Inspection history · 87
27 February 2026
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8317529
17 September 2025
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8219672
18 June 2025
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8162114
12 May 2025
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8152593
6 May 2025
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8129139
22 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8098501
4 March 2025
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8091999
4 March 2025
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8093074
3 February 2025
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8074107
29 January 2025
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8072240
21 January 2025
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8063267
23 August 2024
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7986745
26 July 2024
Damage Survey · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7974684
26 July 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7975235
7 May 2024
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7900630
27 March 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7885910
6 March 2024
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7871627
13 January 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7856347
4 January 2024
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7844331
6 November 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7820909
6 September 2023
Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7782382
27 June 2023
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7725776
16 May 2023
Deficiency Check · COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678816
2 May 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678547
9 March 2023
Internal Structural Exam · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644922
12 December 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7608368
18 October 2022
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7579120
17 May 2022
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7442154
31 March 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7449786
24 March 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417437
15 December 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7368010
22 September 2021
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7318212
16 July 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7258154
23 June 2021
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7227807
30 March 2021
Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7164809
2 December 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7103527
2 October 2020
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7071476
3 September 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7048652
18 August 2020
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7036541
24 June 2020
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6980053
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935978
24 March 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6924638
18 February 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6910444
24 January 2020
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6895462
14 January 2020
Plan Review (Other than "T")
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6888876
4 December 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6867879
7 October 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6829869
12 September 2019
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6813329
10 September 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6807725
29 April 2019
MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672441
21 March 2019
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6646710
26 February 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6632330
16 January 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6615184
4 December 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6592012
18 August 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6554151
31 July 2018
Examination of Repairs · Re-Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6497529
16 May 2018
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6408226
16 February 2018
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6359735
22 January 2018
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6341638
16 January 2018
In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6338691
16 January 2018
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6347613
20 December 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6326952
30 November 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6315661
10 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6304654
9 November 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6327005
1 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6299102
31 October 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6327870
22 September 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6297696
22 September 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6888123
22 September 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7430265
17 August 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6243678
16 May 2017
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6108242
27 April 2017
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6133902
8 February 2017
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6084848
29 January 2017
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6080533
22 November 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6045957
26 September 2016
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6024098
16 September 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6002151
2 September 2016
Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5990406
2 September 2016
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5990517
18 August 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5976390
6 May 2016
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5870350
8 March 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5829467
13 February 2016
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5823830
12 January 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5796157
10 January 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5794884
10 January 2016
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5798182
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 September 2025
Resolved
Connect hoses for fixed F/F system on CO2 bottles
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Hoses were reattached prior to the completion of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2025
Resolved
CO2 #14 needs replaced
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Corrected prior to the comoletion of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2025
Resolved
#10 Fire station hose was disconnected and valve was open
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2025
Resolved
Replace Electrical Dist Panel Cover in Space below berthing
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2025
No resolution recorded
Repare E-light in STBD Stair tower
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 17 September 2025
Resolved
Properly Mount Fire alarm pull box on pert bridge
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Corrected prior to the completion of the inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2025
No resolution recorded
Various doors not fully closing
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2025
Resolved
Tighten cover for STBD bridge Elect Dist Panel
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 September 2025
Resolved 17 September 2025
Resolution: Corrected prior to the completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2025
No resolution recorded
Vent closures on goose necks FWD Main Deck not closing or require maintenance
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2025
No resolution recorded
Repair Port and STBD doors leading to foredeck. Dogs are not working properly, and corrosion was found at both deck areas below doors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 September 2025
No resolution recorded
Replace receptical cover STBD AFT (FWD of of enginroom vents
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2025
No resolution recorded
Provide technical report from Caterpillar technician for
the required periodic safety testing procedures that are
required to be completed annually.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2025
No resolution recorded
Remove or lockout/tagout air receiver no longer in use
on the vessel. Current one has no distinction that it is
not available for use and has lapsed CG inspection.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2025
No resolution recorded
All in service inspected pressure vessels need the
maximum allowable working pressure MAWP labeled for each
pressure vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2025
No resolution recorded
re label both emergency fuel shutoff valves. Current
labeling has been worn away.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 May 2025
Resolved
Repair coupling on Fixed F/F System
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2025
Resolved 7 May 2025
Resolution: Corrected prior to the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 May 2025
Resolved
Repair or replace Port and STBD bridge wing waterlights.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2025
Resolved 7 May 2025
Resolution: Corrected prior to the end of inspection
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 6 May 2025
Resolved
Correct smoke alarm indicator on bridge to indicate proper area of alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 6 May 2025
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025
Resolved
Replace fire hose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 6 May 2025
Resolution: Corrected on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025
Resolved
Repair port IBA storage door.
