Records from 1995 to 2011. Most recent: inspection, 20 August 2011.
Inspection history · 24
20 August 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4121413
31 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3936205
19 December 2007
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3118018
20 September 2007
MARPOL Annex I Examination · NPV Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3059288
18 October 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2803210
17 October 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2802187
1 September 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2472223
28 February 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2301038
16 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2222266
21 September 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2201032
26 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2178106
8 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2159993
5 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2157193
5 August 2004
ISM Exam · NPV Safety Exam · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2157414
30 July 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2150879
18 June 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 291213
26 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 288759
15 February 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 287103
20 October 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 283364
3 January 2000
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 273331
12 November 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 422543
15 April 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 402302
19 October 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 383689
18 April 1995
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 377495
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 September 2007
Resolved
Vessel’s fire control plan does not appear to accurately reflect configuration of vessel’s Structural Fire Protection arrangements. Specifically, class “A” and “B” doors. SEE NARITIVE
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 19 December 2007
Resolution: Satisfaction to Class, survey faxed to Coast Guard
Construction/Loadline › Markings › Load Line Mark
Issued 20 September 2007
Resolved
The loadline mark on the starboard side of the vessel does not match the International Load Line certificate.
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 19 December 2007
Resolution: Satisfaction to Class, survey faxed to Coast Guard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 October 2006
Resolved
Alarm/shutdown not engaging at 15ppm. Fix prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 October 2006
Resolution: Received Class Report attesting to repairs.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 17 October 2006
Resolved
One battery bank not powerful enough to start emergency generator in reasonable time (10+ min). Ship must demonstrate two means of starting the emergency generator. Fix prior to departure.
Action required: 705 - Other - as specified
Resolved 18 October 2006
Resolution: Received Class Report attesting to repairs.
Engineering › Electric Propulsion System › Feeder Circuitry
Issued 21 September 2004
Resolved
When the vessel departed the dock the crew did not have control of the main engine from the bridge. Control of the main engine was done from the engine control room only.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2004
Resolved 21 September 2004
Resolution: A loose wire was found and replaced on the the CPU control unit (No 121) and two electronic cards were replaced.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 8 August 2004
Resolved
The free-fall lifeboat has a exhaust gas leak. Repairs must be done to the satisfaction of the Classification Society Representative prior to the vessels departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2004
Resolved 13 August 2004
Resolution: Marine Repair company replaced the muffler
Lifesaving › Launching Appliances › Davit
Issued 8 August 2004
Resolved
The lifeboat was launched on the evening of 7 August by the Master. It was then placed on the midship hatch cover by using the ship's crane. The free-fall lifeboat must be placed back in its cradle under the supervision of the Classification Society Representative prior to the vessel's departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2004
Resolved 12 August 2004
Resolution: The Classification Representative (BV) supervised the restowing of the lifeboat.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 8 August 2004
Resolved
Due to the various safety related items that are in question a ISM audit must be conducted by the Classification Society or flag state representative.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2004
Resolved 26 August 2004
Resolution: The third and final ISM audit was conducted by the Classification Representative [name withheld] was downgraded to a non-conformity.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 August 2004
Resolved
Fire and lifeboat drills not conducted.
Action required: 15 - Rectify deficiencies by next port
Due 31 August 2004
Resolved 13 August 2004
Resolution: Lifeboat and fire drills were completed.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 5 August 2004
Resolved
Due to evidence of excessive alcohol consumption, safe control of ship is in question.
Cargo Operations were halted @ 1355 PST 06-08-2004, Cargo Operations may resume @ 1600 PST 07-08-2004 dependant upon limited alcohol consumption.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2004
Resolution: The CID held a meeting, which included a representative from the company and the BV representative. After the meeting permission was granted to resume cargo operations.
Fire Fighting
Issued 15 February 2001
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS BY A RECOGNIZED SERVICING AGENCY PRIOR TO 15MAR01.
Condition: Unknown
Due 15 March 2001
Resolved 15 March 2001
Documentation
Issued 15 February 2001
Resolved
UPDATE YOUR CARGO SECURING MANUAL IAW 49 C.F.R. TO REFLECT THAT ALL VEHICLES MUST BE LESS THAN 1/4 OF A TANK OF GAS AND ALL KEYS REMOVED FROM IGNITIONS.
Condition: Unknown
Due 20 June 2001
Resolved 20 June 2001
Unknown
Issued 3 January 2000
Resolved
PROVIDE WRITTEN WASTE MANAGEMENT PLAN FOR THE VESSEL.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 3 January 2000
Resolved
PROVIDE TRANSFER PROCEDURES THAT MEET THE REQUIREMENTS OF 33 C.F.R. 155.750
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000
Unknown
Issued 3 January 2000
Resolved
SUBMIT BALLAST WATER REPORT FORMS AND MAINTAIN A RECORD OF REPORTS.
Condition: Unknown
Due 24 October 2000
Resolved 24 October 2000