This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 20 June 2018
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1994–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA3418
Flag
UNITED STATES
Tonnage
30 - Regulatory (Subpart C or D), Gross Ton 20 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-72620
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 50

20 June 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6443392
17 May 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6416880
10 July 2017 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6247836
8 February 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6085014
24 October 2016 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6028750
16 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860576
11 May 2016 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860574
10 June 2015 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5130571
12 May 2014 Hull Examination · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4884137
5 March 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4810680
21 June 2013 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4613306
24 May 2012 Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4321764
13 December 2011 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4207620
14 September 2011 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4145229
4 August 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4112313
26 May 2010 Internal Structural Exam · Deficiency Check · Drydock Exam · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3743969
24 August 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3593988
29 May 2008 Annual Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3226518
9 October 2007 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3086951
24 May 2006 Internal Structural Exam · Hull Examination · MARPOL Annex V Examination · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2696688
30 August 2005 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2479799
1 July 2005 COI Inspection · MTSA Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2328836
18 May 2004 Hull Examination · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2078267
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958092
17 October 2003 Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1930863
7 August 2003 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1880340
22 July 2002 Hull Examination · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1650482
11 September 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1073511
1 March 2001 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1058130
13 October 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1053826
5 August 2000 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373137
17 March 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1048550
26 January 2000 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 153209
3 September 1999 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1381726
6 August 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 37048
19 February 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 40670
30 October 1998 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1436134
23 September 1998 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 799769
28 August 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 797404
1 August 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1364820
22 July 1998 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 796291
5 August 1997 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1400612
14 October 1996 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1153408
29 July 1996 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1086510
23 April 1996 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 117542
15 June 1995 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 878808
25 April 1995 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1358719
24 April 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 120874
27 January 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 155101
16 August 1994 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1171491

Deficiency record · 122

Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2016 Resolved
Provide updated charts
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Proof provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2016 Resolved
Provide first aid kit IAW 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Proof provided.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 16 May 2016 Resolved
Provide proof that life raft is installed correctly. Vessel is restricted to river route until life raft is installed
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 25 May 2016
Resolution: Proof provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 25 August 2014 Resolved
Provide documentation of employee coverage in DAPI program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O provided proof of employee coverage in DAPI program.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 August 2014 Resolved
Provide Alcohol testing strips for entire crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2014
Resolution: O/O provided proof of alcohol testing strips for the entire crew.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2014 Resolved
Insert hull plating iwo doubler plate on stbd side of bow in line with the lifting eye. Minimum insert to be 18" x 18"
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2014
Resolved 24 October 2016
Resolution: O/O provided picture of new insert.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2014 Resolved
Insert hull plating iwo doubler plate above port propeller. Minimum insert to be 18" x 18".
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O provided picture of new insert.
Construction/Loadline › Hull › Bottom Plating
Issued 12 May 2014 Resolved
Insert hull plating iwo doubler plate on port side of the keel where the skeg connects. Minimum insert to be 18" x18".
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O provided picture of new insert.
Engineering › Bilge Water Management System › Piping
Issued 12 May 2014 Resolved
Crop and renew wasted bilge line at aft engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O renewed wasted bilge line.
Construction/Loadline › Structures › Deck Plating
Issued 12 May 2014 Resolved
Provide repair proposal for wasted tank top in generator space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O provided picture of new insert.
Stability › Watertight Integrity › General
Issued 12 May 2014 Resolved
Crop and renew wasted watertight door to generator space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O replaced watertight door to generator space.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 May 2014 Resolved
Crop and renew wasted section of forward engine room bulkhead at keel (splash zone repair).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O provided picture of new insert.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 12 May 2014 Resolved
Provide and maintain a gas free certificate for the abandoned potable water tank under the generator room (Marine Chemist Cert). Make space available for inspection by USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: O/O made space available for USCG inspection.
Engineering › Bilge Water Management System › Piping
Issued 12 May 2014 Resolved
Provide metallic piping for bilge system in engine room and remove PVC filtration system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O replaced PVC bilge piping with metallic piping.
Fire Fighting › Fire Main › Condition
Issued 12 May 2014 Resolved
Renew rubber hose connection for fire main sea suction outboard of the starboard MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: O/O renewed hose connection for sea suction on STBD MDE.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 May 2014 Resolved
Provide valid FCC Safety Radiotelephony Certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 15 October 2014
Resolution: O/O provided proof of valid certificate
Fire Fighting › Nozzles › Approval
Issued 21 June 2013 Resolved
Provide proper nozzle for fire hose.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 19 July 2013
Resolution: O/O provided proof of proper nozzle for fire hose.