Action required: 10 - Deficiency Rectified
Due 25 May 2025
Resolved 17 September 2025
Resolution: MI as far as possible, determined this requirement was corrected.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 4 March 2025
Resolved
Port vehicle bow door ram sheared off from support. Provide written plan for repairs prior to carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2025
Resolution: MI ATTENDED VESSEL AND WITNESSED SATISFACTORY REPAIR AND OPERATION OF BOW DOOR.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2025
Resolved
A "nickel sized" hole was discovered on the starboard side, in the bow thruster space above/near the waterline. Temp repair effected and vessel will proceed to Sector NY AOR for permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2025
Resolved 12 February 2025
Resolution: permanent repairs effected in Sector NY AOR.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 January 2025
Resolved
Repair or replace electrical shore tie.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 February 2025
Resolved 5 February 2025
Resolution: MI attended vessel and witnessed the replacement of cable
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 January 2025
Resolved
Prove proper operation of vent closures for bow prop space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 22 January 2025
Resolution: MI recieved proof (video) that repairs had been made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2025
Resolved
Repair leaking hose of EMG Genset
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 22 January 2025
Resolution: MI received attestment and video that hose was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2025
Resolved
Address excessive leaking of both rudder post
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2025
Resolved 5 February 2025
Resolution: Posts were adjusted.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 August 2024
Resolved
Properly mount smoke detector in boiler room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2024
Resolved 23 August 2024
Resolution: Properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2024
Resolved
Properly affix/mount ice cream cooler in galley space. 60 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 6 May 2025
Resolution: it was mounted
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 26 July 2024
Resolved
Crop and renew damaged steel in way of bow stem and ramp.
46 CFR 72.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 2 December 2024
Resolution: completed
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 26 July 2024
Resolved
Provide tech/engineers report regarding failure of Twin Disc system & ability to switch stations (main station to bridge wings). Prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2024
Resolution: Tech rep found no hard faults in the throttle system. Cause was a match setting installed when changing out new throttle heads. Issue has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 May 2024
Resolved
High water temperature and lube oil shutdowns tested at re inspection for MDE’s. Tech report from 4-24-24 only tested the alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 13 June 2024
Resolution: MI attended vessel and witnessed the correction of this item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 May 2024
Resolved
High water temperature and lube oil shutdowns tested at re inspection for SSDG’s. Tech report from 4-24-24 only tested the alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 13 June 2024
Resolution: MI attended vessel and witnessed the correction of this item.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 May 2024
Resolved
Prove proper operation of boiler room smoke alarm at helm.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 8 May 2024
Resolution: Item corrected prior to completion of inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2024
Resolved
Fixed system intended for paint locker was left installed after the conversion of the paint locker into a crew galley space. Bottle to be removed and system disabled to prevent agent from deploying into a manned space. Update needed to Safety plan.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 May 2024
Resolved 8 May 2024
Resolution: Fire service company removed bottle and disabled system, safety plan was updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2024
Resolved
STBD Main Diesel Engine Oil pump leaking Provide evidence that the pump has been repaired/replaced to stop the leak.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 21 March 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2023
Resolved
Repair oil leak on the port MDE Oil priming pump.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 8 September 2023
Resolution: O/O provided proof of repair.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2023
Resolved
Label Fire Axe located Port Side aft passenger Deck near arcade.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 13 September 2023
Resolved 6 September 2023
Resolution: Axe labeled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 September 2023
Resolved
Exit signs on passenger deck were not operating properly when tested. Repair or replace exit signs.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 8 September 2023
Resolved 8 September 2023
Resolution: Batteries were replaced and all signs are operating correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2023
Resolved
Replace relay box cover in Boiler space.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 6 September 2023
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 September 2023
Resolved
Post COI
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 6 September 2023
Resolution: Corrected on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2023
Resolved
Galley refer missing globes and cages on lighting fixtures. Install globes and cages.
