Records from 1990 to 2019. Most recent: inspection, 5 September 2019.
Documentation record
Registered dimensions (L × B × D)46.7 ft × 13.8 ft × 4.8 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJENNING'S BOATYARD · REEDVILLE, VA, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portTANGIER, VA
Trade endorsementsFishery
DocumentationValid · issued 21 May 2026 · expires 30 April 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton
20 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
5 September 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6804594
16 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6514639
25 January 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6344100
24 April 2017
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6131570
11 April 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5851842
8 December 2015
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5781184
8 December 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5805502
29 May 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4874179
13 June 2012
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4343045
12 May 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4311031
16 February 2012
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4247985
18 February 2010
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3683709
17 July 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3541348
28 August 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3311916
6 March 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3159908
21 December 2007
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3119222
19 June 2007
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2969553
11 July 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2711289
14 June 2006
Deficiency Check · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2681505
16 September 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2506733
8 March 2005
Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2306816
8 September 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2306786
16 June 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2097874
9 September 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1924914
18 June 2002
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1633598
21 June 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1417389
28 August 2000
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453811
24 June 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1463491
11 March 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 805366
9 July 1998
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 794834
8 July 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1371902
9 June 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1110068
24 June 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416342
7 July 1995
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 884368
7 July 1995
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383019
18 June 1994
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428366
18 June 1993
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1152813
10 September 1992
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1264104
28 July 1992
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1267832
10 January 1992
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 943801
22 July 1991
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1255458
26 July 1990
Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1214433
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 13 June 2012
Resolved
IMO Res A.658(16) Annex 2 (3.1) The brightness of the retro-reflective material when tested should be not less than 80% of its original installation. Retroreflactive material is worn. Replace with new as required.
Due 15 June 2012
Resolved 15 June 2012
Resolution: Retroreflactive material replaced with new.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 June 2012
Resolved
IMO Res A.658(16) Annex 2 (3.1) The brightness of the retro-reflective material when tested should be not less than 80% of its original installation. Retroreflactive material is worn. Replace with new as required.
Due 15 June 2012
Resolved 15 June 2012
Resolution: Retroreflective material replaced with new.
Lifesaving › Lifefloat › Paddle
Issued 13 June 2012
Resolved
46 CFR 180.175 (d) Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. One life float paddle is wasted. Replace with new.
Due 15 June 2012
Resolved 15 June 2012
Resolution: Life float paddle replaced with new.
Lifesaving › Lifefloat › Paddle
Issued 13 June 2012
Resolved
46 CFR 180.175 (f)(2) Each life float paddle must be at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Paddles for both life float are not lashed. Lash paddles as required.
Condition: Improper Installation
Due 15 June 2012
Resolved 15 June 2012
Resolution: Life float paddles are lashed to the life float to the satisfaction of the attending marine inspector.
Lifesaving › Lifefloat › Serviceable
Issued 13 June 2012
Resolved
46 CFR 180.137 (f) Life floats and buoyant apparatus must not be stored in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. Life floats are stored on top another without separation. Provide separation as required.
Condition: Improper Installation
Due 15 June 2012
Resolved 15 June 2012
Resolution: Spacers provided to the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 June 2012
Resolved
46 CFR 180.70 (d)(3) Each floating water light on a vessel carrying only one ring buoy must be attached to the lanyard with a corrosion resistant clip. Clip seized and installed incorrectly. Replace clip with new and install as required.
Condition: Improper Installation
Due 15 June 2012
Resolved 15 June 2012
Resolution: Clip replaced with new and installed to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Service System › Tank
Issued 13 June 2012
Resolved
46 CFR 182.445 (d) Fill pipes and sounding pipes must be arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. Fuel fill installed below the main deck without any type of containment. Install on main deck or provide containment as required.
Condition: Improper Installation
Due 15 June 2012
Resolved 15 June 2012
Resolution: Containment installed to the satisfaction of the attending marine inspector.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007
Resolved
Provide approved fire detection system or alternative system substitute.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 31 December 2008
Resolution: Installed pre-engineerered sysytem.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007
Resolved
Provide plan for installation of approved fire detection system and log daily system checks of current system.
Due 15 July 2007
Resolved 13 December 2007
Resolution: Plan was approved and new system was installed
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007
Resolved
Provide approved fire detection system or alternative system substitute.
Due 31 December 2007
Resolved 13 December 2007
Resolution: Installed CG approved pre-engineered fixed fire fighting (FE-241) system to comply with 46 CFR 181.420.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 19 June 2007
Resolved
Provide plan for installation of approved fire detection system and log daily checks of current system.
Due 31 December 2007
Resolved 13 December 2007
Resolution: Installed CG approved pre-engineered fixed fire fighting system (FE-241) to comply with 46 CFR 181.420.
Lifesaving › Lifefloat › Painter
Issued 11 July 2006
Resolved
Renew sea painter to lifefloat.
Due 21 July 2006
Resolved 25 July 2006
Resolution: Replaced sea painter.
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 July 2006
Resolved
Renew fresh water wash down located within the engine compartment. Current hose is split and leaks into space.
Due 21 July 2006
Resolved 11 July 2006
Resolution: Replaced hose. Verified by marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 14 June 2006
Resolved
Bottom plank on port side, approximately amidships, needs to be replaced due to rot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2006
Resolution: Replaced plank.
Construction/Loadline › Penetrations
Issued 18 June 2002
Resolved
Re-Bed rudder post into hull prior to refloating vessel. LEGACY COMPONENT DESC: Rudder Post
Action required: 705 - Other - as specified
Resolved 20 June 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2002
Resolved
Remove old unsed transducer wiring.
Action required: 705 - Other - as specified
Resolved 20 June 2002
Fire Fighting
Issued 24 June 1996
Resolved
Two B-I fire extinguishers need to be serviced.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Engineering
Issued 24 June 1996
Resolved
Exhaust system missing heat sensor, need to install.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Navigation
Issued 24 June 1996
Resolved
Charts and 46 CFR sub-chapter "T" are out dated, up dated copies needed.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Documentation
Issued 28 July 1992
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Engineering
Issued 28 July 1992
Resolved
REPLACE PUSH ON FUEL FITTING WITH COMPRESSION FITTING ON SUCTION AND DISCHARGE SIDES OF THE FUEL OIL SYSTEM.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992