Engineering › Bilge Water Management System › Strainer
Issued 21 June 2013 Resolved
Renew strainer for bilge line in galley.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 19 July 2013
Resolution: O/O provided new strainer for bilge line in galley.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 June 2013 Resolved
Provide valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 19 July 2013
Resolution: O/O provided valid FCC Safety Radiotelephony Certificate .
Engineering › Bilge Water Management System › Valve
Issued 21 June 2013 Resolved
Replace check valve on bilge manifold.
Action required: 705 - Other - as specified
Due 21 June 2013
Resolved 21 June 2013
Resolution: O/O replaced check valve and proved proper operation of bilge suction.
Stability › Weathertight Integrity › General
Issued 21 June 2013 Resolved
Replace hinge on STBD weather tight door leading to wheel house.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 19 July 2013
Resolution: O/O replaced hinge on STBD weather tight door leading to wheel house.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 June 2013 Resolved
Replace battery with approved battery in water light.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 19 July 2013
Resolution: O/O replaced water light battery with an approved battery.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 May 2012 Resolved
Plug hole in e/r bulkhead aft
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Received email from vsl rep showing completion of repairs.
Fire Fighting › Fire Main › Condition
Issued 24 May 2012 Resolved
reweld bracket on fire main suction pipe in the e/r
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Electrical › Electrical Distribution System (service) › Cable
Issued 24 May 2012 Resolved
Hardwire electric bilge pump in the e/r and remove orange electrical extension cord.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 May 2012 Resolved
Provide proof of servicing of CO2 system
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Firefighting equipment servicing certificate was emailed to CG
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 May 2012 Resolved
Properly label lifejacket storage location
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 May 2012 Resolved
Properly separate child size lifejacketts from adult sized.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 May 2012 Resolved
Double entry
Due 25 May 2012
Resolved 25 May 2012
Resolution: Already entered. Double entry entered in error.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2012 Resolved
Provide proper cover for e/r ligth fixture on stbd side of engine
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2012 Resolved
Remove uncovered halogen light fixtures from e/r
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG. Lights removed and plugged.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 May 2012 Resolved
Secure electrical junction box at the e/r door
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Engineering › Fuel Oil Service System › Vent Pipe
Issued 24 May 2012 Resolved
Provide serviceable screen for fuel vent
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 May 2012 Resolved
Move junction box for stern light and replace cover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 24 May 2012 Resolved
Provide proper vracket for stateroom fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new bracket installed was emailed to CG
Lifesaving › Inflatable Liferafts › Not on Board
Issued 24 May 2012 Resolved
Provide serviceable liferaft to accommodate all persons aboard prior to operating with passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Received email photo from vsl rep showing installed liferaft.
Construction/Loadline › Structures › Superstructure
Issued 24 May 2012 Resolved
Plug bulkhead penetration in generator room in way of door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2012
Resolved 5 June 2012
Resolution: Photo of new installation was emailed to CG
Documentation › Certificates/Documents › FCC SSL
Issued 4 August 2011 Resolved
Provide valid FCC station license.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 August 2011
Resolution: License provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 August 2011 Resolved
Provide proof of enrollment in drug testing program for crew.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 October 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 August 2011 Resolved
Provide 1 type I child life preserver.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 August 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 August 2011 Resolved
Replace expired products in first aid kit.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 August 2011
Stability › Unintentional Flooding › General
Issued 4 August 2011 Resolved
Provide permanent means to seal forward engine room bulkehads abandoned hose penetrations.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 14 September 2011
Fire Fighting › Fire Pumps › Suction Valve
Issued 4 August 2011 Resolved
Renew suction hose for fire monitor pump.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 October 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 August 2011 Resolved
Provide servicing certificate for E/R CO2 fire extinguisher and generator CO2 extinguisher.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 14 September 2011
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 4 August 2011 Resolved
Repair coolant leak on port MDE keel cooler.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 11 August 2011
Engineering › Lubricating Oil Service System › Cooler
Issued 4 August 2011 Resolved
Repair leaking oil cooler on stbd MDE.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 14 September 2011
Fire Fighting › Structural - Main Vertical Zones › General
Issued 4 August 2011 Resolved
Provide vapor tight seal for aft generator room bulkhead.
Action required: 705 - Other - as specified
Due 4 September 2011
Resolved 14 September 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 June 2010 Resolved
Install chain or other suitable material across narrow passageway just forward of wheelhouse door and at aft end of superstructure, port & stbd sides, with an attached sign indicating, "No Passengers Beyond this Point."