Globe replaced cage on order
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 6 November 2023
Resolution: O/O provided proof of correction to this requirement.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 September 2023
Resolved
Fencing on rails around IBA's was loose at the bottom in several locations. Repair
New fencing on order
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 6 November 2023
Resolution: O/O provided proof of correction to this requirement.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2023
Resolved
Anchor light junction box needs to be mounted. Mount junction box
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 6 September 2023
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2023
Resolved
Replace 201 Adult Type 1 Life Jackets. Vessel is limited to 780 total persons until life jackets are replaced.
Total persons allowed may be increased as Jackets are added.
Action required: 705 - Other - as specified
Due 16 May 2023
Resolved 7 June 2023
Resolution: Vessel had added 201 Life Jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2023
Resolved
Provide proof of fire hoses meeting UL listing or replace hoses.
New Hoses are ordered. Vessel may leave unrated hoses on board until proper hoses are provided if an equivalent level of safety is met by placing two additional unrated hoses onboard as spares.
Action required: 705 - Other - as specified
Due 16 May 2023
Resolved 6 November 2023
Resolution: O/O provided proof of correction to this requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 16 May 2023
Resolved
Replace or repair Port Embarkation Lighting.
Action required: 705 - Other - as specified
Due 16 May 2023
Resolved 17 May 2023
Resolution: Fixture was replaced.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 May 2023
Resolved
Repair or replace smoke detector located in boiler room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2023
Resolved 17 May 2023
Resolution: detector was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2023
Resolved
Item issued by Sector LIS MI during machinery inspection.
Prove proper operation of MDE overspeed trips in the presence of a MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 September 2023
Resolution: Completed to the satisfaction of the MI
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 16 May 2023
Resolved
Item issued by Sector LIS MI during machinery inspection.
Locate and eliminate ground identified on the emergency switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 17 May 2023
Resolution: Ground was found and removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2022
Resolved
Install permanent bilge pump in way of branch line for dirty oil suction in engine room. (at next drydock)
Action required: 705 - Other - as specified
Resolved 16 May 2023
Resolution: completed at dry dock
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 October 2022
Resolved
Prove proper operation of the fire screen door leading to galley space on port side main passenger cabin. (at dry dock)
Action required: 705 - Other - as specified
Resolved 16 May 2023
Resolution: completed during dry dock
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 18 October 2022
Resolved
Wasted steel and damaged box in way of elevator platform on car deck poses passenger/crew safety hazard. Eliminate hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2022
Resolved 16 May 2023
Resolution: completed during dry dock
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022
Resolved
Complete boiler testing at first quarterly inspection.
Action required: 705 - Other - as specified
Due 1 January 2024
Resolved 7 May 2024
Resolution: Serviced in October, 2023.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2022
Resolved
Replace cracked light covers throughout car deck area. Ensure emergency lighting is properly labeled.
835 extended due to the covers needing to be special ordered.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 18 October 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 May 2022
Resolved
Place fire stop material in thru hulls in boiler room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 7 June 2022
Resolution: Fire stop material installed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 May 2022
Resolved
Replace port side bridge wing gauge cover. Cannot see gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 7 June 2022
Resolution: New cover installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 May 2022
Resolved
Repair hole in engine room bulkhead starboard side near entrance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2022
Resolved 7 June 2022
Resolution: Bottom of E/R access blkd doubled as a temp. repair until next DD.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 May 2022
Resolved
Transfer of emergency load must be accomplished w/in 45 seconds. Emergency generator did not start.
