Records from 1986 to 2011. Most recent: inspection, 8 December 2011.
Inspection history · 22
8 December 2011
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 4204475
8 February 2011
Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3934515
13 November 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1947082
22 February 1999
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 426614
23 August 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 419484
4 February 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 412506
2 February 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 412128
24 April 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 402665
11 February 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 400218
19 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 395537
2 August 1996
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 393287
23 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 391417
6 November 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 383665
26 June 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 379534
27 January 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 155101
26 October 1994
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 371739
11 November 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 54252
12 July 1993
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 359491
8 May 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 484735
26 September 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339479
22 June 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331085
15 August 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 311293
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 February 2011
Resolved
Hold back hooks are installed in stairwell and galley class A doors.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 21 March 2011
Resolution: Hooks removed by captain before class came on board.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 February 2011
Resolved
Light covers throughout accomodation spaces missing and need replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 8 December 2011
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 February 2011
Resolved
Oil containment throughout ship have wooden plugs and are missing the mechanical means for closure/drainage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 21 March 2011
Resolution: Mechanical closures are now provided for containment on vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 February 2011
Resolved
Oil content meter is inoperable. Vessel permitted to depart port to receive ordered parts at next port.
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 21 March 2011
Resolution: oil content meter now in working order.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 February 2011
Resolved
Unable to test high water alarm due to bilge level of oily water and OWS not operating properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2011
Resolved 1 March 2011
Resolution: Bilge was emptied by SOLAR Inc and bilge alarm was able to be tested.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 February 2011
Resolved
Temporary repairs to salt water piping end cap needs replaced.
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 13 May 2011
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 8 February 2011
Resolved
Make proper repairs to MSD Type II tank.
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 13 May 2011
Fire Fighting › Means of Escape › Doorways
Issued 8 February 2011
Resolved
Escape hatch in steering gear room unable to open.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 13 May 2011
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 8 February 2011
Resolved
Re[place activating valve in paint locker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 21 March 2011
Resolution: Valve replaced.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 8 February 2011
Resolved
Ensure all EEBDs are in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 21 March 2011
Resolution: EEBDs in serviceable condition.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 8 February 2011
Resolved
Replace A-II extinguisher at paint locker with B-II extinguisher.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 1 March 2011
Resolution: Fire extinguisher replaced.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 February 2011
Resolved
Bilge is full of oily water and OWS is not in proper working condition. Discharge oily bilge water at facility.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2011
Resolved 1 March 2011
Resolution: Bilge water removed by Solar Inc. for disposal.
Lifesaving
Issued 2 February 1998
Resolved
INOPERATIVE LIFEBOAT MOTOR, STARBOARD BOAT.
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Accommodation/Occupational Safety
Issued 11 February 1997
Resolved
AUTO CLOSURE DEVICE ON ENGINEROOM ENTRANCE DOOR NOT OPERATIONAL.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Accommodation/Occupational Safety
Issued 11 February 1997
Resolved
REPAIR OR RENEW WASTED FRAMES TO 5 HOUSE WEATHERTIGHT EXIT DOORS.
Condition: Unknown
Due 26 April 1997
Resolved 26 April 1997
Fire Fighting
Issued 2 August 1996
Resolved
HAVING INSPECTED VARIOUS FIRE HOSE BOXES ON DECK, NONE FOUND TO HAVE SPANNER WRENCHES. VSL REQUIRED TO CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Construction/Loadline
Issued 23 May 1996
Resolved
REPAIR CRACKS IN PORT AND STARBOARD SIDE SHELL IN WAY OF FRAME 44 FREEING PORTS. REPAIRS ARE TO BE MADE PRIOR TO RETURNING TO THE NEXT U.S. PORT ANDTO THE SATISFACTION OF NKK.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Documentation
Issued 26 June 1995
Resolved
OIL TRANSFER PROCEDURES WAS INADEQUATE. ISSUED [name withheld] OF BILINGUAL OIL TRANSFER PROCEDURES TO ADD NECCESARY INFORMATION TO EXISTING PROCEDURES.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Fire Fighting
Issued 26 June 1995
Resolved
FIRE HOSE ON PORT SIDE WEATHER DECK LOCATED AMIDSHIP WORN BEYOND REPAIR. REPLACED ON SPOT DURING BOARDING.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Fire Fighting
Issued 26 October 1994
Resolved
WHILE CONDUCTING A FOREIGN FREIGHT VESSEL EXAMINATION, INSPECTORS ASKED TO HAVE THE EMERGENCY FIRE PUMP ENERGIZED. VSL PERSONNEL COULD NOT GET PUMP STARTED. AFTER TROUBLE SHOOTING THE FIRE PUMP VSL. PERSONNEL WHERE ABLE TO START THE EMERGENCY FIRE PUMP. REASON FOR PROBLEM IS UNKNOWN.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Accommodation/Occupational Safety
Issued 26 October 1994
Resolved
WHILE CONDUCTING AN FOREIGN FREIGHT VESSEL EXAMINATION ON BOARD THE M/V AKAMA, COAST GUARD INSPECTOR OBSERVED THE VALVE FROM THE MSD, TO THE OVER BOARD DISCHARGE IN THE OPEN POSITION. VSL PERSONNEL CLOSED THE VALVE AT THIS TIME.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Documentation
Issued 12 July 1993
Resolved
LIST OF PRODUCTS TRANSFERED NOT LISTED ON THE BUNKERING PROCEDURES FOR THE VESSEL.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Navigation
Issued 22 June 1989
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT VOL.3 USED BY THE VSL WAS NOT CORRECTED TO NTM 03/89 WHICH WAS REASONABLY AVAILABLE & CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN DE. TO WILMINGTON DE. NO FOREIGN EQUIVALENT O/B.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Engineering
Issued 15 August 1986
Resolved
VESSEL WAS OVER 400GT DID NOT HAVE A STANDARD DISCHARGE CONNECTION A VIOLATION OF 33 CFR 155.430(A)
Condition: Unknown
Due 15 August 1986
Resolved 15 August 1986
Navigation
Issued 15 August 1986
Resolved
VESSEL DID HAVE U.S. COAST GUARD LIGHT LIST OR AN EQUIVAIANT FOREIGN PUB. A VIOLATION OF 33 CFR 164. 33(A)(2)(II)
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993