Due 15 July 2010
Resolved 9 July 2010
Resolution: Rcvd e-mail photos indicating placement of signage.
Engineering › Bilge Water Management System › Not Operational
Issued 26 May 2010 Resolved
Prover proper operation of fixed bilge system.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 May 2010 Resolved
Provide servicing report for fixed CO2 system (prior to operating).
Due 27 May 2010
Resolved 15 June 2010
Resolution: Rcvd e-mailed servicing rpt.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 May 2010 Resolved
Provide servicing report for hand portable fire extinguishers (prior to operating).
Due 27 May 2010
Resolved 9 June 2010
Resolution: Rcvd e-mail photos of current inspection tags.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 26 May 2010 Resolved
Properly install 20 person capacity liferaft (to include hydrostatic release unit)(prior to operating).
Due 27 May 2010
Resolved 9 June 2010
Resolution: Rcvd e-mail photo.
Engineering › Bilge Water Management System › Valve
Issued 26 May 2010 Resolved
Renew valve handle for bilge line that services galley.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Engineering › Fuel Oil Service System › Hose
Issued 26 May 2010 Resolved
Replace flexible fuel hoses on generator w/ SAE J1942 or USCG type A1, A2, B1 or B2 hose. Ensure proper fittings in accordance with manufacturers instructions.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 26 May 2010 Resolved
Place properly serviced hand portable fire extinguishers aboard vessel (prior to operating).
Due 27 May 2010
Resolved 9 June 2010
Resolution: Rcvd e-mail photos.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 May 2010 Resolved
Properly terminate dead-ended wire at forward bulkhead of lazarette.
Due 27 June 2010
Resolved 28 June 2010
Resolution: Rcvd e-mail photo indicating completion.
Engineering › Bilge Water Management System › Not Operational
Issued 26 May 2010 Resolved
Remove all liquids from bilge.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 May 2010 Resolved
Prove proper operation of engine room bilge high water alarm.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 May 2010 Resolved
Replace EPIRB's expired hydrostatic release unit (prior to operating).
Due 27 May 2010
Resolved 9 June 2010
Resolution: Rcvd e-mail photos.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 May 2010 Resolved
Remove drop chord receptical just aft of wheelhouse on weather deck.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Stability › Weathertight Integrity › General
Issued 26 May 2010 Resolved
Make penetration from #12 weathertight.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Engineering › Fuel Oil Service System › Piping
Issued 26 May 2010 Resolved
Secure loose fuel piping to generator.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 26 May 2010 Resolved
Install double hose clamps to the aft non-metallic hose connections to port & stbd keel cooler.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 May 2010 Resolved
Make forward engine room bulkhead penetrations at bilge watertight.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Stability › Watertight Integrity › General
Issued 26 May 2010 Resolved
Prove proper operation of WTD and light.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Examined/cleared.
Engineering › Bilge Water Management System › Hose
Issued 26 May 2010 Resolved
Replace all bilge non-metallic hose with SAE J 1942 hose and 2 hose clamps at each fitting.
Due 27 June 2010
Resolved 28 June 2010
Resolution: Rcvd e-mail photo indicating completion.
Operations/Management › Ballast Water Managment › Sediments
Issued 26 May 2010 Resolved
Remove debris beneath bunks of galley.
Due 27 June 2010
Resolved 1 June 2010
Resolution: Rcvd e-mail photos.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 May 2010 Resolved
Submit proposal for periphery deck rails where passengers may have access. Proposal should be in accordance with requirements of 46 CFR 177.900 (New T) or 46 CFR 177.35-1 (Old T). Vessel restricted from carrying more than 6 passengers until plan is approved and rails nstalled.
Due 27 June 2010
Resolved 15 June 2010
Resolution: Rcvd proposal w/ picture. Per 46 CFR 177.35-1(a) (Old T), hand grabs (installed) accepted in lieu of periphery deck rails due to space limitations. Issued #25 to install chains w/ passenger restricted signage.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 May 2010 Resolved
Complete satisfactory drills.
Action required: 705 - Other - as specified
Resolved 27 May 2010
Resolution: Witnessed satisfactory drills.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 May 2010 Resolved
Submit proposal to permanently repair engine room bulkhead, forward where wasted.
