Records from 2001 to 2018. Most recent: inspection, 7 November 2018.
Inspection history · 41
7 November 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6576337
6 November 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6576059
18 August 2018
Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6505575
16 August 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6513704
9 August 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6505886
21 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6310776
22 June 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6183524
20 June 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6181434
13 June 2017
Administrative Inspection · Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6174346
23 December 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4212121
21 December 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3913863
7 December 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3640386
2 March 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3426666
5 November 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3357348
28 March 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3173282
20 September 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3062421
7 June 2007
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2954474
5 June 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952816
14 September 2006
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2778237
14 September 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2778322
13 September 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2777080
26 January 2006
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2573791
17 August 2005
ISPS III Exam · NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2465810
16 August 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2465202
16 August 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2465250
21 January 2005
Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2278660
14 January 2005
ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2275122
28 October 2004
Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2230384
21 June 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2109683
17 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2101841
12 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2066093
12 February 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005790
8 October 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005537
28 August 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1889486
28 August 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1890095
20 July 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1852242
12 August 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1659867
8 August 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1659114
20 May 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1618339
26 July 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 292371
1 February 2001
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3597166
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 7 November 2018
No resolution recorded
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situation. PSCO noted system failure in the exhaust piping can re-occur without preventative maintenance. Discussed with ship captain and Chief Engineer maintenance actions to prevent re-occurrence of conditions to address three generators and main diesel engine, through safety management system procedures modification and through designated person ashore.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 December 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 November 2018
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE NO. 2 SHIP SERVICE GENERATOR WAS INOPERABL.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2018
Resolved 7 November 2018
Resolution: The drain pipe on top of funnel was found stuck and drain pipe on bottom of exhaust pipe was also found clogged. These were clean by crew to ensure the draining function working in order. Engine tested for two hours w/o malfunction.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 13 June 2017
Resolved
0750 - #1 MAIN ENGINE CYLINDER HAD LARGE FUEL OIL LEAK UNDER MAIN CYLINDER HOUSING. 74SOLAS(01 CONS.)II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2017
Resolution: Received Class DNV-GL report attesting to satifactory rectification.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 13 June 2017
Resolved
1581- DURING STEERING TEST PSCO'S NOTED A 4 DEGREE DIFFERENCE BETWEEN STEERING GEAR ROOM AN DBRIDGE RUDDER ANGLE INDICATORS. WHEN AT 30 DEGREES PORT IN STEERING ROOM, BRIDGE REPORTED 26 DEGREES, OVER 3 SEPERATE TESTS. 74SOLAS(04CONS)II-1/29.11.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2017
Resolution: Received Class DNV-GL report attesting to satifactory rectification.
Construction/Loadline › Hull › Stiffener
Issued 27 November 2009
Resolved
Crack at weld on additional bracket placed near frame number 102 during recent hull crack repair. Crack is on weld at frame/bracket. Provide report attesting that the ship is maintained in conformity with requirements of class society recognized by administration. Any additional repairs necessary mmust be completed prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: Added temporary weld to be fixed in dry dock
Lifesaving › Launching Appliances › Release Mechanism
Issued 27 November 2009
Resolved
Emergency release cable for the starboard side lifeboat parted during drill. Repair/replace to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: Replaced the emergency release cable.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 March 2009
Resolved
Received an LOD request for a gyro compass that is out of order. LOD issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2009
Resolution: Ship had independent second gyro that met all regulations. All sat. Vsl did not require outbound LOD.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 5 November 2008
Resolved
Portable cooling fan was being used in purifier space to cool the main engine fuel oil circulation pump, posing a fire hazard. Provide report from class of the fixtures of the overheating problem on the main engine fuel oil circulation pump. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 December 2008
Resolution: Rec''d sat class report.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 28 March 2008
Resolved
X-Band Radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2008
Resolution: 31Mar08 - Vessel requested outbound LOD. Informed agent that no need for outbound LOD because they have 2 fully functional Radars both with ARPA.
Electrical › Electric Generation Source (emergency) › Generator
Issued 20 September 2007
Resolved
VESSEL EMERGENCY GENERATOR IS UNABLE TO AUTO START UPON LOSS OF NORMAL POWER AND TAKE EMERGENCY LOAD. 74 SOLAS AS AMENDED II-1 REG 43.3.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2007
Resolution: RELAY CABLES WERE INSPECTED AND FOUND LOOSE CONNECTION. DEFIENCIENCY RECTIFIED.
Fire Fighting › Fire Hoses › Condition
Issued 20 September 2007
Resolved
THE FIRE FIGHTING HOSE STORAGE STATIONS ARE LOCKED OR HAVE A HEAVY PLASTIC STRAP TIE. BOTH PREVENT IMMEDIATE ACCES TO THE FIRE HOSES AND FIRE NOZZLES. SOLAS 74 AMENDED II 2/21
Due 20 September 2007
Resolved 20 September 2007
Resolution: LOCKS AND OR STRAP TIES WERE REMOVED.
Fire Fighting
Issued 26 July 2001
Resolved
STOWAGE OF FLAMMIBLE LIQUIDS IN STEERING FLAT. CORRECTED ON THE SPOT. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001