SUPER HAWK is a 1987 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in March 2026, along with 13 deficiencies and 1 casualty investigation in 2010.
Records from 2010 to 2026. Most recent: inspection, 31 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)62.0 ft × 22.0 ft × 7.0 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1987
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Regulatory (Subpart C or D), Gross Ton 56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
31 March 2026Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8340919
11 March 2026Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8325254
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2025Resolved
Renew life ring.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2025
Resolved 5 May 2025
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2023Resolved
Vessel only had 09 flares. Required 12. All red or 6/6 red/orange.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 8 May 2023
Resolution: Complete.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 3 May 2023Resolved
Vsl required to install a UL 217 compliant series of interconnected smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 8 May 2023
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2023Resolved
The vessels waterlight did not work and upon investigation alkaline AAs were installed vice the correct lithium AAs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 8 May 2023
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 May 2023Resolved
Drills were not being logged.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 8 May 2023
Resolution: Logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2020Resolved
Prior to operating on Oceans or Coastwise route provide approved lights for all PFD's.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 June 2020
Resolved 13 October 2020
Each penetration must be accomplished using an acceptable metallic through hull fitting that is weled or other approved method. Salt water intake between hull and isolation valve has temporary repair (flex hose). Remove and repair with permenant fitting. See photo #1. 46 CFR 182.720(d)(1), 46 CFR 176.800
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 2 May 2019
Resolution: Repaired with threaded fitting. See photo #2
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 May 2016Resolved
Alcohol testing kit is expired
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2016
Resolved 22 May 2016
Resolution: Recieved a pictures from the captain demonstrating new testing kits
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 May 2016Resolved
Eye wash and aspirin is expired
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2016
Resolved 22 May 2016
Resolution: [name withheld] sent pictures of the new eye wash and aspirin
Engineering › Pressure Vessel › Relief Valve
Issued 18 May 2016Resolved
potable water pressure tank does not have a relief valve installed
Due 23 May 2016
Resolved 22 May 2016
Resolution: [name withheld] sent pictures of the relief valve installed on the potable water pressure tank
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 May 2016Resolved
the forward watertight bulkhead in the engine room has penetrations that are not watertight
Due 23 May 2016
Resolved 22 May 2016
Resolution: [name withheld] sent pictures demonstrating the bulkhead is watertight
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 May 2016Resolved
the port engine shaft coupling is exposed and is a hazard to the crew
Due 23 May 2016
Resolved 22 May 2016
Resolution: [name withheld] sent pictures demonstrating a guard has been installed
Documentation › Certificates/Documents › Stability Letter
Issued 18 May 2016Resolved
The vessel went under a repower and the net weight change is approximately 6,000 lbs. Demonstrate compliance with MTN 04-95.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 8 June 2016
Resolution: A updated stability letter was issued by MSC
26 June 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3959932
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.