Inspection history · 42
16 January 2025
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8096265
9 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7946707
11 January 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7850156
6 October 2023
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7812879
16 August 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7780655
26 July 2023
Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7803695
17 May 2023
Deficiency Check · Attraction Vessel Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7694104
8 November 2022
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591706
3 October 2022
Deficiency Check · Administrative Inspection · Excursion Permit · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7570497
18 August 2022
Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7548351
2 May 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7460008
20 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7435010
5 August 2021
Annual Inspection · Excursion Permit · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7291645
11 March 2021
Examination of Repairs · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7154517
16 October 2020
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7078769
13 January 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6888669
9 October 2019
Excursion Permit · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6831687
7 June 2019
Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6719441
9 May 2019
Administrative Inspection · In-Service Inspection · Annual Inspection · Excursion Permit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6680771
15 March 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6643103
10 January 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6608658
4 October 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6553938
28 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6550486
18 May 2018
Administrative Inspection · Annual Inspection · Excursion Permit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6421423
27 April 2018
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6405895
31 October 2017
Drydock Exam
Physical examination · Commandant (CG-5P-TI) · Activity 6375783
16 October 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6295140
6 October 2017
Excursion Permit · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6288580
28 September 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6277485
6 September 2017
Administrative Inspection · Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6261161
29 July 2017
Administrative Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6244933
7 July 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6201023
12 June 2017
Hull Examination · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6173478
20 May 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6345474
10 May 2017
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6143159
18 April 2017
COI Inspection · MTSA Verification · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6127077
7 February 2017
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6089412
12 December 2016
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6056472
12 September 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5998893
19 August 2016
Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5977571
20 June 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5913281
15 April 2016
Excursion Permit · Administrative Inspection · In-Service Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5862849
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 January 2025
Resolved
On a merchant vessel of the United States the construction of which began after March 4th, 1915..(5) each crew berthing area shall be equipped with information regarding-(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and(B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information-(i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard;(ii) on vessel owner or company procedures to report violations of company policy and access resources;
(iii) on resources provided by outside organizations such as sexual assault hotlines and counseling;(iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported; and (v) additional items specified in regulations issued by, and at the discretion of, the Secretary of the department in which the Coast Guard is operating. 46 U.S.C. 11011(a)(5)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 February 2025
Resolution: Vessel posted appropriate signage.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 January 2025
Resolved
In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. Required signage missing from vessel washrooms. 46 U.S.C. 11011(d)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 February 2025
Resolution: Vessel posted appropriate signage.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 January 2025
Resolved
(a) In General.-The owner of a vessel subject to inspection under section 3301 shall-
(1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2);
(2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system;
(3) record in a log book information on all access and use of the vessel's master key, including-
(A) dates and times of access;
(B) the room or location accessed; and
(C) the name and rank of the crew member that used the master key; and
(4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. 46 U.S.C. 3106
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 February 2025
Resolution: Key Control and assiciated logs verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2023
Resolved
Vessel is to maintain feedwater chemistry in accordance with the boiler manufacture’s technical manual. Prove proper feedwater chemistry to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2024
Resolution: Ongoing discussion with O/O have determined that this requirement cannot be met under the current operating schedule. O/O aware of deterioration that can be caused.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2023
Resolved
At each inspection for certification and periodic inspection, the inspector shall examine the tank tops and bilges in the machinery spaces to see that there is no accumulation of oil which might create a fire hazard. Vessel has accumulated an excessive amount of oily water and oily build up in the engine room. 46 CFR 91.25-40
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: ER bilges cleaned, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2023
Resolved
Each boiler, including superheater, reheater, economizer, auxiliary boiler, low-pressure heating boiler, and unfired steam boiler, must be available for examination by the marine inspector at intervals specified by Table 61.05–10, and more often if necessary, to determine that the complete unit is in a safe and satisfactory condition. When a hydrostatic test is required, the marine inspector may examine all accessible parts of the boiler while it is under pressure. Port boiler is overdue for required inspections. 46 CFR 61.05-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2023
Resolution: Port Boiler and Piping hydroed to 312.5 psi, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 August 2023
Resolved
Except as provided in paragraphs (b) through (g) of this section, each vessel must undergo drydock, internal structural, and cargo tank internal examinations as follows:Except under paragraph (a)(2) of this section, vessels that operate in salt water must be examined in accordance with the intervals set forth in Table 91.40–3(a) of this section. Vessel is overdue for completing required internal structural exams.
