MAURY USCG vessel records
← All vessels

SPECTRUM

SPECTRUM is a 1963 passenger vessel (inspected). The Coast Guard has recorded 3 inspections since 2016, most recently in June 2017, along with 19 deficiencies — 4 with no resolution recorded — and 1 operational control.

Records from 2016 to 2017. Most recent: inspection, 2 June 2017.

Built
1963
Last inspected
2 June 2017
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 June 2017
…with no type recorded1
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA8188
Flag
UNITED STATES
Maury page id
psix-44549

Documentation record

Registered dimensions (L × B × D)59.2 ft × 18.9 ft × 3.5 ft
Registered tonnagegross 36 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEDSEL HAYDEN BASHOR · MURRELLS INLET, SC, UNITED STATES · built 1963
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NORTH STAR Passenger (Inspected) · MISLE 43118 · 29 April 2017 · activity 6137068

Inspection history · 3

2 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6163346
29 April 2017 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6137068
18 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5880570

Deficiency record · 19

Lifesaving › Lifefloat › Lifeline
Issued 31 May 2016 Resolved
Replace grab line on both 20 man life floats.
Due 7 June 2016
Resolved 1 July 2016
Resolution: Replaced.
Lifesaving › Lifefloat › Retroreflective Material
Issued 31 May 2016 Resolved
install retrotape on both 20 man lifefloats and label vessel name.
Due 7 June 2016
Resolved 1 July 2016
Resolution: installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 31 May 2016 No resolution recorded
Provide 1 floating elec water light for life float.
Due 7 June 2016 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Serviceable
Issued 31 May 2016 Resolved
perform in water test.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 July 2016
Resolution: test sat.
Construction/Loadline › Structures › Superstructure
Issued 31 May 2016 Resolved
Repair 2x1ft hole on cabin topside.
Due 14 June 2016
Resolved 1 July 2016
Resolution: repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2016 Resolved
repair or replace mast white head light prior to night or low vis operations.
Condition: Improper/Lack of Maintenance
Due 31 May 2016
Resolved 1 July 2016
Resolution: repaired.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 May 2016 Resolved
Install MMSI # in VHF Radio as per MSIB-15-15.
Due 31 May 2016
Resolved 1 July 2016
Resolution: Insatlled.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 May 2016 No resolution recorded
Provide valid COD onboard vessel.
Due 31 May 2016 — due date passed with no resolution recorded
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 31 May 2016 Resolved
Repair or replace port MDE Tacometer.
Due 31 May 2016
Resolved 1 July 2016
Resolution: Repaired.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 May 2016 Resolved
Perform 5&6 year service on all portalbe ext.
Due 1 June 2016
Resolved 1 July 2016
Resolution: serviced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 May 2016 Resolved
Provide F/F annual serive report as per NFPA 12.
Due 31 May 2016
Resolved 1 July 2016
Resolution: serviced.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 31 May 2016 No resolution recorded
Repair or replace stbd mde attached cooling water pump. (leaking seal) PTCPFH
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2016 — due date passed with no resolution recorded
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 31 May 2016 Resolved
Update emergency broadcast with new callsign.
Due 7 June 2016
Resolved 1 July 2016
Resolution: Corrected.
Documentation › Logs/Records › Drug Test Records
Issued 31 May 2016 Resolved
provide pre-employment drug testing results for new hires.
Due 7 June 2016
Resolved 1 July 2016
Resolution: Provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 31 May 2016 No resolution recorded
perform MOB and FireDrill WITH USCG onboard.
Action required: 705 - Other - as specified
Due 11 July 2016 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 31 May 2016 Resolved
Secure h20 wash down pump fwd of engroom.
Due 7 June 2016
Resolved 1 July 2016
Resolution: secured.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 May 2016 Resolved
Vessel owner failed to make vessel availble for Annual Inspection. Inspection was due NLT 19 Jan 2016.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Resolution: Inspection completed on 31 May 2016.
Electrical › Electric Generation Source (service) › Generator
Issued 18 May 2016 Resolved
#1 SSDG NOT AVAILABLE FOR INSPECTION. MAKE AVAIL PTCPFH
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2016
Resolved 1 July 2016
Resolution: OP test sat.
Electrical › Electric Generation Source (service) › Generator
Issued 18 May 2016 Resolved
#2 SSDG NOT AVAIL FOR INSPECTION. MAKE AVAIL PTCPFH
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 1 July 2016
Resolution: Generator to be removed. See note.

Ownership record