Action required: 10 - Deficiency Rectified
Resolved 17 May 2022
Resolution: This was tested satisfactory
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 22 September 2021
Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. In stbd sid main cabin by servers, junction box is hanging down/connected. Secure for pax/crew protection. 46 CFR 70.25-1--> 46 CFR 111.81-1(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2021
Resolution: attached securely
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 September 2021
Resolved
All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of emergency shall be conspicuously marked with letters at least 1" high identifying the control and the direction of operation. Bilge/ballast system labels found to be faded or non-existant. Label system valves and tag out ballast system (not in operationg). 46 CFR 78.47-38(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2021
Resolution: labeled
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 July 2021
Resolved
Structural Fire Protection Plan was not updated when an A-60 boundary was added to the overhead of the bow thruster space. Vessel management is to submit an updated Structural Fire Protection Plan and cut sheets for the materials used in creating the bow thruster A-60 boundary to MSC for approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 1 September 2021
Resolution: Received MSC approval letter
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 June 2021
Resolved
Emergency lights in passenger cabin stbd side do not work under emergency power. Prove proper operation of embergency lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 25 August 2021
Resolution: Lights were wired incorrectly and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2021
Resolved
During de-watering testing of voids it was noted that water was able to bypass the check valve in void #4. Repair or replace check valve in void #4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 25 August 2021
Resolution: New check valve was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2021
Resolved
Replace broken stuffing tube on upper deck stbd side embarkation light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 25 August 2021
Resolution: New stuffing tube installed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 March 2021
Resolved
Vital systems that are automatically or remotely controlled must be provided with an alarm system for detection of a failure or unsafe condition. The vessels electronic propulsion controls for the main engines was found operating in an alarm condition. When C/E was questioned about the alarm and he stated that it was a voltage issue with the system. The C/E did not have the manual available onboard to read the alarm code. C/E also stated that the alarm has been intermittent for two weeks. Vessel was able to restart the engines and clear the alarm. Manufactures representative was contacted and he stated the caterpillar engine interface with the twin disc controls causes the alarm when there is an error in the caterpillar engine. Vessel to conduct sea trial to verify if the alarm returns. Vessel not to sail with propulsion controls in alarm condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2021
Resolved 30 March 2021
Resolution: Vessel completed 1.5 hour sea trial with no alarms. Vessel allowed to return to service.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 March 2021
Resolved
Fire screen doors shall have a latch arrangement that is automatically engaged when by the operation of the door. 03 Fire screen doors will not latch due to the door hitting the frame prior to engaging the latch. The doors are located in the following locations. Galley to passenger cabin, car deck to upper deck stbd side, and upper deck to passenger cabin stbd side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 16 April 2021
Resolution: Recieved video via email of the fire door closing properly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2020
Resolved
Provide a sign on the bow thruster room door stating that the space is protected by CO2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 18 August 2020
Resolution: Received e-mail confirmation
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 June 2020
Resolved
Provide emergency light in stbd aft stairwell leading to car deck. Light was removed at shipyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 18 August 2020
Resolution: Recieved e-mail confirmation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020
Resolved
Mark all emergency lights missing the E marking
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 18 August 2020
Resolution: Received e-mail confirmation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020
Resolved
Re-secure main electrical cable from generators to electrical panel and add chafing gear to prevent further damage to wire casing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 18 August 2020
Resolution: Received e-mail confiramtion
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 June 2020
Resolved
Repairs were made to the sprinkler system piping stbd side aft on the overhead of the freight deck. Vessel reps unable to test piping at this time. Test sprinkler system piping in area of repairs prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 24 June 2020
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 February 2020
Resolved
Prove proper operation of fire pump gauge on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 1 September 2020
Resolution: Pressure gauge installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 February 2020
Resolved
Terminate lighting cable for light fixture in steering space in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 24 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 February 2020
Resolved
Terminate jacket water alarm cable for the emergency generator in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2020
Resolved 24 June 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 December 2019
Resolved
02 emergency lights were found to be not working.
Action required: 10 - Deficiency Rectified
Due 4 December 2019
Resolved 4 December 2019
Resolution: The batteries were replaced and cleared on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 September 2019
Resolved
De-scale and de-water #4 void. Vessel crew is required to inspect #4 void at least twice a day for the presence of water. If any water is observed it shall be reported to Sector Long Island Sound.
