck two fire main.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory spanner wrench installation.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 May 2021 Resolved
Provide fire detection testing and service report for vessel's fire detection and suppression systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Vessel representative provided satisfactory servicing report Order # 29223 from Southeat Extinguisher Service INC. dated 7MAY2021.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Replace missing switch cover on aft bulkhead of hotel manager's cabin.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory switch cover.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Remove or properly enclose exposed wiring inside of top of hotel manager closet on right side.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Exposed wiring was removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Repair or replace missing outlet cover on deck 2 aft deck electrical outlet.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory outlet cover.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 May 2021 Resolved
Prove proper operation of Engine Room ventilation dampers
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory operation of engine room ventilation dampers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Remove chains and storage capabilities in port engine room entrance that inhibits the fire suppression warning sign from being seen or change location of sign.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Vessel removed chains from location.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Properly secure from movement laundry machine on aft deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified secured laundry machine.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Remove 12v battery from aft starboard main deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Battery was removed from main deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Adjust cabin door into galley on starboard side to prevent from rubbing on fire suppression system box.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory arrangement of cabin door.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Replace missing outlet cover on outlet for wine cooler fwd starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified installed outlet cover.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Properly secure refrigerator in hotel manager cabin.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified that refridgerator was satisfactorily secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Repair broken ground wire on compressor for HVAC on port side deck 1 HVAC.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfacoty repair of HVAC ground wire.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2021 Resolved
Repair broken water tank ventilation piping support on bow.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory repair to water tank ventilation piping.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 May 2021 Resolved
Prove proper operation of bow anchor windlass.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory operation of bow anchor windlass.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021 Resolved
Replace broken HVAC coolant line in HVAC system in engineer's cabin that services STBD dinning room.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory HVAC coolant line.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Repair or replace missing thermostat assembly in engineer's cabin.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory thermostat assembly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Several chest freezers and refrigerators found added throughout the vessel (06 total). They all need to be secured in place to prevent movement in heavy weather.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 29 May 2021
Resolution: Vessel installed brackets to secure all remaining freezers onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Added Freezers and refrigerators need a power source that does not require an extension cord. *Modifications to vessel electrical systems require approved plans prior to modification.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Vessel removed added freezers/refridgerators and extension cords.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Provide a load analysis to MSC for approval for all added freezers and refrigerators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2021
Resolved 27 May 2021
Resolution: Vessel removed added freezers and refridgerators not in accordance with one line electrical drawing s81-5031-1.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Prove proper operation of port generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 29 May 2021
Resolution: Observed satisfactory operation of Port generator.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 May 2021 Resolved
Prove proper operation of STBD E/R ventilation.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory operation of stbd E/R ventilation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Replace missing lagging for STBD generator exhaust piping.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory lagging on starboard exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2021 Resolved
Prove proper operation of all bilge manifold valves.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory operation of bilge manifold valves.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 3 May 2021 Resolved
Provide new indicator lamps for MSD electrical panel.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 27 May 2021
Resolution: Verified satisfactory installation of new indicator lamps for MSD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
Remove liquid level fuel gauges in both engine rooms or meet 46 CFR 182.20.25(a)(5). If removed provide means of determining fuel level.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2021
Resolved 29 May 2021
Resolution: Vessel installed satisfactory sight gauges IAW "Old T" 46CFR182.20-25(a)(5).
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 April 2020 Resolved
While the vessel is engaged in towing the vessel must be controlled by a licensed Master or Mate of towing. Vessel has until April 1st 2022 to man vessel with licensed Master and Mate of towing.
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 29 September 2021
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 April 2020 Resolved
Vessel must provide updated stability calculations to include towing to Coast Guard Marine Safety Center to update vessels stability letter by April 1st 2022
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 29 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2020 Resolved
Vessel shall provide correct light and day shape configuration for the tow being conducted prior to towing.
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 27 May 2021
Resolution: Verified satisfactory towing light and day shape.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 April 2020 Resolved
Vessel shall start and maintain records for towline and terminal gear used for towing astern or alongside prior to towing
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 27 May 2021
Resolution: Verified documentation was on board.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 November 2019 Resolved
Determine source of water ingress in port rudder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Found crack in top leading edge of rudder. Drill stopped crack, grinded out and welded. Pressed up to 5 psi and no leaks detected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2019 Resolved
Drill stop and gouge out crack in starboard stem and weld.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019 Resolved
Replace starboard engine room bilge inboard strainer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2020
Resolution: Strainer installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 November 2019 Resolved
Make cabin/hull mounts available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2020
Resolution: Mounts inspected. All inboard mounts replaced with new mounts.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 November 2019 Resolved
Crop and renew to good aluminum wasted transom plating in starboard side swim step void space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2020
Resolution: Area properly repaired. See narative for details.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 November 2019 Resolved
Crop and renew wasted gussets in swim step void space along aft transom plate at bottom plate intersection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2020
Resolution: Area properly repaired see narative for details.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2019 Resolved
Provide U/T shots of wastage in forward water tanks internal sideshell.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2020
Resolution: UT conducted with no areas of wastage requiring attention. Results scanned into vessel documents.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 November 2019 Resolved
Make sea valves available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2019
Resolution: Inspected (06) sea valves.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 October 2019 Resolved