Action required: 705 - Other - as specified
Resolved 6 March 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 28 August 2023
Resolved
If, during an internal structural, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. #3 Port Deep tank has through thickness deterioration providing free communication from the tank to the engine room. Permanent repairs to be completed. 46CFR91.40-39(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2023
Resolved 19 April 2024
Resolution: Crop/Renew steel repairs complete and tested satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2023
Resolved
Each fuel oil tank with at least one side integral to the vessel's hull and located within the hull (“integral fuel oil tank”) is subject to inspection as provided in this section. The owner or operator of the vessel shall have the tanks cleaned out and gas freed as necessary to permit internal examination of the tank or tanks designated by the marine inspector. Make tanks 5P DB and 3S DB clean and available for inspection by 31DEC2024. 46 CFR 91.43-1(a)
Action required: 705 - Other - as specified
Due 31 December 2024
Resolved 2 April 2026
Resolution: 5P DB 5.1.25
3S DB 4.2.26
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2023
No resolution recorded
Each fuel oil tank with at least one side integral to the vessel's hull and located within the hull (“integral fuel oil tank”) is subject to inspection as provided in this section. The owner or operator of the vessel shall have the tanks cleaned out and gas freed as necessary to permit internal examination of the tank or tanks designated by the marine inspector. Make 2P DB clean and available for inspection by 31DEC2025. 46 CFR 91.43-1(a)
Action required: 705 - Other - as specified
Due 31 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2023
No resolution recorded
Each fuel oil tank with at least one side integral to the vessel's hull and located within the hull (“integral fuel oil tank”) is subject to inspection as provided in this section. The owner or operator of the vessel shall have the tanks cleaned out and gas freed as necessary to permit internal examination of the tank or tanks designated by the marine inspector. Make 1 CL DB clean and available for inspection by 31DEC2026. 46 CFR 91.43-1(a)
Action required: 705 - Other - as specified
Due 31 December 2026
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2023
No resolution recorded
Each fuel oil tank with at least one side integral to the vessel's hull and located within the hull (“integral fuel oil tank”) is subject to inspection as provided in this section. The owner or operator of the vessel shall have the tanks cleaned out and gas freed as necessary to permit internal examination of the tank or tanks designated by the marine inspector. Make tanks 2S DB and 3P DB clean and available for inspection by 30NOV2027. 46 CFR 91.43-1(a)
Action required: 705 - Other - as specified
Due 30 November 2027
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 May 2023
Resolved
It shall be the duty of the master or PIC to ensure the vessel’s firefighting equipment is at all times ready for use and maintained properly. One of two SCBA’s found not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 28 June 2023
Resolution: SCBA testing/maintenance records provided
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2023
Resolved
In the inspection of hulls, boilers, and machinery of vessels, the standards established by ABS and the certificate of classification shall be accepted as standard by the inspectors. Vessel’s Class Certificate is expired due to overdue drydock exam. Provide documentation for force majeure details.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 26 May 2023
Resolution: Received acceptance verification from ABS
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 May 2023
Resolved
All officers on a vessel must have their licenses or officer endorsements conspicuously displayed. Onboard documentation for credentialed mariners was insufficient to determine whether mariners were qualified for the position they were serving or that the credentials were not expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 11 July 2023
Resolution: Validated crew list for dockside operational period.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2023
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces storing carbon dioxide - “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”. CO2 warning sign missing outside main CO2 storage room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 12 June 2023
Resolution: Signage added to CO2 storage space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2023
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, and other persons, and the vessel from electrical hazards. Cargo hold 5 tween deck had daisy chained electrical cords near laundry.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 11 July 2023
Resolution: Daisy chained electrical removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 May 2023
Resolved
There shall be at least two means of escape from areas where crew is normally employed. Multiple escape trunks from engine room and lower cargo holds found cluttered with cables or other debris that would hinder emergency escape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
Resolution: Items removed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 May 2023
Resolved
Every crewmember must participate in at least one abandon ship drill and one fire drill every month. The OCMI may accept other equivalent drill arrangements for those classes of vessel for which compliance with this paragraph is impracticable. Historic record of safety drills was not available. Current records have a gap of 6 months with no drills conducted. Drill intervals found insufficient based on ship operations.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
Resolution: Crew reminded of drill requirements going forward.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2023
Resolved
Approved portable fire extinguishers must be installed in accordance with Table 95.50-10(a) of this section. The location of the equipment must be to the satisfaction of the [name withheld] portable extinguishers onboard found not properly secured.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