Action required: 705 - Other - as specified
Due 25 September 2019
Resolved 15 October 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2019
Resolved
Fixed fire extinguishing systems could not be tested and serviced on day of inspection. Sea Safety will conduct all testing and servicing of portable and fixed extinguishing systems in the presence of a marine inspector on 16May19.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 16 May 2019
Resolution: USCG marine inspectors attended the vessel and witnessed fixed fire fighting system testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2019
Resolved
Replace stuffing tubes in deck iwo hydraulic power panel and stbd side upper car deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 16 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2019
Resolved
Prove propper operation of aft lower mast light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 15 May 2019
Resolution: Recieved photo from vessel master showing the lower mast light operational.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 April 2019
Resolved
Replace broken light covers on fixtures located stbd side main deck aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 11 July 2019
Resolution: Broken covers replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 April 2019
Resolved
Repair broken e-light located port side stairwell between 01-02 decks
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 11 July 2019
Resolution: Emergency lights repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2019
Resolved
Repair e-light located in the engine room port side iwo engine alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 11 July 2019
Resolution: Emergency lights repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2019
Resolved
Update periodic safety test procedures to include over speed shutdowns for the #1 and #2 generators as well as both main engines.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 8 May 2024
Resolution: Item was added to the PSTP
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2019
Resolved
Prove proper operation of e-gen low lube oil and high jacket water alarms on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 11 July 2019
Resolution: Alarms operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2019
Resolved
Repair high jacket water sensor and prove proper operation of on the #2 generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2019
Resolved 11 July 2019
Resolution: High jacket water alarm operational.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 4 December 2018
Resolved
Galley sanitation found to be unsatisfactory. The removable grease vents over the deep fat fryer and griddle were found with excessive grease and dirt creating an increased asked risk of fire. The galley floor was found with excessive amounts of dirt and grime throughout especially in corners and under equipment. Temperature sensitive food was also found left out for extended periods of time creating a health risk to passengers. Vessel management to ensure galley is satisfactorily cleaned and food safety measures are followed. Vessel management to provide a written fleet wide corrective action plan to the Coast Guard to
preventfuture incidents. Future occurrences could lead to food service suspension.
Action required: 705 - Other - as specified
Due 25 January 2019
Resolved 6 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2018
Resolved
Update vessel periodic testing sheets to include boiler and CO2 testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2019
Resolved 6 March 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 December 2018
Resolved
The search light control arm leaks water. The water leaks into the pilot house through the control arm and power switch. This condition poses an electrical safety risk. Make top of pilot house and search light watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2019
Resolved 6 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 August 2018
Resolved
Compliance with the standards established by the American Bureau of Shipping, will be considered satisfactory evidence of the structural efficiency of the vessel. While conducting first quarter re-inspection the fuel tank void was found flooded with approximatly 4 feet of water. Crew was directed to de-water the space and make ready for inspection. After the space and make ready for inspction. After the space was dewated, a close up internal inspection found a three inch transverse crack running under the fourth longitudinal frame. Make permanent repairs to the crack t the satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2018
Resolved 28 August 2018
Resolution: Satisfactory repairs via insert was carried out and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 August 2018
Resolved
Vessel shall be incompliance with their COI at all times. Vessel has removed 2-25 person IBA's for servicing. Vessels total persons permitted reduced to 906.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 29 August 2018
Resolution: IBA's were serviced and re-installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2018
Resolved
Double doors capable of independent operation and latching may have a clearance between the doors not exceed 1/8 inch. Self closing automatic fire door did not latch. Prove proper operation of fire door closing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2018
Resolved 4 September 2018
Resolution: Recieved email video of fire screen doors closing properly.
Engineering › Bilge Water Management System › Valve
Issued 16 May 2018
Resolved
Repair check valve in void #4. Check valve is stuck in the open position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 May 2018
Resolved
Repair emergency light port side aft on car deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 16 May 2019
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 May 2018
Resolved
Provide placard for life jacket locker, starboard side forward on the sun deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 30 May 2018
Resolution: Placard installed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 May 2018
Resolved
Repair latch on the deli vent damper, starboard side on the sun deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Communications › Audible Communications › Bell
Issued 16 May 2018
Resolved
Label general alarm, port side aft car deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Construction/Loadline › Structures › Door
Issued 16 May 2018
Resolved
Free up dogs on paint locker door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 14 June 2018
Resolution: Dogs replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 16 May 2018
Resolved
Clean grease build up on galley hood.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 30 May 2018
Resolution: Galley hood cleaned.
Fire Fighting › Grease Extraction Hood › General
Issued 16 May 2018
Resolved
Conduct annual maintenance of galley hood fire system. To be completed prior to operation of the griddle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 30 May 2018
Resolution: Annual maintenance conducted.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 16 May 2018
Resolved
Repair rudder angle indicator located at the engine room operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 16 May 2018
Resolved
Repair/replace all failed sensors as per the automation periodic test procedure check off sheet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2018
Resolved
Provide cover for junction box next to port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2018
Resolved
Remove dead end wireing from behind blower on aft engine room bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 13 July 2018
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 16 May 2018
Resolved
Demonstrate proper operation of car deck sprinkler system under the port fwd ramp.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 30 May 2018
Resolution: System repaired and tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 16 May 2018
Resolved
Obtain 13 adult life jackets
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2018
Resolved 31 May 2018
Resolution: 13 PFDs provided.