Port side engine room fixed halon system, pull knob for engine shut-down missing pull knob. Replace missing pull knob.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: New Pull knob was installed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 October 2019 Resolved
Starboard side engine room fixed halon system, pull knob for generator shut-down missing pull knob. Replace missing pull knob.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2021
Resolution: New Pull knob was installed and found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 3 October 2019 Resolved
Update emergency instructions to include abandon ship procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2021
Resolution: Emergency instructions posted on bridge were found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2019 Resolved
Vessel shall have two fixed power bilge pumps, port bilge pump was not available for testing.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Witnessed a satisfactory operational test of the port bilge pump and the cross connect.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 March 2019 Resolved
Liferafts must be serviced no later than the month and year on its servicing sticker, all liferafts were beyond their serviceable dates.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified sufficient survival crafts were provided, installed, and maintained.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 March 2019 Resolved
Vessel must be outfitted with a Cat 1, 406MHz EPIRB, no EPIRB was provided. Vessel restricted to less than three nautical miles from shore.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Verified an EPIRB was provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 March 2019 Resolved
The vessel's firemain was winterized/not available for inspection, prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Witnessed an operational test of the vessel's firemain.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 March 2019 Resolved
Underway drills are required to be conducted and logged at least once every three months, vessel rep was unable to provide logs or records indicating such.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Vessel provided log entry indicating drills were conducted at the proper interval.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 18 March 2019 Resolved
A vessel must not operate without a valid SPV decal affixed to the vessel, provided SPV decals were expired.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 22 April 2019
Resolution: SPV devals were provided and affixed to the vessel.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 March 2019 Resolved
A visual and audible bilge high level alarm must be provided at the operating station, demonstrate starboard engine room and troubleshoot starboard lazz alarm.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Witnessed a satisfactory test of the bilge high level alarms.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 March 2019 Resolved
Pilot house visual bilge high level alarms were improperly labeled.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Verified labels were reflective of the space protected.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 March 2019 Resolved
Repair or replace the emergency light located on the aft bridge deck passageway.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verfied the identified light was renewed and operational.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 March 2019 Resolved
Emergency fuel shutoff valves were not available for testing.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Witnessed an operational test of the remote fuel shutoff valves.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 March 2019 Resolved
Each lighting fixture must be fixed, fix or repair fixture hanging from the wires in the port engine room.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Verified the light fixture was remounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2019 Resolved
Identified multiple DC and AC temp wiring installations in both engine rooms and the starboard lazz, properly remove and terminate all temp installations.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 18 April 2019
Resolution: All identified temp wiring installations were removed.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 March 2019 Resolved
Fuel shutoff valves must be provided at the engine end, repair or replace all missing Racor valve handles.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 18 April 2019
Resolution: All racor valve handles were provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 March 2019 Resolved
Identified the following bilge manifold stops valves did not function properly, the port cross over and crew bilge suction valves, and the starboard cross over bilge suction valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 8 May 2019
Resolution: Verified the identified valves were in a serviceable condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 March 2019 Resolved
Identified installations that are ran through both engine room hatches that prevented them from being properly secured, remove interferences.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 18 April 2019
Resolution: Verfied that all interferences were removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2019 Resolved
All cable and wire must be installed with metal supports not more than 24 inches apart, a majority of wire runs in both engine rooms and lazz'es are not properly supported.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Verified identified wiring installations were properly supported.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 18 March 2019 Resolved
Spaces must not have excessive accumulation of trash, debris or other matter that might create a fire hazard, clog bilge pumping systems or block escapes, remove excessive accumulations in both engine rooms and lazz'es
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 18 April 2019
Resolution: Excessive accumulations of storage and debris were removed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 October 2016 Resolved
Shutdown switches for both engine room fixed fire fighting systems are improperly located in the space being protected. Relocate to an acceptable location.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 5 May 2017
Resolution: Verified that all fixed fire fighting system control switches were relocated from both engine rooms to the aft void.
Construction/Loadline › Penetrations › Weld
Issued 20 September 2016 Resolved
Identified weld fracture in the port main diesel engine exhausst piping.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2016
Resolved 28 September 2016
Resolution: Exhaust penetration piping was renewed. Final weldment all sat.
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 September 2016 Resolved
Renew un-serviceable main diesel engine sea valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 13 April 2017
Resolution: Verified valve was renewed.
Unknown
Issued 20 September 2016 Resolved
The STBD #1 void was inaccessible due to excessive water. Dewater and make void available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 13 April 2017
Resolution: Void was dewatered and made available to complete ISE.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 September 2016 Resolved
Identifiied an incomplete bulkhead weld in the stbd stern void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 13 April 2017
Resolution: Verified weld was picked up.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 29 April 2016 Resolved
Provide proper number of IBAs for persons on board. 46CFR180.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 3 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 29 April 2016 Resolved
Provide fixed fire extinguishing system for paint locker. 46CFR181.400
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 3 May 2016
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 29 April 2016 Resolved
Provide proper number of child life jackets in accordance with COI. 46CFR180.71
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 3 May 2016
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 29 April 2016 Resolved
Repair oil leaking onto starboard main engine turbo housing. 46CFR182
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 3 May 2016
Operations/Management › Drills/Instruction › Abandon Ship
Issued 29 April 2016 Resolved
Conduct emergency drills with crew. 46CFR185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 3 May 2016
Personnel › Certificates/Documents/Licenses › License, Master
Issued 29 April 2016 Resolved
Provide crew licenses.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 3 May 2016
Engineering › Pressure Vessel › Relief Valve
Issued 29 April 2016 Resolved
Provide testing certs for air receiver relief valves. 46CFR182.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 3 May 2016

Casualty record · 5

6 July 2005Routine · role: Transiting Vicinity of Primary Subject · activity 2426520
13 May 2014Routine · role: Involved in a Marine Casualty · activity 4857992
26 May 2014Routine · role: Involved in a Marine Casualty · activity 4901870
30 June 2018Routine · role: Involved in a Marine Casualty · activity 6465652
4 June 2021Routine · role: Involved in a Marine Casualty · activity 7220982
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

EXECUTIVE EXPLORER (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.