Records from 2010 to 2023. Most recent: inspection, 27 April 2023.
Inspection history · 19
27 April 2023
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7676565
12 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576000
9 August 2022
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7528985
9 August 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7536606
4 April 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7424228
30 March 2022
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7424160
27 July 2021
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7235626
25 June 2021
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7234532
28 September 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7064894
28 January 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6897598
3 October 2019
Administrative Inspection · Annual Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6821432
28 November 2018
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6588068
25 October 2018
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6568653
1 October 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6550495
8 January 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6332363
27 July 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6213909
6 July 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5916755
24 March 2016
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5837976
13 January 2016
Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5790255
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022
No resolution recorded
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2022
Resolved
While underway, operator identified abnormal noise coming from outboard engine. Vessel safely returned to the dock under its own power and was taken out of service. Provide causal factor contributing to abnormal noise and corrective actions taken to resolve issue. Prior to returning to service, vessel must be cleared by USCG Marine Inspector from this office.
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2022
Resolved 30 August 2022
Resolution: Lower unit was replaced in kinda and witnessed operational test with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Both engines overheated during inspection.Prove proper operation of both engines to the satisfaction of a Marine Inspector.
46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Proceeded underway for approximately 20 minutes. Water pumps for both engines replaced. No issues noted.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 27 July 2021
Resolved
Radio stations must have an authorization granted by the Federal Communications Commission.
Radio Station Authorization expired in November 2020. Provide valid certificate.
47 CFR 80.405(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Received copy of radio certificate expiring 13NOV2030.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 27 July 2021
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the
individual vessel.
Placard could not be found on the vessel. Place next to radio.
46 CFR 184.506
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Placard placed IVO radio.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2021
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Posted stability letter is faded and illegible. Replace.
46 CFR 176.308
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Clear copy of stability letter displayed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2021
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Ring life buoy needs to be marked with vessel’s name.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Ring buoy properly stenciled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 July 2021
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck.
Relabel the number 12 for upper deck passenger limit on LBS LCW Route.
46 CFR 185.602(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 12 August 2021
Resolution: Upper deck passenger count labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 July 2021
Resolved
COI expired 06JUL2021. Prior to carrying passengers, complete COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2021
Resolved 12 August 2021
Resolution: COI inspection completed on this date.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 June 2021
Resolved
Make permanent repairs to the starboard hull forward of
the collision bulkhead outboard side and affected
internal longitudinal frames. Submit a repair proposal
prior to conducting repairs.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: New plate installed and tested with air test. Internal frames repaired. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 June 2021
Resolved
Repair cracked welds in #2 forward void on starboard
side lower longitudinals (#1 and #2 above turn of
bilge).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: All cracked welds ground out and rewelded. Affected hull plate replaced with 18"x18" insert.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 25 June 2021
Resolved
Make the bulkheads between #3 and #4 void on starboard
side (frame 15' from bow) and between #5 and #6 void on
port side (frame 27'6'' from bow) watertight. Starboard
side bulkhead has gaps between overhead and bulkhead
that would allow water to pass through in the event of
flooding. Port side bulkhead has cable runs penetrating
that are not properly sealed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Bulkhead were made watertight.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 June 2021
Resolved
Repair longitudinal overhead broken frame IWO fuel tank
along centerline of vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Frame repaired satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 September 2020
Resolved
Replace holed and wasted ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 9 October 2020
Resolution: Received photo of new life ring onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2019
Resolved
01 Lifejacket is inserviceable, destroy inserviceable life jacket, replace inserviceable lifejacket and provide proof of serviceable lifejacket to attending CG Marine Inspector. Reduce Passenger count to 48 until lifejacket is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 3 October 2019
Resolution: Vessel owner provided proof of purchase to inspectors via pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2018
Resolved
O/O reports an engine failure/loss of propulsion; starboard outboard engine is believed to have dropped a valve or piston. Mechanic to trouble shoot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Sea trial completed on two new engines, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 October 2018
Resolved
Replace netting on ripped area on starboard side (46CFR176.800)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
Resolution: Replaced ripped netting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Place word "adult" on lifejacket stowage on top deck. (46CFR185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
Resolution: Labeled lifejacket stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Place number of child lifejackets on lower deck storage. (46CFR185.604)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
Resolution: Placed number on deck storage area for lifejackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2018
Resolved
Update emergency instructions to actual vessel operations. (46CFR185.510)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
Resolution: Updated instructions.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 July 2016
Resolved
COD expired, do not carry passengers until cleared to a procesing status to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Provided valid certificate.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 July 2016
Resolved
Label lifejacket numbers.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 2 August 2016
Resolution: Labeled lifejacket numbers.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 July 2016
Resolved
Update Coast Pilot to 2016 edition.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 2 August 2016
Resolution: Provided 2016 Coast Pilot.
Construction/Loadline › Structures › Superstructure
Issued 13 January 2016
Resolved
Reweld supports for outboard upper deck support in #2 port void IAW 46 CFR 176.700.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: Fractures gouged and re-welded.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 January 2016
Resolved
Repair aft bulkhead bottom inboard side in #5 void port and clad weld hole starboard aft bulkhead centerline 4" up, IAW 46 CFR 176.700.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: Hole was cleaned and welded tight.
Construction/Loadline › Hull › Bottom Plating
Issued 13 January 2016
Resolved
Provide thickness readings for identified area/pits in port aft void, IAW 46 CFR 176.700.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: Reading taken were within acceptable wastage.
Fire Fighting › Fire Pumps › Suction Valve
Issued 13 January 2016
Resolved
Replace Fire/Bilge intake valve starboard side aft, IAW 46 CFR 176.700.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: Valve replace with new one.
Engineering › Bilge Water Management System › Piping
Issued 13 January 2016
Resolved
Repipe bilge system starboard side hull, IAW 46 CFR 176.700.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: System replaced with new materials.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2016
Resolved
Repair all cracked stantions identified, prior to credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: All fractures re-welded.
Construction/Loadline › Hull › Keel
Issued 13 January 2016
Resolved
Extend skid plate protection on both portand starboard bows by 12" for beaching operations, IAW 46 CFR 176.700.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: 12" new sections were added to bow areas for protection.
Construction/Loadline › Hull › Side Shell
Issued 13 January 2016
Resolved
Repair areas identified where previous repairs using bondo were done. Current conditions are allowing water behind repairs, also weld portside stern support identified during inspection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 January 2016