Engineering › Bilge Water Management System › Piping
Issued 6 April 2018
Resolved
Test Bilge suction in All spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2018
Resolution: Bilge suctions tested.
Construction/Loadline › Hull › Bottom Plating
Issued 22 January 2018
Resolved
Repair hole in the bottom plate located under the stbd engine room stair well.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2018
Construction/Loadline › Hull › Hull Plating
Issued 16 January 2018
Resolved
Conduct permanent reapirs to the satisfaction of the attending Marine Inspector prior to carriage of passengers, vessel reported to be holed, 3/8in. diameter located at the chine, starboard side machinery space
Due 16 January 2018
Resolved 16 May 2019
Communications › Visual Communication › Red Warning Signal
Issued 30 November 2017
Resolved
Label do not park emergency fuel shut off on car deck and MSD escape hatch.
Condition: Improper Installation
Due 7 December 2017
Resolved 17 May 2018
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 November 2017
Resolved
Install cover on electrical outlet in galley.
Condition: Improper Installation
Due 7 December 2017
Resolved 17 May 2018
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 30 November 2017
Resolved
Perform load analysis of electrical panal #2 in snack bar galley.
Condition: Design Flaw
Due 7 December 2017
Resolved 17 May 2018
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 30 November 2017
Resolved
Move the cord so is not running over counter by sink. (food warmer)
Due 7 December 2017
Resolved 17 May 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 10 November 2017
Resolved
Pipe backed out causing a dishcharge of CO2 into the car deck. Vsl is to have servicing tech provide report of failure and proper operation of system and to check all fire fighting systems on board the vsl. The vsl is to maintain a live fire watch in the space with extinguishers and 2way communication while operating the vessel. Once the def is cleared and requirements are met the vsl may opererate without the live fire watch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 14 November 2017
Resolution: Privded Tech report from servicing company.
Engineering › Steering Gear System › Cable
Issued 1 November 2017
Resolved
PARK CITY had a loss of steering or a loss of control to the steering from the bridge, but was able to control steering from the pilot wing and emergency steering in the engine room. Engineering noticed loose cables and sodered them and this appreared to fix the problem. While USCG marine inspector was onboard pump #2 was not communicating from bridfe control, MI noticed a fuse was blown, engineers replaced fuse and steering system was fully functional and def was cleared.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 November 2017
Resolved 1 November 2017
Resolution: While USCG marine inspector was onboard pump #2 was not communicating from bridfe control, MI noticed a fuse was blown, engineers replaced fuse and steering system was fully functional and def was cleared.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 May 2017
Resolved
Repair hydraulic leaks at visor control deck fittings
Due 16 June 2017
Resolved 17 August 2017
Resolution: Leak repaired.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 16 May 2017
Resolved
Provided bracket for e/r Halon System pull cable conduit at bottle release
Due 16 June 2017
Resolved 17 August 2017
Resolution: Bracket installed.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 16 May 2017
Resolved
Repair port wiper on pilot house window
Due 16 June 2017
Resolved 19 May 2017
Resolution: Wiper repaired
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 16 May 2017
Resolved
Repair low lube oil sensor for alarm and shut down of the #1 SSG
Due 16 June 2017
Resolved 17 August 2017
Resolution: Sensor repaired.
Construction/Loadline › Penetrations › Weld
Issued 16 May 2017
Resolved
Repair fractured support bracket for the port rudder tube.
Due 16 June 2017
Resolved 17 August 2017
Resolution: bracket repaired.
Construction/Loadline › Structures › Deck Plating
Issued 16 May 2017
Resolved
Replace port rudder stop
Due 16 June 2017
Resolved 17 August 2017
Resolution: Rudder stop replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 May 2017
Resolved
Repair excursion netting fence on port side of sun deck
Due 16 June 2017
Resolved 19 May 2017
Resolution: Fence repaired.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 8 February 2017
Resolved
Detection fault in bow thruster space was alarming on fire panel located in the wheel house.
Due 8 March 2017
Resolved 27 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 8 February 2017
Resolved
Hydraulic line on top of the STBD reduction gear was leaking.
Due 8 March 2017
Resolved 27 April 2017
Engineering › Reduction Gearing/Clutches › Shaft
Issued 8 February 2017
Resolved
Shaft tachs need to be adjusted. Shaft tachs were not indicating zero when shafts were at all stops.