Due 27 June 2010
Resolved 25 June 2010
Resolution: Rcvd proposal 01Jun10. Approved 15Jun10. Rcvd photos indicating completion 25Jun10.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 August 2009 Resolved
Provide First Aid Kit
Action required: 705 - Other - as specified
Due 24 September 2009
Resolved 24 August 2009
Resolution: First Aid Kit provided
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 August 2009 Resolved
Provide alcohol test kits
Action required: 705 - Other - as specified
Due 24 September 2009
Resolved 24 September 2009
Resolution: Received e-mail confirming alcohol test kits provided
Construction/Loadline › Structures › Superstructure
Issued 24 August 2009 Resolved
Replace cracked bridge windows, prior to 2010 season.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 26 May 2010
Resolution: Examined/cleared.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 October 2007 Resolved
Vessels annual reinspection is overdue. Annual reinspection was due 01 OCT2007. Vessel AOR is iced in and vessel is on blocks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2007
Resolved 29 May 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 31 August 2006 Resolved
Provide FCC Safety Certificate
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 29 April 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 31 August 2006 Resolved
Provide proof of enrollment in DOT approved drug program.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 25 September 2006
Engineering › Fuel Oil Service System › Valve
Issued 31 August 2006 Resolved
Label in 1 inch letters "Emergency Fuel Shut Off" and direction of operation
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 25 September 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 August 2006 Resolved
Install corrosion resistant clip on ring buoy water-light lanyard.
Due 30 September 2006
Resolved 25 September 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 May 2006 Resolved
Install captive chain on FWD peak hatch
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 30 June 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 May 2006 Resolved
Replace gasket on FWD peak hatch cover
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 24 May 2006 Resolved
Remove excess scale in foward peak & lazareete
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Stability › Weathertight Integrity › General
Issued 24 May 2006 Resolved
Make watertight eng room fwd watertight door
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Construction/Loadline › Hull › Side Shell
Issued 24 May 2006 Resolved
Drill stop/ V& re-weld crack on side shell IWO starboard side shell
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Construction/Loadline › Hull › Weld
Issued 24 May 2006 Resolved
Drill stop/ V& re-weld crack on starboard weather deck at frame 4ft fwd of freeing port
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 May 2006 Resolved
V/W transom stiffeners, bottom longitudinal & deck longitudinal at transom as marked in lazareete.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Stability › Weathertight Integrity › General
Issued 24 May 2006 Resolved
re-new 6ea lazareete hatch cover bolts
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Stability › Watertight Integrity › General
Issued 24 May 2006 Resolved
Replace lazareete hatch cover gasket
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 30 June 2006
Lifesaving › Hand Flares › Marking
Issued 1 July 2005 Resolved
Segregate expired flares in a container labeled "expired flares" and store in separate space from current flares.
Due 1 August 2005
Resolved 23 August 2005
Resolution: photo on file
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 July 2005 Resolved
Provide one additional type 1 child size lifejacket to satisfy requirements on COI. Passengers limited to 10 adults and 1 child until corrected.
Due 1 August 2005
Resolved 30 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2005 Resolved
Remove all dead end wiring in E/R at next dry dock.
Due 18 May 2006
Resolved 30 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2005 Resolved
Replace lightbulb and provide guard for starboard engine overhead lighting.
Due 1 August 2005
Resolved 30 August 2005
Resolution: photo on file
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 July 2005 Resolved
Perform maintenance on generator room watertight door to ensure all dogs work and hatch is made watertight.
Due 1 August 2005
Resolved 30 August 2005
Resolution: photo on file
Electrical › Electrical Distribution System (service) › Cable
Issued 1 July 2005 Resolved
Provide means of running electric cable for portable mast head light so that it does not interfere with E/R ventillation intake closures.
Due 1 August 2005
Resolved 30 August 2005
Resolution: photo on file
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 May 2004 Resolved
PFDs not marked with vessel's name.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2004
Resolution: Item corrected prior to departure.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 May 2004 Resolved
Fixed CO2 system for engineroom is overdue for servicing. Provide copy of servicing report from tech rep.
Condition: Improper/Lack of Maintenance
Due 11 June 2004
Resolved 1 July 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 August 2003 Resolved
Anchor light didn't work.
Condition: Unknown
Due 14 August 2003
Resolved 7 August 2003
Resolution: Corrected during boarding.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 August 2003 Resolved
Pilot light didn't work.
Condition: Unknown
Due 14 August 2003
Resolved 7 August 2003
Resolution: Corrected during boarding.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 August 2003 Resolved
Crfew training not documented.
Condition: Unknown
Due 14 August 2003
Resolved 7 August 2003
Resolution: Educated Master & Owner & cleared.
Communications › Radio Communications › EPIRB
Issued 7 August 2003 Resolved
EPIRB release not marked with expiration date.