Resolution: Portables stowed properly.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 May 2023
Resolved
It shall be the duty of the master or PIC to ensure the vessel’s firefighting equipment is at all times ready for use and maintained properly. Main deck emergency locker found locked with combination lock.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 May 2023
Resolution: Lock removed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 18 May 2023
Resolved
Nontank vessels subject to this subpart may not—continue to operate on the navigable waters of the United States if—The vessel is not operating in compliance with the submitted VRP. Vessel could not provide documentation that the engineering crew, holding responsibility for spill response mitigation, had been provided training or participated in emergency procedures exercises as required by the approved NTVRP. Correct prior to operating any machinery or conducting transfer operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2023
Resolution: Evidence provided to document crew training on spill response.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 18 May 2023
Resolved
No person may operate a U.S. non-oceangoing ship in the navigable waters of the United States, unless it has the capacity to retain on board all oily mixtures and is equipped to discharge these oily mixtures to a reception facility. Vessel witnessed discharging bilge water ashore via their sewage connection without valid approval permitting from the municipality. Discharge was not made through oily-water separating equipment as is required with municipal permits. Correct prior operating machinery or conducting transfer operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 June 2023
Resolution: Vessel provided revised bilge water management procedures and created controled valve list.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2023
Resolved
Fire pumps may be used for other purposes provided at least one of the required pumps is kept available for use on the fire system at all times. In no case shall a pump having connection to an oil line be used as a fire pump. Water produced by the ships fire pump was witnessed bearing what appeared to be a petroleum oil sheen. Correct prior operating machinery or conducting transfer operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 July 2023
Resolution: Vessel cleaned fire main piping of contaminates and controlled valves for cross connection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2023
Resolved
Safety and relief valves for steam or air service shall be provided with a substantial lifting device so that the disk can be lifted from its seat when the pressure in the vessel is 75 percent of that at which the valve is set to blow. 02 relief valves were identified on the #220 steam line just forward of the stbd boiler missing their lifting devices.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 11 July 2023
Resolution: Witnessed installation of missing hand relieving devices.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 May 2023
Resolved
No more than 19 liters (five gallons) of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 liters (one gallon) or less. Paints and solvents were found in shaft alley outside of the installed paint lockers in containers exceeding the one gallon limit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 11 July 2023
Resolution: Verified removal of hazardous stores from shaft alley.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 May 2023
Resolved
Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, until replacement is deemed necessary by such officer or as specified in the regulations. The viewing port on the middle aft burner of the stbd boiler has broken lose and is no longer maintaining a boundary for the furnace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 11 July 2023
Resolution: Inspected renewed sight glass.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 May 2023
Resolved
If a District Commander determines that the overall safety of the persons on board a vessel will not be significantly reduced, the District Commander may grant an exemption from compliance with a provision of this part to a specific vessel for a specified geographic area within the boundaries of the Coast Guard District. This exemption may be limited to certain periods of the year. Requests for exemption under this paragraph must be made in writing to the OCMI for transmission to the District Commander for the area in which the vessel is in service or will be in service. If the exemption is granted by the District Commander, the OCMI will endorse the vessel's Certificate of Inspection with a statement describing the exemption. Vessel identified utilizing a passenger vessel primary lifesaving allowance not applicable to the vessel. Vessel shall submit a proposal detailing their requested number and type of lifesaving appliances for review.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 13 February 2025
Resolution: Reply under review.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2023
Resolved
Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, until replacement is deemed necessary by such officer or as specified in the regulations. Main circ pump was identified as having a broken slinger ring which has been held together by a hose clamp. Correct prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 August 2023
Resolution: Repaired satisfactorially.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2023
Resolved
Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge, Marine Inspection, until replacement is deemed necessary by such officer or as specified in the regulations. The fire/general service pump has a hose clamped rubber patch on the discharge line connection point. Correct prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Pipe cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2022
Resolved
It shall be the duty of the master or PIC to ensure the vessel's firefighting equipment is at all times ready for us and maintained properly. Portable fire extinguisher #11 did not have an inspection tag showing it is being properly maintained and serviced.