Due 8 March 2017
Resolved 27 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 8 February 2017
Resolved
Starboard main had an exhaust leak located on the top aft of the engine.
Due 8 March 2017
Resolved 27 April 2017
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 8 February 2017
Resolved
Add bow thruster fire detection system to vessel's automation procedures.
Due 8 March 2017
Resolved 27 April 2017
Accommodation/Occupational Safety › Potable Water System › General
Issued 19 May 2016
Resolved
Replace water filters in galley and fire control valve space.
Condition: Improper/Lack of Maintenance
Due 19 May 2016
Resolved 23 May 2016
Resolution: filters replaced.
Communications › Visual Communication › Warning Sign (gangway)
Issued 19 May 2016
Resolved
Label emergency exit in the MSD space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 18 August 2016
Resolution: Hatch labeled.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 May 2016
Resolved
Hole in transome 6 inches from the center line just below the ramp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 22 November 2016
Communications › Alarms/Indicators › General Alarm
Issued 19 May 2016
Resolved
Update ships alarm test procedures check sheet, include updated alarm
Due 17 June 2016
Resolved 15 September 2016
Engineering › Thrusters › Motor
Issued 19 May 2016
Resolved
Demonstrate operational readyness FOP alarm. Bow Thruster motor.
Due 17 June 2016
Resolved 15 September 2016
Electrical › Electric Generation Source (service) › Switch
Issued 19 May 2016
Resolved
Install and demostrate OPSR readeness of load sharing for SSG.
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 22 May 2017
Resolution: Next Dry Dock
Electrical › Electric Generation Source (service) › Switch
Issued 19 May 2016
Resolved
Demostrate OPSR readiness High Temp alarm for SSDG.
Due 19 June 2016
Resolved 17 August 2016
Resolution: Rectified
Engineering › Steering Gear System › Pump
Issued 19 May 2016
Resolved
Demostrate OPSR readiness for low oil HYDR Steering gear pumps. 1 and 2
Condition: Improper/Lack of Maintenance
Due 17 June 2016
Resolved 16 September 2016
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 19 May 2016
Resolved
Repair pressure sensor. Boiler room.
Condition: Invalid
Due 30 September 2016
Resolved 22 November 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 19 May 2016
Resolved
Demonstrate OPSR readiness of #10 PMDE PYRO Meter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 August 2016
Resolution: Rectified
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 19 May 2016
Resolved
Update ships alarm test procedures check sheet.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 15 September 2016
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 May 2016
Resolved
Repair /replace crew phone in crew room.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 18 August 2016
Resolution: Phone repaired and tested.
Engineering › Generator (propulsion/auxiliary-electric) › Fuse (overload/over current protection)
Issued 6 May 2016
Resolved
Overspeed test SSG 1 and 2
Due 17 June 2016
Resolved 15 September 2016
Construction/Loadline › Structures › Scuttle
Issued 8 March 2016
Resolved
Replace upper clip and eye bolt on forepeak access.
Due 3 April 2016
Resolved 18 August 2016
Resolution: Bolt replaced.
Construction/Loadline › Structures › Door
Issued 8 March 2016
Resolved
Repair PS FSD #4 door frame in lounge
Due 3 April 2016
Resolved 16 September 2016
Construction/Loadline › Structures › Door
Issued 8 March 2016
Resolved
Adjust stbd door that leads from the passenger cabin to the car deck
Due 3 April 2016
Resolved 18 August 2016
Resolution: Door adjusted.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 8 March 2016
Resolved
Track down and fix ground detected on e-generator main panel
Due 3 April 2016
Resolved 17 August 2016
Resolution: Rectified
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 March 2016
Resolved
Replace light bulbs on the stbd side E-lights
Due 3 April 2016
Resolved 18 August 2016
Resolution: Light bulbs replaced.
Fire Fighting › Fire Pumps › Arrangement
Issued 8 March 2016
Resolved
Install pressure relief valves on outlet side of both fire pumps
Action required: 705 - Other - as specified
Resolved 17 May 2018
Resolution: Due at next dry dock
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 10 January 2016
Resolved
Make permanent repair to distribution panel on stbd side galley for walk in refer boxes and A/C units. (had electrical fire, also provide electricians report)
Action required: 705 - Other - as specified
Due 25 January 2016
Resolved 14 January 2016
Resolution: electricians report provided, entire panel replaced