Condition: Improper/Lack of Maintenance
Due 7 August 2003
Resolved 7 August 2003
Resolution: Contacted lifesaving service techs who provided receipt with date of purchase of release & expiration date. Release properly marked.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 August 2003 Resolved
Engine room emergency escape not marked.
Condition: Improper/Lack of Maintenance
Due 21 August 2003
Resolved 18 August 2003
Construction/Loadline › Markings
Issued 7 August 2003 Resolved
Vessel name and hailing port not marked on hull. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Due 14 September 2003
Resolved 17 October 2003
Resolution: Reviewed photos of vessel name and hailing port on stern.
Deck/Cargo › Mooring/Anchoring
Issued 7 August 2003 Resolved
No anchor or anchor line on board vessel. LEGACY COMPONENT DESC: Anchor
Condition: Improper/Lack of Maintenance
Due 7 September 2003
Resolved 17 October 2003
Resolution: Reviewed photo of installed anchor and anchor chain.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 August 2003 Resolved
Missing 15 adult PFD's
Condition: Improper/Lack of Maintenance
Due 7 October 2003
Resolved 1 July 2005
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 7 August 2003 Resolved
Engine room not equipped with fire detection system.
Condition: Improper/Lack of Maintenance
Due 7 November 2003
Resolved 1 July 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 May 2002 Resolved
Provide documentation for fixed and portable fire extinguisher servicing.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2002
Resolved 30 May 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 May 2002 Resolved
Reinstall or renew main engine exhaust blankets. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2002
Resolved 30 May 2002
Stability › Weathertight Integrity
Issued 21 May 2002 Resolved
Install proper port light fixtures to main cabin, port and starboard sides.
Action required: 705 - Other - as specified
Due 21 June 2002
Resolved 3 June 2002
Construction/Loadline
Issued 5 August 2000 Resolved
REPLACE TWO CRACKED PILOT HOUSE WINDOWS.
Condition: Unknown
Due 5 August 2000
Resolved 5 August 2000
Lifesaving
Issued 5 August 2000 Resolved
CONDUCT A SOUND LEVEL SURVEY IN THE PASSENGER AREA TO ENSURE NOISE LEVEL DOES NOT EXCEED THE NOISE LEVEL WHICH REQUIRES HEARING PROTECTION.
Condition: Unknown
Due 5 August 2000
Resolved 5 August 2000
Construction/Loadline
Issued 5 August 2000 Resolved
REPLACE FORWARD PEAK DECK HATCH, COVER IS LEAKING AND UNABLE TO BE REPAIRED.
Condition: Unknown
Due 5 August 2000
Resolved 5 August 2000
Deck/Cargo
Issued 5 August 2000 Resolved
VESSEL DOES NOT HAVE ANY GROUND TACKLE, NEEDS TO INSTALL PROPER GROUND TACKLE IN ACCORDANCE WITH LOCAL OCMI. _x001C_ _x001C_
Condition: Unknown
Due 5 August 2000
Resolved 5 August 2000
Construction/Loadline
Issued 3 September 1999 Resolved
install a visual and audible alarm in bridge, as per 46 C.F.R. 182.530
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
install fixed fire fighting system in accordance with 46 C.F.R 181.400
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Construction/Loadline
Issued 3 September 1999 Resolved
repair laz bilge alarm, inoperative.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Engineering
Issued 28 August 1998 Resolved
RENEW CRACKED FUEL OIL FITTING AT FUEL FILTER ON PORT MAIN ENGINE. _x001C_ THIS ITEM TO BE CORRECTED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Lifesaving
Issued 1 August 1998 Resolved
PROVIDE BA WATERLIGHT
Condition: Unknown
Due 31 August 1998
Resolved 28 August 1998
Documentation
Issued 1 August 1998 Resolved
PROVIDE FCC RADIO OPERATORS PERMIT
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Construction/Loadline
Issued 1 August 1998 Resolved
RENEW BROKEN PORT ENGINEROOM PORT LIGHT.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Documentation
Issued 1 August 1998 Resolved
PROVIDE FCC SAFETY EQUIPMENT CERTIFICATE
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Engineering
Issued 1 August 1998 Resolved
RENEW SSDG FUEL OIL HOSE WITH APPROVED HOSE AND END FITTINGS.
Condition: Unknown
Due 31 August 1998
Resolved 28 August 1998
Electrical
Issued 1 August 1998 Resolved
PROPERLY HANG ELECTRICAL WIREING IN ENGINEROOM OVERHEAD.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Engineering
Issued 25 April 1995 Resolved
Make permanent repairs to fractures at the bases of the blades on both portand starboard screws.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.