Action required: 705 - Other - as specified
Resolved 6 May 2022
Resolution: GFS provided tag.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 April 2022
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. 175 adult life-jackets were condemned due to non-serviceability. Replace all 175 condemned life-jackets prior to issuance of next Excursion Permit in order to maintain 900 passenger count.
Action required: 705 - Other - as specified
Resolved 17 May 2022
Resolution: Reduced Passenger allowance on currect Excursion Permit.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 April 2022
Resolved
There shall be at least two means of escape from areas where crew is normally employed. Escape platform from the engineroom on the 02 deck is blocked with miscellaneous books and equipment. Remove all excess material prior to issuance of next Excursion Permit.
Action required: 705 - Other - as specified
Resolved 6 May 2022
Resolution: All material was moved to CHENGS office.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2022
Resolved
It shall be the duty of the master or PIC to ensure the vessel's firefighting equipment is at all times ready for us and maintained properly. Condemned on (1) fire hose. Vessel replaced with a new hose.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2022
Resolution: Hose was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 January 2021
Resolved
Each vessel must undergo internal structural examinations in accordance with the intervals set forth in Table 91.40-3(a). Where Table 91.40-3(a) indicates a 2.5 year examination interval, it means a vessel must undergo two examinations within any five year period. 1 Center DB Ballast tank is overdue for internal inspection.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 January 2021
Resolved 5 August 2021
Resolution: ISE completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 October 2020
Resolved
Each vessel must undergo internal structural examinations in accordance with the intervals set forth in Table 91.40-3(a). Where Table 91.40-3(a) indicates a 2.5 year examination interval, it means a vessel must undergo two examinations within any five year period. Internal structural exam is overdue (due date 31MAY19).
46 CFR 91.40-3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2020
Resolved 11 December 2020
Resolution: Vessel completed ISE with the exception of 1 Center DB Ballast. Separate 835 entered to track remaining tank.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 May 2019
Resolved
The position of the rudder, if power-operated, must be shown at the principal steering station. Rudder angle indicators on the bridge and flying bridge (principal steering station) are off by more than 30 degrees. Repair both rudder angle indicators and demonstrate proper operation.
46 CFR 113.40-5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 May 2019
Resolved 17 May 2019
Resolution: Witnessed satisfactory operation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 June 2021
Resolution: Corrected
Engineering › Steam Boiler (propulsion) › Screen Tube
Issued 29 July 2017
Resolved
Make repairs to leaking screen tube in the port boiler.
Action required: 60 - Rectify deficiencies prior to movement
Due 18 August 2017
Resolved 17 August 2017
Resolution: Aftermost 4" screen tube in the port boiler was replaced by onboard ships spare. Satisfactory hydro test conducted.
Electrical › Electric Generation Source (service) › Generator
Issued 19 August 2016
Resolved
Vessel's crew may not use the aux AC generator installed in the #5 tween deck until plan review has been completed by MSC and all testing and inspections conducted to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 26 October 2017
Resolution: OCMI plan review approval granted, letter issued.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 20 May 2016
Resolved
Provide proof of current valid FCC Vessel Bridge to Bridge Radiotelephony Cert. as per 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 29 June 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 May 2016
Resolved
Provide proof of a current/valid Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 29 June 2016